期刊文献+
共找到13,034篇文章
< 1 2 250 >
每页显示 20 50 100
An Algorithm for Short-Circuit Current Interval in Distribution Networks with Inverter Type Distributed Generation Based on Affine Arithmetic
1
作者 Yan Zhang Bowen Du +3 位作者 Benren Pan GuannanWang Guoqiang Xie Tong Jiang 《Energy Engineering》 EI 2024年第7期1903-1920,共18页
During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in unc... During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in uncertainties in the calculation of the short-circuit current at the time of a fault.Additionally,the impacts of such uncertainties around short-circuit currents will increase with the increase of distributed power sources.Thus,it is very important to develop a method for calculating the short-circuit current while considering the uncertainties in a distribution network.In this study,an affine arithmetic algorithm for calculating short-circuit current intervals in distribution networks with distributed power sources while considering power fluctuations is presented.The proposed algorithm includes two stages.In the first stage,normal operations are considered to establish a conservative interval affine optimization model of injection currents in distributed power sources.Constrained by the fluctuation range of distributed generation power at the moment of fault occurrence,the model can then be used to solve for the fluctuation range of injected current amplitudes in distributed power sources.The second stage is implemented after a malfunction occurs.In this stage,an affine optimization model is first established.This model is developed to characterizes the short-circuit current interval of a transmission line,and is constrained by the fluctuation range of the injected current amplitude of DG during normal operations.Finally,the range of the short-circuit current amplitudes of distribution network lines after a short-circuit fault occurs is predicted.The algorithm proposed in this article obtains an interval range containing accurate results through interval operation.Compared with traditional point value calculation methods,interval calculation methods can provide more reliable analysis and calculation results.The range of short-circuit current amplitude obtained by this algorithm is slightly larger than those obtained using the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Therefore,the proposed algorithm has good suitability and does not require iterative calculations,resulting in a significant improvement in computational speed compared to the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Furthermore,the proposed algorithm can provide more reliable analysis and calculation results,improving the safety and stability of power systems. 展开更多
关键词 short circuit calculation inverter type distributed power supplies affine arithmetic distribution network
下载PDF
Fluid-chemical modeling of the near-cathode sheath formation process in a high current broken in DC air circuit breaker
2
作者 彭世东 李静 +3 位作者 段薇 曹云东 刘树鑫 黄浩 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期523-538,共16页
When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop thr... When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop through the near-electrode sheath is an important means to build up the arc voltage, which directly determines the current-limiting performance of the DCCB. A numerical model to describe the near-electrode sheath formation process can provide insight into the physical mechanism of the arc formation, and thus provide a method for arc energy regulation. In this work, we establish a two-dimensional axisymmetric time-varying model of a medium-voltage DCCB arc when interrupted by high current based on a fluid-chemical model involving 16 kinds of species and 46 collision reactions. The transient distributions of electron number density, positive and negative ion number density, net space charge density, axial electric field, axial potential between electrodes, and near-cathode sheath are obtained from the numerical model. The computational results show that the electron density in the arc column increases, then decreases, and then stabilizes during the near-cathode sheath formation process, and the arc column's diameter gradually becomes wider. The 11.14 V–12.33 V drops along the17 μm space charge layer away from the cathode(65.5 k V/m–72.5 k V/m) when the current varies from 20 k A–80 k A.The homogeneous external magnetic field has little effect on the distribution of particles in the near-cathode sheath core,but the electron number density at the near-cathode sheath periphery can increase as the magnetic field increases and the homogeneous external magnetic field will lead to arc diffusion. The validity of the numerical model can be proven by comparison with the experiment. 展开更多
关键词 near-cathode sheath atmospheric pressure air arc fluid-chemical model high current DC air circuit breaker(DCCB)
下载PDF
