期刊文献+
共找到4,353篇文章
< 1 2 218 >
每页显示 20 50 100
Phase-Based Optical Flow Method with Optimized Parameter Settings for Enhancing Displacement Measurement Adaptability
1
作者 Zhaoxin Peng Menglian Liu +2 位作者 Zhiliang Wang Wei Liu Xian Wang 《Open Journal of Applied Sciences》 2024年第5期1165-1184,共20页
To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizi... To enhance the applicability and measurement accuracy of phase-based optical flow method using complex steerable pyramids in structural displacement measurement engineering applications, an improved method of optimizing parameter settings is proposed. The optimized parameters include the best measurement points of the Region of Interest (ROI) and the levels of pyramid filters. Additionally, to address the issue of updating reference frames in practical applications due to the difficulty in estimating the maximum effective measurement value, a mechanism for dynamically updating reference frames is introduced. Experimental results demonstrate that compared to representative image gradient-based displacement measurement methods, the proposed method exhibits higher measurement accuracy in engineering applications. This provides reliable data support for structural damage identification research based on vibration signals and is expected to broaden the engineering application prospects for structural health monitoring. 展开更多
关键词 Displacement measurement Phase-Based Optical Flow Optimized parameter Setting
下载PDF
Drilling-based measuring method for the c-φ parameter of rock and its field application 被引量:3
2
作者 Bei Jiang Fenglin Ma +5 位作者 Qi Wang Hongke Gao Dahu Zhai Yusong Deng Chuanjie Xu Liangdi Yao 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第1期65-76,共12页
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R... The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters. 展开更多
关键词 Digital drilling Rock crushing zone c-u parameter measurement method Field application
下载PDF
Digital measuring the ocular morphological parameters of guinea pig eye in vivo with Python
3
作者 Yue Di Zhong-Bao Qiao +4 位作者 Hai-Yun Ye Xin-Yue Li Wen-Ting Luo Wang-Yi Fang Tong Qiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期239-246,共8页
AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtai... AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtain the horizontal,coronal,and sagittal planes respectively.The corresponding photo pixels-actual length ratio was acquired by a proportional scale.The edge coordinates were identified artificially by ginput function.Circle and conic curve fitting were applied to fit the contour of the eyeball in the sagittal,coronal and horizontal view.The curvature,curvature radius,eccentricity,tilt angle,corneal diameter,and binocular separation angle were calculated according to the geometric principles.Next,the eyeballs were removed,canny edge detection was applied to identify the contour of eyeball in vitro.The results were compared between in vivo and in vitro.RESULTS:Regarding the corneal curvature and curvature radius on the horizontal and sagittal planes,no significant differences were observed among results in vivo,in vitro,and the keratometer.The horizontal and vertical binocular separation angles were 130.6°±6.39°and 129.8°±9.58°respectively.For the corneal curvature radius and eccentricity in vivo,significant differences were observed between horizontal and vertical planes.CONCLUSION:The Graphical interface window of Python makes up the deficiency of edge detection,which requires too much definition in Matlab.There are significant differences between guinea pig and human beings,such as exotropic eye position,oblique oval eyeball,and obvious discrepancy of binoculus.This study helps evaluate objectively the ocular morphological parameters of small experimental animals in emmetropization research. 展开更多
关键词 ocular morphological parameters guinea pig digital measurement PYTHON
下载PDF
Algorithms for automatic measurement of SIS-type hysteretic underdamped Josephson junction’s parameters by current-voltage characteristics
4
作者 Aleksey G.Vostretsov Svetlana G.Filatova 《Journal of Electronic Science and Technology》 EI CSCD 2023年第4期60-74,共15页
Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic nois... Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic noise level of measuring instruments.This leads to the need for multiple measurements with subsequent statistical processing.In this paper,the digital algorithms are proposed for the automatic measurement of the JJ parameters by IVC.These algorithms make it possible to implement multiple measurements and check these JJ parameters in an automatic mode with the required accuracy.The complete sufficient statistics are used to minimize the root-mean-square error of parameter measurement.A sequence of current pulses with slow rising and falling edges is used to drive JJ,and synchronous current and voltage readings at JJ are used to realize measurement algorithms.The algorithm performance is estimated through computer simulations.The significant advantage of the proposed algorithms is the independence from current source noise and intrinsic noise of current and voltage meters,as well as the simple implementation in automatic digital measuring systems.The proposed algorithms can be used to control JJ parameters during mass production of superconducting integrated circuits,which will improve the production efficiency and product quality. 展开更多
关键词 Algorithm design and analysis Critical current Current-voltage characteristics(IVCs) Josephson junction(JJ) measurement errors parameter estimation
下载PDF
Flow measurement and parameter optimization of right-angled flow passage in hydraulic manifold block 被引量:7
5
作者 HU Jian-jun CHEN Jin +1 位作者 QUAN Ling-xiao KONG Xiang-dong 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第4期852-864,共13页
This study was conducted to investigate the flow field characteristics of right-angled flow passage with various cavities in the typical hydraulic manifold block.A low-speed visualization test rig was developed and th... This study was conducted to investigate the flow field characteristics of right-angled flow passage with various cavities in the typical hydraulic manifold block.A low-speed visualization test rig was developed and the flow field of the right-angled flow passage with different cavity structures was measured using 2D-PIV technique.Numerical model was established to simulate the three-dimensional flow field.Seven eddy viscosity turbulence models were investigated in predicting the flow field by comparing against the particle image relocimetry(PIV)measurement results.By defining the weight error function K,the S-A model was selected as the appropriate turbulence model.Then,a three-factor,three-level response surface numerical test was conducted to investigate the influence of flow passage connection type,cavity diameter and cavity length-diameter ratio on pressure loss.The results show that the Box-Benhnken Design(BBD)model can predict the total pressure loss accurately.The optimal factor level appeared in flow passage connection type II,14.64 mm diameter and 67.53%cavity length-diameter ratio.The total pressure loss decreased by 11.15%relative to the worst factor level,and total pressure loss can be reduced by 64.75%when using an arc transition right-angled flow passage,which indicates a new direction for the optimization design of flow passage in hydraulic manifold blocks. 展开更多
关键词 flow measurement particle image relocimetry right-angled flow passage parameter optimization
下载PDF
Application of Uniform Experimental Design in Optimizing Excitation Parameters for Magnetic Frequency Mixing Measurements 被引量:2
6
作者 Yu Chang Jingpin Jiao +3 位作者 Xiucheng Liu Guanghai Li Cunfu He Bin Wu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2020年第1期197-209,共13页
Excitation parameter preferences are key factors a ecting the performance of magnetic frequency mixing detection.A uniform experimental design method was used to analyze this influence.Using fuzzy theory,a comprehensi... Excitation parameter preferences are key factors a ecting the performance of magnetic frequency mixing detection.A uniform experimental design method was used to analyze this influence.Using fuzzy theory,a comprehensive model is established for evaluating the e ect of magnetic frequency mixing.A polynomial is selected as the regression function to express explicitly the correlation between the excitation parameters and the frequency-mixing e ect.The excitation parameters were then optimized using genetic algorithm.Magnetic frequency mixing experiments were conducted to measure the surface hardness of some ferromagnetic materials.Frequency mixing is further enhanced under the optimal settings,resulting in an improvement in the measurement sensitivity.The results of this study support the application of the magnetic frequency mixing technique in non-destructive testing. 展开更多
关键词 MAGNETIC frequency MIXING technology EXCITATION parameters UNIFORM experimental design Regression STATISTICAL method Surface HARDNESS measurement
下载PDF
The electrical parameters measurement system for electrotome output based on Labview 被引量:3
7
作者 Shengjie Yan Yu Zhou +3 位作者 Bowen Yan Dianli Li Chengli Song Zhaohua Chang 《Journal of Biomedical Science and Engineering》 2013年第6期661-668,共8页
