期刊文献+
共找到171篇文章
< 1 2 9 >
每页显示 20 50 100
Thermal performance assessment of self-rotating twisted tapes and Al_(2)O_(3) nanoparticle in a circular pipe 被引量:1
1
作者 Chuanshuai Dong Lin Lu +1 位作者 Tao Wen Shaojie Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第4期77-86,共10页
In view of the practical importance of the heat transfer devices in various thermal engineering fields including chemical and nuclear engineering,this study aims at developing an effective method of heat transfer enha... In view of the practical importance of the heat transfer devices in various thermal engineering fields including chemical and nuclear engineering,this study aims at developing an effective method of heat transfer enhancement by using selfrotating twisted tapes(SRTTs)and Al_(2)O_(3) nanoparticles.The effect of the selfrotating twisted tapes and Al2O3 nanoparticles on the thermal performance was comprehensively investigated in a circular pipe.The experimental results indicated the heat transfer rate was effectively improved by SRTTs in comparison of plain tube.In addition,the heat transfer multiplier with SRTTs decreased from 1.38 to 1.08 with the Reynolds number increasing from 19,322 to 64,407,while the friction factor multiplier decreased from 1.61 to 1.32.Besides,the results indicated that the employment of Al_(2)O_(3) nanoparticles and SRTTs demonstrated superior thermal performance to the single SRTTs.As Reynolds number increases from 19,322 to 64,407,the heat transfer multiplier decreased from 2.08 to 1.18 in the mass concentration of 3.0%and from 1.38 to 1.08 in mass concentration of 0.0%.Finally,the new heat transfer and friction factor correlations considering the combined effect of Al2O3 nanoparticle and SRTTs were developed within 10%deviation of experimental values. 展开更多
关键词 Heat transfer enhancement Nanoparticles Friction factor self-rotating twist tapes Thermal performance factor
下载PDF
Tubular Heat Enhancement Using Twisted Tape Inserts with Large Holes
2
作者 Ali Jaber Abdulhamed Aws Al-Akam +1 位作者 Wisam J.Khudhayer Ali Sabri Allw 《Energy Engineering》 EI 2024年第2期273-290,共18页
Heat augmentation techniques play a vital role in the heating and cooling processes in industries,including solar collectors and many applications that utilize heat exchangers.Several studies are based on inserting fi... Heat augmentation techniques play a vital role in the heating and cooling processes in industries,including solar collectors and many applications that utilize heat exchangers.Several studies are based on inserting fillers inside the tubes to enhance heat transfer.This investigation considered the effects of twisted tapes with large holes on a tubular heat exchanger’s(HX)heat transmission,pressure drop,and thermal boosting factor.In the experimental section,counter-swirl flow generators used twisted tapes with pairs of 1.0 cm-diameter holes and changes in porosity(Rp)at 1.30%and 2.70%.In the experiments,air was utilized as a working fluid in a tube with a circular cross-section.The turbulent flow was considered,with Reynolds numbers(Re)domain from 4800 to 9500,and a boundary condition with a uniform wall heat flux was constructed.The findings expound that when the number of holes rose,the Nusselt number(Nu),the factor of friction(f),and the thermal enhancement factor(η)all increased as well.Additionally,as the friction factor increased,the Nusselt number of the tape-equipped tube was noticeably higher.Additionally,it was discovered that the friction factor was between 70%and 94%lower than the values of the tube without tape,while the(Nu)was between 87%and 97%higher than the conventional tube values.The maximum value ofηis 89%.According to the experimental results,empirical correlations for Nu,f,andηwere also generated. 展开更多
关键词 TUBULAR heat exchanger tape inserts twisted tape
下载PDF
Turbulent Heat Transfer and Pressure Drop in Tube Fitted with Square-cut Twisted Tape 被引量:10
3
作者 P.Murugesan K.Mayilsamy S.Suresh 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第4期609-617,共9页
Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes(STT) and plain twisted tapes(PTT) are investigated experimentally u... Heat transfer,friction factor and thermal enhancement factor characteristics of a double pipe heat exchanger fitted with square-cut twisted tapes(STT) and plain twisted tapes(PTT) are investigated experimentally using the water as working fluid.The tapes(STT and PTT) have three twist ratios(y=2.0,4.4 and 6.0) and the Reynolds number ranges from 2000 to 12000.The experimental results reveal that heat transfer rate,friction factor and thermal enhancement factor in the tube equipped with STT are significantly higher than those fitted with PTT. The additional disturbance and secondary flow in the vicinity of the tube wall generated by STT are higher compared to that induced by the PTT is referred as the reason for better performance.Over the range considered,the Nusselt number,friction factor and thermal enhancement factor in a tube with STT are respectively,1.03 to 1.14,1.05 to 1.25 and 1.02 to 1.06 times of those in tube with PTT.An empirical correlation is also formulated to match with experimental data of Nusselt number and friction factor for STT and PTT. 展开更多
关键词 heat transfer enhancement friction factor plain twisted tape square-cut twisted tape secondary flow
下载PDF
Heat Transfer and Friction Factor Studies in a Circular Tube Fitted with Twisted Tape Consisting of Wire-nails 被引量:13
4
作者 P. Murugesan K. Mayilsamy S. Suresh 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第6期1038-1042,共5页
This paper deals with the experimental investigation on Nusselt number,friction factor and thermal en-hancement factor of a double pipe heat exchanger equipped with twisted tape consisting wire nails(WN-TT) and plain ... This paper deals with the experimental investigation on Nusselt number,friction factor and thermal en-hancement factor of a double pipe heat exchanger equipped with twisted tape consisting wire nails(WN-TT) and plain twisted tapes(P-TT) with three different twist ratios of y 2.0,4.4 and 6.0. Test runs are conducted using the water as the working fluid with Reynolds number range between 2000 and 12000 for WN-TT and P-TT. It is found that Nusselt number,friction factor and thermal enhancement factor in the tube equipped with WN-TT appreciably higher than those in the tube fitted with P-TT and plain tube. Over the range considered Nusselt number,friction factor and thermal enhancement factor in a tube with WN-TT are respectively,1.08 to 1.31,1.1 to 1.75 and 1.05 to 1.13 times of those in tube with P-TT. The better performance of WN-TT is due to combined effects of the follow-ing factors:(1) common swirling flow generated by P-TT,(2) additional turbulence offered by the wire nails. Em-pirical correlations for Nusselt number,friction factor and thermal enhancement factor are also formulated from the experimental results of WN-TT and P-TT. 展开更多
关键词 heat transfer enhancement friction factor plain twisted tape TURBULENCE swirl flow
下载PDF
Thermohydraulics of Turbulent Flow Through Heat Exchanger Tubes Fitted with Circular-rings and Twisted Tapes 被引量:6
5
作者 Smith Eiamsa-ard Vichan Kongkaitpaiboon Kwanchai Nanan 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第6期585-593,共9页
The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported.... The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported. The circular-ring turbulators were individually employed and together with the twisted tape swirl generators in the heated section of the tube. Three different pitch ratios (I/D = 1.0, 1.5, and 2.0) of the CRT and three different twist ratios (y/W= 3, 4, and 5) of the TT were introduced. The experiments were conducted using air as the working fluid under a uniform wall heat flux condition, for the Reynolds number between 6000 and 20000. The experimental results reveal that the heat transfer rate, friction factor and thermal performance factor of the combined CRT and qT are considerably higher than those of CRT alone. For the range examined, the Sncreases of mean Nusselt number, friction factor and thermal performance, in the tube equipped with combined devices, respectively, are 25.8%, 82.8% and 6.3% over those in the tube with the CRT alone. The highest thermal performance factor of 1.42 is found for the combined device consisting of the CRT with l/D = 1.0 and TT with y/W= 3. The correlations of the Nusselt number, friction factor and thermal performance factor of the tubes with combined devices are also developed in terms of Reynolds number, Prandtl number, twist ratio and pitch ratio. 展开更多
