AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular le...AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.展开更多
AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmenta...AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.展开更多
Freshwater groundwater lenses(FGLs)serve as an important water resource for remote coral atoll islands,and different hydrogeological data of the islands determine the growth and decay of the FGLs.This study conducted ...Freshwater groundwater lenses(FGLs)serve as an important water resource for remote coral atoll islands,and different hydrogeological data of the islands determine the growth and decay of the FGLs.This study conducted a three-dimensional(3D)numerical model using hydrogeological data from a reclaimed island to evaluate the effects of different locations and sizes of subsurface structures on the formation and macroscale stability of the FGLs.The results revealed that freshwater formation begins earlier than the base model when the subsurface structures are present.Constructing underground structures in Pleistocene aquifers leads to a significant increase in freshwater volume with the enlargement of the structure's size.When these structures are built within Holocene aquifers,as the burial site moves from the edge towards the center of the area,the maximum freshwater volume decreases slightly,with the largest difference being approximately 4×10^(5) m^(3).When the structure constructed in the Holocene aquifer and its central axis does not coincide with the center of the simulated area,the maximum thickness of the FGLs will be shifted from the center of the simulated area to 20-25 m on the side of the structure.When constructed in the Pleistocene aquifer,the thickness of the FGLs increases.This study provides methodology for planning and management of reclaimed lands for water sustainability in the future in coastal areas.展开更多
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This ...AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This retrospective consecutive case series included patients with subluxated lenses by more than 180 degrees who underwent lens extraction,transcapsular scleral fixation of the standard CTR through equatorial capsulotomy,in-the-bag IOL implantation and with at least 6mo follow-up.Preoperative and postoperative best corrected visual acuity(BCVA),intraocular pressure(IOP),complications,and postoperative IOL tilt and decentration were recorded.RESULTS:Nine eyes of 7 patients with a mean followup of 11.0±3.7mo were included in this study.The BCVA was significantly improved from 0.64±0.22 logMAR preoperatively to 0.21±0.19 logMAR postoperatively(P<0.001).The IOP was within the normal range postoperatively.The mean tilt of the IOL was 4.30°±2.31°(range,1.0°to 8.9°)and the mean decentration of the IOL was 0.37±0.12 mm(range,0.14 to 0.50 mm).No visually threatened intraoperative and postoperative complications were detected during the follow-up period.CONCLUSION:This is a safe and effective surgical technique for managing patients with severely subluxated lenses.It has achieved favorable outcomes with fewer surgical manipulations and less need for advanced capsular support devices.展开更多
AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract s...AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.展开更多
AIM:To investigate the influence of postoperative intraocular lens(IOL)positions on the accuracy of cataract surgery and examine the predictive factors of postoperative biometry prediction errors using the Barrett Uni...AIM:To investigate the influence of postoperative intraocular lens(IOL)positions on the accuracy of cataract surgery and examine the predictive factors of postoperative biometry prediction errors using the Barrett Universal II(BUII)IOL formula for calculation.METHODS:The prospective study included patients who had undergone cataract surgery performed by a single surgeon from June 2020 to April 2022.The collected data included the best-corrected visual acuity(BCVA),corneal curvature,preoperative and postoperative central anterior chamber depths(ACD),axial length(AXL),IOL power,and refractive error.BUII formula was used to calculate the IOL power.The mean absolute error(MAE)was calculated,and all the participants were divided into two groups accordingly.Independent t-tests were applied to compare the variables between groups.Logistic regression analysis was used to analyze the influence of age,AXL,corneal curvature,and preoperative and postoperative ACD on MAE.RESULTS:A total of 261 patients were enrolled.The 243(93.1%)and 18(6.9%)had postoperative MAE<1 and>1 D,respectively.The number of females was higher in patients with MAE>1 D(χ^(2)=3.833,P=0.039).The postoperative BCVA(logMAR)of patients with MAE>1 D was significantly worse(t=-2.448;P=0.025).After adjusting for gender in the logistic model,the risk of postoperative refractive errors was higher in patients with a shallow postoperative anterior chamber[odds ratio=0.346;95% confidence interval(CI):0.164,0.730,P=0.005].CONCLUSION:Risk factors for biometry prediction error after cataract surgery include the patient’s sex and postoperative ACD.Patients with a shallow postoperative anterior chamber are prone to have refractive errors.展开更多