Study on Effects of Short Circuit Between High and Common Ends of LVDT's Lead Wires on Sum Voltage
3
作者 HE Zhiheng BAO Yan +3 位作者 SHANG Jie REN Zhengjia PI Ligang ZHAO Yiyue 《International Journal of Plant Engineering and Management》 2024年第3期142-153,共12页
The Linear variable differential transformer(LVDT)is widely used in the aircraft field and crucial to the safety of the aircraft.Based on the short-circuit failure mode between the high and common ends of the LVDT′s ... The Linear variable differential transformer(LVDT)is widely used in the aircraft field and crucial to the safety of the aircraft.Based on the short-circuit failure mode between the high and common ends of the LVDT′s lead wires,the theoretical formula of short-circuit sum voltage was deduced and verified via tests.Moreover,the effects of the core length and the winding resistance on the short-circuit sum voltage were analyzed and discussed through numerical methods.The present research put forward some references for LVDT′s design. 展开更多
关键词 LVDTs sum voltage short circuit
下载PDF
Data-driven short circuit resistance estimation in battery safety issues 被引量:1
4
作者 Yikai Jia Jun Xu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第4期37-44,共8页
Developing precise and fast methods for short circuit detection is crucial for preventing or mitigating the risk of safety issues of lithium-ion batteries(LIBs).In this paper,we developed a Convolutional Neural Networ... Developing precise and fast methods for short circuit detection is crucial for preventing or mitigating the risk of safety issues of lithium-ion batteries(LIBs).In this paper,we developed a Convolutional Neural Networks(CNN)based model that can quickly and precisely predict the short circuit resistance of LIB cells during various working conditions.Cycling tests of cells with an external short circuit(ESC)are produced to obtain the database and generate the training/testing samples.The samples are sequences of voltage,current,charging capacity,charging energy,total charging capacity,total charging energy with a length of 120 s and frequency of 1 Hz,and their corresponding short circuit resistances.A big database with~6×10^(5)samples are generated,covering various short circuit resistances(47~470Ω),current loading modes(Constant current-constant voltage(CC-CV)and drive cycle),and electrochemical states(cycle numbers from 1 to 300).Results show that the average relative absolute error of five random sample splits is 6.75%±2.8%.Further parametric analysis indicates the accuracy estimation benefits from the appropriate model setups:the optimized input sequence length(~120 s),feature selection(at least one total capacity-related variable),and rational model design,using multiple layers with different kernel sizes.This work highlights the capabilities of machine learning algorithms and data-driven methodologies in real-time safety risk prediction for batteries. 展开更多
关键词 Lithium-ion battery Safety risk Internal short circuit short circuit resistance Convolutional neural networks
下载PDF
A Fault Feature Extraction Model in Synchronous Generator under Stator Inter-Turn Short Circuit Based on ACMD and DEO3S 被引量:1
5
作者 Yuling He Shuai Li +1 位作者 Chao Zhang Xiaolong Wang 《Structural Durability & Health Monitoring》 EI 2023年第2期115-130,共16页
This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fa... This paper proposed a new diagnosis model for the stator inter-turn short circuit fault in synchronous generators.Different from the past methods focused on the current or voltage signals to diagnose the electrical fault,the sta-tor vibration signal analysis based on ACMD(adaptive chirp mode decomposition)and DEO3S(demodulation energy operator of symmetrical differencing)was adopted to extract the fault feature.Firstly,FT(Fourier trans-form)is applied to the vibration signal to obtain the instantaneous frequency,and PE(permutation entropy)is calculated to select the proper weighting coefficients.Then,the signal is decomposed by ACMD,with the instan-taneous frequency and weighting coefficient acquired in the former step to obtain the optimal mode.Finally,DEO3S is operated to get the envelope spectrum which is able to strengthen the characteristic frequencies of the stator inter-turn short circuit fault.The study on the simulating signal and the real experiment data indicates the effectiveness of the proposed method for the stator inter-turn short circuit fault in synchronous generators.In addition,the comparison with other methods shows the superiority of the proposed model. 展开更多
关键词 Synchronous generator stator inter-turn short circuit vibration signal processing adaptive chirp mode decomposition demodulation energy operator of symmetrical differencing
下载PDF
Effects of current waveform parameters during droplet transfer on spatter in high speed waveform controlled Short-circuiting GMAW 被引量:4
6
作者 吕小青 曹彪 +1 位作者 曾敏 黄增好 《China Welding》 EI CAS 2005年第2期121-124,共4页
Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been... Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been investigated by experimental method. The welding power source used for the research is an inverter with a special current waveform control. It is shown that the spatter decreases at first then increases with each increase of the low current period, current increase rate and the maximum current limit. The test results are provided for welding of 1 mm and 3 mm mild steel at speed of 1.2 m/min. The stable GMA W-S process under high speed welding condition has been achieved by optimizing the parameters. 展开更多
关键词 gas metal arc welding short circuit arc current waveform control high speed welding SPATTER
下载PDF
Influence of optical interference and carrier lifetime on the short circuit current density of organic bulk heterojunction solar cells 被引量:1
7
作者 游海龙 张春福 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第1期349-356,共8页
Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important r... Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important role in the determination of Jsc; and obvious oscillatory behaviour of Jsc was observed as a function of thickness. At the same time, the influence of the carrier lifetime on Jsc also cannot be neglected. When the carrier lifetime is relatively short, Jsc only increases at the initial stage and then decreases rapidly with the increase of active layer thickness. However, for a relatively long carrier lifetime, the exciton dissociation probability must be considered, and Jsc behaves wave-like with the increase of active layer thickness. The validity of this model is confirmed by the experimental results. 展开更多
关键词 organic solar cells short circuit current density optical interference carrier lifetime
下载PDF
Analysis of Short-circuit Characteristics and Calculation of Steady-state Short-circuit Current for DFIG Wind Turbine 被引量:1
8
作者 Xiong, Xiaofu Ouyang, Jinxin 《电力系统自动化》 EI CSCD 北大核心 2012年第8期115-121,共7页
Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a signifi... Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a significant issue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied to the DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning,protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetric short-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.A new method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions.The time-domain simulations are conducted to verify the accuracy of the proposed method. 展开更多
关键词 双馈风力发电机 短路电流 短路特性 计算 变速恒频 稳态 双馈感应发电机 非对称短路
下载PDF
Low switching loss and increased short-circuit capability split-gate SiC trench MOSFET with p-type pillar
9
作者 沈培 王颖 +2 位作者 李兴冀 杨剑群 曹菲 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期682-689,共8页
A split-gate SiC trench gate MOSFET with stepped thick oxide, source-connected split-gate(SG), and p-type pillar(ppillar) surrounded thick oxide shielding region(GSDP-TMOS) is investigated by Silvaco TCAD simulations.... A split-gate SiC trench gate MOSFET with stepped thick oxide, source-connected split-gate(SG), and p-type pillar(ppillar) surrounded thick oxide shielding region(GSDP-TMOS) is investigated by Silvaco TCAD simulations. The sourceconnected SG region and p-pillar shielding region are introduced to form an effective two-level shielding, which reduces the specific gate–drain charge(Q_(gd,sp)) and the saturation current, thus reducing the switching loss and increasing the short-circuit capability. The thick oxide that surrounds a p-pillar shielding region efficiently protects gate oxide from being damaged by peaked electric field, thereby increasing the breakdown voltage(BV). Additionally, because of the high concentration in the n-type drift region, the electrons diffuse rapidly and the specific on-resistance(Ron,sp) becomes smaller.In the end, comparing with the bottom p~+ shielded trench MOSFET(GP-TMOS), the Baliga figure of merit(BFOM,BV~2/R_(on,sp)) is increased by 169.6%, and the high-frequency figure of merit(HF-FOM, R_(on,sp) × Q_(gd,sp)) is improved by310%, respectively. 展开更多
关键词 SiC gate trench MOSFET gate oxide reliability switching loss gate–drain charge(Q_(gd sp)) short circuit
下载PDF
An Adaptive Slope Compensation Circuit for Peak Current Mode of Boost Switching Power Supply
10
作者 Fu Lin Xianguo Cao 《Open Journal of Applied Sciences》 2023年第10期1730-1741,共12页
