The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground...The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.展开更多
Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A ...Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A closed-form expression of the induced voltage caused by the short-circuit fault of the ultra-high voltage power (UHVAC) transmission line is given. The transmission line model of the buried pipeline is set up and a set of formulas for calculating induced voltage on the pipeline and the parameters of the buried pipeline in actual environment condition are given. At last, the characteristic of the harm^hl effects on the buried pipeline from the power line short-circuit fault are discussed.展开更多
基金This paper is supported in part by the National Natural Science Foundations of China,and the Major Science and Technology Projects in Yunnan Province under Grant Nos.51667010,51807085,and 202002AF080001.
文摘The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.
基金supported by the National Natural Science Foundation of China(60671055,61171051)the Doctorate Foundation of the Ministry of Education of China(200700130046)
文摘Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A closed-form expression of the induced voltage caused by the short-circuit fault of the ultra-high voltage power (UHVAC) transmission line is given. The transmission line model of the buried pipeline is set up and a set of formulas for calculating induced voltage on the pipeline and the parameters of the buried pipeline in actual environment condition are given. At last, the characteristic of the harm^hl effects on the buried pipeline from the power line short-circuit fault are discussed.