A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-ge...A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run.展开更多
AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and ana...AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications.展开更多
Eclogite lenses in marbles from the Dabie-Sulu ultrahigh-pressure (UHP) terrane are deeply subducted meta-sedimentary rocks. Zircons in these rocks have been used to constrain the ages of prograde and UHP metamorphi...Eclogite lenses in marbles from the Dabie-Sulu ultrahigh-pressure (UHP) terrane are deeply subducted meta-sedimentary rocks. Zircons in these rocks have been used to constrain the ages of prograde and UHP metamorphism during subduction, and later retrograde metamorphism during exhumation. Inherited (detrital) and metamorphic zircons were distinguished on the basis of transmitted light microscopy, cathodoluminescence (CL) imaging, trace element contents and mineral inclusions. The distribution of mineral inclusions combined with CL imaging of the metamorphic zircon make it possible to relate zircon zones (domains) to different metamorphic stages. Domain 1 consists of rounded, oblong and spindly cores with dark-luminescent images, and contains quartz eclogite facies mineral inclusion assemblages, indicating formation under high-pressure (HP) metamorphic conditions of T = 571-668℃ and P =1.7-2.02 GPa. Domain 2 always surrounds domain 1 or occurs as rounded and spindly cores with white-luminescent images. It contains coesite eclogite facies mineral inclusion assemblages, indicating formation under UHP metamorphic conditions of T = 782-849℃ and P 〉 5.5 GPa. Domain 3, with gray-luminescent images, always surrounds domain 2 and occurs as the outermost zircon rim. It is characterized by low-pressure mineral inclusion assemblages, which are related to regional amphibolite facies retrograde metamorphism of T = 600- 710℃ and P = 0.7-1.2 GPa. The three metamorphic zircon domains have distinct ages; sample H1 from the Dabie terrane yielded SHRIMP ages of 245 ± 4 Ma for domain 1, 235 ± 3 Ma for domain 2 and 215± 6 Ma for domain 3, whereas sample H2 from the Sulu terrane yielded similar ages of 244 ± 4 Ma, 233 ± 4 Ma and 214 ± 5 Ma for Domains 1, 2 and 3, respectively. The mean ages of these zones suggest that subduction to UHP depths took place over 10-11 Ma and exhumation of the rocks occurred over a period of 19-20 Ma. Thus, subduction from - 55 km to 〉 160 km deep mantle depth took place at rates of approximately 9.5-10.5 km/Ma and exhumation from depths 〉160 km to the base of the crust at -30 km occurred at approximately 6.5 km/Ma. We propose a model for these rocks involving deep subduction of continental margin lithosphere followed by ultrafast exhumation driven by buoyancy forces after break-off of the UHP slab deep within the mantle.展开更多
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty...AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.展开更多
AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y) were randomized into t...AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y) were randomized into two groups: the test group (30 children, 60 eyes), wearing blue-violet light filtering lenses; and the control group (30 children, 60 eyes), wearing ordinary aspherical lenses. Baseline refractive power of the affected eyes and axial length of the two groups was recorded. After 1-year, the patients underwent contrast sensitivity (glare and non-glare under bright and dark conditions), accommodation-related testing, asthenopia questionnaire assessment, and adverse reaction questionnaire assessment. RESULTS: After ly of wearing the filtering lenses, changes in refractive power and axial length were not significantly different between the two groups (P〉0.05). Under bright conditions, the contrast sensitivities at low and medium- frequency grating (vision angles of 6.3, 4.0, and 2.5) with glare in the test group were significantly higher than in the control group (P〈0.05), while the contrast sensitivity at low-frequency grating (vision angles of 6.3 and 4.0) in the absence of glare in the test group was higher than in the control group (P〈0.05). Under glare and non-glare dark conditions, the contrast sensitivities of various frequencies in the test group did not show significant differences compared with those in the control group (P〉0.05). In the