The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination o...The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss.展开更多
On the basis of a three-dimensional weakly nonliear theory of Lagrangian residual current in the Baroclinic shallow seas, a diagnostic numerical calculation of wind-driven, thermohaline and tide-induced Lagrangian res...On the basis of a three-dimensional weakly nonliear theory of Lagrangian residual current in the Baroclinic shallow seas, a diagnostic numerical calculation of wind-driven, thermohaline and tide-induced Lagrangian residual current in the Bohai Sea is made. The model involves the Richardson number in the eddy viscosity coefficient, wind, thcrmolialine and tidal effects in the focing terms. The runoff of the Huanghe River and a part of the Huanghai Warm Water coming from the Huanghai Sea through the Bohai Sea Strait is also considered. The velocity-splitting method is adopted. The wind-driven circu lation, thermohaline circulation and the tide-induced Lagrangian residual circulation are also obtained individually and analysed. The dynamics of the three main eddies in the Lagrangian mean circulation is discussed. Finally, the numerical result is partly verified with the observed data.展开更多
A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especia...A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especially for the sample of low conductivity. Based on METCE, we deduce a more efficient reconstruction algorithm of a 3D transient eddy current field. The computational burden is greatly reduced through the new algorithm, and the computational efficiency is improved. This new algorithm decompounds the space-time variables into two individual variables. The idea is to solve the spatial vector component firstly, and then multiply it by the corresponded time component. The iterative methods based on METCE are introduced to recover the distribution of conductivity in magneto-acoustic tomography. The reconstructed images of conductivity are consistent with the original distribution, which validate the new method.展开更多
When using the ATP-EMTP software to simulate the electromagnetic transient of local line or nearby line for a large area power grid, it is necessary to divide the area grid into internal network and external network s...When using the ATP-EMTP software to simulate the electromagnetic transient of local line or nearby line for a large area power grid, it is necessary to divide the area grid into internal network and external network so as to make the external network simple for the restriction of the simulation calculation scale of software. Based on the existing equivalence method, in this paper we proposed a practical equivalent method using the short-circuit calculation program of PSASP. In this way, we completed the equivalence of northwest power grid operating at the large mode of summer 2016. By comparing the power flow and the characteristics of short-circuit in the system before and after the equivalence, this equivalent method is proved to be correct.展开更多
-Drift current induced by wind and waves is investigated with phase-averaged Navier-Stokes equation in which the Reynolds stress is closed by k-ε model. The governing equations are solved by the finite volume method ...-Drift current induced by wind and waves is investigated with phase-averaged Navier-Stokes equation in which the Reynolds stress is closed by k-ε model. The governing equations are solved by the finite volume method in a system of nonorthogonal coordinates which is fitted to the phase-averaged wave surface. The predicted drift current is fairly reasonable and the drag coefficient of sea-surface predicted with the newly developed interface conditions shows good agreement with previous measurements when breaking waves do not exist.展开更多
System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system thr...System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system through a three-phase interleaved DC/DCconverter, the fuse and disconnector switch combination are used as the protection device, and the short-circuit point is set betweeneach branch and the DC distribution board, performing short-circuit simulation. This paper also proposes a short-circuit calculationmethod for super-capacitors based on the simplified model of series RC (Resistors & Capacitors), and verifies its correctness throughsimulation data. The results show that the introduction of a three-phase interleaved DC/DC converter reduces the current ripple andmakes the system control more convenient;short-circuit calculation and simulation have determined the short-circuit withstandcapability of the DC distribution board, and verified the feasibility of the fuse selection method and the short-circuit calculation methodof the super-capacitor. This provides reliable verification for the application and calculation of the actual project.展开更多
Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten th...Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten the safety of the microgrid. Therefore, it is imperative to conduct a comprehensive fault analysis of the inverter to guide the design of protection schemes. However, due to the complexity of droop control strategy, existing literatures have simplified asymmetric fault analysis of droop-controlled inverters to varying degrees. Therefore, accurate fault analysis of a droop-controlled inverter is needed. In this paper, by analyzing the control system, an accurate fault model is established. Based on this, a calculation method for instantaneous asymmetrical fault current is proposed. In addition, the current components and current characteristics are analyzed. It was determined that fault currents are affected by control loops, fault types, fault distance and nonlinear limiters. In particular, the influences of limiters on the fault model, fault current calculation and fault current characteristics were analyzed. Through detailed analysis, it was found that dynamics of the control loop cannot be ignored, the fault type and fault distance determine fault current level, and part of the limiters will totally change the fault current trend. Finally, calculation and experimental results verify the correctness of the proposed method.展开更多