Based on the analysis of the basic principle of slope compensation, a high-precision adaptive slope compensation circuit for peak current mode boost DC/DC converter is designed. The circuit dynamically detects the inp... Based on the analysis of the basic principle of slope compensation, a high-precision adaptive slope compensation circuit for peak current mode boost DC/DC converter is designed. The circuit dynamically detects the input and output voltage of the boost circuit to realize automatic adjustment of the compensation amount with the change of duty ratio, which makes the ramp compensation slope optimized. The design uses a high-precision subtracter to improve the accuracy of slope compensation. While eliminating sub-slope oscillation and improving the stability of boost circuit, the negative impact of compensation on boost circuit is minimized, and the load capacity and transient response speed of boost circuit are guaranteed. The circuit is designed based on SMIC 0.18um CMOS technology, with simple structure, high reliability and easy engineering implementation. Spectre circuit simulator 17.1.0.124 64b simulation results show that the circuit has high compensation accuracy and wide input and output voltage range. When the working voltage is 3.3 V, the compensation slope can be adjusted adaptively under different duty cycles, and the minimum error between the compensation slope and the theoretical optimal compensation slope is only 0.42%. 展开更多
关键词 Adaptive Slope Compensation Boost circuit Peak current Mode SUBTRACTER ACCURACY
下载PDF
Short-circuit Current Characteristics of Wind Generators
11
作者 Seung-Jae LEE Myeon-Song CHOI 《电力系统自动化》 EI CSCD 北大核心 2012年第8期110-114,共5页
To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreemen... To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results. 展开更多
关键词 风力发电机组 短路电流 电流特性 配电系统 PSCAD 过流继电器 IEEE 通过检测
下载PDF
Effect of welding speed and electrode extension on the approximate entropy of welding current in short-circuiting GMAW 被引量:2
12
作者 向远鹏 曹彪 +1 位作者 曾敏 黄石生 《China Welding》 EI CAS 2007年第3期56-62,共7页
Based on the phase space reconstruction of welding current in short-circuiting transfer arc welding under carbon dioxide, the approximate entropy of welding current and its standard deviation have been calculated and ... Based on the phase space reconstruction of welding current in short-circuiting transfer arc welding under carbon dioxide, the approximate entropy of welding current and its standard deviation have been calculated and analyzed at different welding speeds and different electrode extensions respectively. The experimental and calculated results show that at a certain arc voltage, wire feeding rate and gas flow rate, welding speed and electrode extension have significant effects not only on the approximate entropy of welding current, but also on the stability of welding process. Further analysis proves that when the welding speed and electrode extension are in an appropriate range respectively, the welding current approximate entropy attains maximum and its standard deviation minimum. Just under such circumstances, the welding process is in the most stable state. 展开更多
关键词 gas metal arc welding short-circuiting transfer approximate entropy STABILITY
下载PDF
Study on Short Circuit Current Calculation of Power System with UHVDC and New Energy Source
13
作者 Zaihua Li Huan Yan +1 位作者 Yunting Song Jincheng Guo 《Energy and Power Engineering》 2017年第4期625-634,共10页
With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the sh... With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the short circuit current. For the power grid that short circuit current level closes to the interrupting capacity of circuit breaker, it’s necessary to fully consider all kinds of influence factors, careful checking, so as to obtain more accurate calculation results of short circuit current. In 2018, two ±800 kV high-power Ultra High Voltage Direct Current (UHVDC) transmission projects will be connected with Shaanxi power grid, accompanied by a lot of concomitant fossil-fuel generating plants as power resource, and also a large number of new energy source, includes wind power generation and photovoltaic power generation. Around one of the UHVDC converter stations, short circuit current may exceed the withstand limit of some certain circuit breakers. In order to get more accurate short circuit current calculation results, three measures are used: 1) contrastive calculation and analysis by algorithm based on schemes and algorithm based on power flow;2) analysis the influence of UHVDC by electromagnetic transient and electromechanical transient hybrid simulation;3) considered a detailed model of Doubly Fed Induction Generator (DFIG) with low voltage ride through characteristics. The calculation results shows that: in the typical operation mode of Shaanxi power grid of 2018, the original calculation results by conventional calculation method are coincident with the results by considering the influence of algorithms, UHVDC and DFIG in large, in which: the results of the algorithm based on power flow are smaller than that of the algorithm based on schemes about 2 - 8 kA;the steady values of the short circuit current provided by UHVDC converterstation (includes rectifiers and smoothing capacitors) are about 0 - 3 kA;the steady values of the short circuit current provided by DFIG are about 0 - 5 kA. The calculation results can provide reference for the selection of the circuit breaker, and it can be verified by fault recording data in the future. 展开更多