test group, the amplitude of accommodation, accommodative lag, and accommodative sensitivity of patients wearing glasses for 6 and 12mo were significantly elevated (P〈0.05), while the asthenopia gratings were significantly decreased (P〈0.05). Nevertheless, in the control group,the amplitude of accommodation, accommodative lag, and accommodative sensitivity after 12mo were not significantly altered compared with baseline (P〉0.05), and the asthenopia grating was not significantly decreased (P〉0.05). In addition, after wearing glasses for 6 to 12mo, the asthenopia grating of patients in the test group decreased significantly compared with the control group (P〈0.05). At 12mo, the constituent ratio of adverse reactions did not show significant difference between the two groups (P〉0.05). CONCLUSION: A l-year follow-up reveal that compare with ordinary glasses, short-wavelength filtering lenses (blue/ violet-light filters) increase the low- and medium-frequency contrast sensitivity under bright conditions and improved accommodation. They effectively relieved asthenopia without severe adverse reactions, suggesting potential for clinical application. However, no significant advantages in terms of refractive power or axial length progression were found compared with ordinary aspheric lenses.展开更多
·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·ME...·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·METHODS:This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL.IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients.Assessments included monocular and binocular distance vision,with and without best correction.Patients also completed surveys about their distance vision.·RESULTS:Preoperatively,the two study groups were similar in age,in distance visual acuity,and in the magnitude of corneal astigmatism.At 6 months postoperative,binocular uncorrected distance vision was 0.06?à0.14 logMAR in the AcrySof toric IOL group,significantly better than the 0.14?à0.11 logMAR in the spherical IOL group (P<0.05).For eyes with emmetropia as a target,the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes).No patients in the emmetropia/toric IOL group used distance glasses,as compared to 52% of patients in the emmetropia/spherical IOL group.All patients were satisfied or highly satisfied.Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05).·CONCLUSION:Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism.·展开更多
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ...AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.展开更多
AIM: To compare the clinical performance of two types of silicon hydrogel contact lenses used as bandage lenses after LASEK surgery. METHODS: A prospective, double-masked study was conducted on 42 eyes of 21 patients ...AIM: To compare the clinical performance of two types of silicon hydrogel contact lenses used as bandage lenses after LASEK surgery. METHODS: A prospective, double-masked study was conducted on 42 eyes of 21 patients who received binocular LASEK surgeries. The interocular difference in spherical equivalent power was less than -1.50D. Patients were randomly assigned to wear Galyfilcon A (Lens A) bandage contact lens in one eye and Balafilcon A (Lens B) in the fellow eye after the surgery. The responses to a subjective questionnaire on comfort of wearing, corneal epithelial status, conjunctival hyperemia, limbal neovascularization, lens fitting and contact lens debris were assessed 1 and 5 days postoperatively. Corneal endothelium was assessed before and 5 days after the surgery upon bandage lens removal. RESULTS: There was no difference between the two groups in terms of conjunctival hyperemia, limbal neovascularization, contact lens fitting, corneal epithelial status, corneal endothelium cell density (CD) and endothelium cell size (CS) at any postoperative visit. Complaints of discomfort, including foreign body sensation, pain and intolerance were statistically more among Lens B wearers at any postoperative visit (P < 0.05). Lens B appeared to attract much more debris than Lens A at the 5-day post-operative follow-up visit (P < 0.01). CONCLUSION: The two types of silicon hydrogel lenses investigated in this study demonstrated similar clinical performance in terms of corneal responses and lens fitting. However, Lens A showed a better performance in terms of comfort of wearing and deposit resistance.展开更多
AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam c...AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam combined with low temperature and low pressure plasma, the surface characteristics of the IOLs including physical and optical properties were determined by the instruments of IOLs resolution, UV/VIS scanning spectrophotometer, contact angle measurement system, electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM). RESULTS: The color of titanium (Ti) modified IOLs was light yellow and that of titanium nitride (TiN) modified IOLs was light brown. The absorptive degree of ultraviolet rays and the hydrophilicity of the surfaces of modified IOLs were increased, and appeared suitable chemical compositions. The resolution of unmodified and modified IOLs reached normal standard. The surfaces of unmodified and Ti-modified IOLs appeared uniform. The surfaces of TIN-modified IOLs presented fine porcelain structure. CONCLUSION: The optical properties of all IOLs and the surface morphology of the modified IOLs were not affected by modification processes. The surface properties of the modified IOLs were improved.展开更多
The crystalline lens is a transparent,biconvex structure in the eye that,along with the cornea,helps to refract light to be focused on the retina and,by changing shape,it adjusts focal distance(accommodation).The th...The crystalline lens is a transparent,biconvex structure in the eye that,along with the cornea,helps to refract light to be focused on the retina and,by changing shape,it adjusts focal distance(accommodation).The three classes of structural proteins found in the lens areα,β,and γ crystallins.These proteins make up more than 90% of the total dry mass of the eye lens.Other components which can be found are sugars,lipids,water,several antioxidants and low weight molecules.When ageing changes occur in the lens,it causes a gradual reduction in transparency,presbyopia and an increase in the scattering and aberration of light waves as well as a degradation of the optical quality of the eye.The main changes that occur with aging are: 1) reduced diffusion of water from the outside to the inside of the lens and from its cortical to its nuclear zone; 2)crystalline change due to the accumulation of high molecular weight aggregates and insoluble proteins; 3)production of advanced glycation end products(AGEs),lipid accumulation,reduction of reduced glutathione content and destruction of ascorbic acid.Even if effective strategies in preventing cataract onset are not already known,good results have been reached in some cases with oral administration of antioxidant substances such as caffeine,pyruvic acid,epigallocatechin gallate(EGCG),α-lipoic acid and ascorbic acid.Furthermore,methionine sulfoxide reductase A(MSRA) over expression could protect lens cells both in presence and in absence of oxidative stress-induced damage.Nevertheless,promising results have been obtained by reducing ultraviolet-induced oxidative damage.展开更多
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
基金Supported by the National Natural Science Foundation of China(No.52073181,No.52273134).
文摘AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.
基金Supported by the“Municipal School(College)Joint Funding(Zhongnanshan Medical Foundation of Guangdong Province)Project”of Guangzhou Municipal Science and Technology Bureau(No.202201020458)the“Guangzhou Health Science and Technology General Guidance Project(Western Medicine Project)”of Guangzhou Municipal Health Commission(No.20231A011083).
文摘AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.
基金funded by the Fundamental Research Funds for the Central Universities(No.201962005)。
文摘Freshwater groundwater lenses(FGLs)serve as an important water resource for remote coral atoll islands,and different hydrogeological data of the islands determine the growth and decay of the FGLs.This study conducted a three-dimensional(3D)numerical model using hydrogeological data from a reclaimed island to evaluate the effects of different locations and sizes of subsurface structures on the formation and macroscale stability of the FGLs.The results revealed that freshwater formation begins earlier than the base model when the subsurface structures are present.Constructing underground structures in Pleistocene aquifers leads to a significant increase in freshwater volume with the enlargement of the structure's size.When these structures are built within Holocene aquifers,as the burial site moves from the edge towards the center of the area,the maximum freshwater volume decreases slightly,with the largest difference being approximately 4×10^(5) m^(3).When the structure constructed in the Holocene aquifer and its central axis does not coincide with the center of the simulated area,the maximum thickness of the FGLs will be shifted from the center of the simulated area to 20-25 m on the side of the structure.When constructed in the Pleistocene aquifer,the thickness of the FGLs increases.This study provides methodology for planning and management of reclaimed lands for water sustainability in the future in coastal areas.
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
基金Supported by Wenzhou Basic Research Foundation(No.2024Y1244).
