期刊文献+
共找到436篇文章
< 1 2 22 >
每页显示 20 50 100
Optimum Design of the Control System for a Laser Beam Riding Guidance Anti-Tank Missile 被引量:3
1
作者 翁彦 王正杰 张天桥 《Journal of Beijing Institute of Technology》 EI CAS 2000年第2期160-165,共6页
The optimum theory and methods were adopted to design the laser beam riding guidance anti tank missile's control system in the short run. Through building the mathematical model of system, selecting a proper meth... The optimum theory and methods were adopted to design the laser beam riding guidance anti tank missile's control system in the short run. Through building the mathematical model of system, selecting a proper method and taking advantage of computer's high speed calculation and logic traits, an optimal controller was designed. Simulation results showed that the designed control system has fair performance and it satisfies the tactical and technical requirements. The results also demonstrate that by the combination of the optimizing methods and the computer the control system could be designed as soon as possible. 展开更多
关键词 laser beam riding guidance anti-tank missile control system optimizing method
下载PDF
Ground target localization algorithm for semi-active laser terminalcorrection projectile 被引量:2
2
作者 Xing-long LI Wen-jin YAO +2 位作者 Li-kun ZHU Xiao-ming WANG Ji-yan YU 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2016年第3期234-241,共8页
A target localization algorithm,which uses the measurement information from onboard GPS and onboard laser detector to acquire the target position,is proposed to obtain the accurate position of ground target in real ti... A target localization algorithm,which uses the measurement information from onboard GPS and onboard laser detector to acquire the target position,is proposed to obtain the accurate position of ground target in real time in the trajectory correction process of semi-active laser terminal correction projectile.A target localization model is established according to projectile position,attitude and line-of-sight angle.The effects of measurement errors of projectile position,attitude and line-of-sight angle on localization accuracy at different quadrant elevation angles are analyzed through Monte-Carlo simulation.The simulation results show that the measurement error of line-of-sight angle has the largest influence on the localization accuracy.The localization accuracy decreases with the increase in quadrant elevation angle.However,the maximum localization accuracy is less than 7 m.The proposed algorithm meets the accuracy and real-time requirements of target localization. 展开更多
