This paper describes the standardization of the proton-induced x-ray emission(PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard refe...This paper describes the standardization of the proton-induced x-ray emission(PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials(SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 Me V obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.展开更多
The influence of the selection of receiving slits and the use of standard samples with random orientation on the result of quantitative texture analysis was tested and discussed. The result proves that it will improve...The influence of the selection of receiving slits and the use of standard samples with random orientation on the result of quantitative texture analysis was tested and discussed. The result proves that it will improve the precision of the analysis to use proper slits and a randomly oriented standard sample. A simple method was given to interpolate the correction curves of random intensities.展开更多
Silicon isotope analysis traditionally uses a standard-sample bracketing (SSB) method that relies upon greater instrument stability than can be consistently expected. The following proposed method reduces the level ...Silicon isotope analysis traditionally uses a standard-sample bracketing (SSB) method that relies upon greater instrument stability than can be consistently expected. The following proposed method reduces the level of instrumental stability required for the analysis process and provides a valid solution for high-precision and accurate studies of Si isotopic compositions. Rock samples were dissolved by using alkali fusion and acidification. Silicon isotopes were purified with an ion exchange resin. Interfering peaks for isotopes were separated by using a Nu Plasma 1700 multi-collector inductively coupled plasma mass spectrometry (MS) system in high-resolution mode (M/AM 〉 8000 RP). Two magnesium isotopes (25Mg and 26Mg) and three silicon isotopes (28Si, 29Si, and 3;Si) were analyzed in the same data collection cycle. Mg isotopes were used as an internal standard to calibrate the mass discrimination effects in MS analysis of Si isotopes in combination with the SSB method in order to reduce the effects of MS interference and instrumental mass dis- crimination on the accuracy of measurements. The conventional SSB method without the Mg internal standard and the proposed SSB method with Mg calibration delivered consistent results within two standard deviations. When Mg was used as an internal standard for calibration, the analysis precision was better than 0.05 %0 amu.展开更多
In China, little information is known about the nutrient requirements of jackfruits and the traditional nutrient management usually depends on the experience. Therefore, in this study, an attempt was made to standardi...In China, little information is known about the nutrient requirements of jackfruits and the traditional nutrient management usually depends on the experience. Therefore, in this study, an attempt was made to standardize the leaf sampling technique and the suitable range of leaf nutrient concentrations for jackfruit (Artocarpus heterophyllus Lam.) nutrient status diagnosis. The sampling result was affected by canopy height, leaf age and time of sampling. Therefore, the three factors were studied. The results illustrated that the stability in level of nutrient concentrations was in 3 - 6 month-old leaves from the central part of the canopy. The most stable period was from April to May for leaf sampling. It was recommended that the stable intracanopy and stable period of nutrient concentrations could be used as the standards of leaf sampling technique. Based on the leaf sampling technique, the standard of leaf nutrient concentrations was summarized, and could be used as the standard of nutrient suitability evaluation.展开更多
1 Introduction The primary goal of the Deep-time Digital Earth project is to develop an open collaboration and data sharing platform that enables the transition of deep-time geoscientific research to a Big Data driven...1 Introduction The primary goal of the Deep-time Digital Earth project is to develop an open collaboration and data sharing platform that enables the transition of deep-time geoscientific research to a Big Data driven paradigm.Such an open platform will require the ability to effectively and efficiently access and integrate a wide variety of digital Earth data.展开更多
目前,各社会团体积极参与中医药标准的制定和发布,特别是“十四五”以来,中医药团体标准化工作更是迎来了提质增效的关键阶段。深入评估社会团体发布的中医药标准质量,是推进中医药团体标准工作的关键环节和重点任务。前期已研制并形成...目前,各社会团体积极参与中医药标准的制定和发布,特别是“十四五”以来,中医药团体标准化工作更是迎来了提质增效的关键阶段。深入评估社会团体发布的中医药标准质量,是推进中医药团体标准工作的关键环节和重点任务。前期已研制并形成了中医药团体标准评价体系(System of Consortium Standards Rating and Evaluation of Traditional Chinese Medicine, SCORETCM)。在上述背景下,本研究通过专家共识法,设计了一套基于SCORE-TCM的中医药团体标准抽样评价方案,应用场景为对于特定社会团体发布的标准,或各团体发布的特定技术类别的标准进行快速评估。该方案涵盖了标准抽样、材料收集、标准评价、结果解读的完整流程,为中医药团体标准的抽样评价工作提供了参考方案。展开更多
文摘This paper describes the standardization of the proton-induced x-ray emission(PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials(SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 Me V obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.
文摘The influence of the selection of receiving slits and the use of standard samples with random orientation on the result of quantitative texture analysis was tested and discussed. The result proves that it will improve the precision of the analysis to use proper slits and a randomly oriented standard sample. A simple method was given to interpolate the correction curves of random intensities.