An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system... An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system based on personal computer (PC) is developed hereby. It senses voltage and current in isolation from generators with transformers, and then the measured values are amplified, filtered, transformed into single-ended signals and converted to RMS. The detected signals are transformed into digital signals through Data Acquisition Card (DAQ) and the data are processed with quadratic fit in Labview. Finally, the controller completes constant power output. The experiment results indicate that the energy detection system can measure the output parameters precisely and the controller can achieve constant power control. 展开更多
关键词 : Energy GENERATOR HIGH-FREQUENCY Electrical parameterS measurement CONSTANT Power
下载PDF
STRUCTURAL PARAMETERS CALIBRATION BY POSTURE MEASUREMENT ON PARALLEL 6-DOF PLATFORM 被引量:1
8
作者 Wu Jiangning Li ShilunState Key Laboratory of Fluid Power Transmission and Control, Zhejiang University,Hangzhou 310027, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第4期334-338,343,共6页
Some approaches to measure parallel 6-degree of freedom platform's posturestatically and to calibrate the platform's actual structural parameters by measuring a series of theplatform's varying postures are... Some approaches to measure parallel 6-degree of freedom platform's posturestatically and to calibrate the platform's actual structural parameters by measuring a series of theplatform's varying postures are studied. In the case where high posture accuracy is requiredrelatively, to obtain the platform's actual structural parameters is very important. Threedimensions measurement with 2 theodolites are used to obtain the platform's postures statically andNewton iterative method is adopted to calibrate structural parameters. Some measures taken in themeasurement and the calibration are discussed in detail. And the experiment results of theplatform's posture control before and after the calibration are given. The results show that theplatform's posture control accuracy after the calibration is improved notably. 展开更多
关键词 parallel 6-DOF platform theodolite posture measurement nonlinearequation group structural parameters calibration
下载PDF
Intelligent Antenna Attitude Parameters Measurement Based on Deep Learning SSD Model 被引量:2
9
作者 FAN Guotian WANG Zhibin 《ZTE Communications》 2022年第S01期36-43,共8页
Due to the consideration of safety,non-contact measurement methods are be-coming more acceptable.However,massive measurement will bring high labor-cost and low working efficiency.To address these limitations,this pape... Due to the consideration of safety,non-contact measurement methods are be-coming more acceptable.However,massive measurement will bring high labor-cost and low working efficiency.To address these limitations,this paper introduces a deep learning model for the antenna attitude parameter measurement,which can be divided into an an-tenna location phase and a calculation phase of the attitude parameter.In the first phase,a single shot multibox detector(SSD)is applied to automatically recognize and discover the antenna from pictures taken by drones.In the second phase,the located antennas’fea-ture lines are extracted and their attitude parameters are then calculated mathematically.Experiments show that the proposed algorithms outperform existing related works in effi-ciency and accuracy,and therefore can be effectively used in engineering applications. 展开更多
关键词 deep learning DRONE object detection SSD algorithm visual measurement antenna attitude parameters
下载PDF
INVESTIGATION OF PULSED-WIRE TECHNIQUE FOR WALL PARAMETERS MEASUREMENT IN SEPARATED FLOWS
10
作者 Liao Yufeng, Xu Cheng(Mechanical Engineering Institute, Nanjing University of Scienceand Technology, Nanjing, 210094, China) 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 1997年第2期98-103,共6页
A pulsed-wire wall probe measurement system was developed in this paper,which can be used for measuring wall Parameters in separated flow- The operating princi-ple was described and the way of probe calibration was gi... A pulsed-wire wall probe measurement system was developed in this paper,which can be used for measuring wall Parameters in separated flow- The operating princi-ple was described and the way of probe calibration was given. Wall parameters of back-ward-facing and forward-facing step flow were measured,and the wall nows structure andcharacters were revealed. 展开更多
关键词 separated flow measurement pulse heating wall parameters pulsed-wire wall probe
下载PDF