关键词 semi-active laser guidance TERMINAL correction PROJECTILE Target LOCALIZATION LOCALIZATION accuracy
下载PDF
Determining the characteristics of the initial fixed-focus of laser beam riding guidance information field
3
作者 梅跃松 于剑桥 +1 位作者 于天朋 李景须 《Journal of Beijing Institute of Technology》 EI CAS 2013年第1期6-11,共6页
Determining characteristics of the initial fixed-focus are a key technique for the design of laser beam riding guidance missile. Through analyzing the effects of the initial cone information field in guidance and cont... Determining characteristics of the initial fixed-focus are a key technique for the design of laser beam riding guidance missile. Through analyzing the effects of the initial cone information field in guidance and control system of missile, those effects are considered as an approximate lead com- pensation network. The position and time of guidance spot initial fixed-focus can be designed. This method is applied to determine the characteristics of the initial fixed-focus of laser information field for a laser beam guidance gun-launched missile. The results of design and simulation show that the initial cone information field apparently speeds up convergence on the initial trajectory, and provides a guarantee for the implementation of minimum range index of a missile system. 展开更多
关键词 laser beam riding guidance laser information field lead-in trajectory missile guidanceand control system gun-launched missile
下载PDF
超声引导下股神经阻滞联合硬膜外麻醉在大隐静脉激光闭合术中的应用
4
作者 赵仕浩 王萍 +2 位作者 杨扬 杨光 徐江 《血管与腔内血管外科杂志》 2024年第8期987-990,1021,共5页
目的探讨超声引导下股神经阻滞联合硬膜外麻醉在大隐静脉激光闭合术中的应用效果。方法收集2020年5月至2023年7月于铜陵市人民医院接受大隐静脉激光闭合术治疗的120例大隐静脉曲张患者的临床资料,根据麻醉方式的不同将患者分为联合组(n=... 目的探讨超声引导下股神经阻滞联合硬膜外麻醉在大隐静脉激光闭合术中的应用效果。方法收集2020年5月至2023年7月于铜陵市人民医院接受大隐静脉激光闭合术治疗的120例大隐静脉曲张患者的临床资料,根据麻醉方式的不同将患者分为联合组(n=57)和对照组(n=63)。联合组患者在手术过程中采用超声引导下股神经阻滞联合硬膜外麻醉,对照组仅采用硬膜外麻醉。比较两组患者的手术指标、麻醉相关指标、术后不同时间(术后1、6、12、24 h)的疼痛感[视觉模拟评分法(VAS)评分]、术后首次下床活动时间及术后并发症的发生情况。结果联合组患者的手术时间短于对照组患者(P﹤0.05);两组患者的术中输液量比较,差异无统计学意义(P﹥0.05)。在首次穿刺大隐静脉时和手术完成即刻两个时间点,联合组患者的心率和平均动脉压均低于对照组患者(P﹤0.05)。联合组患者术后各时间点的VAS评分均明显低于对照组患者,术后首次下床活动时间明显短于对照组患者(P﹤0.01)。两组患者术后并发症发生情况比较,差异无统计学意义(P﹥0.05)。结论对于行大隐静脉激光闭合术的大隐静脉曲张患者,超声引导下股神经阻滞联合硬膜外麻醉可以安全、显著地改善其术后疼痛感,同时改善患者围手术期心率、血压,缩短手术时间,且不会增加术后并发症。 展开更多