基金funded by the National Natural Science Foundation of China(Grant Nos.41427804,41421002,41373004)Beijing SHRIMP Center Open Foundation,and Program for Changjiang Scholars and Innovative Research Team in University(Grant No.IRT1281)the MOST Research Foundation from the State Key Laboratory of Continental Dynamics(BJ08132-1)
文摘Silicon isotope analysis traditionally uses a standard-sample bracketing (SSB) method that relies upon greater instrument stability than can be consistently expected. The following proposed method reduces the level of instrumental stability required for the analysis process and provides a valid solution for high-precision and accurate studies of Si isotopic compositions. Rock samples were dissolved by using alkali fusion and acidification. Silicon isotopes were purified with an ion exchange resin. Interfering peaks for isotopes were separated by using a Nu Plasma 1700 multi-collector inductively coupled plasma mass spectrometry (MS) system in high-resolution mode (M/AM 〉 8000 RP). Two magnesium isotopes (25Mg and 26Mg) and three silicon isotopes (28Si, 29Si, and 3;Si) were analyzed in the same data collection cycle. Mg isotopes were used as an internal standard to calibrate the mass discrimination effects in MS analysis of Si isotopes in combination with the SSB method in order to reduce the effects of MS interference and instrumental mass dis- crimination on the accuracy of measurements. The conventional SSB method without the Mg internal standard and the proposed SSB method with Mg calibration delivered consistent results within two standard deviations. When Mg was used as an internal standard for calibration, the analysis precision was better than 0.05 %0 amu.
文摘In China, little information is known about the nutrient requirements of jackfruits and the traditional nutrient management usually depends on the experience. Therefore, in this study, an attempt was made to standardize the leaf sampling technique and the suitable range of leaf nutrient concentrations for jackfruit (Artocarpus heterophyllus Lam.) nutrient status diagnosis. The sampling result was affected by canopy height, leaf age and time of sampling. Therefore, the three factors were studied. The results illustrated that the stability in level of nutrient concentrations was in 3 - 6 month-old leaves from the central part of the canopy. The most stable period was from April to May for leaf sampling. It was recommended that the stable intracanopy and stable period of nutrient concentrations could be used as the standards of leaf sampling technique. Based on the leaf sampling technique, the standard of leaf nutrient concentrations was summarized, and could be used as the standard of nutrient suitability evaluation.
基金the US National Science Foundation for their long-time support of the development of the IGSN(Grant Nos.NSF-0445178,NSF-0514551,NSF-0552123)the Earth Chem system(Grant No.NSF-0522195)+1 种基金operation of both systems as part of the IEDA Data Facility(Grant Nos.NSF-0950477,NSF-1636653)the Alfred P.Sloan Foundation for a grant to Columbia University to support the development of a global,scalable,and sustainable technical and organizational infrastructure for persistent unique identifiers of physical scientific samples.
文摘1 Introduction The primary goal of the Deep-time Digital Earth project is to develop an open collaboration and data sharing platform that enables the transition of deep-time geoscientific research to a Big Data driven paradigm.Such an open platform will require the ability to effectively and efficiently access and integrate a wide variety of digital Earth data.
文摘目前,各社会团体积极参与中医药标准的制定和发布,特别是“十四五”以来,中医药团体标准化工作更是迎来了提质增效的关键阶段。深入评估社会团体发布的中医药标准质量,是推进中医药团体标准工作的关键环节和重点任务。前期已研制并形成了中医药团体标准评价体系(System of Consortium Standards Rating and Evaluation of Traditional Chinese Medicine, SCORETCM)。在上述背景下,本研究通过专家共识法,设计了一套基于SCORE-TCM的中医药团体标准抽样评价方案,应用场景为对于特定社会团体发布的标准,或各团体发布的特定技术类别的标准进行快速评估。该方案涵盖了标准抽样、材料收集、标准评价、结果解读的完整流程,为中医药团体标准的抽样评价工作提供了参考方案。
文摘流程工业颗粒物成分的在线检测具有低延时、安全可靠及低成本等要求,目前没有适合的技术手段.微波等离子炬(Microwave plasma torch,MPT)原子发射光谱法具有直接进样、成本低及装置安全可靠等优点,有潜力成为工业在线检测的重要手段.本文基于MPT装置对水泥样品进行直接进样分析,并针对工业应用场景中标准样品受限的问题,采用单样本定标技术(Single sample calibration,SSC)进行定量分析.SSC法中的线性假设容易受到等离子体参数波动的影响,导致精度下降.为此,提出了一种基于参数标准化的SSC算法PS-SSC(SSC based on parameter standardization),通过激发温度和电子数密度对谱线强度进行修正以提高SSC的定量精度.为了评估MPT和PS-SSC方法联用在水泥成分快速分析中的有效性,将GSB 08-2985-2013标准水泥粉末气溶胶直接引入MPT中进行定量分析,并将PS-SSC与现有定量方法进行比较.与传统SSC方法相比,PS-SSC方法的决定系数R2由‒0.81~0.81提高到0.39~0.88,平均相对误差由4.39%~10.33%提高到1.55%~5.83%,平均相对标准偏差由2.89%~9.40%提高到2.28%~6.50%,展现了该方法在工业在线成分检测中的应用潜力.