The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination o...The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss.展开更多
The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial...The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial applications.In this study,two objectives with the same dimensional measurement unit,namely,the total capital investment cost of FCLs and circuit breaker loss related to short-circuit currents,are considered.The circuit breaker loss model is developed based on the attenuation rule of the circuit breaker service life.The circuit breaker loss is used to quantify the current-limiting effect to avoid the problem of weight selection in a multi-objective problem.The IEEE 10-generator 39-bus system in New England is used to evaluate the performance of the proposed genetic algorithm(GA)method.Comparative and sensitivity analyses are performed.The results of the optimized plan are validated through simulations,indicating the significant potential of the GA for such optimization.展开更多
It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and ...It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and short-circuit impedance model of axial dual-low-voltage split-winding transformer is established, and then the 2D and 3D leakage magnetic field are analyzed. Secondly, the short-circuit impedance and split parallel branch current distribution in different working conditions are calculated, which is based on field-circuit coupled method. At last, effectiveness and feasibility of the proposed model is verified by comparison between experiment, analysis and simulation. The results showed that the 3D analysis method is a better approach to calculate the short-circuit impedance, since its analytical value is more closer to the experimental value compared with the 2D analysis results, the finite element method calculation error is less than 2%, while the leakage flux method maximum error is 7.2%.展开更多
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing...It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.展开更多
In this paper,an interleaved LCLC converter with enhancement-mode(E-mode)GaN devices is introduced to achieve the accurate current sharing performance for data center applications. Any tolerance in the resonant tank e...In this paper,an interleaved LCLC converter with enhancement-mode(E-mode)GaN devices is introduced to achieve the accurate current sharing performance for data center applications. Any tolerance in the resonant tank elements can lead to large load imbalance between any two different phases. Due to the steep gain curves of LCLC converters,conventional current sharing methods are not effective. In the proposed converter,the impedances of the resonant networks are matched by switching a capacitor,i.e.,switch controlled capacitor(SCC),in series with the resonant capacitor in one or some of the phases,which results in accurate load current sharing among the phases with an accuracy around 0.025%. The load share of a phase is sensed through the resonant current on it,and the control logic applied to such current sharing can be achieved. By this method,accurate current sharing is achieved for a wide input voltage range required for the hold-up time in data center applications. Interleaving is applied in the proposed multiphase LCLC converter,resulting in low current stress on the output capacitor and allowing ceramic capacitor implementation. Moreover,phase shedding accomplishes high light load efficiency. The performance of the proposed interleaved LCLC converter is verified by a two-phase 1 k W prototype with an input voltage ranging from 250 V to 400 V and a fixed 12 V output voltage.展开更多
A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power ca...A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power cable and outer liquefied natural gas (LNG) pipeline. The flowing LNG could maintain the operating temperature of the inner HTS power cable within the range of 85 K-90 K, thus the Bi-2223 superconductors in the HTS power cable produce little Joule loss with the transmission current below the critical current. Owing to the advantages of high power density, low transmission losses and economical manufacturing costs, the hybrid energy transmission pipeline is expected to be widely utilized in the near future. In order to ensure the safety of the HTS power cable and explosive LNG in case of short-circuit faults, this paper tests and analyzes the characteristics of Bi-2223 HTS tapes of the Type HT-CA, Type HT-SS and Type H models under short-circuit current impacts at the LNG cooling temperature (85 K-90 K). An experimental platform is designed and established for the ampacity tests of HTS tapes above LN2 cooling temperature (77 K). The AC over-current impact tests at 85 K-90 K are carried out on each sample of Bi-2223 tapes respectively, and the experimental results are analyzed and compared to evaluate their performances under different operating conditions. The results indicate that the Type HT-CA tape can withstand 50 Hz short-circuit current impact with the amplitude of 1108 A (10 times of critical current Ic ) for 100 ms at 90 K, and its resistance is the smallest of the three tested samples under similar current impacts. Therefore, the Type HT-CA Bi-2223 tape is the optimal superconductor of the HTS power cable in the hybrid energy transmission pipeline.展开更多
