In the current study, streak camera was used to find concentricity of the assembly during detonation,investigate and compare shock front within the high explosive and behavior of the shock front on the surface of the ...In the current study, streak camera was used to find concentricity of the assembly during detonation,investigate and compare shock front within the high explosive and behavior of the shock front on the surface of the liner, one containing wave shaper and the other without wave shaper. Streaks revealed that the whole assembly was concentric till the formation of the jet. Observed streaks vindicate the uniform propagation of shock front in both the cases. Results obtained for shock front velocities are in agreement with those obtained from simulations. In the presence of wave shaper higher shock front velocity was observed both in simulation and experiment. Simulation without wave-shaper showed that shock front struck the copper cone at grazing angle while in the presence of wave-shaper it struck at an angle of 125.展开更多
A two-streak high-speed photography measuring system is designed, which can successfully record the reactive shock front and the reaction profile within the run distance of shock initiation under two-dimensional shock...A two-streak high-speed photography measuring system is designed, which can successfully record the reactive shock front and the reaction profile within the run distance of shock initiation under two-dimensional shock initiation. The strong reaction delay time and the shape of reaction shock front are determined in the cast composition B (RDX/TNT/60/40). A low level reaction zone has been found and analyzed..展开更多
Although the streaked optical pyrometer(SOP)system has been widely adopted in shock temperature measurements,its reliability has always been of concern.Here,two calibrated Planckian radiators with different color temp...Although the streaked optical pyrometer(SOP)system has been widely adopted in shock temperature measurements,its reliability has always been of concern.Here,two calibrated Planckian radiators with different color temperatures were used to calibrate and verify the SOP system by comparing the two calibration standards using both multi-channel and single-channel methods.A high-color-temperature standard lamp and a multi-channel filter were specifically designed for the measurement system.To verify the reliability of the SOP system,the relative deviation between the measured data and the standard value of less than 5%was calibrated out,which demonstrates the reliability of the SOP system.Furthermore,a method to analyze the uncertainty and sensitivity of the SOP system is proposed.A series of laserinduced shock experiments were conducted at the‘Shenguang-Ⅱ’laser facility to verify the reliability of the SOP system for temperature measurements at tens of thousands of kelvin.The measured temperature of the quartz in our experiments agreed fairly well with previous works,which serves as evidence for the reliability of the SOP system.展开更多
文摘In the current study, streak camera was used to find concentricity of the assembly during detonation,investigate and compare shock front within the high explosive and behavior of the shock front on the surface of the liner, one containing wave shaper and the other without wave shaper. Streaks revealed that the whole assembly was concentric till the formation of the jet. Observed streaks vindicate the uniform propagation of shock front in both the cases. Results obtained for shock front velocities are in agreement with those obtained from simulations. In the presence of wave shaper higher shock front velocity was observed both in simulation and experiment. Simulation without wave-shaper showed that shock front struck the copper cone at grazing angle while in the presence of wave-shaper it struck at an angle of 125.
文摘A two-streak high-speed photography measuring system is designed, which can successfully record the reactive shock front and the reaction profile within the run distance of shock initiation under two-dimensional shock initiation. The strong reaction delay time and the shape of reaction shock front are determined in the cast composition B (RDX/TNT/60/40). A low level reaction zone has been found and analyzed..
基金supported by the National Key R&D Program of China (No. 2017YFA0403200)the Science Challenge Project (No. TZ2016001)
文摘Although the streaked optical pyrometer(SOP)system has been widely adopted in shock temperature measurements,its reliability has always been of concern.Here,two calibrated Planckian radiators with different color temperatures were used to calibrate and verify the SOP system by comparing the two calibration standards using both multi-channel and single-channel methods.A high-color-temperature standard lamp and a multi-channel filter were specifically designed for the measurement system.To verify the reliability of the SOP system,the relative deviation between the measured data and the standard value of less than 5%was calibrated out,which demonstrates the reliability of the SOP system.Furthermore,a method to analyze the uncertainty and sensitivity of the SOP system is proposed.A series of laserinduced shock experiments were conducted at the‘Shenguang-Ⅱ’laser facility to verify the reliability of the SOP system for temperature measurements at tens of thousands of kelvin.The measured temperature of the quartz in our experiments agreed fairly well with previous works,which serves as evidence for the reliability of the SOP system.