文摘AIM:To present a technique of transcapsular scleral fixation of the standard capsular tension ring(CTR)through equatorial capsulotomy and in-the-bag intraocular lens(IOL)implantation in subluxated lenses.METHODS:This retrospective consecutive case series included patients with subluxated lenses by more than 180 degrees who underwent lens extraction,transcapsular scleral fixation of the standard CTR through equatorial capsulotomy,in-the-bag IOL implantation and with at least 6mo follow-up.Preoperative and postoperative best corrected visual acuity(BCVA),intraocular pressure(IOP),complications,and postoperative IOL tilt and decentration were recorded.RESULTS:Nine eyes of 7 patients with a mean followup of 11.0±3.7mo were included in this study.The BCVA was significantly improved from 0.64±0.22 logMAR preoperatively to 0.21±0.19 logMAR postoperatively(P<0.001).The IOP was within the normal range postoperatively.The mean tilt of the IOL was 4.30°±2.31°(range,1.0°to 8.9°)and the mean decentration of the IOL was 0.37±0.12 mm(range,0.14 to 0.50 mm).No visually threatened intraoperative and postoperative complications were detected during the follow-up period.CONCLUSION:This is a safe and effective surgical technique for managing patients with severely subluxated lenses.It has achieved favorable outcomes with fewer surgical manipulations and less need for advanced capsular support devices.
文摘AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions.
基金Supported by the Innovation&Transfer Fund of Peking University Third Hospital(No.BYSYZHKC2021108).
文摘AIM:To investigate the influence of postoperative intraocular lens(IOL)positions on the accuracy of cataract surgery and examine the predictive factors of postoperative biometry prediction errors using the Barrett Universal II(BUII)IOL formula for calculation.METHODS:The prospective study included patients who had undergone cataract surgery performed by a single surgeon from June 2020 to April 2022.The collected data included the best-corrected visual acuity(BCVA),corneal curvature,preoperative and postoperative central anterior chamber depths(ACD),axial length(AXL),IOL power,and refractive error.BUII formula was used to calculate the IOL power.The mean absolute error(MAE)was calculated,and all the participants were divided into two groups accordingly.Independent t-tests were applied to compare the variables between groups.Logistic regression analysis was used to analyze the influence of age,AXL,corneal curvature,and preoperative and postoperative ACD on MAE.RESULTS:A total of 261 patients were enrolled.The 243(93.1%)and 18(6.9%)had postoperative MAE<1 and>1 D,respectively.The number of females was higher in patients with MAE>1 D(χ^(2)=3.833,P=0.039).The postoperative BCVA(logMAR)of patients with MAE>1 D was significantly worse(t=-2.448;P=0.025).After adjusting for gender in the logistic model,the risk of postoperative refractive errors was higher in patients with a shallow postoperative anterior chamber[odds ratio=0.346;95% confidence interval(CI):0.164,0.730,P=0.005].CONCLUSION:Risk factors for biometry prediction error after cataract surgery include the patient’s sex and postoperative ACD.Patients with a shallow postoperative anterior chamber are prone to have refractive errors.
基金supported by the National Natural Science Foundation of China(Nos.11605248,11605249,11605267,and 11805032.)
文摘A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run.
文摘AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications.
基金the National 973 Project of Chinese Ministry of Science and Technology (Grant No. 2003CB716502) the Natural Science Foundation of China (Grant No. 40399143) +1 种基金 the German Science Foundation (DFG grant No. GE 1152/2-2 , WE2850/3- 1).
文摘Eclogite lenses in marbles from the Dabie-Sulu ultrahigh-pressure (UHP) terrane are deeply subducted meta-sedimentary rocks. Zircons in these rocks have been used to constrain the ages of prograde and UHP metamorphism during subduction, and later retrograde metamorphism during exhumation. Inherited (detrital) and metamorphic zircons were distinguished on the basis of transmitted light microscopy, cathodoluminescence (CL) imaging, trace element contents and mineral inclusions. The distribution of mineral inclusions combined with CL imaging of the metamorphic zircon make it possible to relate zircon zones (domains) to different metamorphic stages. Domain 1 consists of rounded, oblong and spindly cores with dark-luminescent images, and contains quartz eclogite facies mineral inclusion assemblages, indicating formation under high-pressure (HP) metamorphic conditions of T = 571-668℃ and P =1.7-2.02 GPa. Domain 2 always surrounds domain 1 or occurs as rounded and spindly cores with white-luminescent images. It contains coesite eclogite facies mineral inclusion assemblages, indicating formation under UHP metamorphic conditions of T = 782-849℃ and P 〉 5.5 GPa. Domain 3, with gray-luminescent images, always surrounds domain 2 and occurs as the outermost zircon rim. It is characterized by low-pressure mineral inclusion assemblages, which are related to regional amphibolite facies retrograde metamorphism of T = 600- 710℃ and P = 0.7-1.2 GPa. The three metamorphic zircon domains have distinct ages; sample H1 from the Dabie terrane yielded SHRIMP ages of 245 ± 4 Ma for domain 1, 235 ± 3 Ma for domain 2 and 215± 6 Ma for domain 3, whereas sample H2 from the Sulu terrane yielded similar ages of 244 ± 4 Ma, 233 ± 4 Ma and 214 ± 5 Ma for Domains 1, 2 and 3, respectively. The mean ages of these zones suggest that subduction to UHP depths took place over 10-11 Ma and exhumation of the rocks occurred over a period of 19-20 Ma. Thus, subduction from - 55 km to 〉 160 km deep mantle depth took place at rates of approximately 9.5-10.5 km/Ma and exhumation from depths 〉160 km to the base of the crust at -30 km occurred at approximately 6.5 km/Ma. We propose a model for these rocks involving deep subduction of continental margin lithosphere followed by ultrafast exhumation driven by buoyancy forces after break-off of the UHP slab deep within the mantle.
