期刊文献+
共找到8,873篇文章
< 1 2 250 >
每页显示 20 50 100
Effects of virtual agents on interaction efficiency and environmental immersion in MR environments
1
作者 Yihua BAO Jie GUO +2 位作者 Dongdong WENG Yue LIU Zeyu TIAN 《虚拟现实与智能硬件(中英文)》 EI 2024年第2期169-179,共11页
Background Physical entity interactions in mixed reality(MR)environments aim to harness human capabilities in manipulating physical objects,thereby enhancing virtual environment(VEs)functionality.In MR,a common strate... Background Physical entity interactions in mixed reality(MR)environments aim to harness human capabilities in manipulating physical objects,thereby enhancing virtual environment(VEs)functionality.In MR,a common strategy is to use virtual agents as substitutes for physical entities,balancing interaction efficiency with environmental immersion.However,the impact of virtual agent size and form on interaction performance remains unclear.Methods Two experiments were conducted to explore how virtual agent size and form affect interaction performance,immersion,and preference in MR environments.The first experiment assessed five virtual agent sizes(25%,50%,75%,100%,and 125%of physical size).The second experiment tested four types of frames(no frame,consistent frame,half frame,and surrounding frame)across all agent sizes.Participants,utilizing a head mounted display,performed tasks involving moving cups,typing words,and using a mouse.They completed questionnaires assessing aspects such as the virtual environment effects,interaction effects,collision concerns,and preferences.Results Results from the first experiment revealed that agents matching physical object size produced the best overall performance.The second experiment demonstrated that consistent framing notably enhances interaction accuracy and speed but reduces immersion.To balance efficiency and immersion,frameless agents matching physical object sizes were deemed optimal.Conclusions Virtual agents matching physical entity sizes enhance user experience and interaction performance.Conversely,familiar frames from 2D interfaces detrimentally affect interaction and immersion in virtual spaces.This study provides valuable insights for the future development of MR systems. 展开更多
关键词 Mixed reality Virtual agents Interaction performance Environmental immersion Virtual environments
下载PDF
Isometric Immersions of Lightlike Warped Product Manifolds
2
作者 Domitien Ndayirukiye Cyriaque Atindogbe Gilbert Nibaruta 《Journal of Applied Mathematics and Physics》 2024年第7期2490-2505,共16页
In this paper, we deal with isommetric immersions of globally null warped product manifolds into Lorentzian manifolds with constant curvature c in codimension k≥3. Under the assumptions that the globally null warped ... In this paper, we deal with isommetric immersions of globally null warped product manifolds into Lorentzian manifolds with constant curvature c in codimension k≥3. Under the assumptions that the globally null warped product manifold has no points with the same constant sectional curvature c as the Lorentzian ambient, we show that such isometric immersion splits into warped product of isometric immersions. 展开更多
关键词 Lightlike Warped Product Manifolds Globally Null Warped Products Manifolds Lightlike Warped Product Isometric immersions
下载PDF
Improving resolution of superlens based on solid immersion mechanism 被引量:1
3
作者 郝占磊 周杨阳 +2 位作者 吴贝 刘益能 陈焕阳 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第6期21-26,共6页
Super-resolution imaging with superlens has been one of the fundamental research topics. Unfortunately, the resolution of superlens is inevitably restrained by material loss. To address the problem, we introduce the s... Super-resolution imaging with superlens has been one of the fundamental research topics. Unfortunately, the resolution of superlens is inevitably restrained by material loss. To address the problem, we introduce the solid immersion mechanism into the slab superlens and the cylindrical superlens. The proposed solid immersion slab superlens(SISSL) and the solid immersion cylindrical superlens(SICSL) can improve the resolution by converting evanescent wave to propagating wave using high refractive index materials. From the perspective of applications, the cylindrical superlens with finite cross section and the ability of magnification or demagnification has more advantages than the slab superlens. Therefore,we focus on demonstrating analytically the super-resolution imaging of SICSL. Due to the impedance mismatching caused by solid immersion mechanism, the whispering gallery modes(WGMs) are excited between SICSL and the air interface.We clarify the excitation conditions of WGMs and analyze their influence on the imaging quality of SICSL. The SISSL and SICSL may pave a way to apply in lithography technique and real-time biomolecular imaging in future. 展开更多