A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power ca...A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power cable and outer liquefied natural gas (LNG) pipeline. The flowing LNG could maintain the operating temperature of the inner HTS power cable within the range of 85 K-90 K, thus the Bi-2223 superconductors in the HTS power cable produce little Joule loss with the transmission current below the critical current. Owing to the advantages of high power density, low transmission losses and economical manufacturing costs, the hybrid energy transmission pipeline is expected to be widely utilized in the near future. In order to ensure the safety of the HTS power cable and explosive LNG in case of short-circuit faults, this paper tests and analyzes the characteristics of Bi-2223 HTS tapes of the Type HT-CA, Type HT-SS and Type H models under short-circuit current impacts at the LNG cooling temperature (85 K-90 K). An experimental platform is designed and established for the ampacity tests of HTS tapes above LN2 cooling temperature (77 K). The AC over-current impact tests at 85 K-90 K are carried out on each sample of Bi-2223 tapes respectively, and the experimental results are analyzed and compared to evaluate their performances under different operating conditions. The results indicate that the Type HT-CA tape can withstand 50 Hz short-circuit current impact with the amplitude of 1108 A (10 times of critical current Ic ) for 100 ms at 90 K, and its resistance is the smallest of the three tested samples under similar current impacts. Therefore, the Type HT-CA Bi-2223 tape is the optimal superconductor of the HTS power cable in the hybrid energy transmission pipeline.展开更多
已有限流器优化配置方法大多以电阻、电感型限流器为配置对象,且只考虑每条线路均配置限流器的工况,降低系统经济效益,因此提出一种计及新型柔性直流限流器(novel flexible fault current limiter,NFFCL)运行特性、位置、数量等因素的...已有限流器优化配置方法大多以电阻、电感型限流器为配置对象,且只考虑每条线路均配置限流器的工况,降低系统经济效益,因此提出一种计及新型柔性直流限流器(novel flexible fault current limiter,NFFCL)运行特性、位置、数量等因素的优化配置方法。首先基于换流站和NFFCL简化模型,构建含NFFCL直流系统故障电流计算模型,并在5节点直流系统验证其准确性;其次,以NFFCL成本、限流效果为目标函数,以断路器最大开断电流为约束条件,构建多目标优化配置模型,并对NSGA-Ⅱ算法中的拥挤度计算进行改进,以实现优化配置过程中NFFCL安装数量与容量的解耦;最后,采用改进拥挤度计算的NSGA-Ⅱ算法求解得到11节点直流系统的NFFCL优化配置方案,并通过限流器成本、安装数量、限流效果之间的关系选取最终方案。展开更多
文摘The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss.
基金Project supported by the National Natural Science Foundation of China
文摘On the basis of a three-dimensional weakly nonliear theory of Lagrangian residual current in the Baroclinic shallow seas, a diagnostic numerical calculation of wind-driven, thermohaline and tide-induced Lagrangian residual current in the Bohai Sea is made. The model involves the Richardson number in the eddy viscosity coefficient, wind, thcrmolialine and tidal effects in the focing terms. The runoff of the Huanghe River and a part of the Huanghai Warm Water coming from the Huanghai Sea through the Bohai Sea Strait is also considered. The velocity-splitting method is adopted. The wind-driven circu lation, thermohaline circulation and the tide-induced Lagrangian residual circulation are also obtained individually and analysed. The dynamics of the three main eddies in the Lagrangian mean circulation is discussed. Finally, the numerical result is partly verified with the observed data.
基金Supported by the National Natural Science Foundation of China under Grant Nos 51137004,61427806 and 51577184the Equipment Development Project of Chinese Academy of Sciences under Grant No YZ201507
文摘A new method of 3D transient eddy current field calculation is proposed. The Maxwell equations with time component elimination (METCE) are derived under the assumption of magnetic quasi static approximation, especially for the sample of low conductivity. Based on METCE, we deduce a more efficient reconstruction algorithm of a 3D transient eddy current field. The computational burden is greatly reduced through the new algorithm, and the computational efficiency is improved. This new algorithm decompounds the space-time variables into two individual variables. The idea is to solve the spatial vector component firstly, and then multiply it by the corresponded time component. The iterative methods based on METCE are introduced to recover the distribution of conductivity in magneto-acoustic tomography. The reconstructed images of conductivity are consistent with the original distribution, which validate the new method.
文摘When using the ATP-EMTP software to simulate the electromagnetic transient of local line or nearby line for a large area power grid, it is necessary to divide the area grid into internal network and external network so as to make the external network simple for the restriction of the simulation calculation scale of software. Based on the existing equivalence method, in this paper we proposed a practical equivalent method using the short-circuit calculation program of PSASP. In this way, we completed the equivalence of northwest power grid operating at the large mode of summer 2016. By comparing the power flow and the characteristics of short-circuit in the system before and after the equivalence, this equivalent method is proved to be correct.