关键词 short circuit current UHVDC New Energy SOURCE Hybrid Simulation
下载PDF
Study on Effect of UHV Power Grid Construction Schemes on Short Circuit Current
14
作者 Zaihua Li Feng Gao +3 位作者 Qing Wang Shuang Zhang Hongmei Luo Jian Liang 《Journal of Power and Energy Engineering》 2015年第4期200-205,共6页
The commissioning of Southern Hami-Zhengzhou ±800 kV UHVDC transmission project has important significance to heighten operation reliability, transfer capability and supply electric ability of Henan power grid. H... The commissioning of Southern Hami-Zhengzhou ±800 kV UHVDC transmission project has important significance to heighten operation reliability, transfer capability and supply electric ability of Henan power grid. However, short circuit currents of 500 kV buses in the Center of Henan are almost close to the operation upper limitation. In order to decrease the short circuit currents effectively, it’s necessary to strengthen the network structure of Center of Henan power grid and calculate short circuit currents. Two schemes of strengthening the network structure of Center of Henan power grid are studied. The calculated values of short circuit currents of some important 500 kV buses in the two schemes are still bigger than excepted. According to the latest Plan of State Grid, Yubei UHV substation and Zhumadian UHV substation located in Henan power grid. The calculated values of short circuit currents of some important 500 kV buses with the commissioning of Yubei UHV and Zhumadian UHV are qualified. So, reasonable network structure with UHV is suitable to heighten transfer capability and supply electric ability of Henan power grid. 展开更多
关键词 UHV UHVDC Construction Scheme short circuit current
下载PDF
Fault DiagnosisMethod of Energy Storage Unit of Circuit Breakers Based on EWT-ISSA-BP
15
作者 Tengfei Li Wenhui Zhang +3 位作者 Ke Mi Qingming Lin Shuangwei Zhao Jiayi Song 《Energy Engineering》 EI 2024年第7期1991-2007,共17页
Aiming at the problem of energy storage unit failure in the spring operating mechanism of low voltage circuit breakers(LVCBs).A fault diagnosis algorithm based on an improved Sparrow Search Algorithm(ISSA)optimized Ba... Aiming at the problem of energy storage unit failure in the spring operating mechanism of low voltage circuit breakers(LVCBs).A fault diagnosis algorithm based on an improved Sparrow Search Algorithm(ISSA)optimized Backpropagation Neural Network(BPNN)is proposed to improve the operational safety of LVCB.Taking the 1.5kV/4000A/75kA LVCB as an example.According to the current operating characteristics of the energy storage motor,fault characteristics are extracted based on Empirical Wavelet Transform(EWT).Traditional BPNN has problems such as difficulty adjusting network weights and thresholds,being sensitive to initial weights,and quickly falling into local optimal solutions.The Sparrow Search Algorithm(SSA)with self-adjusting weight factors combined with bidirectional mutations is added to optimize the selection of BPNN hyperparameters.The results show that the ISSA-BPNN can accurately and quickly distinguish six conditions of motor voltage reduction:motor voltage increase,motor voltage decrease,energy storage spring stuck,transmission gear stuck,regular state and energy storage spring not locked.It is suitable for fault diagnosis and detection of the energy storage part of LVCB. 展开更多
关键词 Low voltage circuit breakers energy storage motor current sparrow search algorithm empirical wavelet transform fault diagnosis
下载PDF
Calculation of Eddy Current Loss and Short-circuit Force in SSZ11-50000/110 Power Transformer
16
作者 Yan Li Bo Zhang +2 位作者 Longnv Li Tongxun Yang Ning Wang 《Energy and Power Engineering》 2013年第4期1105-1108,共4页
The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination o... The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss. 展开更多
关键词 Power Transformer FINITE Element short-circuit FORCE EDDY current LOSS Surface IMPEDANCE Method
下载PDF
The simulation research for transient current variation in short circuit fault of urban rail transportation
17
作者 XU Chaoqun YANG Jian YUAN Tianchen 《International English Education Research》 2017年第5期51-53,共3页