关键词 heat transfer enhancement circular-ring twisted tape swirl generator TURBULATOR heat exchanger
下载PDF
3D Numerical Study on Compound Heat Transfer Enhancement of Converging-diverging Tubes Equipped with Twin Twisted Tapes 被引量:4
6
作者 洪宇翔 邓先和 张连山 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第3期589-601,共13页
The paper presents a 3D numerical simulation of turbulent heat transfer and flow characteristics in converging-diverging tubes (CDs) and converging-diverg)ng tubes.equi.pped with twin counter-swirling twisted tapes... The paper presents a 3D numerical simulation of turbulent heat transfer and flow characteristics in converging-diverging tubes (CDs) and converging-diverg)ng tubes.equi.pped with twin counter-swirling twisted tapes (CDTs). The effects of Reynolds number (Re= 10000-20000), pitch length (P= 11.25, 22.5 mm), rib height (e = 0.5, 0.8, 1.1 ram), pitch ratio (8= 1 " 8, 5 " 4, 8 " 1), gap distance between twin t)visted tapes (b = 0.5, 4.5, 8.5 mm) and tape number (n = 2, 3, 4, 5, 6) on Nusselt number (Nu), Iriction tactor 0') and thermal enhancement factor (r/) are investigated under uniform heat flux conditions,using water as working fluid. In order to illustrate the heat transter and tlu^d tlow mechamsms, flow structures m ~StJs and ~SDIs are presented. The obtained results reveal that all geometric parameters have important effects on the thermal performance of CD and CDT, and both CD and CDT show better thermal performance than plain tube at the constant pumping power. It is also found that the increases in the Nusselt number and friction factor for CDT are, respectively, up to 6.3%-35.7% and 1.75-5.3 times of thecorresponding bare CD. All CDTs have good thermal perbrmance with greater than 1 which indicates that the compound heat transfer technique of CDT is commendable for the maximum enhanced heat transfer rate. 展开更多
关键词 heat transfer enhancement converging-diverging tube twisted tape numerical simulation
下载PDF
The Current Situation of the Study on Twisted Tape Inserts in Pipe Exchangers 被引量:3
7
作者 Changzhong Man Chong Wang Jinyu Yao 《Journal of Marine Science and Application》 2014年第4期477-483,共7页
Heat transfer enhancement is used in many applications including heat exchangers, air conditioning, and refrigeration systems; hence many researchers have conducted experimental and numerical researches on heat transf... Heat transfer enhancement is used in many applications including heat exchangers, air conditioning, and refrigeration systems; hence many researchers have conducted experimental and numerical researches on heat transfer enhancement and have developed various techniques and methods. As a passive heat transfer technique, twisted tapes are widely used in various industries for their cost savings, lower maintenance requirements and the fact that they are easily set up. This paper introduces the principle of heat transfer enhancement of twisted tapes and reviews some of the experimental works done by researchers on this technique in recent years. The variously modified twisted tape inserts are widely researched and used to enhance heat transfer efficiency for heat exchangers. Twisted tapes perform better in low Re conditions and in square tubes. However, they could also cause higher pressure drops. Twisted tapes have great potential and profound implications if they can be used in traditional heat exchangers. Besides this, some correlations between the Nusselt number and friction factors are presented in this paper. 展开更多
关键词 heat exchanger twisted tape swirl flow heat transfer enhancement correlation pipe exchanger
下载PDF
Thermal performance of tubular heat exchanger with multiple twisted-tape inserts 被引量:9
8
作者 Suriya Chokphoemphun Monsak Pimsarn +1 位作者 Chinaruk Thianpong Pongjet Promvonge 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第5期755-762,共8页