关键词 super-resolution imaging material loss solid immersion cylindrical superlens whispering gallery modes
下载PDF
Spatial and Temporal Distribution of Different Grades of Short-time Precipitation in Xining City
4
作者 Liang XU Yongling SU 《Meteorological and Environmental Research》 CAS 2023年第1期21-23,共3页
Based on the hourly precipitation data from 4 observation stations of Xining City from June to September during 2005-2011,the temporal and spatial distribution characteristics of short-time precipitation were analyzed... Based on the hourly precipitation data from 4 observation stations of Xining City from June to September during 2005-2011,the temporal and spatial distribution characteristics of short-time precipitation were analyzed.The results show that the precipitation distribution in Xining region exhibited the less-more-less trend from southwest to northeast,while the torrential rain gradually increased from the northwest and southwest to the middle.The hourly general precipitation in Xining region had obviously seasonal characteristics,and its annual distribution showed wavy changes,but the annual variation of short-time heavy precipitation and rainstorm was very obvious.Furthermore,short-time heavy precipitation was concentrated from 18:00 to 24:00,followed by 03:00-07:00 on the following day.The occurrence time of short-time rainstorm accorded with short-time heavy precipitation.It offers a useful reference for the accurate and timely short-term forecast. 展开更多
关键词 DIFFERENT GRADES short-time PRECIPITATION Temporal-spatial DISTRIBUTION
下载PDF
Application of immersion B-scan ultrasonography in diagnosis of complex retinal detachment,persistent hyperplastic primary vitreous and intraocular tumors
5
作者 Qing-Hua Yang An-Qi Liu +5 位作者 Ying-Xin Qu Hong-Tao Zhang Bing Chen Yan Li Liang Jia Li-Qiang Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期388-395,共8页
AIM:To evaluate the diagnostic value of panoramic immersion B-scan ultrasonography(Pano-immersion B-scan,PIB)in complex retinal detachment(RD),persistent hyperplastic primary vitreous(PHPV)and intraocular tumors.METHO... AIM:To evaluate the diagnostic value of panoramic immersion B-scan ultrasonography(Pano-immersion B-scan,PIB)in complex retinal detachment(RD),persistent hyperplastic primary vitreous(PHPV)and intraocular tumors.METHODS:The clinical data of 44 patients collected from May 2012 to December 2019 in Chinese PLA General Hospital was retrospectively studied.All of these patients underwent PIB of the eye,because it was difficult to diagnose by routine ocular fundus examination,conventional ultrasound or/and ultrasonic biomicroscope(UBM)due to opacity of refractive media,pupillary occlusion,large involvement or special location of the lesion.The imaging features of difficult cases in PIB were analyzed.The diagnosis accuracy rating of PIB were evaluated and contrasted with conventional ultrasound or UBM by the standard of intraoperative diagnosis or/and pathological results.RESULTS:According to intraoperative diagnosis or pathological results as gold standard,among the 44 cases,there were 19 cases missed diagnosis,misdiagnosed or difficult-to-diagnose by conventional ultrasound or UBM,including 4 cases of long-standing RD difficult to diagnose,4 cases misdiagnosed,and 11 cases incompletely observed or miss diagnosed.The diagnostic accuracy rate of PIB and conventional ultrasound or UBM were 100%(44/44)and 56.82%(25/44),and the sensitivity of them were 100%and 56.82%.All the patients underwent PIB and were diagnosed as RD(15 cases),retinal and choroidal detachment(4 cases),subchoroidal hematocele(1 case),vitreous opacity and/or organic membrane formation(4 cases),PHPV(12 cases),iris and/or ciliary body tumors(3 cases),and choroidal tumors(6 cases).According to the intraoperative diagnosis or pathological results,the diagnostic coincidence rate of PIB was 100%,which was significantly higher than conventional ultrasound and UBM.CONCLUSION:PIB can help to accurately diagnose complex RD,PHPV,and intraocular masses with special location or/and excessive size.It has important diagnostic value for patients with equivocal findings at conventional ultrasound examination. 展开更多