Quantum parameter estimation in a spin-boson dephasing quantum system by periodical projective measurements
11
作者 Le Yang Hong-Yi Dai Ming Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第4期242-249,共8页
In this paper,we explore how to estimate the phase damping parameter γ and the tunneling amplitude parameter ?from a spin-boson dephasing quantum model by periodical projective measurements.The preparation of initia... In this paper,we explore how to estimate the phase damping parameter γ and the tunneling amplitude parameter ?from a spin-boson dephasing quantum model by periodical projective measurements.The preparation of initial states is accomplished by performing the period measurements in our scheme.The parameter γ can be always estimated when projective measurement bases are chosen as θ = π/2 and φ = 0.Based on the estimated value of γ and the interval information of ?,we can select another measurement bases(θ = π/4 and φ = π/2) to obtain the estimated value of ?.A coherent control is indispensable to estimate ? if γ is in the interval of ?;whereas the control is not necessary if γ is out of the known interval of ?.We establish the relation between the optimal period time and the parameter γ or ? in terms of Fisher information.Although the optimal measurement period cannot be selected beforehand,the aforementioned relation can be utilized to adjust the measurement period to approach the optimal one. 展开更多
关键词 parameter estimation periodical projective measurement spin-boson model dephasing quantum system
下载PDF
Robust H-infinity filtering for time-delaysystems with missing measurements:a parameter-dependent approach
12
作者 Xiao HE Donghua ZHOU 《控制理论与应用(英文版)》 EI 2007年第4期336-344,共9页
Robust H-infinity filtering for a class of uncertain discrete-time linear systems with time delays and missing measurements is studied in this paper. The uncertain parameters are supposed to reside in a convex polytop... Robust H-infinity filtering for a class of uncertain discrete-time linear systems with time delays and missing measurements is studied in this paper. The uncertain parameters are supposed to reside in a convex polytope and the missing measurements are described by a binary switching sequence satisfying a Bernoulli distribution. Our attention is focused on the analysis and design of robust H-infinity filters such that, for all admissible parameter uncertainties and all possible missing measurements, the filtering error system is exponentially mean-square stable with a prescribed H-infinity disturbance attenuation level. A parameter-dependent approach is proposed to derive a less conservative result. Sufficient conditions are established for the existence of the desired filter in terms of certain linear matrix inequalities (LMIs). When these LMIs are feasible, an explicit expression of the desired filter is also provided. Finally, a numerical example is presented to illustrate the effectiveness and applicability of the proposed method. 展开更多
关键词 Robust H-infinity filtering Polytopic uncertainties Missing measurements TIME-DELAYS parameter de-pendent Linear matrix inequalities (LMIs)
下载PDF
Parameter Measurement of 4010 Synthetic Aviation Lubricant
13
作者 刘志全 葛培琪 +1 位作者 齐毓霖 张鹏顺 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1997年第1期77-81,共5页
ParameterMeasurementof4010SyntheticAviationLubricantLIUZhiquanGEPeiqiQIYulinZHANGPengshun刘志全,葛培琪,齐毓霖,张鹏顺(Dep... ParameterMeasurementof4010SyntheticAviationLubricantLIUZhiquanGEPeiqiQIYulinZHANGPengshun刘志全,葛培琪,齐毓霖,张鹏顺(Dept.ofMechanicalEng... 展开更多
关键词 刘志 SYNTHETIC 张鹏 measurement parameter AVIATION LUBRICANT
下载PDF
Accurate vision measurement for kinematic parameters of satellite separation tests
14
作者 胡星志 朱肇昆 陈小前 《Journal of Central South University》 SCIE EI CAS 2013年第7期1825-1831,共7页
The accurate measurement of kinematic parameters in satellite separation tests has great significance in evaluating separation performance. A novel study is made on the measuring accuracy of monocular and binocular, w... The accurate measurement of kinematic parameters in satellite separation tests has great significance in evaluating separation performance. A novel study is made on the measuring accuracy of monocular and binocular, which are the two main vision measurement methods used for kinematic parameters. As satellite separation process is transient and high-dynamic, it will bring more extraction errors to the binocular. Based on the design approach of intersection measure and variance ratio, the monocular method reflects higher precision, simpler structure and easier calibration for level satellite separation. In ground separation tests, a high-speed monocular system is developed to gain and analyze twelve kinematic parameters of a small satellite. Research shows that this monocular method can be widely applied for its high precision, with position accuracy of 0.5 mm, speed accuracy of 5 mm/s, and angular velocity accuracy of 1 (°)/s. 展开更多
