期刊文献+
共找到17,073篇文章
< 1 2 250 >
每页显示 20 50 100
Fault Identification for Shear-Type Structures Using Low-Frequency Vibration Modes
1
作者 Cuihong Li Qiuwei Yang Xi Peng 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2769-2791,共23页
Shear-type structures are common structural forms in industrial and civil buildings,such as concrete and steel frame structures.Fault diagnosis of shear-type structures is an important topic to ensure the normal use o... Shear-type structures are common structural forms in industrial and civil buildings,such as concrete and steel frame structures.Fault diagnosis of shear-type structures is an important topic to ensure the normal use of structures.The main drawback of existing damage assessment methods is that they require accurate structural finite element models for damage assessment.However,for many shear-type structures,it is difficult to obtain accurate FEM.In order to avoid finite elementmodeling,amodel-freemethod for diagnosing shear structure defects is developed in this paper.This method only needs to measure a few low-order vibration modes of the structure.The proposed defect diagnosis method is divided into two stages.In the first stage,the location of defects in the structure is determined based on the difference between the virtual displacements derived from the dynamic flexibility matrices before and after damage.In the second stage,damage severity is evaluated based on an improved frequency sensitivity equation.Themain innovations of this method lie in two aspects.The first innovation is the development of a virtual displacement difference method for determining the location of damage in the shear structure.The second is to improve the existing frequency sensitivity equation to calculate the damage degree without constructing the finite elementmodel.Thismethod has been verified on a numerical example of a 22-story shear frame structure and an experimental example of a three-story steel shear structure.Based on numerical analysis and experimental data validation,it is shown that this method only needs to use the low-order modes of structural vibration to diagnose the defect location and damage degree,and does not require finite element modeling.The proposed method should be a very simple and practical defect diagnosis technique in engineering practice. 展开更多
关键词 Fault diagnosis shear steel structure vibration mode dynamic flexibility frequency sensitivity
下载PDF
AN EFFICIENT ASSESSMENT METHOD FOR INTELLIGENT DESIGN RESULTS OF SHEAR WALL STRUCTURE BASED ON MECHANICAL PERFORMANCE,MATERIAL CONSUMPTION,AND EMPIRICAL RULES
2
作者 覃思中 廖文杰 +1 位作者 林元庆 陆新征 《工程力学》 EI CSCD 北大核心 2023年第12期148-159,共12页
Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This... Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This study introduces an assessment method used in the intelligent design and optimization of shear wall structures that effectively combines mechanical analysis and formulaic encoding of empirical rules.First,the critical information about the structure was extracted through data structuring.Second,an empirical rule assessment method was developed based on the engineer's experience and design standards to complete a preliminary assessment and screening of the structure.Subsequently,an assessment method based on mechanical performance and material consumption was used to compare different structural schemes comprehensively.Finally,the assessment effectiveness was demonstrated using a typical case.Compared to traditional assessment methods,the proposed method is more comprehensive and significantly more efficient,promoting the intelligent transformation of structural design. 展开更多
关键词 shear wall structure structural assessment data structuring intelligent design structural optimization
下载PDF
Seismic performance evaluation of hybrid coupled shear wall system with shear and flexural fuse-type steel coupling beams
3
作者 Zahra Ramezandoust Abbas Tajaddini Panam Zarfam 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第3期691-712,共22页
Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically... Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically evaluate the seismic behavior of flexural and shear fuse beams situated in short-,medium-and high-rise RC buildings that have HCSWs.Three building groups hypothetically located in a high seismic hazard zone were studied.A series of 2D nonlinear time history analyses was accomplished in OpenSees,using the ground motion records scaled at the design basis earthquake level.It was found that the effectiveness of fuses in HCSWs depends on various factors such as size and scale of the building,allowable rotation value,inter-story drift ratio,residual drift quantity,energy dissipation value of the fuses,etc.The results show that shear fuses better meet the requirements of rotations and drifts.In contrast,flexural fuses dissipate more energy,but their sectional stiffness should increase to meet other requirements.It was concluded that adoption of proper fuses depends on the overall scale of the building and on how associated factors are considered. 展开更多
