To obtain higher accurate position estimates, the stochastic model is estimated by using residual of observations, hence, the stochastic model describes the noise and bias in measurements more realistically. By using ...To obtain higher accurate position estimates, the stochastic model is estimated by using residual of observations, hence, the stochastic model describes the noise and bias in measurements more realistically. By using GPS data and broadcast ephemeris, the numerical results indicating the accurate position estimates at sub-meter level are obtainable.展开更多
Objective: The study aimed to evaluate the genotypic profiles of C. albicans (Candida albicans) sequentially isolated throughout the course of HIV infections, and to determine its MIC (minimal inhibitory concentra...Objective: The study aimed to evaluate the genotypic profiles of C. albicans (Candida albicans) sequentially isolated throughout the course of HIV infections, and to determine its MIC (minimal inhibitory concentrations) to AMB (amphotericin B), FLC (fluconazole), KTC (ketoconazole), and ITC (itraconazole). Design: samples were collected from the oral cavity of HIV-positive individuals during 4 years, with a sterilized swab. MIC was performed by using the microdilution method AFST/EUCAST. The genetic similarities within and between sequential clones of C. albicans were assessed by DNA fingerprinting using the random amplification ofpolymorphic DNA technique. Results: A total of 142 oral samples were isolated from 59 HIV-infected individuals who attempted up to five visits each, with or without symptoms of oropharyngeal candidiasis. Profile analysis revealed that yeasts isolated over sequential visits from symptomatic or asymptomatic individuals showed 78% or 87% relatedness, respectively. The degree of similarity among C. albicans was higher for isolates from colonization than for those from infection. Genetically identical C. albicans samples also formed connected subelusters in sequential visits. In regard to susceptibility profile, all isolates were susceptible to AMB, FLC, KTC, and ITC and maintained this pattern all along, no differences in MICs of any given antifungal compound were observed for sequential C. albicans isolates. Conclusions: These data suggest that genotype and susceptibility to antifimgal drugs were maintained over time in sequentially isolates of C. albicans colonization and a diverse evolutionary genetic trend in C. albicans sequentially isolated from the oral eandidiasis of HIV infected individuals.展开更多
The conventional technique for positioning seafloor geophones in ocean bottom seismic exploration encounters several challenges,including the significant impact of outliers on positioning results,underutilization of h...The conventional technique for positioning seafloor geophones in ocean bottom seismic exploration encounters several challenges,including the significant impact of outliers on positioning results,underutilization of high-precision observations,and low efficiency in real-time data processing.These issues inevitably affect the quality of seismic exploration outcomes.To address these challenges and enhance the accuracy of geophone positioning,this paper proposes a rigorous real-time acoustic positioning method for geophones based on sequential adjustment and Baarda's outlier detection approach.The proposed method comprises three key steps:grouping the original acoustic observations,constructing the intra-group acoustic positioning model,and synthesizing the positioning results across the different groups.The validity and practicality of this approach are confirmed through a simulation experiment as well as the field experiment conducted in the Bohai Sea,China.The results demonstrate that the proposed method effectively eliminates outliers in the original observations and maximizes the utilization of high-quality observations.Compared to traditional acoustic positioning methods,it significantly reduces positioning errors from meters to decimeters,and in some cases can achieve centimeter-level precision.When the sound velocity profile in the operating sea area is measured,the method can attain the posterior standard deviation at the millimeter level and positioning errors within 10 cm.When the sound velocity profile is unknown,the method can achieve the posterior standard deviation at centimeter-level and positioning errors of approximately 20 cm.展开更多
基金Supported by the National 863 Program of China (No.2006AA12Z325) and the National Natural Science Foundation of China (No.40274005).
文摘To obtain higher accurate position estimates, the stochastic model is estimated by using residual of observations, hence, the stochastic model describes the noise and bias in measurements more realistically. By using GPS data and broadcast ephemeris, the numerical results indicating the accurate position estimates at sub-meter level are obtainable.
文摘Objective: The study aimed to evaluate the genotypic profiles of C. albicans (Candida albicans) sequentially isolated throughout the course of HIV infections, and to determine its MIC (minimal inhibitory concentrations) to AMB (amphotericin B), FLC (fluconazole), KTC (ketoconazole), and ITC (itraconazole). Design: samples were collected from the oral cavity of HIV-positive individuals during 4 years, with a sterilized swab. MIC was performed by using the microdilution method AFST/EUCAST. The genetic similarities within and between sequential clones of C. albicans were assessed by DNA fingerprinting using the random amplification ofpolymorphic DNA technique. Results: A total of 142 oral samples were isolated from 59 HIV-infected individuals who attempted up to five visits each, with or without symptoms of oropharyngeal candidiasis. Profile analysis revealed that yeasts isolated over sequential visits from symptomatic or asymptomatic individuals showed 78% or 87% relatedness, respectively. The degree of similarity among C. albicans was higher for isolates from colonization than for those from infection. Genetically identical C. albicans samples also formed connected subelusters in sequential visits. In regard to susceptibility profile, all isolates were susceptible to AMB, FLC, KTC, and ITC and maintained this pattern all along, no differences in MICs of any given antifungal compound were observed for sequential C. albicans isolates. Conclusions: These data suggest that genotype and susceptibility to antifimgal drugs were maintained over time in sequentially isolates of C. albicans colonization and a diverse evolutionary genetic trend in C. albicans sequentially isolated from the oral eandidiasis of HIV infected individuals.
基金supported by the National Key R&D Program of China(Grant No.:2016YFB0501703)Science and Technology Innovation Project(Grant No.:LSKJ202205102)Funded by Laoshan Laboratory.
文摘The conventional technique for positioning seafloor geophones in ocean bottom seismic exploration encounters several challenges,including the significant impact of outliers on positioning results,underutilization of high-precision observations,and low efficiency in real-time data processing.These issues inevitably affect the quality of seismic exploration outcomes.To address these challenges and enhance the accuracy of geophone positioning,this paper proposes a rigorous real-time acoustic positioning method for geophones based on sequential adjustment and Baarda's outlier detection approach.The proposed method comprises three key steps:grouping the original acoustic observations,constructing the intra-group acoustic positioning model,and synthesizing the positioning results across the different groups.The validity and practicality of this approach are confirmed through a simulation experiment as well as the field experiment conducted in the Bohai Sea,China.The results demonstrate that the proposed method effectively eliminates outliers in the original observations and maximizes the utilization of high-quality observations.Compared to traditional acoustic positioning methods,it significantly reduces positioning errors from meters to decimeters,and in some cases can achieve centimeter-level precision.When the sound velocity profile in the operating sea area is measured,the method can attain the posterior standard deviation at the millimeter level and positioning errors within 10 cm.When the sound velocity profile is unknown,the method can achieve the posterior standard deviation at centimeter-level and positioning errors of approximately 20 cm.