Short-chain chlorinated paraffins(SCCPs) are produced in high volume and have the high potential to pose a threat to human health. However, little information is available for SCCP contamination in human blood/plasma/...Short-chain chlorinated paraffins(SCCPs) are produced in high volume and have the high potential to pose a threat to human health. However, little information is available for SCCP contamination in human blood/plasma/serum, mainly due to the difficulty of sample preparation and quantitative analysis. A method using high resolution gas chromatography coupled with electron capture negative ionization low resolution mass spectrometry(HRGC–ECNI/LRMS) was developed and validated to measure SCCPs in human plasma. The pretreatment process included protein denaturation and lipid elimination, liquid–liquid extraction with a mixture of n-hexane/dichloromethane(1:1, V/V), and cleanup on a multilayer silica column. The blank controls, including procedural blank, vacuum blood collection tube blank, and instrumental blank, were the most pivotal points for the reliable analysis of SCCPs. The average value of procedural blanks was 9.0 ng/g; and the method detection limit(MDL), calculated as the sum of the average procedural blank value and 3 times of the standard deviation of the procedural blanks, was 12.6 ng/g plasma. The validated method was applied to measure the concentrations of the total SCCPs(∑ SCCPs) in50 plasma samples from a general population. The measured plasma concentrations of ∑SCCPs ranged from <MDL to 203 ng/g wet weight(ww), with an average value of 32.0 ng/g ww.The relative abundance profiles of SCCPs in plasma samples were dominated by C10- and C11-CP congener groups centered on Cl6–7. The developed method can be used for the comprehensive and large-scale investigation of SCCP levels in human plasma.展开更多
Chlorinated paraffins(SCCPs) are widely used worldwide, and they can be released into the environment during their production, transport, usage and disposal, which pose potential risks for human health. In this work...Chlorinated paraffins(SCCPs) are widely used worldwide, and they can be released into the environment during their production, transport, usage and disposal, which pose potential risks for human health. In this work, an efficient, reliable and rapid pretreatment method based on matrix solid-phase dispersion(MSPD) was developed for the analysis of short-chain CPs(SCCPs) in human placenta by gas chromatograph-electron capture negative ion low-resolution mass spectrometry(GC-ECNI-LRMS) and gas chromatography–quadrupole time-of-flight mass spectrometry(GC–QTOF-HRMS). The MSPD-relevant parameters including dispersing sorbent,sample-to-sorbent mass ratio, and elution solvent were optimized using the orthogonal test.Silica gel was found to be the optimal dispersing sorbent among the selected matrices. Under the optimal conditions, 44% acidic silica gel can be used as the co-sorbent to remove lipid and eluted by the mixture of hexane and dichloromethane(7:3, V/V). The spiked recoveries of the optimized method were 77.4% and 91.4% for analyzing SCCPs in human placenta by GC-ECNI-LRMS and GC–QTOF-HRMS, and the corresponding relative standard deviations were10.2% and 5.6%, respectively. The method detection limit for the total SCCPs was 36.8 ng/g(dry weight, dw) and 19.2 ng/g(dw) as measured by GC-ECNI-LRMS and GC–QTOF-HRMS,respectively. The concentrations of SCCPs in four human placentas were in the range of展开更多