关键词 hybrid coupled shear wall steel fuse coupling beam shear and flexural fuse nonlinear dynamic analysis seismic performance
下载PDF
Experimental study of solid-liquid origami composite structures with improved impact resistance
4
作者 Shuheng Wang Zhanyu Wang +5 位作者 Bei Wang Zhi Liu Yunzhu Ni Wuxing Lai Shan Jiang Yong An Huang 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2024年第2期118-123,共6页
In this paper,a liquid-solid origami composite design is proposed for the improvement of impact resistance.Employing this design strategy,Kresling origami composite structures with different fillings were designed and... In this paper,a liquid-solid origami composite design is proposed for the improvement of impact resistance.Employing this design strategy,Kresling origami composite structures with different fillings were designed and fabricated,namely air,water,and shear thickening fluid(STF).Quasi-static compression and drop-weight impact experiments were carried out to compare and reveal the static and dynamic mechanical behavior of these structures.The results from drop-weight impact experiments demonstrated that the solid-liquid Kresling origami composite structures exhibited superior yield strength and reduced peak force when compared to their empty counterparts.Notably,the Kresling origami structures filled with STF exhibited significantly heightened yield strength and reduced peak force.For example,at an impact velocity of 3 m/s,the yield strength of single-layer STF-filled Kresling origami structures increased by 772.7%and the peak force decreased by 68.6%.This liquid-solid origami composite design holds the potential to advance the application of origami structures in critical areas such as aerospace,intelligent protection and other important fields.The demonstrated improvements in impact resistance underscore the practical viability of this approach in enhancing structural performance for a range of applications. 展开更多
关键词 Solid-liquid design Origami structure Impact resistance shear thickening fluid
下载PDF
Theory of Flexural Shear, Bending and Torsion for a Thin-Walled Beam of Open Section
5
作者 David W. A. Rees Abdelraouf M. Sami Alsheikh 《World Journal of Mechanics》 2024年第3期23-53,共31页
Aspects of the general Vlasov theory are examined separately as applied to a thin-walled channel section cantilever beam under free-end end loading. In particular, the flexural bending and shear that arise under trans... Aspects of the general Vlasov theory are examined separately as applied to a thin-walled channel section cantilever beam under free-end end loading. In particular, the flexural bending and shear that arise under transverse shear and axial torsional loading are each considered theoretically. These analyses involve the location of the shear centre at which transverse shear forces when applied do not produce torsion. This centre, when taken to be coincident with the centre of twist implies an equivalent reciprocal behaviour. That is, an axial torsion applied concentric with the shear centre will twist but not bend the beam. The respective bending and shear stress conversions are derived for each action applied to three aluminium alloy extruded channel sections mounted as cantilevers with a horizontal principal axis of symmetry. Bending and shear are considered more generally for other thin-walled sections when the transverse loading axes at the shear centre are not parallel to the section = s centroidal axes of principal second moments of area. The fixing at one end of the cantilever modifies the St Venant free angular twist and the free warping displacement. It is shown from the Wagner-Kappus torsion theory how the end constrained warping generates an axial stress distribution that varies with the length and across the cross-section for an axial torsion applied to the shear centre. It should be mentioned here for wider applications and validation of the Vlasov theory that attendant papers are to consider in detail bending and torsional loadings applied to other axes through each of the centroid and the web centre. Therein, both bending and twisting arise from transverse shear and axial torsion applied to each position being displaced from the shear centre. Here, the influence of the axis position upon the net axial and shear stress distributions is to be established. That is, the net axial stress from axial torsional loading is identified with the sum of axial stress due to bending and axial stress arising from constrained warping displacements at the fixing. The net shear stress distribution overlays the distributions from axial torsion and that from flexural shear under transverse loading. Both arise when transverse forces are displaced from the shear centre. 展开更多
