With a focus on an industrial multivariable system, two subsystems including the flow and the level outputs are analysed and controlled, which have applicability in both real and academic environments. In such a case,...With a focus on an industrial multivariable system, two subsystems including the flow and the level outputs are analysed and controlled, which have applicability in both real and academic environments. In such a case, at first, each subsystem is distinctively represented by its model, since the outcomes point out that the chosen models have the same behavior as corresponding ones. Then, the industrial multivariable system and its presentation are achieved in line with the integration of these subsystems, since the interaction between them can not actually be ignored. To analyze the interaction presented, the Gershgorin bands need to be acquired, where the results are used to modify the system parameters to appropriate values. Subsequently, in the view of modeling results, the control concept in two different techniques including sequential loop closing control(SLCC) scheme and diagonal dominance control(DDC) schemes is proposed to implement on the system through the Profibus network, as long as the OPC(OLE for process control) server is utilized to communicate between the control schemes presented and the multivariable system. The real test scenarios are carried out and the corresponding outcomes in their present forms are acquired. In the same way, the proposed control schemes results are compared with each other, where the real consequences verify the validity of them in the field of the presented industrial multivariable system control.展开更多
Sequential control applied to the International Thermonuclear Experimental Re- actor (ITER) poloidal field converter system for the purpose of reactive power reduction is the subject of this investigation. Due to th...Sequential control applied to the International Thermonuclear Experimental Re- actor (ITER) poloidal field converter system for the purpose of reactive power reduction is the subject of this investigation. Due to the inherent characteristics of thyristor-based phase-controlled converter, the poloidal field converter system consumes a huge amount of reactive power from the grid, which subsequently results in a voltage drop at the 66 kV busbar if no measure is taken. The installation of a static var compensator rated for 750 MVar at the 66 kV busbax is an essential way to compensate reactive power to the grid, which is the most effective measure to solve the problem. However, sequential control of the multi-series converters provides an additional method to improve the natural power factor and thus alleviate the pressure of reactive power demand of the converter system without any additional cost. In the present paper, by comparing with the symmetrical control technique, the advantage of sequential control in reactive power consumption is highlighted. Simulation results based on SIMULINK are found in agreement with the theoretical analysis.展开更多
Two-lap sequential control converters are usually adopted to supply and improve the power factor of input side. The line harmonic damage generated by a sequential control thyristor converter can be serious. To solve t...Two-lap sequential control converters are usually adopted to supply and improve the power factor of input side. The line harmonic damage generated by a sequential control thyristor converter can be serious. To solve this prob-lem and seek an optimum control strategy,we derived the changeable regular of the line-input-current,the fundamen-tal-frequency-current,the harmonic-current-content and the harmonic total distortion ratio of the converter at different firing angles. We obtained relevant data from experiments with a sequential control system of a DC 2.2kW/220V motor. With the example of the operating condition of a DC mine elevator,the harmonic current is two times approximately in sequential control compared to synchronous control when the firing angle of the two converters differs in 30°. At dif-ferent operating states of a two-lap connection converter,the ideal strategy is an exchange between sequential control and synchronous control,by which we can achieve the complementary goal of improving the power factor and har-monic effect. All analytical conclusions are supported by simulation and experimental results.展开更多
A design of the main AC/DC converter system for ITER is described and the configuration of the main AC/DC converters is presented. To reduce the reactive power absorbed from the converter units, the main AC/DC convert...A design of the main AC/DC converter system for ITER is described and the configuration of the main AC/DC converters is presented. To reduce the reactive power absorbed from the converter units, the main AC/DC converters are designed to be series-connected and work in a sequential mode. The structure of the regulator of the converter system is described. A simulation model was built up for the PSCAD/EMTDC code, and the design was validated accordingly. Harmonic analysis and reactive power calculation of the converters units are presented. The results reveal the advantage of sequential control in reducing reactive power and harmonics.展开更多
This paper investigates an analytical optimal pose tracking control problem for chaser spacecraft during the close-range proximity operations with a non-cooperative space target subject to attitude tumbling and unknow...This paper investigates an analytical optimal pose tracking control problem for chaser spacecraft during the close-range proximity operations with a non-cooperative space target subject to attitude tumbling and unknown orbital maneuvering.Firstly,the relative translational motion between the orbital target and the chaser spacecraft is described in the Line-of-Sight(LOS)coordinate frame along with attitude quaternion dynamics.Then,based on the coupled 6-Degree of Freedom(DOF)pose dynamic model,an analytical optimal control action consisting of constrained optimal control value,application time and its duration are proposed via exploring the iterative sequential action control algorithm.Meanwhile,the global closed-loop asymptotic stability of the proposed predictive control action is presented and discussed.Compared with traditional proximity control schemes,the highlighting advantages are that the application time and duration of the devised controller is applied discretely in light of the influence of the instantaneous pose configuration on the pose tracking performance with less energy consumptions rather than at each sample time.Finally,three groups of illustrative examples are organized to validate the effectiveness of the proposed analytical optimal pose tracking control scheme.展开更多
文摘With a focus on an industrial multivariable system, two subsystems including the flow and the level outputs are analysed and controlled, which have applicability in both real and academic environments. In such a case, at first, each subsystem is distinctively represented by its model, since the outcomes point out that the chosen models have the same behavior as corresponding ones. Then, the industrial multivariable system and its presentation are achieved in line with the integration of these subsystems, since the interaction between them can not actually be ignored. To analyze the interaction presented, the Gershgorin bands need to be acquired, where the results are used to modify the system parameters to appropriate values. Subsequently, in the view of modeling results, the control concept in two different techniques including sequential loop closing control(SLCC) scheme and diagonal dominance control(DDC) schemes is proposed to implement on the system through the Profibus network, as long as the OPC(OLE for process control) server is utilized to communicate between the control schemes presented and the multivariable system. The real test scenarios are carried out and the corresponding outcomes in their present forms are acquired. In the same way, the proposed control schemes results are compared with each other, where the real consequences verify the validity of them in the field of the presented industrial multivariable system control.