关键词 超声引导 股神经阻滞 硬膜外麻醉 大隐静脉曲张 激光闭合术
下载PDF
激光制导武器的作战使用综述
5
作者 胡飞 郭宇 +3 位作者 胡尧博 王硕 彭思洋 伍友利 《兵器装备工程学报》 CAS CSCD 北大核心 2024年第8期309-316,共8页
激光制导技术由于其高精度、强抗干扰能力而被广泛应用到武器制导系统中。介绍了激光制导原理、激光制导武器的分类、发展历程、激光制导武器的作战使用情况,分析了影响武器投放精度的干扰因素,为激光制导武器后续的发展和战场使用研究... 激光制导技术由于其高精度、强抗干扰能力而被广泛应用到武器制导系统中。介绍了激光制导原理、激光制导武器的分类、发展历程、激光制导武器的作战使用情况,分析了影响武器投放精度的干扰因素,为激光制导武器后续的发展和战场使用研究提供借鉴。 展开更多
关键词 激光制导 发展综述 作战使用 激光干扰
下载PDF
激光红外复合制导光学系统小型化共孔径设计
6
作者 王琛 胡小波 +5 位作者 曹尔聪 潘源吉 石娟 师国瑞 梁晓瑜 陈洪波 《弹箭与制导学报》 北大核心 2024年第3期74-80,共7页
半主动激光探测制导和红外成像制导结合使用能够获得主被动探测模式,提升导引头的全天候探测能力、抗干扰能力和目标捕获跟踪能力。激光红外复合制导导引头中光学系统的性能直接影响制导武器系统的探测距离、目标识别和命中精度。若复... 半主动激光探测制导和红外成像制导结合使用能够获得主被动探测模式,提升导引头的全天候探测能力、抗干扰能力和目标捕获跟踪能力。激光红外复合制导导引头中光学系统的性能直接影响制导武器系统的探测距离、目标识别和命中精度。若复合导引头采用分离孔径式光学系统,每一个通道采用单独的光学结构和探测器,较容易实现,但会带来空间配准等方面的问题,并且系统体积和质量较大。文中采用共孔径光学结构,考虑激光(1.064μm)和红外(8~12μm)光谱波段的透过率,通过焦距匹配方法共用整流罩和一片高透过率透镜完成复合光学设计。激光信号通过整流罩和第一片透镜聚焦,被位于孔径中心的平面反射镜反射到镜筒侧面,由四象限探测器接收。红外光信号经孔径外围通过,由包含衍射透镜的三片透镜成像到非制冷焦平面探测器上。整个光学系统经过-45~60℃无热化设计,光学系统整体结构简单紧凑、体积小,总长小于86 mm,口径小于62 mm。此光学系统设计可以应用于激光红外复合制导火箭弹、导弹等武器平台,为高效费比的高技术战争提供技术储备。 展开更多
关键词 激光 红外 复合制导 光学设计
下载PDF
多场景舰炮激光制导弹药照射指示特性研究
7
作者 牟晋升 宗思光 +1 位作者 张鑫 杨劭鹏 《激光与红外》 CAS CSCD 北大核心 2024年第1期97-103,共7页
为提高舰炮武器系统作战效率,对舰炮激光制导弹药在典型条件下激光照射指示与跟踪探测进行仿真验证。针对舰炮武器系统激光精确制导弹药使用场景,建立了激光照射指示与弹药探测跟踪模型,编制了激光制导光区仿真计算软件,研究了不同气象... 为提高舰炮武器系统作战效率,对舰炮激光制导弹药在典型条件下激光照射指示与跟踪探测进行仿真验证。针对舰炮武器系统激光精确制导弹药使用场景,建立了激光照射指示与弹药探测跟踪模型,编制了激光制导光区仿真计算软件,研究了不同气象能见度条件、不同攻击目标、舰艇本舰照射指示、无人机载照射指示等条件下激光精确制导弹药与照射器间的协同方法及指示、探测能力,并进行仿真计算。得到反射激光能量密度随着角度θ_(c)的增大过程中,反射激光的能量密度在逐渐减小,激光入射角度θ_(z)越大,反射激光的能量密度越大,两种照射方式产生的激光制导光区较为接近。无人机激光制导方式与舰船激光制导方式各有优劣,可适用于不同应用场景。 展开更多
关键词 舰炮武器系统 激光制导光区 无人机载照射 舰载激光照射
下载PDF
B超引导下1470 nm激光联合聚桂醇硬化剂注射治疗周围动静脉畸形的疗效分析
8
作者 莫自增 郭钰磊 +4 位作者 冯才鑫 叶犀皓 刘洋 吴志贤 梁杰 《中国美容医学》 CAS 2024年第10期85-89,共5页
目的:探讨B超引导下1470 nm激光联合聚桂醇硬化剂注射治疗周围动静脉畸形的疗效。方法:选择2019年1月-2024年2月笔者科室收治并确诊为周围动静脉畸形的81例患者,按周围动静脉畸形影像学类型特征,将患者分为三组(其中Ⅰ型组14例,Ⅱ型组30... 目的:探讨B超引导下1470 nm激光联合聚桂醇硬化剂注射治疗周围动静脉畸形的疗效。方法:选择2019年1月-2024年2月笔者科室收治并确诊为周围动静脉畸形的81例患者,按周围动静脉畸形影像学类型特征,将患者分为三组(其中Ⅰ型组14例,Ⅱ型组30例,Ⅲ型组37例),术前检测病灶大小,联合治疗后1个月复诊,对比三组患者手术治疗次数、治疗前后病灶缩小程度,分析治疗的有效性及安全性。结果:本组81例患者,治愈率为29.63%,总有效率为60.49%。病灶缩小程度和治疗总有效率均Ⅱ型组>Ⅰ型组>Ⅲ型组,Ⅲ型组治疗次数明显多于Ⅰ型组与Ⅱ型组,以上指标三组比较差异均有统计学意义(P<0.05);所有患者术后未出现呼吸困难、严重过敏、脏器损伤及血管栓塞等严重并发症。结论:B超引导下1470 nm激光联合聚桂醇硬化剂治疗周围动静脉畸形,组织损伤程度小,安全性高,疗效好,并可根据周围动静脉畸形影像学分型采取最佳治疗方案。 展开更多