The paper presents an experimental investigation on enhanced heat transfer and pressure loss characteristics by using single, double, triple, and quadruple twisted-tape inserts in a round tube having a uniform heat-fl... The paper presents an experimental investigation on enhanced heat transfer and pressure loss characteristics by using single, double, triple, and quadruple twisted-tape inserts in a round tube having a uniform heat-fluxed wall. The investigation has been conducted in the heat exchanger tube inserted with various twisted-tape numbers for co- and counter-twist arrangements for the turbulent air flow, Reynolds number (Re) from 5300 to 24000. The typical single twisted-tape inserts at two twist ratios, y/w = 4 and 5, are used as the base case, while the other multiple twisted-tape inserts are aty/w = 4 only. The experimental results of heat transfer and pressure drop in terms of Nusselt number (Nu) and friction factor 00, respectively, reveal that Nu increases with the increment of Re and of twisted-tape number. The values of Nu for the inserted tube are in a range of 1.15-2.12 times that for the plain tube while f is 1.9-4.1 times. The thermal enhancement factor of the inserted tube under similar pumping power is evaluated and found to be above unity except for the single and the double co-twisted tapes. The quadruple counter-twisted tape insert provides the maximum thermal performance. 展开更多
关键词 Thermal performance twisted tape arrangement Turbulator Nusselt number Friction factor
下载PDF
Investigation for Natural Convection Heat Transfer of Sucrose Solution Using a Converging and Diverging Tube with Regularly——spaced Twisted Tapes 被引量:1
9
作者 Zhang Lianshan Deng Xianhe +1 位作者 Liu Weitao Yang Zhiping 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2014年第1期81-89,共9页
The natural convection heat transfer of a 60% sucrose solution in a vertical converging-diverging tube(CD) with regularly-spaced twisted tapes(RSTT) has been investigated numerically and experimentally. The effects of... The natural convection heat transfer of a 60% sucrose solution in a vertical converging-diverging tube(CD) with regularly-spaced twisted tapes(RSTT) has been investigated numerically and experimentally. The effects of wall temperature and number of RSTT on the Nusselt number were studied in detail. The distributions of velocity and temperature in the 60% sucrose solution were studied and the simulated results of CD with RSTT were compared with those of the smooth tube. The influence of Rayleigh number and RSTT on the Nusselt number was conducted experimentally. The results indicate that the Nusselt number of the 60% sucrose solution obviously increased with the number of RSTT but increased inconspicuously with 2 and more twisted tapes. The simulation shows that the distance for achieving an optimal heat transfer performance is 46 times the diameter of the tube. The mechanism of the natural convection heat transfer enhancement of the 60% sucrose solution in relationship with the CD and the RSTT was analyzed, and the change of average tangential velocity with the axial distance was presented to demonstrate that the enhancement of heat transfer was realized mainly because of the increase in tangential velocity. 展开更多
关键词 natural convection regularly-spaced twisted tapes numerical simulation sucrose solution
下载PDF
Heat transfer in turbulent tube flow inserted with loose-fit multi-channel twisted tapes as swirl generators
10
作者 Suttisak Kunlabud Varesa Chuwattanakul +2 位作者 Vichan Kongkaitpaiboon Pitak Promthaisong Smith Eiamsa-ard 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2017年第6期372-378,共7页
Heat transfer and flow behaviors in three-dimensional circular tubes with loose-fit multiple channel twisted tapes were numerically studied. The investigation was examined for Reynolds numbers (Re) ranging from 5000... Heat transfer and flow behaviors in three-dimensional circular tubes with loose-fit multiple channel twisted tapes were numerically studied. The investigation was examined for Reynolds numbers (Re) ranging from 5000 to 15,000, by using air as testing fluid. Effects of the multiple channel number (N = 2, 3, and 4), clearance ratio (CR = 0.0, 0.025, 0.05, and 0.075) on heat transfer enhancement and flow friction were examined. The numerical results indicate that the tubes with loose-fit multiple channel twisted tapes perform higher heat transfer rates than the plain tube. The enhanced heat transfer rate is escorted with larger pressure drop. Both heat transfer and pressure drop increase with increasing multiple channel number (N) and decreasing clearance ratio (CR). Heat transfer augmented by the loose-fit multiple channel twisted tape with N = 4 is higher than those enhanced by the ones with N = 2 and 3 by around 9.5-17.8% and 5.8-7.8%, respectively. In addition, the loose-fit multiple channel twisted tapes with clearance ratio of 0.025, 0.05, and 0.075 give lower heat transfer rates than the one with CR = 0.0 by around 8.4%, 17.5%, and 28.8%, respectively. 展开更多