文摘AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses.
基金Supported by Projects of Medical and Health Technology Development Program in Zhejiang Province(No.2011KYA020)
文摘AIM: To evaluate the positive effects of blue-violet light filtering lenses in delaying myopia and relieving asthenopia in juveniles. METHODS: Sixty ametropia juveniles (aged range, 11-15y) were randomized into two groups: the test group (30 children, 60 eyes), wearing blue-violet light filtering lenses; and the control group (30 children, 60 eyes), wearing ordinary aspherical lenses. Baseline refractive power of the affected eyes and axial length of the two groups was recorded. After 1-year, the patients underwent contrast sensitivity (glare and non-glare under bright and dark conditions), accommodation-related testing, asthenopia questionnaire assessment, and adverse reaction questionnaire assessment. RESULTS: After ly of wearing the filtering lenses, changes in refractive power and axial length were not significantly different between the two groups (P〉0.05). Under bright conditions, the contrast sensitivities at low and medium- frequency grating (vision angles of 6.3, 4.0, and 2.5) with glare in the test group were significantly higher than in the control group (P〈0.05), while the contrast sensitivity at low-frequency grating (vision angles of 6.3 and 4.0) in the absence of glare in the test group was higher than in the control group (P〈0.05). Under glare and non-glare dark conditions, the contrast sensitivities of various frequencies in the test group did not show significant differences compared with those in the control group (P〉0.05). In the test group, the amplitude of accommodation, accommodative lag, and accommodative sensitivity of patients wearing glasses for 6 and 12mo were significantly elevated (P〈0.05), while the asthenopia gratings were significantly decreased (P〈0.05). Nevertheless, in the control group,the amplitude of accommodation, accommodative lag, and accommodative sensitivity after 12mo were not significantly altered compared with baseline (P〉0.05), and the asthenopia grating was not significantly decreased (P〉0.05). In addition, after wearing glasses for 6 to 12mo, the asthenopia grating of patients in the test group decreased significantly compared with the control group (P〈0.05). At 12mo, the constituent ratio of adverse reactions did not show significant difference between the two groups (P〉0.05). CONCLUSION: A l-year follow-up reveal that compare with ordinary glasses, short-wavelength filtering lenses (blue/ violet-light filters) increase the low- and medium-frequency contrast sensitivity under bright conditions and improved accommodation. They effectively relieved asthenopia without severe adverse reactions, suggesting potential for clinical application. However, no significant advantages in terms of refractive power or axial length progression were found compared with ordinary aspheric lenses.
文摘·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·METHODS:This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL.IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients.Assessments included monocular and binocular distance vision,with and without best correction.Patients also completed surveys about their distance vision.·RESULTS:Preoperatively,the two study groups were similar in age,in distance visual acuity,and in the magnitude of corneal astigmatism.At 6 months postoperative,binocular uncorrected distance vision was 0.06?à0.14 logMAR in the AcrySof toric IOL group,significantly better than the 0.14?à0.11 logMAR in the spherical IOL group (P<0.05).For eyes with emmetropia as a target,the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes).No patients in the emmetropia/toric IOL group used distance glasses,as compared to 52% of patients in the emmetropia/spherical IOL group.All patients were satisfied or highly satisfied.Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05).·CONCLUSION:Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism.·
文摘AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.