关键词 周围动静脉畸形 影像学分型 超声引导 激光治疗 联合治疗 聚桂醇泡沫硬化剂
下载PDF
激光定位引导下颅脑肿瘤穿刺活检术安全性和有效性的价值分析
9
作者 古运涛 翟聪 +1 位作者 胡奇 杨刚 《医师在线》 2024年第9期42-44,共3页
目的探究激光定位引导下颅脑肿瘤穿刺活检术安全性和有效性的价值。方法选取2023年1月~2023年12月我院收治的疑似颅脑肿瘤患者共96例,均进行激光定位引导下颅脑肿瘤穿刺活检术。分析所有患者的活检结果,评估穿刺活检的准确性和安全性。... 目的探究激光定位引导下颅脑肿瘤穿刺活检术安全性和有效性的价值。方法选取2023年1月~2023年12月我院收治的疑似颅脑肿瘤患者共96例,均进行激光定位引导下颅脑肿瘤穿刺活检术。分析所有患者的活检结果,评估穿刺活检的准确性和安全性。结果激光定位引导下颅脑肿瘤穿刺活检术的病理结果显示,恶性肿瘤主要包括脑胶质瘤、弥漫性大B细胞瘤、肺癌脑转移、神经母细胞瘤,良性肿瘤包括炎性病变、胶质细胞增生;激光定位引导下颅脑肿瘤穿刺活检术阳性结果87例,阴性结果9例,其中假阴性3例,假阳性0例,准确度为96.88%(93/96),灵敏度为96.67%(87/90),特异度为100%(6/6);本研究96例患者中,出现并发症的患者共8例,3例患者出现局部小片出血,其中2例患者伴有轻微头痛的症状,经过3 d左右的观察,患者的症状均减轻;4例患者术后出现颅内高压,经过抗感染、雾化化痰、营养神经及降压治疗后,症状均好转;1例患者出现脑疝后死亡。结论激光定位引导下颅脑肿瘤穿刺活检术是一种有效的临床诊断方式,具有准确性高、安全性高的特点,对颅脑肿瘤的诊断有一定价值。 展开更多
关键词 激光定位引导 颅脑肿瘤 穿刺活检 安全性 有效性
下载PDF
激光半主动制导中光斑对四象限探测器定位精度影响分析
10
作者 仲启媛 刘峰 +1 位作者 曹纹诚 冯梦豪 《火箭军工程大学学报》 2024年第4期61-67,共7页
针对激光半主动制导中,光斑的实际位置、大小及能量分布等因素影响探测器定位精度的问题,基于四象限探测器的光斑位置检测原理,建立了探测器检测位置与光斑实际位置的关系模型,在控制背景光为定值的条件下,通过弹目距离的变化改变光斑半... 针对激光半主动制导中,光斑的实际位置、大小及能量分布等因素影响探测器定位精度的问题,基于四象限探测器的光斑位置检测原理,建立了探测器检测位置与光斑实际位置的关系模型,在控制背景光为定值的条件下,通过弹目距离的变化改变光斑半径,仿真了激光传输距离和导引头光学系统焦距与定位误差之间的关系。仿真结果表明:激光远场传输条件下距离变化所引起的定位误差变化缓慢;在弹目距离一定时,短焦条件下焦距变化所引起的定位误差小于长焦条件下的焦距变化,且短焦条件下光斑的误差更容易控制在允许范围内。 展开更多
关键词 激光半主动制导 四象限探测器 高斯光斑 定位精度
下载PDF
船舶甲板抛丸机器人系统设计
11
作者 韩子延 王晶 王跃 《造船技术》 2024年第1期65-68,84,共5页
针对目前抛丸装置操纵控制不便、智能化程度低等问题,设计一种船舶甲板抛丸机器人系统。论述该系统的结构组成、控制系统、软件设计和激光导引规划工作流程,并在实船甲板上进行试验。试验结果表明,该系统可实现对抛丸、除尘和移动等作... 针对目前抛丸装置操纵控制不便、智能化程度低等问题,设计一种船舶甲板抛丸机器人系统。论述该系统的结构组成、控制系统、软件设计和激光导引规划工作流程,并在实船甲板上进行试验。试验结果表明,该系统可实现对抛丸、除尘和移动等作业环节的控制,并具备一定的自主导引抛丸作业功能。 展开更多
关键词 船舶甲板抛丸机器人系统 抛丸分系统 除尘分系统 控制系统 软件设计 激光导引
下载PDF
A quantitative method for calculating irradiation area of laser target designator
12
作者 ZHANG Jiandong HUANG Zhiyi SHI Guoqing 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第4期633-641,共9页