关键词 Thin wall Theory Cantilever Beam Open Channel Section Principal Axes Flexure Transverse shear TORSION shear Centre shear Flow WARPING Fixed-End Constraint
下载PDF
Horizontal structure of convergent wind shear associated with sporadic E layers over East Asia
6
作者 LiHui Qiu Xian Lu +8 位作者 Tao Yu Yosuke Yamazaki HuiXin Liu Yang-Yi Sun HaoNan Wu XiaoMin Zuo XiangXiang Yan Yan Yu YiFan Qi 《Earth and Planetary Physics》 CAS CSCD 2023年第5期548-557,共10页
At present,the main detection instruments for observing sporadic E(Es)layers are ground-based radars,dense networks of ground-based global navigation satellite system(GNSS)receivers,and GNSS radio occultation,but they... At present,the main detection instruments for observing sporadic E(Es)layers are ground-based radars,dense networks of ground-based global navigation satellite system(GNSS)receivers,and GNSS radio occultation,but they cannot capture the whole picture of the horizontal structure of Es layers.This study employs the Whole Atmosphere Community Climate Model with thermosphere and ionosphere eXtension model(WACCM-X 2.1)to derive the horizontal structure of the ion convergence region(HSICR)to explore the shapes of the large-scale Es layers over East Asia for the period from June 1 to August 31,2008.The simulation produced the various shapes of the HSICRs elongated in the northwest-southeast,northeast-southwest,or composed of individual small patches.The close connection between Es layer critical frequency(foEs)and vertical ion convergence indicates that the HSICR is a good candidate for revealing and explaining the horizontal structure of the large-scale Es layers. 展开更多
关键词 sporadic E layer horizontal structure wind shear WACCM-X model
下载PDF
Nonlinear earthquake response analysis and energy calculation for seismic slit shear wall structures 被引量:6
7
作者 蒋欢军 吕西林 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2002年第2期227-236,共10页
Based on the concept of structural passive control,a new type of slit shear wall,with improved seismic performance when compared to an ordinary solid shear wall,was proposed by the authors in 1996.The idea has been ve... Based on the concept of structural passive control,a new type of slit shear wall,with improved seismic performance when compared to an ordinary solid shear wall,was proposed by the authors in 1996.The idea has been verified by a series of pseudo-static and dynamic tests.In this paper a macro numerical model is developed for the wall element and the energy dissipation device.Then,nonlinear time history analysis is carried out for a 10-story slit shear wall model tested on a shaking table.Furthermore,the seismic input energy and the individual energy dissipated by the components are calculated by a method based on Newmark-β assumptions for this shear wall model,and the advantages of this shear wall are further demonstrated by the calculation results from the viewpoint of energy.Finally,according to the seismic damage criterion on the basis of plastic accumulative energy and maximum response,the optimal analysis is carried out to select design parameters for the energy dissipation device. 展开更多
关键词 shear wall energy dissipation time history analysis optimal analysis seismic damage criterion
下载PDF
An elastic-plastic analysis of short-leg shear wall structures during earthquakes 被引量:2
8
作者 Ding Jianguo Zhu Ying 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第4期525-540,共16页
