Background Recent advances in serial femtosecond crystallography(SFX)using X-ray free electron lasers(XFELs)have facilitated accurate structure determination for biological macromolecules.However,given the many fluctu...Background Recent advances in serial femtosecond crystallography(SFX)using X-ray free electron lasers(XFELs)have facilitated accurate structure determination for biological macromolecules.However,given the many fluctuations inherent in SFX,the acquisition of SFX data of sufficiently high quality still remains challenging.Method Aimed at enhancing the accuracy of SFX data,this study proposes an iterative refinement method to optimally match pairs of the observed and predicted reflections on the detector plane.This method features a combination of detector geometry optimization and diffraction model refinement in an alternate manner,concomitant with a cycle-by-cycle peak selection procedure.Result To demonstrate whether this iterative method is convergent and feasible,both numerical simulations and experimental tests have been performed.The results reveal that this method can gradually improve overall quality of the integrated SFX data and therefore accelerate the convergence of Monte Carlo integration,while simultaneously suppressing correlations inherent in certain parameters and precluding outliers to some extent during the refinement.Conclusion We have demonstrated that our iterative refinement method is applicable to both simulated and experimental SFX data.It is expected that this method could provide meaningful insights into the refinement of SFX data and take the step forward toward more accurate Monte Carlo integration.展开更多
This paper provides a review on sample injectors which are provided at SPring-8 Angstrom Compact free electron LAser(SACLA) for conducting serial measurement in a ‘diffract-before-destroy' scheme using an x-ray f...This paper provides a review on sample injectors which are provided at SPring-8 Angstrom Compact free electron LAser(SACLA) for conducting serial measurement in a ‘diffract-before-destroy' scheme using an x-ray free electron laser(XFEL). Versatile experimental platforms at SACLA are able to accept various types of injectors, among which liquidjet, droplet and viscous carrier injectors are frequently utilized. These injectors produce different forms of fluid targets such as a liquid filament with a diameter in the order of micrometer, micro-droplet synchronized to XFEL pulses, and slowly flowing column of highly viscous fluid with a rate below 1 μL min-1. Characteristics and applications of the injectors are described.展开更多
基金This work was financially supported by the grants from the Strategic Priority Research Program of CAS(XDB08030103)the National Natural Science Foundation of China(31570744,31670059).
文摘Background Recent advances in serial femtosecond crystallography(SFX)using X-ray free electron lasers(XFELs)have facilitated accurate structure determination for biological macromolecules.However,given the many fluctuations inherent in SFX,the acquisition of SFX data of sufficiently high quality still remains challenging.Method Aimed at enhancing the accuracy of SFX data,this study proposes an iterative refinement method to optimally match pairs of the observed and predicted reflections on the detector plane.This method features a combination of detector geometry optimization and diffraction model refinement in an alternate manner,concomitant with a cycle-by-cycle peak selection procedure.Result To demonstrate whether this iterative method is convergent and feasible,both numerical simulations and experimental tests have been performed.The results reveal that this method can gradually improve overall quality of the integrated SFX data and therefore accelerate the convergence of Monte Carlo integration,while simultaneously suppressing correlations inherent in certain parameters and precluding outliers to some extent during the refinement.Conclusion We have demonstrated that our iterative refinement method is applicable to both simulated and experimental SFX data.It is expected that this method could provide meaningful insights into the refinement of SFX data and take the step forward toward more accurate Monte Carlo integration.
基金supported by the X-ray FreeElectron Laser Priority Strategy Program (MEXT)JSPS KAKENHI Grant Number 15K05407
文摘This paper provides a review on sample injectors which are provided at SPring-8 Angstrom Compact free electron LAser(SACLA) for conducting serial measurement in a ‘diffract-before-destroy' scheme using an x-ray free electron laser(XFEL). Versatile experimental platforms at SACLA are able to accept various types of injectors, among which liquidjet, droplet and viscous carrier injectors are frequently utilized. These injectors produce different forms of fluid targets such as a liquid filament with a diameter in the order of micrometer, micro-droplet synchronized to XFEL pulses, and slowly flowing column of highly viscous fluid with a rate below 1 μL min-1. Characteristics and applications of the injectors are described.