Short chain chlorinated paraffins (SCCPs) are not only research focus of environmental issues but also interesting model mol- ecules for organic chemistry which exhibit diverse conformation preference and intramolec...Short chain chlorinated paraffins (SCCPs) are not only research focus of environmental issues but also interesting model mol- ecules for organic chemistry which exhibit diverse conformation preference and intramolecular noncovalent interactions (NCIs). A systematic study was conducted to reveal the conlk)rmation preference and the related intramolecular NCIs in two C^-isomers of SCCPs, 5,5,6,6-tetrachlorodecane and 4,4,6,6-1etrachlorodecane. The overall conformation profile was deter- mined on the basis of relative energies calculated at the MP2/6-311++G(d,p) level with the geometries optimized by B3LYP/6-31 l++G(d,p) method. Then, quantum theory of atoms in molecules (QTAIM) has been adopted to identify the NCls in the selected conformers of the model molecules at both B31~YP/6-31 l++G(d,p) and M06-2X/aug-cc-pvdz level. Different chlorine substitution modes result in varied conformation preference. No obvious gauche effect can be observed tk)r the SCCPs with chlorination on adjacent carbon atoms. The most stable conformer of 5,5,6,6-tetrachlorodecane (tTt) has its three dihedral angles in the T configuration, and there is no intramolecular N(3s found in this molecule. On the contrary, the chlorination on interval carbon atoms favors the adoption of gauche configmation for the H C C CI axis. Not only inlramolecular H-..CI contacts but also H---H interactions have been identified as driving forces to compensate the instability from steric crowding ot the gauche configuration. The gggg and g'g'g'g' conformers are the most popular ones, while the populations of tggg and tg'g'g' conformer are second to those of the gggg and g'g'g'g' conformers. Meanwhile, the M06-2X method with large basis sets is preferred for identification of subtle intramolecular NCIs in large molecules like SCCPs.展开更多
Short chain chlorinated paraffins (SCCPs) are possibly persistent organic pollutants (POPs), and are candidate POPs of the Stockholm Convention. In this study, three quantitative methods for analyzing CPs were compare...Short chain chlorinated paraffins (SCCPs) are possibly persistent organic pollutants (POPs), and are candidate POPs of the Stockholm Convention. In this study, three quantitative methods for analyzing CPs were compared using a gas chromatograph-electron capture detector (GC-ECD), gas chromatograph-electron capture negative ion low resolution mass spectrometry (GC-ECNI-LRMS) and gas chromatograph-electron ionization tandem mass spectrometry (GC-EI-MS2). A quantitative method for the analysis of total CPs in soil samples was established. The environmental levels of CPs in an e-waste dismantling area in China were evaluated.展开更多
基金supported by the National Natural Science Foundation of China (No.21337002)the National Basic Research Program (973) of China (No.2015CB453100)
文摘Short-chain chlorinated paraffins(SCCPs) are produced in high volume and have the high potential to pose a threat to human health. However, little information is available for SCCP contamination in human blood/plasma/serum, mainly due to the difficulty of sample preparation and quantitative analysis. A method using high resolution gas chromatography coupled with electron capture negative ionization low resolution mass spectrometry(HRGC–ECNI/LRMS) was developed and validated to measure SCCPs in human plasma. The pretreatment process included protein denaturation and lipid elimination, liquid–liquid extraction with a mixture of n-hexane/dichloromethane(1:1, V/V), and cleanup on a multilayer silica column. The blank controls, including procedural blank, vacuum blood collection tube blank, and instrumental blank, were the most pivotal points for the reliable analysis of SCCPs. The average value of procedural blanks was 9.0 ng/g; and the method detection limit(MDL), calculated as the sum of the average procedural blank value and 3 times of the standard deviation of the procedural blanks, was 12.6 ng/g plasma. The validated method was applied to measure the concentrations of the total SCCPs(∑ SCCPs) in50 plasma samples from a general population. The measured plasma concentrations of ∑SCCPs ranged from <MDL to 203 ng/g wet weight(ww), with an average value of 32.0 ng/g ww.The relative abundance profiles of SCCPs in plasma samples were dominated by C10- and C11-CP congener groups centered on Cl6–7. The developed method can be used for the comprehensive and large-scale investigation of SCCP levels in human plasma.