Short-leg shear wall structures are a new form of building structure that combine the merits of both frame and shear wall structures. Its architectural features, structure bearing and engineering cost are reasonable. ... Short-leg shear wall structures are a new form of building structure that combine the merits of both frame and shear wall structures. Its architectural features, structure bearing and engineering cost are reasonable. To analyze the elastic-plastic response of a short-leg shear wall structure during an earthquake, this study modified the multiple-vertical-rod element model of the shear wall, considered the shear lag effect and proposed a multiple-vertical-rod element coupling beam model with a new local stiffness domain. Based on the principle of minimum potential energy and the variational principle, the stiffness matrixes of a short-leg shear wall and a coupling beam are derived in this study. Furthermore, the bending shear correlation for the analysis of different parameters to describe the structure, such as the beam height to span ratio, short-leg shear wall height to thickness ratio, and steel ratio are introduced. The results show that the height to span ratio directly affects the structural integrity; and the short-leg shear wall height to thickness ratio should be limited to a range of approximately 6.0 to 7.0. The design of short-leg shear walls should be in accordance with the "strong wall and weak beam" principle. 展开更多
关键词 short-leg shear wall multiple-vertical-rod element model shear lag effect bending shear correlationcoefficient coupling beam stiffness matrix elastic-plastic analysis
下载PDF
Topology optimization of shear wall structures under seismic loading 被引量:2
9
作者 Pooya Zakian Ali Kaveh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期105-116,共12页
A topology optimization formulation is developed to find the stiffest structure with desirable material distribution subjected to seismic loads. Finite element models of the structures are generated and the optimality... A topology optimization formulation is developed to find the stiffest structure with desirable material distribution subjected to seismic loads. Finite element models of the structures are generated and the optimality criteria method is modified using a simple penalty approach and introducing fictitious strain energy to simultaneously consider both material volume and displacement constraints. Different types of shear walls with/without opening are investigated. Additionally, the effects of shear wall-frame interaction for single and coupled shear walls are studied. Gravity and seismic loads are applied to the shear walls so that the definitions provide a practical approach for locating the critical parts of these structures. The results suggest new viewpoints for architectural and structural engineering for placement of openings. 展开更多
关键词 topology optimization seismic loads shear wall minimum compliance multiple constraints fi nite element analysis
下载PDF
Cracking Patterns of Shear Walls in Reinforced Concrete Structure due to Strong Earthquake Based on Mohr-Coulomb Criterion 被引量:2
10
作者 查支祥 刘西拉 +1 位作者 彭卫 许波 《Journal of Donghua University(English Edition)》 EI CAS 2015年第4期541-548,共8页
A primary goal of seismic design of buildings is to protect people's life safety during strong earthquakes. Fundamentally,to predict the survived space and estimate people escape intervals during structural collap... A primary goal of seismic design of buildings is to protect people's life safety during strong earthquakes. Fundamentally,to predict the survived space and estimate people escape intervals during structural collapse are very important,which requires to describe the failure process more detailedly not only for structural joints but also for slabs and shear walls. In the present paper,the details of Mohr-Coulomb failure criterion with tension-cutoff together with its expression in failure surface and local coordinate system of reinforced concrete( RC) shear wall are given firstly,and then several typical cracking patterns of RC shear wall,such as tension shear crack and compression shear crack, are analyzed based on Mohr-Coulomb failure criterion with tension-cutoff. 展开更多
关键词 cracking patterns Mohr-Coulomb criterion shear wall
下载PDF
Shaking table experimental study of recycled concrete frame-shear wall structures 被引量:8
11
作者 Zhang Jianwei Cao Wanlin +2 位作者 Meng Shaobin Yu Cheng Dong Hongying 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第2期257-267,共11页
In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concea... In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concealed bracing detail. The four tested structures included one normal concrete model, one recycled coarse aggregate concrete model, and two recycled coarse and fi ne aggregate concrete models with or without concealed bracings inside the shear walls. The dynamic characteristics, dynamic response and failure mode of each model were compared and analyzed. Finite element models were also developed and nonlinear time-history response analysis was conducted. The test and analysis results show that the seismic performance of the recycled coarse aggregate concrete frame-shear wall structure is slightly worse than the normal concrete structure. The seismic resistance capacity of the recycled concrete frame-shear wall structure can be greatly improved by setting up concealed bracings inside the walls. With appropriate design, the recycled coarse aggregate concrete frame-shear wall structure and recycled concrete structure with concealed bracings inside the walls can be applied in buildings. 展开更多
