期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
New Temperature Sensitive Genic Male Sterile Lines with Better Outcrossing Ability for Production of Two-Line Hybrid Rice 被引量:1
1
作者 S.J.ARASAKESARY S.MANONMANI +1 位作者 R.PUSHPAM S.ROBIN 《Rice science》 SCIE CSCD 2015年第1期49-52,共4页
An investigation was carried out with three newly developed temperature sensitive genic male sterile (TGMS) lines for their floral traits, seed production potential and outcrossing ability in ten cross combinations.... An investigation was carried out with three newly developed temperature sensitive genic male sterile (TGMS) lines for their floral traits, seed production potential and outcrossing ability in ten cross combinations. In the TGMS lines, fertile pollens had an average diameter of 0.89 mm while the sterile pollens was with 0.02 mm diameter.TS-29-150GY produced the biggest fertile pollens with 0.92 mm and other two lines produced relatively smaller pollens with 0.91 and 0.85 ram. Pollen fertility during the fertility reversion period was an average of 60.7%. TS-29-150GY had the maximum of 66.9% spikelet fertility whereas other two lines (TNAU18S and TNAU60S) had relatively lower spikelet fertility of 27.8% and 26.7%, respectively. Average of 17.00 g of seed yield was obtained in the TGMS lines during the fertility reversion period. TS-29- 150GY had the highest value of 21.20 g of seed yield while TNAU18S and TNAU60S produced 16.6 g and 13.2 g of seed yield, respectively. The low seed production ability of these three TGMS lines was attributed only to the environmental conditions prevailing during the period. All three TGMS lines had considerable outcrossing potential of 41.2%, 24.6% and 25.0%, respectively. The cross combinations viz. TNAU18S/IET21508 (36 g/plant), TNAU18S/IET21044 (13 g/plant), TNAU18S/IET21009 (26.5 g/plant), TNAU60S/CB-09-106 (26.2 g/plant), TNAU60S/IET21009 (14 g/plant) and TS29-150-GY/DRR 3306 (39.2 g/plant) showed perfect synchronization with acceptable hybrid seed yield, indicating suitability of TGMS system under Indian condition. Based on the outcrossing related traits viz. panicle exertion, angle of glume opening, stigma length and pollen size, TNAU18S was identified as the best, followed by TS-29-150GY. 展开更多
关键词 temperature sensitive genic male sterile line OUTCROSSING floral trait hybrid rice
下载PDF
Factors Influencing the Outcrossed Seed-Setting Obstacles of Photo-thermo Sensitive Genie Male Sterile Rice
2
作者 CHENXiong-hui WANBang-hui PENGHai-feng LUYan-peng LIAYGKe-qin ZHAOJing 《Rice science》 SCIE 2004年第3期113-119,共7页
Using photo-thermo sensitive genie male rice (PTGMS) Pei' ai 64S, W7415S, W6154S, N26S, Annong S, Nongken 58S, 7001S and 5088S as female parents and conventional indica lines 8258 and U89 as male parents, the fact... Using photo-thermo sensitive genie male rice (PTGMS) Pei' ai 64S, W7415S, W6154S, N26S, Annong S, Nongken 58S, 7001S and 5088S as female parents and conventional indica lines 8258 and U89 as male parents, the factors affecting outcrossed seed-setting were analyzed. The PTGMS had obstacles in outcrossed seed setting influenced by inheritance and environment at varying degrees. Environmental temperature was regarded as the main factor that resulted in the outcrossed seed-setting obstacles. The sensitive stage was at the early stage of grain filling for outcrossed seed setting. There existed remarkable differences at the sensitivity stage, the duration of sensitive period, the sensitive level and the effective level of outcrossed seed-setting obstacles caused by environmental temperature among different PTGMS lines. Therefore, attention should be paid to outcrossed seed-setting obstacles in selection and utilization of PTGMS lines. 展开更多
关键词 RICE photo-thermo sensitive genie male sterile line outcrossing seed setting rate temperature sensitive stage co-relationship
下载PDF
The Phenomenal Alleviation of Transmission Congestion by Optimally Placed Multiple Distributed Generators Using PSO
3
作者 Karuppasamy Muthulakshmi Rajamanickam Manickaraj Sasiraja Velu Suresh Kumar 《Circuits and Systems》 2016年第8期1677-1688,共13页
In the current electricity paradigm, the rapid elevation of demands in industrial sector and the process of restructuring are the main causes for the overuse of transmission systems. Hence, the evolution of novel tech... In the current electricity paradigm, the rapid elevation of demands in industrial sector and the process of restructuring are the main causes for the overuse of transmission systems. Hence, the evolution of novel technology is the ultimate need to avoid the damages in the available transmission systems. An appreciable volume of renewable energy sources is used to produce electric power, after the implementation of deregulation in power system. Even though, they are intended to improve the reliability of power system, the unpredictable outages of generators or transmission lines, an impulsive increase in demand and the sudden failures of vital equipment cause transmission congestion in one or some transmission lines. Generation rescheduling and load shedding can be used to alleviate congestion, but some cases require quite few improved methods. With the extensive application of Distributed Generation (DG), congestion management is also performed by the optimal placement of DGs. Therefore, this research employs a Line Flow Sensitivity Factor (LFSF) and Particle Swarm Optimization (PSO) for the determination of optimal location and size of multiple DG units, respectively. This proposed problem is formulated to minimize the total system losses and real power flow performance index. This approach is experimented in modified IEEE-30 bus test system. The results of N-1 contingency analysis with DG units prove the competence of this proposed approach, since the total numbers of congested lines get reduced from 15 to 2. Hence, the results show that the proposed approach is robust and simple in alleviating transmission congestion by the optimal placement and sizing of multiple DG units. 展开更多
关键词 Congestion Management line Flow Sensitivity Factor Distributed Generation Particle Swarm Optimization
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部