Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running...Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range.展开更多
To further clarify the distribution mechanism of polycyclic aromatic hydrocarbons (PAHs) which cause damage to human and ecosystem health,the differences between 15 kinds of PAHs in Meizhou Bay coastal zones in terms ...To further clarify the distribution mechanism of polycyclic aromatic hydrocarbons (PAHs) which cause damage to human and ecosystem health,the differences between 15 kinds of PAHs in Meizhou Bay coastal zones in terms of the concentration,spatial distribution and sources,especially the ocean area around drainage outlets of sewage treatment plants,were fully investigated.The results indicated that the total concentration of 15 kinds of PAHs at each sampling station ranged from 27.2 to 774.2 ng/L.PAHs in Meizhou Bay coastal zones decreased as follows:4-ring>3-ring>5-ring>6-ring.As for the ∑PAHs,the concentration increased from the reference ocean area,affected ocean area to the mixed ocean area.Furthermore,the concentration of PAHs in the bottom area was obviously larger than that in the surface layer,indicating that the concentration of PAHs with various rings varied significantly in different ocean areas.The concentration of ∑PAHs had no significant correlation with water quality parameters such as temperature,salinity,pH and so on.In addition,PAHs in the mixed ocean area derived from fossil fuel,while PAHs in the affected ocean area and reference ocean area were mainly from fossil fuel and oil.展开更多
Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditio...Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%.展开更多
Over the years,the Shaying River Basin has experienced frequent instances of river pollution.The presence of numerous critical pollutant discharge enterprises and sewage-treatment plants in the vicinity of the Shaying...Over the years,the Shaying River Basin has experienced frequent instances of river pollution.The presence of numerous critical pollutant discharge enterprises and sewage-treatment plants in the vicinity of the Shaying River has transformed it a major tributary with relatively serious pollution challenge within the upper reaches of Huaihe River Basin.To study the sources of manganese(Mn),chromium(Cr),nickel(Ni),arsenic(As),cadmium(Cd)and lead(Pb)in Shaying River water,123 sets of surface water samples were collected from 41 sampling points across the entire basin during three distinct phases from 2019 to 2020,encompassing normal water period,dry season and wet season.The primary origins of heavy metals in river water were determined by analyzing the heavy metal contents in urban sewage wastewater,industrial sewage wastewater,groundwater,mine water,and the heavy metal contributions from agricultural non-point source pollution.The analytical findings reveal that Mn primarily originates from shallow groundwater used for agricultural irrigation,While Cr mainly is primarily sourced from urban sewage treatment plant effluents,coal washing wastewater,tannery wastewater,and industrial discharge related to metal processing and manufacturing.Ni is mainly contributed by urban sewage treatment plant effluents and industrial wastewater streams associated with machinery manufacturing and metal processing.Cd primarily linked to industrial wastewater,particularly from machinery manufacturing and metal processing facilities,while Pb is predominantly associated with urban sewage treatment plant effluents and wastewater generated in Pb processing and recycling wastewater.These research provides a crucial foundation for addressing the prevention and control of dissolved heavy metals at their sources in the Shaying River.展开更多
A metropolitan city such as Los Angeles (LA) is an ideal study site with a very high population density, and it houses at least 3 treatment plants where sewage is treated preliminarily and then progressing to tertiary...A metropolitan city such as Los Angeles (LA) is an ideal study site with a very high population density, and it houses at least 3 treatment plants where sewage is treated preliminarily and then progressing to tertiary treatment before discharging into the LA River. We will gain a better understanding of the water quality in the LA River and the nitrate load in the watershed system by examining the influence of waste water treatment plants (WWTPs). The goal of this study is to pinpoint the exact source of nitrate in the LA River using the isotope signatures. We have selected sampling locations both upstream and downstream of the WWTP. This serves to monitor nitrate levels, aiding in the assessment of treatment plant effectiveness, pinpointing nitrate pollution sources, and ensuring compliance with environmental regulations. The research explores the isotopic composition of NO3 in relation to atmospheric nitrogen and Vienna Standard Mean Ocean Water, shedding light on the contributions from various sources such as manure, sewage, soil organic nitrogen, and nitrogen fertilizers. Specifically, there is a change in the δ15NAir value between the dry and wet seasons. The isotope values in the Tillman WWTP sample changed between dry and wet seasons. Notably, the presence of nitrate originating from manure and sewage is consistent across seasons, emphasizing the significant impact of anthropogenic and agricultural activities on water quality. This investigation contributes to the broader understanding of nitrogen cycling in urban water bodies, particularly in the context of wastewater effluent discharge. The findings hold implications for water quality management and highlight the need for targeted interventions to mitigate the impact of nitrogen-containing compounds on aquatic ecosystems. Overall, the study provides a valuable framework for future research and environmental stewardship efforts aimed at preserving the health and sustainability of urban water resources. This data informs decisions regarding additional treatment or mitigation actions to safeguard downstream water quality and ecosystem health.展开更多
基金Supported by National Natural Science Foundation of China (No. 50578048)"Heating, Gas, Ventilation and Air Conditioning" Key Laboratory Open Subject in Beijing (No. KF200710)the Postdoctoral Researcher Science Foundation of China (No. 20090450986)
文摘Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multiple units but different parallel operation models, and the operation characteristics of units were analyzed as well. Results show that the single screw water-source heat pump can maintain high COP only at 60%—100% load ratio, COP decreases sharply with the decrease of load ratio, and the units with parallel operation are controlled by the load ratio of a single unit according to the reduction of total load which can keep the average COP at high level within a wide load range.