关键词 immersion ULTRASONOGRAPHY PANORAMIC retinal detachment persistent hyperplastic primary vitreous intraocular tumor
下载PDF
Study of Immersion in Augmented Reality Through Analysis of Immersion Elements in Museums
6
作者 Xiaofan Zhang 《Journal of Contemporary Educational Research》 2023年第8期112-118,共7页
With the advent of the information age,augmented reality technology can enhance the sense of reality in the virtual world and immerse people in the real and virtual world.People have always been interested in virtual ... With the advent of the information age,augmented reality technology can enhance the sense of reality in the virtual world and immerse people in the real and virtual world.People have always been interested in virtual space or augmented reality technology,especially in the face of historical development trends.Museums have always been open to the public,they are not just a collection,but also an exhibition for the public.Through analyzing different museums,it is found that museums with augmented reality technology exhibitions are non-profit museums for the purpose of emotional experience.In order to find out the immersion factors of virtual reality in museums,on the basis of previous research,this paper divides immersion in augmented reality into story immersion,five-sense experience immersion,and spatial interaction immersion.Through the analysis of different museums,it is found that immersion through five-sense experience is the most commonly used method when all display media are included.This method provides educational content for museum visitors and projects virtual presentations through monitors and portable IT devices,thereby increasing visitors’viewing pleasure. 展开更多
关键词 EXHIBITION MUSEUMS immersive experience Augmented reality
下载PDF
Comparative Analysis of ARIMA and LSTM Model-Based Anomaly Detection for Unannotated Structural Health Monitoring Data in an Immersed Tunnel
7
作者 Qing Ai Hao Tian +4 位作者 Hui Wang Qing Lang Xingchun Huang Xinghong Jiang Qiang Jing 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1797-1827,共31页
Structural Health Monitoring(SHM)systems have become a crucial tool for the operational management of long tunnels.For immersed tunnels exposed to both traffic loads and the effects of the marine environment,efficient... Structural Health Monitoring(SHM)systems have become a crucial tool for the operational management of long tunnels.For immersed tunnels exposed to both traffic loads and the effects of the marine environment,efficiently identifying abnormal conditions from the extensive unannotated SHM data presents a significant challenge.This study proposed amodel-based approach for anomaly detection and conducted validation and comparative analysis of two distinct temporal predictive models using SHM data from a real immersed tunnel.Firstly,a dynamic predictive model-based anomaly detectionmethod is proposed,which utilizes a rolling time window for modeling to achieve dynamic prediction.Leveraging the assumption of temporal data similarity,an interval prediction value deviation was employed to determine the abnormality of the data.Subsequently,dynamic predictive models were constructed based on the Autoregressive Integrated Moving Average(ARIMA)and Long Short-Term Memory(LSTM)models.The hyperparameters of these models were optimized and selected using monitoring data from the immersed tunnel,yielding viable static and dynamic predictive models.Finally,the models were applied within the same segment of SHM data,to validate the effectiveness of the anomaly detection approach based on dynamic predictive modeling.A detailed comparative analysis discusses the discrepancies in temporal anomaly detection between the ARIMA-and LSTM-based models.The results demonstrated that the dynamic predictive modelbased anomaly detection approach was effective for dealing with unannotated SHM data.In a comparison between ARIMA and LSTM,it was found that ARIMA demonstrated higher modeling efficiency,rendering it suitable for short-term predictions.In contrast,the LSTM model exhibited greater capacity to capture long-term performance trends and enhanced early warning capabilities,thereby resulting in superior overall performance. 展开更多