关键词 recycled concrete frame-shear wall concealed bracings shaking table test nonlinear time-history response analysis
下载PDF
Seismic Analysis of Shear-Wall Structures with Vertically Installed Dampers
12
作者 Yang Jun Li Li Fan Aiwu 《Journal of China University of Geosciences》 SCIE CSCD 2005年第4期349-353,共5页
Shear-wall structures are quite common in seismic areas because of their successful seismic behavior during severe earthquakes. But shear walls are prone to brittle failure. This study proposes a new method of vertica... Shear-wall structures are quite common in seismic areas because of their successful seismic behavior during severe earthquakes. But shear walls are prone to brittle failure. This study proposes a new method of vertically installed dampers (VID) to reduce the vibration in shear-wall structures. The motion characteristic of a vertical damping system is that every mass has horizontal and rotational displacements simultaneously, The establishment of dynamic equations should take into account the equilibrium conditions of both horizontal and rotational vibrations. Dynamic equilibrium equations of VID systems are derived from a model of a structure with VID. An example shear-wall structure, with and with- out VID, is studied. There are some changes in the characteristics of the maximum horizontal displacement response. Without dampers, the relative displacements between different floors in the shear wall increase with height. With dampers, the relative displacements are more uniformly distributed, and lateral displacements at the top and at the bottom are closer. When the damping coefficient is 1 000 kN · s/ m, the numerical results reveal that the maximum horizontal displacement and the maximum rotational displacement of the top floor have reduced by 59.3 % and 54.8 % respectively. 展开更多
关键词 shear wall DAMPER dynamic equilibrium equation seismic response.
下载PDF
Cyclic testing of moment-shear force interaction in reinforced concrete shear wall substructures
13
作者 Ke Du Huan Luo Jingjiang Sun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第2期465-481,共17页
Previous quasi-static cyclic tests of shear walls,which routinely used an incremental lateral displacement test protocol with a constant axial load,failed to reflect the character of moment-shear force interaction of ... Previous quasi-static cyclic tests of shear walls,which routinely used an incremental lateral displacement test protocol with a constant axial load,failed to reflect the character of moment-shear force interaction of prototype buildings.To study the effect of the moment-shear force interaction on the seismic performance of shear walls,three identical 2-story shear wall specimens with different loading patterns were constructed at 1/2 scale,to represent the lower portion of an 11-story high-rise building,and were tested under reversed cyclic loads.The axial force,shear force and bending moment were simultaneously applied to simulate the effects of gravity loads and earthquake excitations on the prototype.The axial force and bending moment delivered from the upper structure were applied to the top of the specimens by two vertical actuators,and the shear force was applied to the specimens by two horizontal actuators.A mixed force-displacement control test program was adopted to ensure that the bending moment and the lateral shear were increased proportionally.The experimental results show that the moment-shear force interaction had a significant effect on the failure pattern,hysteretic characteristics,ductility and energy dissipation of the specimens.It is recommended that moment-shear force interaction should be considered in the loading condition of RC shear wall substructures cyclic tests. 展开更多
关键词 shear walls QUASI-STATIC cyclic TEST moment-shear force INTERACTION COLLAPSE TEST hysteretic curves forcedisplacement mixed control TEST
下载PDF
Improvement of Concrete Shear Wall Structures by Smart Materials
14
作者 Mehdi Ghassemieh Mohammad Reza Bahaari +1 位作者 Seyed Mohyeddin Ghodratian Seyed Ali Nojoumi 《Open Journal of Civil Engineering》 2012年第3期87-95,共9页