The influence of the cathode work function,carriers mobilities and temperature on the short-circuit current of single layer organic solar cells with Schottkey contacts was numerically studied,and the quantitative depe...The influence of the cathode work function,carriers mobilities and temperature on the short-circuit current of single layer organic solar cells with Schottkey contacts was numerically studied,and the quantitative dependences of the short-circuit current on these quantities were obtained.The results provide the theoretical foundation for experimental study of single layer organic solar cells with Schottkey contacts.展开更多
AIM To investigate the pharmacological effect of Tong XieYao Fang(TXYF) formula, a Chinese herbal formula, on Diarrhea-predominant irritable bowel syndrome(D-IBS) rats.METHODS In a neonatal maternal separation plus re...AIM To investigate the pharmacological effect of Tong XieYao Fang(TXYF) formula, a Chinese herbal formula, on Diarrhea-predominant irritable bowel syndrome(D-IBS) rats.METHODS In a neonatal maternal separation plus restraint stress(NMS + RS) model of D-IBS, male Sprague Dawley rats were randomly divided into two groups(NMS + RS group and TXYF-formula group) with no handlings were used as controls(NH group). Starting from postnatalday 60, rats in TXYF-formula group were administered TXYF-formula(4.92 g/100 g bodyweight) orally twice a day for 14 consecutive days while NH group and NMS + RS group were given distilled water. Using short-circuit current technology, we observed 5-HT-induced changes of current across ion channels, such as cystic fibrosis transmembrane conductance regulator(CFTR) Clchannel, epithelial Na+ channel(ENaC), Ca2+-dependent Cl- channel(CACC), Na+-K+-2Cl- co-transporter(NKCC), and Na+-HCO-3 co-transporter(NBC), in the colonic epithelium of three groups after exposure to drugs and specific blockers with a Power Lab System(AD Instruments International).RESULTS Under basal conditions, the changes of short-circuit current(?Isc, μA/cm2) induced by 5-HT were similar in NH group and TXYF-formula group, and both higher than NMS + RS group(70.86 μA/cm2 ± 12.32 μA/cm2, 67.67 μA/cm2 ± 11.68 μA/cm2 vs 38.8 μA/cm2 ± 7.25 μA/cm2, P < 0.01, respectively). When CACC was blocked by 4,4′-diisothiocyanato-stilbene-2,2′-disulfonic acid, 5-HT-induced ?Isc was smaller in NMS + RS group than in NH group and TXYF-formula group, respectively(48.41 μA/cm2 ± 13.15 μA/cm2 vs 74.62 μA/cm2 ± 10.73 μA/cm2, 69.22 μA/cm2 ± 11.7 μA/cm2, P < 0.05, respectively). The similar result could be obtained when ENaC was blocked by Amiloride(44.69 μA/cm2 ± 12.58 μA/cm2 vs 62.05 μA/cm2 ± 11.26 μA/cm2, 62.11 μA/cm2 ± 12.01 μA/cm2, P < 0.05, respectively). However, when CFTR Cl- channel was blocked by 1,1-dimethyl piperidinium chloride(DPC), 5-HT-induced ?Isc did not significantly differ in three groups(42.28 μA/cm2 ± 10.61 μA/cm2 vs 51.48 μA/cm2 ± 6.56 μA/cm2 vs 47.75 μA/cm2 ± 7.99 μA/cm2, P > 0.05, respectively). The similar results could also be obtained in three groups when NBC and NKCC were respectively blocked by their blockers.CONCLUSION TXYF-formula can regulate the Cl- and HCO-3 secretion of colonic mucosa via CFTR Cl- channel, Cl-/HCO-3 exchanger, NBC and NKCC co-transporters.展开更多
A novel structure of Ag gridlSiN_(x)/n+-c-Si/n-c-Si/i-a-Si:H/p^(+)-a-Si:HlTCO/Ag grid was designed to increase the ef-ficiency of bifacial amorphous/crystalline silicon-based solar cells and reduce the rear material c...A novel structure of Ag gridlSiN_(x)/n+-c-Si/n-c-Si/i-a-Si:H/p^(+)-a-Si:HlTCO/Ag grid was designed to increase the ef-ficiency of bifacial amorphous/crystalline silicon-based solar cells and reduce the rear material consumption and production cost.The simulation results show that the new structure obtains higher efficiency compared with the typical bifa-cial amorphous/crystalline silicon-based solar cell because of an increase in the short-circuit current(J_(sc)),while retaining the advantages of a high open-circuit voltage,low temperature coefficient,and good weak-light performance.Moreover,real cells composed of the novel structure with dimensions of 75 mm×75 mm were fabricated by a special fabrication recipe based on industrial processes.Without parameter optimization,the cell efficiency reached 21.1%with the J_(sc)of 41.7 mA/cm^(2).In addition,the novel structure attained 28.55%potential conversion efficiency under an illumination of AM 1.5 G,100 mW/cm^(2).We conclude that the configuration of the Ag grid/SiN_(x)/n^(+)-c-Si/n-c-Si/i-a-Si:H/p^(+)-a-Si:H/TCO/Ag grid is a promising structure for high efficiency and low cost.展开更多
Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to inc...Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to increase additional equipment investments. Fast power electronics controlled flexible AC transmission system(FACTS)devices have opened a new way for suppressing the fault current levels, while maintaining their normal functionalities for steady-state and transient power system operation and control. Thyristor controlled phase shifting transformer(TCPST) is a beneficial FACTS device in modern power systems, which is capable of regulating regional powerflow. The mathematical model for TCPST under different operation modes is firstly investigated in this study. Intuitively, the phase shifting angle control can adjust the equivalent impedance of TCPST, but the effect has been demonstrated to be weak. Therefore, a novel transformer excitation impedance switching(EIS) control method, is proposed for fault current suppressing, according to the impedance characteristics of TCPST. Simulation results on IEEE 14-bus system have shown considerable current limiting characteristic of the EIS control under various fault types. Also, analysis of the timing requirement during fault interruption, overvoltage phenomenon, and ancillary mechanical support issues during EIS control is discussed,so as to implement the proposed EIS control properly for fast fault current suppression.展开更多
A data acquisition system based on LabVIEW is designed and implemented, and electro-discharge(ED) fine truing of metal-bonded fine-grain diamond wheel based on real-time monitoring is researched. Real-time monitoring ...A data acquisition system based on LabVIEW is designed and implemented, and electro-discharge(ED) fine truing of metal-bonded fine-grain diamond wheel based on real-time monitoring is researched. Real-time monitoring not only makes efficient impulse specification of ED truing easily obtained, but also is good for timely identifying no-load, avoiding short circuit and arc discharge phenomena and then for obtaining normal machining state. ED fine truing of the fine-grain wheel includes two steps: rough truing for high efficiency and fine truing for high precision. Final ED truing precision and efficiency not only depend on electric process specification, but also is concerned with electrode shape, insulated performance of operating fluid and vertical feed quantity value and frequency. Experiments indicate that ED fine truing based on real-time monitoring can improve the truing precision and efficiency. Average machining efficiency of W10 wheel is about 0.95 μm/min; the final run-out by ED truing is less than 2 μm.展开更多
The d-axis inductance(Ld)of the negative-salient permanent magnet synchronous motor(NSPMSM)is larger than the q-axis inductance(Lq).Compared with the traditional motor,the NSPMSM has the characteristics of a high over...The d-axis inductance(Ld)of the negative-salient permanent magnet synchronous motor(NSPMSM)is larger than the q-axis inductance(Lq).Compared with the traditional motor,the NSPMSM has the characteristics of a high overload capacity,wide speed range,and preventing permanent magnet demagnetization.Positive d-axis current(id)is applied to control positive reluctance torque when running at base speed.When the motor is running at high speed,a relatively small id can achieve speed expansion and effectively expand the motor flux-weakening range.The use of a magnetic bridge to increase the Ld and a W-type permanent magnet to reduce the Lq is proposed in this article as a novel NSPMSM rotor structure.Firstly,the working principle of the NSPMSM was determined according to the equivalent magnetic circuit.Secondly,using the finite element method,the influence of motor structure on torque and speed performance of NSPMSM was analyzed,and the motor structure was optimized.Thirdly,the effect of the internal power factor angle on the performance of the two motors is analyzed.Finally,the short circuit simulation and analysis verified that the NSPMSM has a stronger short circuit current suppression ability without sacrificing overload ability.展开更多
文摘The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss.