Urban rail transit is one of the most important way for urban residents. However, frequent power failure, especially the short fault hinders the safe and stable operation of rail transit. The research of the transient... Urban rail transit is one of the most important way for urban residents. However, frequent power failure, especially the short fault hinders the safe and stable operation of rail transit. The research of the transient variation of line electrical parameters in short circuit fault is the basis of researches for technology of line protection and short circuit fault location. Based on Matlab/Simulink, a 24-pulse rectifier circuit model is established, the resistance and inductance value of the catenary and rail network are calculated. The short Circuit fault simulation model of DC traction power supply system is established. The short-circuit fault of the traction network at close and distant points are simulated, the transient variation values of fault current with the different fault distance are analyzed. The simulation results show that the transient current peak of the nearby short circuit is oscillatory and convergent due to the nonlinear devices, which proves the accuracy of the model and provides a reference for the precise configuration of the line protection equipment. 展开更多
关键词 short circuit fault transient current urban rail transit
下载PDF
Consistency evaluation of the current distribution of short-circuit tests in AT feeding systems for high-speed railways 被引量:1
18
作者 Qing-an Ma Wei Liu 《Journal of Modern Transportation》 2018年第3期163-172,共10页
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However,... To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However, no systematic algorithm yet exists to evaluate the consistency of the current distribution of short-circuit tests. A methodology is proposed in this paper to address this problem. Based on Kirchhoff’s current law and the generalized method of symmetrical components, the current deviations of the AT feeding systems are analysed and then normalized with the short-circuit current as they vary greatly with systems and short-circuit sites. It is also found that the short-circuit current varies with the calculation methods, and its unbiased standard deviation also reflects the consistency of the short-circuit test. The mean and maximum of the current deviations, as well as the unbiased standard deviation of the short-circuit current, show the consistency of the short-circuit test from different aspects,although the last two items are highly relevant. Therefore, a unified evaluation index is defined as the sum of the three items, and then applied in two case studies to test its performance. The results show that, the proposed index canclearly distinguish the consistency of the short-circuit tests and may be used to sort the short-circuit tests for fault location systems. Besides, some short-circuit tests may have very poor consistency indices, and thus are not applicable to the tuning of fault location systems. In the authors’ opinion, the determination of the threshold of the proposed index needs further investigation. 展开更多
关键词 Autotransformer feeding system short-circuittest Consistency evaluation Kirchhoff’s current law Generalized method of symmetrical components
下载PDF
Nonlinear Auto-Companding Method for Behavioral Modeling of Switched-Current Circuits
19
作者 王伟 曾璇 +2 位作者 陶俊 苏仰峰 唐璞山 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2002年第12期1254-1261,共8页
A wavelet collocation method with nonlinear auto companding is proposed for behavioral modeling of switched current circuits.The companding function is automatically constructed according to the initial error distri... A wavelet collocation method with nonlinear auto companding is proposed for behavioral modeling of switched current circuits.The companding function is automatically constructed according to the initial error distribution obtained through approximating the input output function of the SI circuit by conventional wavelet collocation method.In practical applications,the proposed method is a general purpose approach,by which both the small signal effect and the large signal effect are modeled in a unified formulation to ease the process of modeling and simulation.Compared with the published modeling approaches,the proposed nonlinear auto companding method works more efficiently not only in controlling the error distribution but also in reducing the modeling errors.To demonstrate the promising features of the proposed method,several SI circuits are employed as examples to be modeled and simulated. 展开更多
关键词 wavelet collocation method behavioral modeling switched current circuits nonlinear auto companding
下载PDF
CURRENT MODE CIRCUIT SYMBOLIC ANALYSIS WITH MATH-EMATICA
20
作者 滕建辅 李坦 +1 位作者 张泰海 韩志宇 《Transactions of Tianjin University》 EI CAS 1997年第2期19-22,共4页
A practical method of current mode circuit symbolic analysis using Mathematica is proposed. With the powerful symbolic manipulation capacity of Mathematica, current mode circuit symbolic analysis can be significantly ... A practical method of current mode circuit symbolic analysis using Mathematica is proposed. With the powerful symbolic manipulation capacity of Mathematica, current mode circuit symbolic analysis can be significantly simplified. The active devices are modelled by nullors. The examples of current mode filters using CCIIs are presented. 展开更多
关键词 symbolic analysis current mode circuits MATHEMATICA
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部