Sprague-Dawley male rats were divided into groups and maintained on a semipurified diet containing either 5 or 40 ppm of zinc or 2 or 8 ppm of copper. Half of the rats in each group received 1000 ppm aluminum in the d...Sprague-Dawley male rats were divided into groups and maintained on a semipurified diet containing either 5 or 40 ppm of zinc or 2 or 8 ppm of copper. Half of the rats in each group received 1000 ppm aluminum in the diet. It was found that aluminum accumulated in the pituitary glands and testes when dietary copper levels were suboptimal. The ALP activity in testes was depressed by the added aluminum when the intake of zinc or copper was suboptimal. SDH, LDH, and LDH-X activities were inhibited and GRS and GGTP activities were elevated in rats fed either the suboptimal zinc or copper diet. However, the added aluminum in the diet reversed the changes to normal levels. The testosterone levels in plasma changed very little when the zinc or copper intake was suboptimal. An increase in plasma FSH was demonstrated in groups of both suboptimal zinc and copper intake. But the plasma LH was elevated only in the group receiving the suboptimal copper diet, and the added aluminum reversed plasma LH to control levels. A lower level of testosterone was demonstrated in the group given suboptimal copper with aluminum. It was concluded that dietary aluminum influenced the pituitary-testicular axis by interacting with certain essential trace metals, particularly zinc. 1990 Academic Press. Inc.展开更多
After primary analyses on the serum glycocon-jugates of lung cancer and normal individul using the enzyme-linked lectin assay (ELLA) with 12 kinds of lectins, PHA and LCA were selected to further study in the sera of ...After primary analyses on the serum glycocon-jugates of lung cancer and normal individul using the enzyme-linked lectin assay (ELLA) with 12 kinds of lectins, PHA and LCA were selected to further study in the sera of 8 kinds of cancers, 4 kinds of non-malignant disease and 1 kind of postoperative cancer. It was found that the test values of 7 kinds of cancers with PHA or LCA were significantly higher than that of the normal (P<0.01); the values of 4 kinds of non-malignant diseases with PHA were not higher (P>0.05); the values of the postoperative cancer with PHA were obviously lower than that of the preoperative (P<0.05). The results showed that the serum glycoconjugates which can bind to PHA seemed related to the cancerous existence in human bodies. The significance of the findings was discussed.展开更多
Objective To explore a highly sensitive and highly specific method to detect the serum MG7 antigen(Ag)level for early gastric cancer diagnosis.Methods The serum MG7-Ag level was detected by enzyme-linked immunosorbent...Objective To explore a highly sensitive and highly specific method to detect the serum MG7 antigen(Ag)level for early gastric cancer diagnosis.Methods The serum MG7-Ag level was detected by enzyme-linked immunosorbent assay(ELISA)method in 116 preoperative gastric cancer patients,63 postoperative gastric cancer patients,41 patients with precancerous lesion,37 pa-展开更多
At 0.12 mmol/L γ-glutamyl p-nitroaniline(GGPNA),an improved integrated method was developed for kinetic analysis of γ-glutamyltransferase(GGT) reaction process and the integration with the classical initial rate met...At 0.12 mmol/L γ-glutamyl p-nitroaniline(GGPNA),an improved integrated method was developed for kinetic analysis of γ-glutamyltransferase(GGT) reaction process and the integration with the classical initial rate method to measure serum GGT.For the improved integrated method,an integrated rate equation,which used the predictor variable of reaction time and considered inhibitions by both GGPNA and products,was nonlinearly fit to GGT reaction processes.For the integration strategy,classical initial rates were estimated when GGPNA consumption percentages were below 50%;otherwise,maximal reaction rates of GGT were estimated by the improved integrated method and converted into initial rates according to the differential rate equation at 0.11 mmol/L GGPNA.The inte-gration strategy was validated using optimized GGT kinetic parameters and 10-s intervals to record reaction curves within 8.0 min.By the integration strategy,there was a linear response from 0.9 to 32.0 U/L GGT,coefficients of variation were below 3.5%for GGT from 8.0 to 32.0 U/L(n=5) ,and GGT activities in clinical sera responded linearly to their classical initial rates at 2.00 mmol/L GGPNA with an expected slope.Therefore,the integration strategy was successful in measuring GGT at 0.12 mmol/L GGPNA.展开更多