关键词 Heat transfer Heat transfer enhancement Loose-fit multiple channel twisted tape Swirling flow
下载PDF
Simulation of Heat Transfer in a Tubular Pipe Using Different Twisted Tape Inserts
11
作者 Md. Moniruzzaman Bhuyan Ujjwal K. Deb +1 位作者 M. Shahriar Simul Acherjee 《Open Journal of Fluid Dynamics》 2017年第3期397-409,共13页
This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short... This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short length twisted tape inserts. The length of the pipe is approximately 2436.80 mm long with 29 mm inner and 33 mm outer diameter respectively. A constant heat flux is taken which generated the boundary layer of the pipe close to the flowing fluid around the boundary. The simulations are considered for the stationary and the time dependent module for 35 seconds with different length of inserts. The comparisons are made among the results. We observed that the transfer of heat is enhanced significantly with the increase of the length of inserts inside the computational domain. We also found that, full length twisted tape inserts are more effective than comparing with the short length inserts and without insert. 展开更多
关键词 Heat Transfer NON-ISOTHERMAL Flow TUBULAR PIPE twisted tape INSERTS SIMULATION
下载PDF
Hydraulic and thermal analysis of automatic transmission fluid in the presence of nano-particles and twisted tape:An experimental and numerical study
12
作者 Ali QASEMIAN Faranak MORADI +2 位作者 Amin KARAMATI Ali KESHAVARZ Amin SHAKERI 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3404-3417,共14页
In the present study,hydraulic and thermal behavior of an automatic transmission nano-fluid(ATNF) inside a tube with a twisted tape has been investigated.The heat transfer improvement and pressure drop of transmission... In the present study,hydraulic and thermal behavior of an automatic transmission nano-fluid(ATNF) inside a tube with a twisted tape has been investigated.The heat transfer improvement and pressure drop of transmission oil for each of case of using twisted tape and nano-particles were also examined separately and compared with each other.The Cu O nano-particles were used to prepare the ATNF.The effects of different Reynolds numbers and different mass fractions of nano-particle were investigated.The results showed that applying nano-particles and twisted tape simultaneously increases both the pressure drop and Nusselt number,on average by about 53% and 76%,respectively.By using a parameter,namely thermal performance index η,the effect of increasing heat transfer and pressure drop was studied simultaneously.The heat transfer improvement predominates the pressure drop increment in all cases.It was observed that the highest thermal performance of 1.9 was obtained at Re=634 and Φ=2%.Furthermore,regarding the increment of the Nu number,it was shown that the use of twisted tapes individually could increase the average Nu number by 41%,while the max increment arising from individual use of 2% nano-particles is 13%,so using twisted tape is a more effective-technique for this case study. 展开更多
关键词 automatic transmission fluid(ATF) NANOFLUID twisted tape heat transfer thermal performance
下载PDF
Pipes with Trapezoidal Cut Twisted Tape Inserts in the Laminar Flow Regime:Nusselt Number and Friction Coefficient Analysis
13
作者 Shrikant Arunrao Thote Netra Pal Singh 《Fluid Dynamics & Materials Processing》 EI 2023年第2期501-511,共11页