文摘AIM: To compare the clinical performance of two types of silicon hydrogel contact lenses used as bandage lenses after LASEK surgery. METHODS: A prospective, double-masked study was conducted on 42 eyes of 21 patients who received binocular LASEK surgeries. The interocular difference in spherical equivalent power was less than -1.50D. Patients were randomly assigned to wear Galyfilcon A (Lens A) bandage contact lens in one eye and Balafilcon A (Lens B) in the fellow eye after the surgery. The responses to a subjective questionnaire on comfort of wearing, corneal epithelial status, conjunctival hyperemia, limbal neovascularization, lens fitting and contact lens debris were assessed 1 and 5 days postoperatively. Corneal endothelium was assessed before and 5 days after the surgery upon bandage lens removal. RESULTS: There was no difference between the two groups in terms of conjunctival hyperemia, limbal neovascularization, contact lens fitting, corneal epithelial status, corneal endothelium cell density (CD) and endothelium cell size (CS) at any postoperative visit. Complaints of discomfort, including foreign body sensation, pain and intolerance were statistically more among Lens B wearers at any postoperative visit (P < 0.05). Lens B appeared to attract much more debris than Lens A at the 5-day post-operative follow-up visit (P < 0.01). CONCLUSION: The two types of silicon hydrogel lenses investigated in this study demonstrated similar clinical performance in terms of corneal responses and lens fitting. However, Lens A showed a better performance in terms of comfort of wearing and deposit resistance.
基金A Foundation for the Author of National Excellent Doctoral Dissertation of PR China(No.10021201)
文摘AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam combined with low temperature and low pressure plasma, the surface characteristics of the IOLs including physical and optical properties were determined by the instruments of IOLs resolution, UV/VIS scanning spectrophotometer, contact angle measurement system, electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM). RESULTS: The color of titanium (Ti) modified IOLs was light yellow and that of titanium nitride (TiN) modified IOLs was light brown. The absorptive degree of ultraviolet rays and the hydrophilicity of the surfaces of modified IOLs were increased, and appeared suitable chemical compositions. The resolution of unmodified and modified IOLs reached normal standard. The surfaces of unmodified and Ti-modified IOLs appeared uniform. The surfaces of TIN-modified IOLs presented fine porcelain structure. CONCLUSION: The optical properties of all IOLs and the surface morphology of the modified IOLs were not affected by modification processes. The surface properties of the modified IOLs were improved.
文摘The crystalline lens is a transparent,biconvex structure in the eye that,along with the cornea,helps to refract light to be focused on the retina and,by changing shape,it adjusts focal distance(accommodation).The three classes of structural proteins found in the lens areα,β,and γ crystallins.These proteins make up more than 90% of the total dry mass of the eye lens.Other components which can be found are sugars,lipids,water,several antioxidants and low weight molecules.When ageing changes occur in the lens,it causes a gradual reduction in transparency,presbyopia and an increase in the scattering and aberration of light waves as well as a degradation of the optical quality of the eye.The main changes that occur with aging are: 1) reduced diffusion of water from the outside to the inside of the lens and from its cortical to its nuclear zone; 2)crystalline change due to the accumulation of high molecular weight aggregates and insoluble proteins; 3)production of advanced glycation end products(AGEs),lipid accumulation,reduction of reduced glutathione content and destruction of ascorbic acid.Even if effective strategies in preventing cataract onset are not already known,good results have been reached in some cases with oral administration of antioxidant substances such as caffeine,pyruvic acid,epigallocatechin gallate(EGCG),α-lipoic acid and ascorbic acid.Furthermore,methionine sulfoxide reductase A(MSRA) over expression could protect lens cells both in presence and in absence of oxidative stress-induced damage.Nevertheless,promising results have been obtained by reducing ultraviolet-induced oxidative damage.