关键词 satellite separation vision measurement kinematic parameter monocular vision binocular vision extraction error
下载PDF
Intraretinal layer segmentation and parameter measurement in optic nerve head region through energy function of spatial-gradient continuity constraint
15
作者 CHEN Zai-liang WEI Hao +4 位作者 SHEN Hai-lan PENG Peng YUE Ke-juan LI Jian-feng ZOU Bei-ji 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第8期1938-1947,共10页
For the diagnosis of glaucoma,optical coherence tomography(OCT)is a noninvasive imaging technique for the assessment of retinal layers.To accurately segment intraretinal layers in an optic nerve head(ONH)region,we pro... For the diagnosis of glaucoma,optical coherence tomography(OCT)is a noninvasive imaging technique for the assessment of retinal layers.To accurately segment intraretinal layers in an optic nerve head(ONH)region,we proposed an automatic method for the segmentation of three intraretinal layers in eye OCT scans centered on ONH.The internal limiting membrane,inner segment and outer segment,Bruch’s membrane surfaces under vascular shadows,and interaction of multiple high-reflectivity regions in the OCT image can be accurately segmented through this method.Then,we constructed a novel spatial-gradient continuity constraint,termed spatial-gradient continuity constraint,for the correction of discontinuity between adjacent image segmentation results.In our experiment,we randomly selected 20 B-scans,each annotated three retinal layers by experts.Signed distance errors of?0.80μm obtained through this method are lower than those obtained through the state-of-art method(?1.43μm).Meanwhile,the segmentation results can be used as bases for the diagnosis of glaucoma. 展开更多
关键词 surface segmentation parameter measurement optical coherence tomography optic nerve head spatial-gradient continuity constraints
下载PDF
Modified robust finite-horizon filter for discrete-time systems with parameter uncertainties and missing measurements
16
作者 丰璐 邓志红 +1 位作者 王博 汪顺亭 《Journal of Beijing Institute of Technology》 EI CAS 2016年第1期108-114,共7页
A robust finite-horizon Kalman filter is designed for linear discrete-time systems subject to norm-bounded uncertainties in the modeling parameters and missing measurements.The missing measurements were described by a... A robust finite-horizon Kalman filter is designed for linear discrete-time systems subject to norm-bounded uncertainties in the modeling parameters and missing measurements.The missing measurements were described by a binary switching sequence satisfying a conditional probability distribution,the commonest cases in engineering,such that the expectation of the measurements could be utilized during the iteration process.To consider the uncertainties in the system model,an upperbound for the estimation error covariance was obtained since its real value was unaccessible.Our filter scheme is on the basis of minimizing the obtained upper bound where we refer to the deduction of a classic Kalman filter thus calculation of the derivatives are avoided.Simulations are presented to illustrate the effectiveness of the proposed approach. 展开更多
关键词 Kalman filter missing measurements parameter uncertainty robust filter upper bound
下载PDF
Schottky Barrier Parameters of Pd/Ti Contacts on N-Type InP Revealed from I-V-T And C-V-T Measurements
17
作者 D. Subba Reddy M. Bhaskar Reddy +1 位作者 N. Nanda Kumar Reddy V. Rajagopal Reddy 《Journal of Modern Physics》 2011年第3期113-123,共11页
We report on the current-voltage (I-V) and capacitance-voltage (C-V) characteristics of the Pd/Ti/n-InP Schottky barrier diodes (SBDs) in the temperature range 160-400 K in steps of 40 K. The barrier heights and ideal... We report on the current-voltage (I-V) and capacitance-voltage (C-V) characteristics of the Pd/Ti/n-InP Schottky barrier diodes (SBDs) in the temperature range 160-400 K in steps of 40 K. The barrier heights and ideality factors of Schottky contact are found in the range 0.35 eV (I-V), 0.73 eV (C-V) at 160 K and 0.63 eV (I-V), 0.61 eV (C-V) at 400 K, respectively. It is observed that the zero-bias barrier height decreases and ideality factor n increase with a decrease in temperature, this behaviour is attributed to barrier inhomogeneities by assuming Gaussian distribution at the interface. The calculated value of series resistance (Rs) from the forward I-V characteristics is decreased with an increase in