基金Supported by Key Laboratory of Integrated Marine Monitoring Technology and Applied Technologies for Harmful Algal Blooms,State Oceanic Administration(MATHAB201802)
文摘To further clarify the distribution mechanism of polycyclic aromatic hydrocarbons (PAHs) which cause damage to human and ecosystem health,the differences between 15 kinds of PAHs in Meizhou Bay coastal zones in terms of the concentration,spatial distribution and sources,especially the ocean area around drainage outlets of sewage treatment plants,were fully investigated.The results indicated that the total concentration of 15 kinds of PAHs at each sampling station ranged from 27.2 to 774.2 ng/L.PAHs in Meizhou Bay coastal zones decreased as follows:4-ring>3-ring>5-ring>6-ring.As for the ∑PAHs,the concentration increased from the reference ocean area,affected ocean area to the mixed ocean area.Furthermore,the concentration of PAHs in the bottom area was obviously larger than that in the surface layer,indicating that the concentration of PAHs with various rings varied significantly in different ocean areas.The concentration of ∑PAHs had no significant correlation with water quality parameters such as temperature,salinity,pH and so on.In addition,PAHs in the mixed ocean area derived from fossil fuel,while PAHs in the affected ocean area and reference ocean area were mainly from fossil fuel and oil.
基金the Science and Technology Program Project of the Ministry of Housing and Urban-Rural Development“Research on Indoor Thermal Environment Based on Zero Energy Building Technology in Hot Summer and Cold Winter Area”(2017-K1-014)Hubei Provincial Natural Fund Youth Fund“Technology and Evaluation of Multi-energy Complementary Energy Supply for Rural Residential Buildings in Hubei”(2017CFB311).
文摘Based on the characteristics of sewage from beauty salons,a simulation model of a small sewage source heat pump triple supply system that can be applied to such places is established to optimize the operating conditions of the system.The results show that with the increase of sewage temperature and flow,the performance of the system also increases.In summer conditions,the system provides cooling,recovers waste heat and condensed heat from sewage,with a COP value of 8.97;in winter conditions,the system heats and produces hot water,with a COP value of 2.44;in transitional seasons,only hot water is produced.The COP value is 2.75.Compared with the traditional systems which refers to the air source heat pump and hot water boiler system currently used in beauty salons,this system can save energy by 50.9%.
基金funded and supported by the Youth Science and Technology Project of Henan Provincial Bureau of Geology and Mineral Resources,YDKQKC[2008]No.8.
文摘Over the years,the Shaying River Basin has experienced frequent instances of river pollution.The presence of numerous critical pollutant discharge enterprises and sewage-treatment plants in the vicinity of the Shaying River has transformed it a major tributary with relatively serious pollution challenge within the upper reaches of Huaihe River Basin.To study the sources of manganese(Mn),chromium(Cr),nickel(Ni),arsenic(As),cadmium(Cd)and lead(Pb)in Shaying River water,123 sets of surface water samples were collected from 41 sampling points across the entire basin during three distinct phases from 2019 to 2020,encompassing normal water period,dry season and wet season.The primary origins of heavy metals in river water were determined by analyzing the heavy metal contents in urban sewage wastewater,industrial sewage wastewater,groundwater,mine water,and the heavy metal contributions from agricultural non-point source pollution.The analytical findings reveal that Mn primarily originates from shallow groundwater used for agricultural irrigation,While Cr mainly is primarily sourced from urban sewage treatment plant effluents,coal washing wastewater,tannery wastewater,and industrial discharge related to metal processing and manufacturing.Ni is mainly contributed by urban sewage treatment plant effluents and industrial wastewater streams associated with machinery manufacturing and metal processing.Cd primarily linked to industrial wastewater,particularly from machinery manufacturing and metal processing facilities,while Pb is predominantly associated with urban sewage treatment plant effluents and wastewater generated in Pb processing and recycling wastewater.These research provides a crucial foundation for addressing the prevention and control of dissolved heavy metals at their sources in the Shaying River.
文摘A metropolitan city such as Los Angeles (LA) is an ideal study site with a very high population density, and it houses at least 3 treatment plants where sewage is treated preliminarily and then progressing to tertiary treatment before discharging into the LA River. We will gain a better understanding of the water quality in the LA River and the nitrate load in the watershed system by examining the influence of waste water treatment plants (WWTPs). The goal of this study is to pinpoint the exact source of nitrate in the LA River using the isotope signatures. We have selected sampling locations both upstream and downstream of the WWTP. This serves to monitor nitrate levels, aiding in the assessment of treatment plant effectiveness, pinpointing nitrate pollution sources, and ensuring compliance with environmental regulations. The research explores the isotopic composition of NO3 in relation to atmospheric nitrogen and Vienna Standard Mean Ocean Water, shedding light on the contributions from various sources such as manure, sewage, soil organic nitrogen, and nitrogen fertilizers. Specifically, there is a change in the δ15NAir value between the dry and wet seasons. The isotope values in the Tillman WWTP sample changed between dry and wet seasons. Notably, the presence of nitrate originating from manure and sewage is consistent across seasons, emphasizing the significant impact of anthropogenic and agricultural activities on water quality. This investigation contributes to the broader understanding of nitrogen cycling in urban water bodies, particularly in the context of wastewater effluent discharge. The findings hold implications for water quality management and highlight the need for targeted interventions to mitigate the impact of nitrogen-containing compounds on aquatic ecosystems. Overall, the study provides a valuable framework for future research and environmental stewardship efforts aimed at preserving the health and sustainability of urban water resources. This data informs decisions regarding additional treatment or mitigation actions to safeguard downstream water quality and ecosystem health.