The separation efficiency of biopolymers with a short column in liquid chromatography has been investigated in this paper. It was found that the column length has slight effect on the resolution of biopolymers under g...The separation efficiency of biopolymers with a short column in liquid chromatography has been investigated in this paper. It was found that the column length has slight effect on the resolution of biopolymers under gradient elution. The reasons have been explained by stoichiometric displacement model for retention of solute. The column 1.0 cm long was also used in the separation and purification of recombinant human granulocyte colony-simulating factor (rhG-CSF). It only took 40 min and the purity by one step was found to be almost 100%.展开更多
Based on a series of previous studies, an experiment on the integral seismic behavior of a 1/3 scaled model of two-bay and three-story reinforced concrete frame with split columns at lower two stories is performed und...Based on a series of previous studies, an experiment on the integral seismic behavior of a 1/3 scaled model of two-bay and three-story reinforced concrete frame with split columns at lower two stories is performed under cyclic loading. The original columns at lower two stories of the model frame are short columns and they are replaced by the split columns. The hysteresis curves between the horizontal cyclic load and the lateral displacement at the top of the model frame, indicate that under the cyclic loading, the model frame undergoes the process of cracking, yielding, and maximum loading before being destroyed at the ultimate load. They also indicate that the model frame has better ductility, and the ratio of the ultimate displacement to the yielding displacement, reaches 6.0. The yielding process of the model frame shows that for the frame with split columns, plastic hinges are generated at the ends of beams and then the columns begin yielding while the frame still possesses the bearing and deformation capacity. The design idea of directly changing the short column to long one in the reinforced concrete frame may be realized by replacing the short column with the split one.展开更多
文摘The separation efficiency of biopolymers with a short column in liquid chromatography has been investigated in this paper. It was found that the column length has slight effect on the resolution of biopolymers under gradient elution. The reasons have been explained by stoichiometric displacement model for retention of solute. The column 1.0 cm long was also used in the separation and purification of recombinant human granulocyte colony-simulating factor (rhG-CSF). It only took 40 min and the purity by one step was found to be almost 100%.
基金Supported by National Science Fund for Distinguished Young Scholars of China( No. 50425824
文摘Based on a series of previous studies, an experiment on the integral seismic behavior of a 1/3 scaled model of two-bay and three-story reinforced concrete frame with split columns at lower two stories is performed under cyclic loading. The original columns at lower two stories of the model frame are short columns and they are replaced by the split columns. The hysteresis curves between the horizontal cyclic load and the lateral displacement at the top of the model frame, indicate that under the cyclic loading, the model frame undergoes the process of cracking, yielding, and maximum loading before being destroyed at the ultimate load. They also indicate that the model frame has better ductility, and the ratio of the ultimate displacement to the yielding displacement, reaches 6.0. The yielding process of the model frame shows that for the frame with split columns, plastic hinges are generated at the ends of beams and then the columns begin yielding while the frame still possesses the bearing and deformation capacity. The design idea of directly changing the short column to long one in the reinforced concrete frame may be realized by replacing the short column with the split one.