In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area... In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area of the laser target designator,this paper,based on the existing aircraft motion model and the laser transmission model,uses two aircraft as respectively the carrier of the laser-guided bomb and the carrier of the laser designator and proposes a method to calculate the global irradiation area of the airborne laser designator.By using the proposed algorithm,the global irradiation area when attacking a large flat target or a large spherical target is simulated respectively.Finally,according to the simulation results,the influences of different factors on the shapes of the irradiation area are discussed in detail. 展开更多
关键词 laser-guided BOMB IRRADIATION area laser target designator semi-active guidance
下载PDF
LIMITATIONS OF CANCER MARGIN DELINEATION BY MEANS OF AUTOFLUORESCENCE IMAGING UNDER CONDITIONS OF LASER SURGERY
13
作者 ALEXANDRE DOUPLIK AZHAR ZAM +3 位作者 RALPH HOHENSTEIN ANGELOS KALITZEOS EMEKA NKENKE FLORIAN STELZLE 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2010年第1期45-51,共7页
Limitations of cancer margin delineation and surgical guidance by means of autofluorescence imaging under conditions of laser ablation were investigated and preliminary results are presented.PinPoint^(TM)(Novadaq Tech... Limitations of cancer margin delineation and surgical guidance by means of autofluorescence imaging under conditions of laser ablation were investigated and preliminary results are presented.PinPoint^(TM)(Novadaq Technologies Inc.,Canada)was used to capture digital images and Er:YAG laser(2.94μm,Glissando,WaveLight^(TM),Germany)was exploited to cause laser ablation on both normal and cancer sites of the specimen.It was shown that changes of the autofluorescence image after ablation extend beyond the actual sizes of the ablation loci.The tumor tissue after the laser ablation starts to emit fluorescent light within the green wavelength band(490-550nm)similar to normal tissue stating that the current technology of in-process tissue classification fails.However,when the autofluorescence was collected in the red range(600-750nm),then the abnormal/normal contrast was reduced,but still present even after the laser ablation.The present study highlights the importance of finding a proper technology for surgical navigation of cancer removal under conditions of high power effects in biological tissues. 展开更多
关键词 Cancer margin delineation surgical guidance surgical navigation autofluorescence imaging laser surgery laser ablation
下载PDF
