Stuck up and fracture of coronary angioplasty hardware are unwonted complications of percutaneous coronary interventions (PCI) for which surgical retrieval and management is once in a while required. We present one ca...Stuck up and fracture of coronary angioplasty hardware are unwonted complications of percutaneous coronary interventions (PCI) for which surgical retrieval and management is once in a while required. We present one case of a 59-year-old diabetic, a hypertensive gentleman who attended the emergency room (ER) with central chest pain for 2 hours. After evaluation of the patient <span>by physical and noninvasive diagnostic tests, he was diagnosed as a case of</span> acute myocardial infarction (AMI) with stable hemodynamic. For the aforementioned findings, the patient was treated first with a thrombolytic agent in <span>ER and then shifted to Cardiology Department for monitoring and further</span> <span>coronary evaluation by coronary angiography (CAG). CAG revealed essen</span><span>tially single vessel disease (SVD) with complex left anterior descending (LAD) </span>artery lesion, so PCI was attempted but failed with an unfortunate incidence of the broken delivery shaft and left <i>in vivo</i>. Immediate decision making and <span>surgical management for retrieval of lost angioplasty device and correction</span> coronary lesion with revascularization save the patient from grave complica<span>tion. All the series of events and management approaches of this very com</span>plex coronary artery lesion are discussed in this article.展开更多
文摘Stuck up and fracture of coronary angioplasty hardware are unwonted complications of percutaneous coronary interventions (PCI) for which surgical retrieval and management is once in a while required. We present one case of a 59-year-old diabetic, a hypertensive gentleman who attended the emergency room (ER) with central chest pain for 2 hours. After evaluation of the patient <span>by physical and noninvasive diagnostic tests, he was diagnosed as a case of</span> acute myocardial infarction (AMI) with stable hemodynamic. For the aforementioned findings, the patient was treated first with a thrombolytic agent in <span>ER and then shifted to Cardiology Department for monitoring and further</span> <span>coronary evaluation by coronary angiography (CAG). CAG revealed essen</span><span>tially single vessel disease (SVD) with complex left anterior descending (LAD) </span>artery lesion, so PCI was attempted but failed with an unfortunate incidence of the broken delivery shaft and left <i>in vivo</i>. Immediate decision making and <span>surgical management for retrieval of lost angioplasty device and correction</span> coronary lesion with revascularization save the patient from grave complica<span>tion. All the series of events and management approaches of this very com</span>plex coronary artery lesion are discussed in this article.