The thermal behavior of pipes with a twisted tape inside(used to enhance heat transfer through the tube wall)is studied in the laminar flow regime.Oil is used as the work fluid with the corresponding Reynolds Number s... The thermal behavior of pipes with a twisted tape inside(used to enhance heat transfer through the tube wall)is studied in the laminar flow regime.Oil is used as the work fluid with the corresponding Reynolds Number spanning the interval 200–2000.It is found that in such conditions the‘Nusselt Number’(Nu)gradually increases with reducing the tape twist ratio,whereas the friction factor is detrimentally affected by the presence of the tape(as witnessed by the comparison with the companion case where a plain tube is considered).In particular,it is shown that the heat transfer efficiency can be improved by nearly 69%if tape inserts with a relatively low twist ratio are used.On the basis of these findings,it is concluded that loose fit tape inserts are superior to tight fit tapes in terms of heat transfer and ease of replacement. 展开更多
关键词 Friction factor laminar flow Nusselt Number trapezoidal-cut twisted tape
下载PDF
Analysis of Friction and Heat Transfer Characteristics of Tubes with Trapezoidal Cut Twisted Tape Inserts
14
作者 Shrikant Arunrao Thote Netra Pal Singh 《Fluid Dynamics & Materials Processing》 EI 2023年第3期711-722,共12页
The thermo-hydraulic properties of circular tubes with a twisted tape inside(used accordingly to induce turbulence and enhance heat transfer through the tube wall)are described for Reynolds Numbers ranging from 830 to... The thermo-hydraulic properties of circular tubes with a twisted tape inside(used accordingly to induce turbulence and enhance heat transfer through the tube wall)are described for Reynolds Numbers ranging from 830 to 1990.Tapes twisted with the three distinct twist ratios are considered,namely,6,4.4 and 3.Air is used as the working fluid in several tests.For the sake of comparison,the standard tube with no insert is also examined.It is shown that in the presence of the twisted tape,the‘frictional factor’,‘Nusselt Number’and the‘thermal performance factor’are much higher than those obtained for the plain tube.Moreover,the tapes having the lowest twist ratio,i.e.,3,are more effective than the others in terms of heat transfer augmentation.The‘thermal performance factor’is greater than one for all the twisted tapes used in the experiments,which confirms the enhanced performances of the heat exchanger and the related savings in terms of total energy. 展开更多
关键词 Friction factor nusselt number performance ratio trapezoidal cut twisted tape insert
下载PDF
内置多叶扭带的碳化硅换热管强化传热特性研究
15
作者 李佳豪 虞斌 +1 位作者 江超 吕林 《化工机械》 CAS 2024年第3期375-381,共7页
为了研究碳化硅换热管的流动和传热特性,达到增强综合换热能力的目的。采用数值模拟方法对内置4种不同结构扭带的换热管进行分析,确定四叶扭带模型作为后续研究对象,对比了在4种自定义的节距和宽度两种结构参数下,不同入口风速工况的换... 为了研究碳化硅换热管的流动和传热特性,达到增强综合换热能力的目的。采用数值模拟方法对内置4种不同结构扭带的换热管进行分析,确定四叶扭带模型作为后续研究对象,对比了在4种自定义的节距和宽度两种结构参数下,不同入口风速工况的换热管的热力性能。结果表明:扭带宽度对换热管的换热能力相较于节距具有更显著的强化作用,四叶扭带节距为360 mm、宽度为45 mm时换热管的综合换热能力最强,为1.59,此时换热管的努塞尔数相较光管提升了244.37%。 展开更多
关键词 换热器 碳化硅换热管 多叶扭带 强化换热 数值模拟 综合换热性能
下载PDF
THREE-DIMENSIONAL NUMERICAL SIMULATION OF THERMAL-HYDRAULIC PERFORMANCE OF A CIRCULAR TUBE WITH EDGEFOLD-TWISTED-TAPE INSERTS 被引量:3
16
作者 CUI Yong-zhang TIAN Mao-cheng 《Journal of Hydrodynamics》 SCIE EI CSCD 2010年第5期662-670,共9页
Three-dimensional numerical simulations and experiments were carried out to study the heat transfer characteristics and the pressure drop of air flow in a circular tube with Edgefold-Twisted Tape (ETT) inserts and w... Three-dimensional numerical simulations and experiments were carried out to study the heat transfer characteristics and the pressure drop of air flow in a circular tube with Edgefold-Twisted Tape (ETT) inserts and with classic Spiral-Twisted-Tape (STT) inserts of the same twist ratio. The RNG turbulence model for mildly swirling flows, the enhanced wall treatment for low Reynolds numbers, and the SIMPLE pressure-velocity method were adopted to simulate the flow and heat transfer characteristics. Within the range of Reynolds number from 2 500 to 9 500 and the twist ratio y from 5.4 to 11.4, the Nusselt number of the tube with ETT inserts is found to be 3.9% - 9.2% higher than that with STT inserts, and the friction factor of the tube with ETT inserts is 8.7% - 74% higher than that of STT inserts. The heat enhancement is due to higher tangential velocity and