Shipborne aerosol IR decoy modulated by laser
14
作者 叶晓英 吴刚 +1 位作者 邓盼 范宁 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2004年第4期395-398,共4页
Working principles, features, current situation and future development of the aerosol IR decoys are summarized in this paper, and a new type aerosol IR decoy——aerosol IR decoy modulated by laser is emphasized. The s... Working principles, features, current situation and future development of the aerosol IR decoys are summarized in this paper, and a new type aerosol IR decoy——aerosol IR decoy modulated by laser is emphasized. The simulation results show that compared with the traditional IR decoys, the late-model aerosol IR decoy effectively enhances the capability of protecting targets and countermining IR guidance weapons. It is a new direction of aerosol IR decoys. 展开更多
关键词 SHIPBORNE IR guidance IR decoy AEROSOL modulated by laser
下载PDF
双极激光定位导航仪在深部肺结节经皮穿刺活检中的应用 被引量:4
15
作者 董建春 杨纯杰 +4 位作者 薛青青 胡颜江 吴月敏 周芸 夏阳 《介入放射学杂志》 CSCD 北大核心 2023年第10期1010-1013,共4页
目的分析双极激光定位导航仪在深部肺结节经皮穿刺活检中的应用效果。方法选择2020年1月至2022年8月溧阳市人民医院因深部肺结节行经皮穿刺活检的患者120例,按1∶1交错法配对分为激光引导组60例和常规方法组60例。比较两组穿刺过程中的... 目的分析双极激光定位导航仪在深部肺结节经皮穿刺活检中的应用效果。方法选择2020年1月至2022年8月溧阳市人民医院因深部肺结节行经皮穿刺活检的患者120例,按1∶1交错法配对分为激光引导组60例和常规方法组60例。比较两组穿刺过程中的一次性穿刺到位率、穿刺次数、CT扫描次数、操作时间、并发症发生率。以操作时间和穿刺次数为学习曲线评价指标,比较两组的学习曲线。结果与常规方法组相比,激光引导组的一次性穿刺到位率高(100%比15%)、穿刺次数少[(1.00±0.00)次比(3.15±0.68)次]、CT扫描次数少[(3.00±0.00)次比(5.15±0.68)次]、操作时间短[(19.30±2.38)min比(25.72±2.46)min],气胸率发生低(11.7%比30.0%)、出血率低(6.7%比21.7%),差异均有统计学意义(均P<0.05)。激光引导组均一次性穿刺到位,从第6例开始操作时间明显缩短并稳定,常规方法组从第20例开始操作时间和穿刺次数逐渐下降并稳定。结论双极激光定位导航仪在深部肺结节行经皮穿刺活检中一次性穿刺成功率高,稳定性高,并发症少,学习曲线低易于掌握,有较高的临床应用价值。 展开更多
关键词 激光定位 CT引导 肺穿刺 肺结节
下载PDF
超声引导下微创单通道经皮肾镜钬激光碎石术治疗肾结石的效果 被引量:2
16
作者 贾延 冯辉 +1 位作者 赵计伟 毛俊杰 《中国社区医师》 2023年第4期25-27,共3页
目的:探讨超声引导下微创单通道经皮肾镜钬激光碎石术治疗肾结石的临床效果。方法:选择2018年1月-2022年9月邳州市人民医院收治的68例肾结石患者参与此次研究,以随机数字表法分为对照组(34例,常规开放性手术治疗)和治疗组(34例,超声引... 目的:探讨超声引导下微创单通道经皮肾镜钬激光碎石术治疗肾结石的临床效果。方法:选择2018年1月-2022年9月邳州市人民医院收治的68例肾结石患者参与此次研究,以随机数字表法分为对照组(34例,常规开放性手术治疗)和治疗组(34例,超声引导下微创单通道经皮肾镜钬激光碎石术治疗)。比较两组手术指标、肾功能指标、并发症发生情况及术后3 d结石清除率。结果:治疗组较对照组手术时间更短,术中出血量更少,疼痛评分更低,差异有统计学意义(P<0.001)。治疗前,两组血肌酐、尿素氮、β_(2)-微球蛋白水平比较,差异无统计学意义(P>0.05);治疗后,治疗组血肌酐、尿素氮、β_(2)-微球蛋白水平低于对照组,差异有统计学意义(P<0.001)。治疗组并发症发生率2.88%,较对照组的23.53%更低,术后3 d结石清除率97.06%,较对照组76.47%更高,差异有统计学意义(P<0.05)。结论:超声引导下微创单通道经皮肾镜钬激光碎石术治疗肾结石的创伤小,可有效改善肾功能,降低术后并发症发生率。 展开更多