基金supported by State Grid Science and Technology Projects(SGTYHT/17-JS-199)National Natural Science Foundation of China(51577163).
文摘The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial applications.In this study,two objectives with the same dimensional measurement unit,namely,the total capital investment cost of FCLs and circuit breaker loss related to short-circuit currents,are considered.The circuit breaker loss model is developed based on the attenuation rule of the circuit breaker service life.The circuit breaker loss is used to quantify the current-limiting effect to avoid the problem of weight selection in a multi-objective problem.The IEEE 10-generator 39-bus system in New England is used to evaluate the performance of the proposed genetic algorithm(GA)method.Comparative and sensitivity analyses are performed.The results of the optimized plan are validated through simulations,indicating the significant potential of the GA for such optimization.
文摘It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and short-circuit impedance model of axial dual-low-voltage split-winding transformer is established, and then the 2D and 3D leakage magnetic field are analyzed. Secondly, the short-circuit impedance and split parallel branch current distribution in different working conditions are calculated, which is based on field-circuit coupled method. At last, effectiveness and feasibility of the proposed model is verified by comparison between experiment, analysis and simulation. The results showed that the 3D analysis method is a better approach to calculate the short-circuit impedance, since its analytical value is more closer to the experimental value compared with the 2D analysis results, the finite element method calculation error is less than 2%, while the leakage flux method maximum error is 7.2%.
文摘It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.
文摘In this paper,an interleaved LCLC converter with enhancement-mode(E-mode)GaN devices is introduced to achieve the accurate current sharing performance for data center applications. Any tolerance in the resonant tank elements can lead to large load imbalance between any two different phases. Due to the steep gain curves of LCLC converters,conventional current sharing methods are not effective. In the proposed converter,the impedances of the resonant networks are matched by switching a capacitor,i.e.,switch controlled capacitor(SCC),in series with the resonant capacitor in one or some of the phases,which results in accurate load current sharing among the phases with an accuracy around 0.025%. The load share of a phase is sensed through the resonant current on it,and the control logic applied to such current sharing can be achieved. By this method,accurate current sharing is achieved for a wide input voltage range required for the hold-up time in data center applications. Interleaving is applied in the proposed multiphase LCLC converter,resulting in low current stress on the output capacitor and allowing ceramic capacitor implementation. Moreover,phase shedding accomplishes high light load efficiency. The performance of the proposed interleaved LCLC converter is verified by a two-phase 1 k W prototype with an input voltage ranging from 250 V to 400 V and a fixed 12 V output voltage.
基金supported by National Key R&D Project under Grant(2018YFB0904400).
文摘A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power cable and outer liquefied natural gas (LNG) pipeline. The flowing LNG could maintain the operating temperature of the inner HTS power cable within the range of 85 K-90 K, thus the Bi-2223 superconductors in the HTS power cable produce little Joule loss with the transmission current below the critical current. Owing to the advantages of high power density, low transmission losses and economical manufacturing costs, the hybrid energy transmission pipeline is expected to be widely utilized in the near future. In order to ensure the safety of the HTS power cable and explosive LNG in case of short-circuit faults, this paper tests and analyzes the characteristics of Bi-2223 HTS tapes of the Type HT-CA, Type HT-SS and Type H models under short-circuit current impacts at the LNG cooling temperature (85 K-90 K). An experimental platform is designed and established for the ampacity tests of HTS tapes above LN2 cooling temperature (77 K). The AC over-current impact tests at 85 K-90 K are carried out on each sample of Bi-2223 tapes respectively, and the experimental results are analyzed and compared to evaluate their performances under different operating conditions. The results indicate that the Type HT-CA tape can withstand 50 Hz short-circuit current impact with the amplitude of 1108 A (10 times of critical current Ic ) for 100 ms at 90 K, and its resistance is the smallest of the three tested samples under similar current impacts. Therefore, the Type HT-CA Bi-2223 tape is the optimal superconductor of the HTS power cable in the hybrid energy transmission pipeline.
