In order to solve the lack of relevant evaluation research on the accuracy of HMP155A humidity sensor calibration results in the past, this paper designs the corresponding experimental scheme, and obtains the correspo...In order to solve the lack of relevant evaluation research on the accuracy of HMP155A humidity sensor calibration results in the past, this paper designs the corresponding experimental scheme, and obtains the corresponding calibration results according to the experimental scheme;Then the measurement uncertainty of the indication error in the calibration results is evaluated by GUM, and the corresponding extended uncertainty </span><i><span style="font-family:Verdana;">U</span></i><sub><span style="font-family:Verdana;">95</span></sub><span style="font-family:Verdana;"> is obtained. Finally, according to the requirements of JJF1094-2016 characteristic evaluation of measuring instruments, combined with the calibration results and the actual situation of </span><i><span style="font-family:Verdana;">U</span></i><sub><span style="font-family:Verdana;">95</span></sub><span style="font-family:Verdana;">, the conformity of the indication error of calibration is determined. The result is that each calibration point of the sensor meets the requirements of conformity determination and is within the qualified range. This research effectively makes up for the blank of the previous research on the conformity determination of the indication error of the calibration results and has strong theoretical and practical significance.展开更多
The deviation control of directional drilling is essentially the controlling of two angles of the wellbore actually drilled, namely, the inclination and azimuth. In directional drilling the bit trajectory never coinci...The deviation control of directional drilling is essentially the controlling of two angles of the wellbore actually drilled, namely, the inclination and azimuth. In directional drilling the bit trajectory never coincides exactly with the planned path, which is usually a plane curve with straight, building, holding, and dropping sections in succession. The drilling direction is of course dependant on the direction of the resultant forces acting on the bit and it is quite a tough job to hit the optimum target at the hole bottom as required. The traditional passive methods for correcting the drilling path have not met the demand to improve the techniques of deviation control. A method for combining wellbore surveys to obtain a composite, more accurate well position relies on accepting the position of the well from the most accurate survey instrument used in a given section of the wellbore. The error in each position measurement is the sum of many independent root sources of error effects. The relationship between surveys and other influential factors is considered, along with an analysis of different points of view. The collaborative work describes, establishes a common starting point of wellbore position uncertainty model, definition of what constitutes an error model, mathematics of position uncertainty calculation and an error model for basic directional service.展开更多
文摘In order to solve the lack of relevant evaluation research on the accuracy of HMP155A humidity sensor calibration results in the past, this paper designs the corresponding experimental scheme, and obtains the corresponding calibration results according to the experimental scheme;Then the measurement uncertainty of the indication error in the calibration results is evaluated by GUM, and the corresponding extended uncertainty </span><i><span style="font-family:Verdana;">U</span></i><sub><span style="font-family:Verdana;">95</span></sub><span style="font-family:Verdana;"> is obtained. Finally, according to the requirements of JJF1094-2016 characteristic evaluation of measuring instruments, combined with the calibration results and the actual situation of </span><i><span style="font-family:Verdana;">U</span></i><sub><span style="font-family:Verdana;">95</span></sub><span style="font-family:Verdana;">, the conformity of the indication error of calibration is determined. The result is that each calibration point of the sensor meets the requirements of conformity determination and is within the qualified range. This research effectively makes up for the blank of the previous research on the conformity determination of the indication error of the calibration results and has strong theoretical and practical significance.
文摘The deviation control of directional drilling is essentially the controlling of two angles of the wellbore actually drilled, namely, the inclination and azimuth. In directional drilling the bit trajectory never coincides exactly with the planned path, which is usually a plane curve with straight, building, holding, and dropping sections in succession. The drilling direction is of course dependant on the direction of the resultant forces acting on the bit and it is quite a tough job to hit the optimum target at the hole bottom as required. The traditional passive methods for correcting the drilling path have not met the demand to improve the techniques of deviation control. A method for combining wellbore surveys to obtain a composite, more accurate well position relies on accepting the position of the well from the most accurate survey instrument used in a given section of the wellbore. The error in each position measurement is the sum of many independent root sources of error effects. The relationship between surveys and other influential factors is considered, along with an analysis of different points of view. The collaborative work describes, establishes a common starting point of wellbore position uncertainty model, definition of what constitutes an error model, mathematics of position uncertainty calculation and an error model for basic directional service.