关键词 超声引导 微创单通道经皮肾镜钬激光碎石术 肾结石 清除率 肾功能
下载PDF
高重频激光对多激光制导武器干扰机理研究
17
作者 罗威 杨华兵 +1 位作者 许鹏程 马伟博 《激光与红外》 CAS CSCD 北大核心 2023年第8期1250-1254,共5页
本文基于仿真计算方法,研究高重频激光对多激光制导武器的干扰机理。发现重复频率与波门宽度是影响总干扰有效概率的主要因素,干扰反应时间与激光制导信号样式对总干扰有效概率的影响较小,重复频率取整数值则会增大干扰有效概率的不确... 本文基于仿真计算方法,研究高重频激光对多激光制导武器的干扰机理。发现重复频率与波门宽度是影响总干扰有效概率的主要因素,干扰反应时间与激光制导信号样式对总干扰有效概率的影响较小,重复频率取整数值则会增大干扰有效概率的不确定性。针对性提出了“一对多”干扰、提前干扰、重复频率避免取整数等改进措施,研究结论可为提升高重频激光对多激光制导武器干扰效果提供参考。 展开更多
关键词 高重频激光 激光干扰 激光制导 多目标 重复频率
下载PDF
基于多模型网络的激光末制导炮弹诸元解算方法
18
作者 刘畅 雷红波 +2 位作者 林时尧 范世鹏 王江 《兵工学报》 EI CAS CSCD 北大核心 2023年第9期2745-2755,共11页
针对射表解算激光末制导炮弹射击诸元存在较大的截断误差及无法快速精确解算的缺陷,提出一种基于多模型网络的射击诸元快速精确求解方法。建立制导炮弹6自由度弹道模型,分析初始条件中表尺、程装等对射程的影响。考虑气温、气压和风干... 针对射表解算激光末制导炮弹射击诸元存在较大的截断误差及无法快速精确解算的缺陷,提出一种基于多模型网络的射击诸元快速精确求解方法。建立制导炮弹6自由度弹道模型,分析初始条件中表尺、程装等对射程的影响。考虑气温、气压和风干扰等因素对求解结果的影响,应用最小二乘法对气温、气压进行拟合,采取层权的方式求取精确弹道风,作为网络模型的部分输入。利用数学仿真手段批量化生成样本,对深度神经网络中的每个模型进行离线训练。对新方法进行数学仿真和飞行试验验证。仿真和试验结果表明,相对于传统的射表,新方法求解精度高,误差率小于0.2%。 展开更多
关键词 激光末制导炮弹 诸元解算 多模型网络 气象条件 深度神经网络
下载PDF
激光探测双胶合透镜校正光学像差方法
19
作者 孟展鹏 陈荷娟 张祥金 《兵器装备工程学报》 CAS CSCD 北大核心 2023年第1期269-274,共6页
针对制导装置光学系统小型化和提高光斑像质的问题,基于初级像差理论,同时结合仿真与像质评价软件,提出了通过设计双胶合透镜组来校正光学像差的方法。该方法在光学系统初始设计阶段引入初级像差理论,设计双胶合透镜来校正光学系统的固... 针对制导装置光学系统小型化和提高光斑像质的问题,基于初级像差理论,同时结合仿真与像质评价软件,提出了通过设计双胶合透镜组来校正光学像差的方法。该方法在光学系统初始设计阶段引入初级像差理论,设计双胶合透镜来校正光学系统的固有像差,使用像质评价软件对整个光学系统生成的光斑质量进行评估。结果表明,双胶合光学系统的生成的光斑在满足巡飞武器用激光半主动制导装置的指标要求的同时,能以较小的设计空间(入瞳直径D=30 mm,透镜组物方面到光敏面的距离为21.5 mm,从入瞳光阑到光敏面的距离是45.5 mm)有效减少单透镜带来的光学像差。 展开更多
关键词 激光半主动制导 光学系统设计 初级像差 双胶合透镜 像质评价
下载PDF
移动激光灯辅助CT-Sim在经皮组织穿刺中的应用
20
作者 谭蕾 宋亮 尹如铁 《现代医药卫生》 2023年第1期1-5,共5页
目的 探讨外置激光导航系统配合模拟定位CT(CT-Sim)在经皮穿刺活检中的应用价值。方法 回顾性分析该院2019年12月至2020年12月经皮穿刺活检术女性患者42例,年龄31~77岁,其中淋巴结穿刺21例,盆腔占位穿刺17例,盆腔囊肿穿刺引流4例,拟穿... 目的 探讨外置激光导航系统配合模拟定位CT(CT-Sim)在经皮穿刺活检中的应用价值。方法 回顾性分析该院2019年12月至2020年12月经皮穿刺活检术女性患者42例,年龄31~77岁,其中淋巴结穿刺21例,盆腔占位穿刺17例,盆腔囊肿穿刺引流4例,拟穿刺病变部位直径(最长径)0.69~15.47 cm。使用LAP外置激光导航系统精确定位到体表穿刺点后,使用飞利浦Big Bore定位CT扫描,确定穿刺针位置、角度无误后,进行穿刺活检,记录手术时间和平均辐射剂量。结果 42例妇科恶性肿瘤患者(其中包括7例行多点穿刺)经此方法穿刺,均一次定位准确,其中17例盆腔占位穿刺平均手术时间(22.00±7.46)min, 14例淋巴结单点穿刺平均手术时间(20.00±4.66)min;7例淋巴结两点穿刺平均手术时间(30.86±4.74)min;4例盆腔淋巴囊肿穿刺引流平均手术时间(26.50±6.45)min。平均CT剂量指数(CTDI)为(35.95±4.17)mGy。结论 利用外置激光导航系统配合CT-Sim,提高了穿刺成功率,缩短了穿刺手术时间和减少了患者的辐射剂量,可实现精准、快捷、安全的经皮穿刺活检。 展开更多
关键词 移动激光灯 CT引导 经皮穿刺
下载PDF
上一页 1 2 22 下一页 到第
使用帮助 返回顶部