文摘The influence of the cathode work function,carriers mobilities and temperature on the short-circuit current of single layer organic solar cells with Schottkey contacts was numerically studied,and the quantitative dependences of the short-circuit current on these quantities were obtained.The results provide the theoretical foundation for experimental study of single layer organic solar cells with Schottkey contacts.
基金Supported by Medical and public health technology research and development projects of Wu Xi science and technology development fund,No.CSE31N1501
文摘AIM To investigate the pharmacological effect of Tong XieYao Fang(TXYF) formula, a Chinese herbal formula, on Diarrhea-predominant irritable bowel syndrome(D-IBS) rats.METHODS In a neonatal maternal separation plus restraint stress(NMS + RS) model of D-IBS, male Sprague Dawley rats were randomly divided into two groups(NMS + RS group and TXYF-formula group) with no handlings were used as controls(NH group). Starting from postnatalday 60, rats in TXYF-formula group were administered TXYF-formula(4.92 g/100 g bodyweight) orally twice a day for 14 consecutive days while NH group and NMS + RS group were given distilled water. Using short-circuit current technology, we observed 5-HT-induced changes of current across ion channels, such as cystic fibrosis transmembrane conductance regulator(CFTR) Clchannel, epithelial Na+ channel(ENaC), Ca2+-dependent Cl- channel(CACC), Na+-K+-2Cl- co-transporter(NKCC), and Na+-HCO-3 co-transporter(NBC), in the colonic epithelium of three groups after exposure to drugs and specific blockers with a Power Lab System(AD Instruments International).RESULTS Under basal conditions, the changes of short-circuit current(?Isc, μA/cm2) induced by 5-HT were similar in NH group and TXYF-formula group, and both higher than NMS + RS group(70.86 μA/cm2 ± 12.32 μA/cm2, 67.67 μA/cm2 ± 11.68 μA/cm2 vs 38.8 μA/cm2 ± 7.25 μA/cm2, P < 0.01, respectively). When CACC was blocked by 4,4′-diisothiocyanato-stilbene-2,2′-disulfonic acid, 5-HT-induced ?Isc was smaller in NMS + RS group than in NH group and TXYF-formula group, respectively(48.41 μA/cm2 ± 13.15 μA/cm2 vs 74.62 μA/cm2 ± 10.73 μA/cm2, 69.22 μA/cm2 ± 11.7 μA/cm2, P < 0.05, respectively). The similar result could be obtained when ENaC was blocked by Amiloride(44.69 μA/cm2 ± 12.58 μA/cm2 vs 62.05 μA/cm2 ± 11.26 μA/cm2, 62.11 μA/cm2 ± 12.01 μA/cm2, P < 0.05, respectively). However, when CFTR Cl- channel was blocked by 1,1-dimethyl piperidinium chloride(DPC), 5-HT-induced ?Isc did not significantly differ in three groups(42.28 μA/cm2 ± 10.61 μA/cm2 vs 51.48 μA/cm2 ± 6.56 μA/cm2 vs 47.75 μA/cm2 ± 7.99 μA/cm2, P > 0.05, respectively). The similar results could also be obtained in three groups when NBC and NKCC were respectively blocked by their blockers.CONCLUSION TXYF-formula can regulate the Cl- and HCO-3 secretion of colonic mucosa via CFTR Cl- channel, Cl-/HCO-3 exchanger, NBC and NKCC co-transporters.