基金supported by the National Natural Science Foundation of China(Nos.21625702,21337002,21621064)the National Basic Research Program of China(No.2015CB453102)the Strategic Priority Research Program of the Chinese Academy of Science(No.XDB14010400)for the joint financial support
文摘Chlorinated paraffins(SCCPs) are widely used worldwide, and they can be released into the environment during their production, transport, usage and disposal, which pose potential risks for human health. In this work, an efficient, reliable and rapid pretreatment method based on matrix solid-phase dispersion(MSPD) was developed for the analysis of short-chain CPs(SCCPs) in human placenta by gas chromatograph-electron capture negative ion low-resolution mass spectrometry(GC-ECNI-LRMS) and gas chromatography–quadrupole time-of-flight mass spectrometry(GC–QTOF-HRMS). The MSPD-relevant parameters including dispersing sorbent,sample-to-sorbent mass ratio, and elution solvent were optimized using the orthogonal test.Silica gel was found to be the optimal dispersing sorbent among the selected matrices. Under the optimal conditions, 44% acidic silica gel can be used as the co-sorbent to remove lipid and eluted by the mixture of hexane and dichloromethane(7:3, V/V). The spiked recoveries of the optimized method were 77.4% and 91.4% for analyzing SCCPs in human placenta by GC-ECNI-LRMS and GC–QTOF-HRMS, and the corresponding relative standard deviations were10.2% and 5.6%, respectively. The method detection limit for the total SCCPs was 36.8 ng/g(dry weight, dw) and 19.2 ng/g(dw) as measured by GC-ECNI-LRMS and GC–QTOF-HRMS,respectively. The concentrations of SCCPs in four human placentas were in the range of
基金the Chinese Academy of Sciences (KZCX2-YW-BR-25, XDB14030500, YSW2013B01)the National High Technology Research and Development Program of China (2013AA065201)
文摘Short chain chlorinated paraffins (SCCPs) are not only research focus of environmental issues but also interesting model mol- ecules for organic chemistry which exhibit diverse conformation preference and intramolecular noncovalent interactions (NCIs). A systematic study was conducted to reveal the conlk)rmation preference and the related intramolecular NCIs in two C^-isomers of SCCPs, 5,5,6,6-tetrachlorodecane and 4,4,6,6-1etrachlorodecane. The overall conformation profile was deter- mined on the basis of relative energies calculated at the MP2/6-311++G(d,p) level with the geometries optimized by B3LYP/6-31 l++G(d,p) method. Then, quantum theory of atoms in molecules (QTAIM) has been adopted to identify the NCls in the selected conformers of the model molecules at both B31~YP/6-31 l++G(d,p) and M06-2X/aug-cc-pvdz level. Different chlorine substitution modes result in varied conformation preference. No obvious gauche effect can be observed tk)r the SCCPs with chlorination on adjacent carbon atoms. The most stable conformer of 5,5,6,6-tetrachlorodecane (tTt) has its three dihedral angles in the T configuration, and there is no intramolecular N(3s found in this molecule. On the contrary, the chlorination on interval carbon atoms favors the adoption of gauche configmation for the H C C CI axis. Not only inlramolecular H-..CI contacts but also H---H interactions have been identified as driving forces to compensate the instability from steric crowding ot the gauche configuration. The gggg and g'g'g'g' conformers are the most popular ones, while the populations of tggg and tg'g'g' conformer are second to those of the gggg and g'g'g'g' conformers. Meanwhile, the M06-2X method with large basis sets is preferred for identification of subtle intramolecular NCIs in large molecules like SCCPs.
基金supported by the National Basic Research Program of China (2009CB421605)the National Natural Science Foundation (20897010, 20737003)+1 种基金the Knowledge Innovation Program of the Chinese Academy of Sciences (RCEES-QN-200703)the Special Funds for Young Scholars of RCEES, CAS
文摘Short chain chlorinated paraffins (SCCPs) are possibly persistent organic pollutants (POPs), and are candidate POPs of the Stockholm Convention. In this study, three quantitative methods for analyzing CPs were compared using a gas chromatograph-electron capture detector (GC-ECD), gas chromatograph-electron capture negative ion low resolution mass spectrometry (GC-ECNI-LRMS) and gas chromatograph-electron ionization tandem mass spectrometry (GC-EI-MS2). A quantitative method for the analysis of total CPs in soil samples was established. The environmental levels of CPs in an e-waste dismantling area in China were evaluated.