A comparison of the temperature dependence of the P-hit single event transient (SET) in a two-transistor (2T) inverter with that in a three-transistor (3T) inverter is carried out based on a three-dimensional nu...A comparison of the temperature dependence of the P-hit single event transient (SET) in a two-transistor (2T) inverter with that in a three-transistor (3T) inverter is carried out based on a three-dimensional numerical simulation. Due to the significantly distinct mechanisms of the single event change collection in the 2T and the 3T inverters, the temperature plays different roles in the SET production and propagation. The SET pulse will be significantly broadened in the 2T inverter chain while will be compressed in the 3T inverter chain as temperature increases. The investigation provides a new insight into the SET mitigation under the extreme environment, where both the high temperature and the single event effects should be considered. The 3T inverter layout structure (or similar layout structures) will be a better solution for spaceborne integrated circuit design for extreme environments.展开更多
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufac...The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure, performance test and results of the quadrant silicon detector developed recently at the China Institute of Atomic Energy are presented. The detector is about 300 μm thick with a 48 mm×48 mm active area.The leakage current under the full depletion bias voltage of-16 V is about 2.5 n A, and the rise time is better than160 ns. The energy resolution for a 5.157 Me V α-particle is around the level of 1%. Charge sharing effects between the neighboring quads, leading to complicated correlations between two quads, were observed when α particles illuminated on the junction side. It is explained as a result of distortion of the electric field of the inter-quad region.Such an event is only about 0.6% of all events and can be neglected in an actual application.展开更多
The performance of a double sided silicon strip detector (DSSSD), which is used for the position and energy detection of heavy ions, is reported. The analysis shows that although the incomplete charge collection (...The performance of a double sided silicon strip detector (DSSSD), which is used for the position and energy detection of heavy ions, is reported. The analysis shows that although the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD give rise to a loss of energy resolution, the position information is recorded without ambiguity. Representations of ICC/CS events in the energy spectra are shown and their origins are confirmed by correlation analysis of the spectra from both the junction side and ohmic side of the DSSSD.展开更多
基金Project supported by the Key Program of the National Natural Science Foundation of China(Grant No.60836004)
文摘A comparison of the temperature dependence of the P-hit single event transient (SET) in a two-transistor (2T) inverter with that in a three-transistor (3T) inverter is carried out based on a three-dimensional numerical simulation. Due to the significantly distinct mechanisms of the single event change collection in the 2T and the 3T inverters, the temperature plays different roles in the SET production and propagation. The SET pulse will be significantly broadened in the 2T inverter chain while will be compressed in the 3T inverter chain as temperature increases. The investigation provides a new insight into the SET mitigation under the extreme environment, where both the high temperature and the single event effects should be considered. The 3T inverter layout structure (or similar layout structures) will be a better solution for spaceborne integrated circuit design for extreme environments.
基金Supported by National Basic Research Program of China(2013CB834404)National Natural Science Foundation of China(10727505,10735100,11375268)
文摘The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure, performance test and results of the quadrant silicon detector developed recently at the China Institute of Atomic Energy are presented. The detector is about 300 μm thick with a 48 mm×48 mm active area.The leakage current under the full depletion bias voltage of-16 V is about 2.5 n A, and the rise time is better than160 ns. The energy resolution for a 5.157 Me V α-particle is around the level of 1%. Charge sharing effects between the neighboring quads, leading to complicated correlations between two quads, were observed when α particles illuminated on the junction side. It is explained as a result of distortion of the electric field of the inter-quad region.Such an event is only about 0.6% of all events and can be neglected in an actual application.
基金Supported by National Natural Science Foundation of China(10905076,11005127,11075190,11205209,11205221)National Basic Research Program of China(973 Program)(2014CB845405)
文摘The performance of a double sided silicon strip detector (DSSSD), which is used for the position and energy detection of heavy ions, is reported. The analysis shows that although the incomplete charge collection (ICC) and charge sharing (CS) effects of the DSSSD give rise to a loss of energy resolution, the position information is recorded without ambiguity. Representations of ICC/CS events in the energy spectra are shown and their origins are confirmed by correlation analysis of the spectra from both the junction side and ohmic side of the DSSSD.