基金supported by International Cooperation Project of Ministry of Science and Technology of China(4.1.P2.CN.01/1A)
文摘Sequential control applied to the International Thermonuclear Experimental Re- actor (ITER) poloidal field converter system for the purpose of reactive power reduction is the subject of this investigation. Due to the inherent characteristics of thyristor-based phase-controlled converter, the poloidal field converter system consumes a huge amount of reactive power from the grid, which subsequently results in a voltage drop at the 66 kV busbar if no measure is taken. The installation of a static var compensator rated for 750 MVar at the 66 kV busbax is an essential way to compensate reactive power to the grid, which is the most effective measure to solve the problem. However, sequential control of the multi-series converters provides an additional method to improve the natural power factor and thus alleviate the pressure of reactive power demand of the converter system without any additional cost. In the present paper, by comparing with the symmetrical control technique, the advantage of sequential control in reactive power consumption is highlighted. Simulation results based on SIMULINK are found in agreement with the theoretical analysis.
基金Project GC06A523 supported by the Science and Technology Department of Heilongjiang Province
文摘Two-lap sequential control converters are usually adopted to supply and improve the power factor of input side. The line harmonic damage generated by a sequential control thyristor converter can be serious. To solve this prob-lem and seek an optimum control strategy,we derived the changeable regular of the line-input-current,the fundamen-tal-frequency-current,the harmonic-current-content and the harmonic total distortion ratio of the converter at different firing angles. We obtained relevant data from experiments with a sequential control system of a DC 2.2kW/220V motor. With the example of the operating condition of a DC mine elevator,the harmonic current is two times approximately in sequential control compared to synchronous control when the firing angle of the two converters differs in 30°. At dif-ferent operating states of a two-lap connection converter,the ideal strategy is an exchange between sequential control and synchronous control,by which we can achieve the complementary goal of improving the power factor and har-monic effect. All analytical conclusions are supported by simulation and experimental results.
文摘A design of the main AC/DC converter system for ITER is described and the configuration of the main AC/DC converters is presented. To reduce the reactive power absorbed from the converter units, the main AC/DC converters are designed to be series-connected and work in a sequential mode. The structure of the regulator of the converter system is described. A simulation model was built up for the PSCAD/EMTDC code, and the design was validated accordingly. Harmonic analysis and reactive power calculation of the converters units are presented. The results reveal the advantage of sequential control in reducing reactive power and harmonics.
基金This study was co-supported by the National Natural Science Foundation of China(Nos.62003371,62373379,62103446,61273351,62073343)the Outstanding Youth Fund of Hunan Provincial Natural Science,China(No.2022JJ20081)the Innovation Driven Project of Central South University,China(No.2023CXQD066).
文摘This paper investigates an analytical optimal pose tracking control problem for chaser spacecraft during the close-range proximity operations with a non-cooperative space target subject to attitude tumbling and unknown orbital maneuvering.Firstly,the relative translational motion between the orbital target and the chaser spacecraft is described in the Line-of-Sight(LOS)coordinate frame along with attitude quaternion dynamics.Then,based on the coupled 6-Degree of Freedom(DOF)pose dynamic model,an analytical optimal control action consisting of constrained optimal control value,application time and its duration are proposed via exploring the iterative sequential action control algorithm.Meanwhile,the global closed-loop asymptotic stability of the proposed predictive control action is presented and discussed.Compared with traditional proximity control schemes,the highlighting advantages are that the application time and duration of the devised controller is applied discretely in light of the influence of the instantaneous pose configuration on the pose tracking performance with less energy consumptions rather than at each sample time.Finally,three groups of illustrative examples are organized to validate the effectiveness of the proposed analytical optimal pose tracking control scheme.