temperature. The homogeneous barrier height value of approximately 0.71 eV for the Pd/Ti Schottky diode has been obtained from the linear relationship between the temperature-dependent experimentally effective barrier heights and ideality factors. The zero-bias barrier height ( ) versus 1/2kT plot has been drawn to obtain evidence of a Gaussian distribution of the barrier heights and values of = 0.80 eV and = 114 mV for the mean barrier height and standard deviation have been obtained from the plot, respectively. The modified Richardson ln(I0/T2)- ( ) versus 1000/T plot has a good linearity over the investigated temperature range and gives the mean barrier height ( ) and Richardson constant (A*) values as 0.796 eV and 6.16 Acm-2K-2 respectively. The discrepancy between Schottky barrier heights obtained from I-V and C-V measurements is also interpreted. 展开更多
关键词 SCHOTTKY Barrier parameters I-V-T and C-V-T measurementS Pd/Ti SCHOTTKY CONTACTS N-Type InP Gaussian Distribution
下载PDF
Study on Noninvasive Temperature Measurement in Biological Media Using Ultrasonic Nonlinear Parameter B/A
18
作者 WU Shui-cai, XIA Ya-qin, BAI Yan-ping , NAN Qun, PENG Jian-shu 《Chinese Journal of Biomedical Engineering(English Edition)》 2002年第3期119-124,共6页
Application of the temperature dependence of ultrasound nonlinear parameter B/A can realize noninvasive temperature measurement in biological media. The principle of temperature measurement is described and an experim... Application of the temperature dependence of ultrasound nonlinear parameter B/A can realize noninvasive temperature measurement in biological media. The principle of temperature measurement is described and an experiment system is set up. The experiments for measuring the nonlinear parameter B/A and estimating their temperature dependences in tested media are described. Preliminary experiment results are presented. 展开更多
关键词 ULTRASOUND Nonlinear parameter B/A TEMPERATURE measurement.
下载PDF
COMPUTER-AIDED OPTIMUM SOLUTION FOR SCATTERING PARAMETER MEASUREMENTS OF TWO-PORT LOSSLESS NETWORK
19
作者 粱昌洪 邱长兴 《Journal of Electronics(China)》 1990年第1期15-21,共7页
A new constrained eigenvalue method for scattering parameter measurements oftwo-port lossless reciprocal network is developed.The non-linear S-curve problem is easily trans-formed into a simple linear one by this meth... A new constrained eigenvalue method for scattering parameter measurements oftwo-port lossless reciprocal network is developed.The non-linear S-curve problem is easily trans-formed into a simple linear one by this method.All formulas are programmed on the IBM-PCdigital computer.Some examples are given. 展开更多
关键词 S-parameterS MICROWAVE measurement CAM
下载PDF
Numerical simulation and parameter optimization of Coriolis force scale measurement process based on DEM
20
作者 Haiting Liu Yong Yang +2 位作者 Xiangliang Wang Jiewen Deng Bingbing Wang 《Particuology》 SCIE EI CAS CSCD 2024年第7期128-139,共12页
The Coriolis force method is a recently developed and highly regarded direct measurement technique that enables high-precision measurement of bulk materials.The operational parameters and variations thereof directly i... The Coriolis force method is a recently developed and highly regarded direct measurement technique that enables high-precision measurement of bulk materials.The operational parameters and variations thereof directly influence the measurement accuracy of the equipment.In this study,a measurement correction coefficient is introduced to improve the calculation method for mass flow rate of the materials.The DEM is employed to simulate the motion of particle groups within the Coriolis force scale under different parameters,and the effects of various structural and operational parameters on the measurement results are compared.The research findings indicate that a lower rotational speed leads to more stable instantaneous measurement results,although the measurement error is relatively large.When the rotational speed exceeds 300 rpm,the measurement error remains within 15%.For materials with a radius of 1–2 mm,the variation range of precision error is approximately 0.4%.Among the structural parameters,the radius of the measurement wheel has the most significant impact on the measurement results,wherein a larger measurement wheel radius corresponds to a smaller measurement error.The horizontal angle of the blades follows as the next influential parameter,with a clockwise rotation and a horizontal angle of 30°resulting in a measurement error below 2%. 展开更多
关键词 parameter optimization Discrete element method Coriolis force scale measurement error Numerical simulation
原文传递
上一页 1 2 218 下一页 到第
使用帮助 返回顶部