asymmetrical velocity profile with the increase and decrease of the periodic velocity within an edgefold length. It is found that main factors affecting the heat transfer of ETT inserts are the twist angle and the gap width between the tube and inserts. A larger twist angle leads to a higher tangential velocity, and larger Nusselt number and friction factor. The thermal-hydraulic performance slowly decreases as the twist angle increases. The gap width between tube and inserts has a significant influence on the heat transfer, while little influence on pressure drops. The thermal-hydraulic performance increases in average by 124% and 140% when the gap width reduces from 1.5 mm to 1.0 mm and 0.5 mm. The larger the gap width, the higher velocity through the gap will be, which would reduce the main flow velocity and tangential velocity. So a small gap is desirable. Comparing experimental and numerical results at variable air flow and tube wall temperature, the numerical results are found to be in a reasonable agreement with the experiment results, with difference of the Nusselt number in a range of 1.6% - 3.6%, and that of the friction factor in a range of 8.2% - 13.6%. 展开更多
关键词 heat transfer enhancement Edgefold-twisted-tape (ETT) Spiral-twisted-tape (STT) thermal-hydraulic performance
原文传递
Heat transfer characteristics in micro-fin tube equipped with double twisted tapes: Effect of twisted tape and micro-fin tube arrangements 被引量:5
17
作者 EIAMSA-ARD S. WONGCHAREE K. 《Journal of Hydrodynamics》 SCIE EI CSCD 2013年第2期205-214,共10页
An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of ... An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of the compound devices in the following configurations: (1) twisted tapes acted in the same direction (for co-swirl) while MF and twisted tapes acted in the same (parallel) direction (MF-CoDTs:P), (2) twisted tapes acted in the same direction (for co-swirl) while micro-fin tube and twisted tapes acted in opposite directions (MF-CoDTs:O) and (3) twisted tapes acted in opposite directions for counter swirl (MF-CDTs). The MF alone and the MF equipped with a single twisted tape in parallel/opposite arrangement were also considered for comparison. The experiments were conducted for the flows with the Reynolds numbers between 5 650 and 17 000, under uniform heat flux condition. The experimental results indicate that MF-CDTs induce stronger swirl/turbulence flow, resulting in higher heat transfer rate, friction factor and thermal performance factor than other combined devices. The thermal performance factors associated with the use of MF-CDTs were found to be higher than those associated with the uses of MF-CoDTs:P, MF-CoDTs:O and MF alone up to 9.3%, 6.5% and 56.4%, respectively. The empirical correlations developed using the present experimental data for the Nusselt number, friction factor and thermal performance factor are also reported. 展开更多
关键词 micro-fin tube (MF) double twisted-tapes (DTs) co-swirl counter-swirl heat transfer enhancement
原文传递
纳米流体在内置扭带管中的流动传热特性研究进展
18
作者 刘文盛 邢震 +1 位作者 杨鹤 赵磊 《辽宁化工》 CAS 2024年第1期142-146,共5页
随着世界能源消耗与日俱增,能源短缺问题已经成为当下不得不解决的难题。而换热过程往往伴随着大量的能源浪费,所以提升换热效率势在必行。扭带内插物作为常见的被动强化换热元件由于其操作简单、成本低的特点成为换热行业的宠儿。另一... 随着世界能源消耗与日俱增,能源短缺问题已经成为当下不得不解决的难题。而换热过程往往伴随着大量的能源浪费,所以提升换热效率势在必行。扭带内插物作为常见的被动强化换热元件由于其操作简单、成本低的特点成为换热行业的宠儿。另一方面,纳米流体作为新兴换热工质,其良好的热物性能也让研究人员找到了方向,从而将扭带内插物与纳米流体结合,实现双重强化换热,大大提升了换热效率。 展开更多
关键词 纳米流体 扭带 强化换热
下载PDF
内置扭带管内湍流流动与传热数值模拟 被引量:13
19
作者 吴金星 王超 +2 位作者 王明强 刘艳会 李亚飞 《郑州大学学报(工学版)》 CAS 北大核心 2017年第3期10-14,共5页
为了提高内置扭带管的综合性能,开发了一种三边扭带,并对空管、普通扭带管、格栅扭带管及三边扭带管内流体流动与传热特性进行了数值模拟.以水为工质,采用RNG k-ε湍流模型,扭带扭率y=2.0,取Re=5 000~30 000,计算了扭带管内努赛尔数Nu... 为了提高内置扭带管的综合性能,开发了一种三边扭带,并对空管、普通扭带管、格栅扭带管及三边扭带管内流体流动与传热特性进行了数值模拟.以水为工质,采用RNG k-ε湍流模型,扭带扭率y=2.0,取Re=5 000~30 000,计算了扭带管内努赛尔数Nu、阻力系数f和综合性能评价因子η,与同工况下空管进行了对比.结果表明,相比于空管、普通扭带管和格栅扭带管,三边扭带管的综合性能较好,其η值比空管高出11.9%~33.2%. 展开更多
关键词 普通扭带 格栅扭带 三边扭带 强化换热 数值模拟
下载PDF
汽轮机冷凝器自转塑料纽带自动在线除垢防垢技术 被引量:14
20
作者 俞天兰 彭德其 +4 位作者 刘桂英 蒋少青 支校衡 俞秀民 杨相红 《现代化工》 EI CAS CSCD 北大核心 2002年第6期46-48,共3页
通过调查实例强调了保持传热面清洁的重要性 ,在计算水垢对汽轮机冷凝器传热系数影响的基础上 ,论证了仅 0 2 5mm厚的水垢会导致传热系数下降 31 2 % ,介绍了自转塑料纽带的自动除垢防垢和传热强化的原理及其试验结果 。
关键词 汽轮机 冷凝器 防垢 节能 自转塑料纽带 污垢 除垢 自动化 发电厂
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部