Smart materials have found numerous applications in many areas in civil engineering recently. One class of these materials is shape memory alloy (SMA) which exhibits several unique characteristics such as superelastic... Smart materials have found numerous applications in many areas in civil engineering recently. One class of these materials is shape memory alloy (SMA) which exhibits several unique characteristics such as superelasticity and shape memory effect. Due to these characteristics, research efforts have been extended to use SMA in controlling civil structures. This paper investigates the effectiveness of SMA reinforcements in enhancing the behavior of shear walls, especially when subjected to seismic excitations. Two ordinary and coupled shear walls were introduced as reference structures and were modeled by ABAQUS software. For improving the seismic response of the shear walls, vertical SMA reinforcing bars were proposed to be implemented like conventional steel reinforcements, throughout the height of the structures and in every connecting beam in the coupled shear wall system. The one dimensional superelastic model of SMA material was implemented in the computer software using FORTRAN code. The dynamic response of the shear walls subjected to seismic loading was investigated through time history analyses under El-centro and Koyna records. The results showed that using superelastic SMA material instead of steel bars caused remarkable reduction in residual displacement for both ordinary and coupled shear walls. In addition, SMA reinforcements could significantly decrease the maximum deflection of the coupled shear wall system. 展开更多
关键词 Smart Material SHAPE MEMORY Alloy shear wall SUPERELASTICITY SEISMIC Behavio
下载PDF
Analysis on Construction Quality Control Technology of Reinforced Concrete Shear Wall Structure
15
作者 Ting Zhou 《Frontiers Research of Architecture and Engineering》 2018年第4期117-121,共5页
In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa... In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises. 展开更多
关键词 REINFORCED CONCRETE shear wall structure Construction QUALITY Control technology
下载PDF
Effect of Molecular Weight and Molecular Distribution on Skin Structure and Shear Strength Distribution near the Surface of Thin-Wall Injection Molded Polypropylene
16
作者 Keisuke Maeda Koji Yamada +2 位作者 Kazushi Yamada Masaya Kotaki Hiroyuki Nishimura 《Open Journal of Organic Polymer Materials》 CAS 2016年第1期1-10,共10页
In this study, the relationship between skin structure and shear strength distribution of thin-wall injection molded polypropylene (PP) molded at different molecular weight and molecular distribution was investigated.... In this study, the relationship between skin structure and shear strength distribution of thin-wall injection molded polypropylene (PP) molded at different molecular weight and molecular distribution was investigated. Skin-core structure, cross-sectional morphology, crystallinity, crystal orientation, crystal morphology and molecular orientation were evaluated by using polarized optical microscope, differential scanning calorimeter, X-ray spectroscopic analyzer and laser Raman spectroscopy, respectively, while the shear strength distribution was investigated using a micro cutting method called SAICAS (Surface And Interfacial Cutting Analysis System). The results indicated that the difference of molecular weight and molecular weight distribution showed own skin layer thickness. Especially, high molecular weight sample showed thicker layer of the lamellar orientation and molecular orientation than low molecular weight sample. In addition, wide molecular distribution sample showed large crystal orientation layer. 展开更多
关键词 POLYPROPYLENE Thin-wall Injection Molding Molecular Weight and Molecular Weight Distribution Skin-Core structure shear Strength Distribution
下载PDF
Control of Progressive Collapse of the Structure Using Shear Wall
17
作者 Pruthviraj S R Shivukumarnaika M Prabhakara H R 《Journal of Smart Buildings and Construction Technology》 2022年第2期30-42,共13页