文摘-Drift current induced by wind and waves is investigated with phase-averaged Navier-Stokes equation in which the Reynolds stress is closed by k-ε model. The governing equations are solved by the finite volume method in a system of nonorthogonal coordinates which is fitted to the phase-averaged wave surface. The predicted drift current is fairly reasonable and the drag coefficient of sea-surface predicted with the newly developed interface conditions shows good agreement with previous measurements when breaking waves do not exist.
文摘System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system through a three-phase interleaved DC/DCconverter, the fuse and disconnector switch combination are used as the protection device, and the short-circuit point is set betweeneach branch and the DC distribution board, performing short-circuit simulation. This paper also proposes a short-circuit calculationmethod for super-capacitors based on the simplified model of series RC (Resistors & Capacitors), and verifies its correctness throughsimulation data. The results show that the introduction of a three-phase interleaved DC/DC converter reduces the current ripple andmakes the system control more convenient;short-circuit calculation and simulation have determined the short-circuit withstandcapability of the DC distribution board, and verified the feasibility of the fuse selection method and the short-circuit calculation methodof the super-capacitor. This provides reliable verification for the application and calculation of the actual project.
基金supported by National Natural Science Foundation of China under Grant 51977066。
文摘Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten the safety of the microgrid. Therefore, it is imperative to conduct a comprehensive fault analysis of the inverter to guide the design of protection schemes. However, due to the complexity of droop control strategy, existing literatures have simplified asymmetric fault analysis of droop-controlled inverters to varying degrees. Therefore, accurate fault analysis of a droop-controlled inverter is needed. In this paper, by analyzing the control system, an accurate fault model is established. Based on this, a calculation method for instantaneous asymmetrical fault current is proposed. In addition, the current components and current characteristics are analyzed. It was determined that fault currents are affected by control loops, fault types, fault distance and nonlinear limiters. In particular, the influences of limiters on the fault model, fault current calculation and fault current characteristics were analyzed. Through detailed analysis, it was found that dynamics of the control loop cannot be ignored, the fault type and fault distance determine fault current level, and part of the limiters will totally change the fault current trend. Finally, calculation and experimental results verify the correctness of the proposed method.
基金supported by National Key R&D Project under Grant(2018YFB0904400).
文摘A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power cable and outer liquefied natural gas (LNG) pipeline. The flowing LNG could maintain the operating temperature of the inner HTS power cable within the range of 85 K-90 K, thus the Bi-2223 superconductors in the HTS power cable produce little Joule loss with the transmission current below the critical current. Owing to the advantages of high power density, low transmission losses and economical manufacturing costs, the hybrid energy transmission pipeline is expected to be widely utilized in the near future. In order to ensure the safety of the HTS power cable and explosive LNG in case of short-circuit faults, this paper tests and analyzes the characteristics of Bi-2223 HTS tapes of the Type HT-CA, Type HT-SS and Type H models under short-circuit current impacts at the LNG cooling temperature (85 K-90 K). An experimental platform is designed and established for the ampacity tests of HTS tapes above LN2 cooling temperature (77 K). The AC over-current impact tests at 85 K-90 K are carried out on each sample of Bi-2223 tapes respectively, and the experimental results are analyzed and compared to evaluate their performances under different operating conditions. The results indicate that the Type HT-CA tape can withstand 50 Hz short-circuit current impact with the amplitude of 1108 A (10 times of critical current Ic ) for 100 ms at 90 K, and its resistance is the smallest of the three tested samples under similar current impacts. Therefore, the Type HT-CA Bi-2223 tape is the optimal superconductor of the HTS power cable in the hybrid energy transmission pipeline.
文摘已有限流器优化配置方法大多以电阻、电感型限流器为配置对象,且只考虑每条线路均配置限流器的工况,降低系统经济效益,因此提出一种计及新型柔性直流限流器(novel flexible fault current limiter,NFFCL)运行特性、位置、数量等因素的优化配置方法。首先基于换流站和NFFCL简化模型,构建含NFFCL直流系统故障电流计算模型,并在5节点直流系统验证其准确性;其次,以NFFCL成本、限流效果为目标函数,以断路器最大开断电流为约束条件,构建多目标优化配置模型,并对NSGA-Ⅱ算法中的拥挤度计算进行改进,以实现优化配置过程中NFFCL安装数量与容量的解耦;最后,采用改进拥挤度计算的NSGA-Ⅱ算法求解得到11节点直流系统的NFFCL优化配置方案,并通过限流器成本、安装数量、限流效果之间的关系选取最终方案。