基金Project supported by the Jiangxi Provincial Key Research and Development Foundation,China(Grant No.2016BBH80043)the Open Fund of Jiangsu Key Laboratory of Materials and Technology for Energy Conversion,China(Grant No.NJ20160032)the National Natural Science Foundation of China(Grant Nos.61741404,61464007,and 51561022)
文摘A novel structure of Ag gridlSiN_(x)/n+-c-Si/n-c-Si/i-a-Si:H/p^(+)-a-Si:HlTCO/Ag grid was designed to increase the ef-ficiency of bifacial amorphous/crystalline silicon-based solar cells and reduce the rear material consumption and production cost.The simulation results show that the new structure obtains higher efficiency compared with the typical bifa-cial amorphous/crystalline silicon-based solar cell because of an increase in the short-circuit current(J_(sc)),while retaining the advantages of a high open-circuit voltage,low temperature coefficient,and good weak-light performance.Moreover,real cells composed of the novel structure with dimensions of 75 mm×75 mm were fabricated by a special fabrication recipe based on industrial processes.Without parameter optimization,the cell efficiency reached 21.1%with the J_(sc)of 41.7 mA/cm^(2).In addition,the novel structure attained 28.55%potential conversion efficiency under an illumination of AM 1.5 G,100 mW/cm^(2).We conclude that the configuration of the Ag grid/SiN_(x)/n^(+)-c-Si/n-c-Si/i-a-Si:H/p^(+)-a-Si:H/TCO/Ag grid is a promising structure for high efficiency and low cost.
文摘Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to increase additional equipment investments. Fast power electronics controlled flexible AC transmission system(FACTS)devices have opened a new way for suppressing the fault current levels, while maintaining their normal functionalities for steady-state and transient power system operation and control. Thyristor controlled phase shifting transformer(TCPST) is a beneficial FACTS device in modern power systems, which is capable of regulating regional powerflow. The mathematical model for TCPST under different operation modes is firstly investigated in this study. Intuitively, the phase shifting angle control can adjust the equivalent impedance of TCPST, but the effect has been demonstrated to be weak. Therefore, a novel transformer excitation impedance switching(EIS) control method, is proposed for fault current suppressing, according to the impedance characteristics of TCPST. Simulation results on IEEE 14-bus system have shown considerable current limiting characteristic of the EIS control under various fault types. Also, analysis of the timing requirement during fault interruption, overvoltage phenomenon, and ancillary mechanical support issues during EIS control is discussed,so as to implement the proposed EIS control properly for fast fault current suppression.
文摘A data acquisition system based on LabVIEW is designed and implemented, and electro-discharge(ED) fine truing of metal-bonded fine-grain diamond wheel based on real-time monitoring is researched. Real-time monitoring not only makes efficient impulse specification of ED truing easily obtained, but also is good for timely identifying no-load, avoiding short circuit and arc discharge phenomena and then for obtaining normal machining state. ED fine truing of the fine-grain wheel includes two steps: rough truing for high efficiency and fine truing for high precision. Final ED truing precision and efficiency not only depend on electric process specification, but also is concerned with electrode shape, insulated performance of operating fluid and vertical feed quantity value and frequency. Experiments indicate that ED fine truing based on real-time monitoring can improve the truing precision and efficiency. Average machining efficiency of W10 wheel is about 0.95 μm/min; the final run-out by ED truing is less than 2 μm.
基金supported in part by the National Natural Science Foundation of China under Grant 51307045in part by the Natural Science Foundation of Heilongjiang Province of China under Grant LH2019E075in part by the Fundamental Research Funds for the Heilongjiang Province Universities under Grant KJCX201915。
文摘The d-axis inductance(Ld)of the negative-salient permanent magnet synchronous motor(NSPMSM)is larger than the q-axis inductance(Lq).Compared with the traditional motor,the NSPMSM has the characteristics of a high overload capacity,wide speed range,and preventing permanent magnet demagnetization.Positive d-axis current(id)is applied to control positive reluctance torque when running at base speed.When the motor is running at high speed,a relatively small id can achieve speed expansion and effectively expand the motor flux-weakening range.The use of a magnetic bridge to increase the Ld and a W-type permanent magnet to reduce the Lq is proposed in this article as a novel NSPMSM rotor structure.Firstly,the working principle of the NSPMSM was determined according to the equivalent magnetic circuit.Secondly,using the finite element method,the influence of motor structure on torque and speed performance of NSPMSM was analyzed,and the motor structure was optimized.Thirdly,the effect of the internal power factor angle on the performance of the two motors is analyzed.Finally,the short circuit simulation and analysis verified that the NSPMSM has a stronger short circuit current suppression ability without sacrificing overload ability.