文摘Sprague-Dawley male rats were divided into groups and maintained on a semipurified diet containing either 5 or 40 ppm of zinc or 2 or 8 ppm of copper. Half of the rats in each group received 1000 ppm aluminum in the diet. It was found that aluminum accumulated in the pituitary glands and testes when dietary copper levels were suboptimal. The ALP activity in testes was depressed by the added aluminum when the intake of zinc or copper was suboptimal. SDH, LDH, and LDH-X activities were inhibited and GRS and GGTP activities were elevated in rats fed either the suboptimal zinc or copper diet. However, the added aluminum in the diet reversed the changes to normal levels. The testosterone levels in plasma changed very little when the zinc or copper intake was suboptimal. An increase in plasma FSH was demonstrated in groups of both suboptimal zinc and copper intake. But the plasma LH was elevated only in the group receiving the suboptimal copper diet, and the added aluminum reversed plasma LH to control levels. A lower level of testosterone was demonstrated in the group given suboptimal copper with aluminum. It was concluded that dietary aluminum influenced the pituitary-testicular axis by interacting with certain essential trace metals, particularly zinc. 1990 Academic Press. Inc.
文摘After primary analyses on the serum glycocon-jugates of lung cancer and normal individul using the enzyme-linked lectin assay (ELLA) with 12 kinds of lectins, PHA and LCA were selected to further study in the sera of 8 kinds of cancers, 4 kinds of non-malignant disease and 1 kind of postoperative cancer. It was found that the test values of 7 kinds of cancers with PHA or LCA were significantly higher than that of the normal (P<0.01); the values of 4 kinds of non-malignant diseases with PHA were not higher (P>0.05); the values of the postoperative cancer with PHA were obviously lower than that of the preoperative (P<0.05). The results showed that the serum glycoconjugates which can bind to PHA seemed related to the cancerous existence in human bodies. The significance of the findings was discussed.
文摘Objective To explore a highly sensitive and highly specific method to detect the serum MG7 antigen(Ag)level for early gastric cancer diagnosis.Methods The serum MG7-Ag level was detected by enzyme-linked immunosorbent assay(ELISA)method in 116 preoperative gastric cancer patients,63 postoperative gastric cancer patients,41 patients with precancerous lesion,37 pa-
基金Project supported by the National Natural Science Foundation of China (No.30200266)the Program for New Century Excellent Talents in University of Ministry of Education of China(No.NCET-09-928)
文摘At 0.12 mmol/L γ-glutamyl p-nitroaniline(GGPNA),an improved integrated method was developed for kinetic analysis of γ-glutamyltransferase(GGT) reaction process and the integration with the classical initial rate method to measure serum GGT.For the improved integrated method,an integrated rate equation,which used the predictor variable of reaction time and considered inhibitions by both GGPNA and products,was nonlinearly fit to GGT reaction processes.For the integration strategy,classical initial rates were estimated when GGPNA consumption percentages were below 50%;otherwise,maximal reaction rates of GGT were estimated by the improved integrated method and converted into initial rates according to the differential rate equation at 0.11 mmol/L GGPNA.The inte-gration strategy was validated using optimized GGT kinetic parameters and 10-s intervals to record reaction curves within 8.0 min.By the integration strategy,there was a linear response from 0.9 to 32.0 U/L GGT,coefficients of variation were below 3.5%for GGT from 8.0 to 32.0 U/L(n=5) ,and GGT activities in clinical sera responded linearly to their classical initial rates at 2.00 mmol/L GGPNA with an expected slope.Therefore,the integration strategy was successful in measuring GGT at 0.12 mmol/L GGPNA.