The vulnerability of reinforced concrete(RC)building systems to progres­sive collapse has turned out to be a challenging trouble for professional structural engineers so as to prevent total failure on account of ... The vulnerability of reinforced concrete(RC)building systems to progres­sive collapse has turned out to be a challenging trouble for professional structural engineers so as to prevent total failure on account of nearby dam­age.The goal of this paper is to enhance the knowledge of such buildings’behavior underneath several scenarios of misplaced columns at different floor stages,and their capacity for progressive collapse.The homes had been analyzed following the guidelines for progressive collapse evalua­tion and design organized by means of the general services administration guidelines(GSA).The progressive collapse of a ten story structure sub­jected to a simplest gravity load is taken into consideration and the column has been eliminated at one place and the spread damage is evaluated.The progressive collapse study has been carried out by way of removing the column at a diagnosed crucial locations(at corner,middle and at interi­or)as in line with GSA guidelines.Static analysis is done using analysis program ETABS.For each case,the consequences were taken in terms of demand capacity ratio(DCR)at critical section,and as a result the structure has been assessed for it’s susceptible to progressive collapse.The availabil­ity of shear wall is made on the component wherein collapse occurred and DCR values are mentioned.After imparting the shear wall to the structure,the progressive collapse of the structure because of accidental load may be controlled in order that the GSA guidelines recommended DCR value would be within the range. 展开更多
关键词 Progressive collapse analysis General Service Administration(GAS)Guidelines Demand capacity ratio(DCR) Column removal ETABS shear wall
下载PDF
Three dimensional shear wave velocity structure of crust and upper mantle in South China Sea and its adjacent regions by surface waveform inversion 被引量:22
18
作者 曹小林 朱介寿 +2 位作者 赵连锋 曹家敏 洪学海 《地震学报》 CSCD 北大核心 2001年第2期113-124,共12页
We assembled approximately 328 seismic records. The data set was from 4 digitally recording long-period and broadband stations of CDSN. We carried out the inversion based on the partitioned waveform inversion (PWI). I... We assembled approximately 328 seismic records. The data set was from 4 digitally recording long-period and broadband stations of CDSN. We carried out the inversion based on the partitioned waveform inversion (PWI). It partitions the large-scale optimization problem into a number of independent small-scale problems. We adopted surface waveform inversion with an equal block (2((2() discretization in order to acquire the images of shear velocity structure at different depths (from surface to 430 km) in the crust and upper-mantle. The resolution of all these anomalies has been established with (check-board( resolution tests. These results show significant difference in velocity, lithosphere and asthenosphere structure between South China Sea and its adjacent regions. 展开更多
关键词 面波波形 分块波形反演 三维S波速度结构 中国数字地震台网 “检验板”法 岩石圈
下载PDF
The Continuum Analytical Method of Steel Frame- Reinforced Concrete Shear Wall Mixed Structure
19
作者 Jian Liu Xiangyun Huang +2 位作者 Guangen Zhou Jiping Hao Zenglin Xing 《Journal of Civil Engineering and Architecture》 2011年第4期368-374,共7页
关键词 钢筋混凝土剪力墙 钢框架梁柱 混合结构 二阶效应 水平荷载 层间位移 接头连接 结构设计
下载PDF
Microstructure and shear strength of the brazed joint of Ti(C,N)-based cermet to steel 被引量:8
20
作者 YE Dameng, XIONG Weihao, Zhang Xiuhai, QU Jun, and YAO Zhenghua State Key Laboratory of Plastic Forming Simulation and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan 430074, China 《Rare Metals》 SCIE EI CAS CSCD 2010年第1期72-77,共6页
Firm joins were obtained between Ti(C,N)-based cermet and steel with Ag-Cu-Zn-Ni filler metal by vacuum brazing. The effects of technological parameters such as brazing temperature, holding time, and filler thicknes... Firm joins were obtained between Ti(C,N)-based cermet and steel with Ag-Cu-Zn-Ni filler metal by vacuum brazing. The effects of technological parameters such as brazing temperature, holding time, and filler thickness on the shear strength of the joints were investigated. The microstructure of welded area and the reaction products of the filler metal were examined by scanning electron microscopy (SEM), metallographic microscope (OM), energy-dispersive X-ray analysis (EDS), and X-ray diffraction (XRD). The brazing temperature of 870℃, holding time of 15 min, and filler thickness of 0.4 mm are a set of optimum technological parameters, under which the maximum shear strength of the joints, 176.5 MPa, is achieved. The results of microstructure show that the wettability of the filler metal on Ti(C,N)-based cermet and steel is well. A mutual solution layer and a diffusion layer exist between the welding base materials and the filler metal. 展开更多
关键词 Ti(C N)-based cermet vacuum brazing filler metal shear strength interface structure
下载PDF
上一页 1 2 250 下一页 到第