关键词 Anomaly detection dynamic predictive model structural health monitoring immersed tunnel LSTM ARIMA
下载PDF
Application of Immersive Media Technology in Ideological and Political Theory Courses Instruction at Shandong Vocational Colleges
8
作者 Guoqing Liu Tingting Guo Ohamariah Samu 《Journal of Contemporary Educational Research》 2024年第5期187-193,共7页
This paper describes how virtual classrooms and out-of-classroom instruction can be used to help students in ideological and political theory courses strengthen their identities and improve the efficiency of their ass... This paper describes how virtual classrooms and out-of-classroom instruction can be used to help students in ideological and political theory courses strengthen their identities and improve the efficiency of their assignments.By using immersive media technology,the course is turned into a form of entertainment,enriched with content,and combined with methods such as digital video editing and manipulation to meet the needs of students in university ideological and political theory courses.Virtual reality technology can create realistic virtual environments created by computers,enabling students to perceive and manipulate a variety of virtual objects,interact with them,and create a sense of immersion in the virtual environment.Research has shown the potential benefits of using immersive media technologies and augmented reality in education.The potential of virtual reality in education has been increasingly emphasized and has been widely researched and applied. 展开更多
关键词 immersive technology High school ideological and political program Virtual classroom Shandong education
下载PDF
从Immersion到Flow experience:“沉浸式传播”的再认识 被引量:91
9
作者 孔少华 《首都师范大学学报(社会科学版)》 CSSCI 北大核心 2019年第4期74-83,共10页
虚拟现实技术的进步使沉浸式传播成为新的研究焦点,“沉浸”对应着Immersion和Flow experience两个英文术语,术语混用体现着两种研究取向,也意味着一种新的研究趋势。图景构建带来的感官沉浸是沉浸传播的初级阶段,而基于各种媒介手段实... 虚拟现实技术的进步使沉浸式传播成为新的研究焦点,“沉浸”对应着Immersion和Flow experience两个英文术语,术语混用体现着两种研究取向,也意味着一种新的研究趋势。图景构建带来的感官沉浸是沉浸传播的初级阶段,而基于各种媒介手段实现的意识沉浸则是沉浸传播的发展方向,对沉浸问题的研究最终会在用户认知研究形成新的跨学科研究交点。媒介世界与真实世界之间的边界问题是沉浸式传播需要解决的关键问题,虚拟现实技术和注意力强化是消除边界的两大方式。艺术手法、拟像技术、综合互动、意义内爆是沉浸传播形成的前提,构建泛在网络、运用交互叙事手法、积极探索受众差异、合理地使用虚拟现实技术进行传播,是实现沉浸式传播的重要方法。 展开更多
关键词 沉浸式传播 沉浸式体验 虚拟现实 VR新闻 受众认知
下载PDF
Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes 被引量:9
10
作者 Qing-Hua Yang Bing Chen +2 位作者 Guang-Hua Peng Zhao-Hui Li Yi-Fei Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期441-445,共5页
AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHOD... AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan. 展开更多
关键词 axial length measurement immersion ULTRASONOGRAPHY high myopia
下载PDF
SLANT IMMERSIONS OF COMPLEX SPACE FORMS AND CHEN'S INEQUALITY 被引量:10
11
作者 李光汉 吴传喜 《Acta Mathematica Scientia》 SCIE CSCD 2005年第2期223-232,共10页
A submanifold in a complex space form is called slant if it has constant Wirtinger angles. B. Y. Chen and Y. Tazawa proved that there do not exist minimal proper slant surfaces in CP2 and CH2. So it seems that the sla... A submanifold in a complex space form is called slant if it has constant Wirtinger angles. B. Y. Chen and Y. Tazawa proved that there do not exist minimal proper slant surfaces in CP2 and CH2. So it seems that the slant immersion has some interesting properties. The authors have great interest to consider slant immersions satisfying some additional conditions, such as unfull first normal bundles or Chen’s equality holding. They prove that there do not exist n-dimensional Kaehlerian slant immersions in CPn and CHn with unfull first normal bundles. Next, it is seen that every Kaehlerian slant submanifold satisfying an equality of Chen is minimal which is similar to that of Lagrangian immersions. But in contrast, it is shown that a large class of slant immersions do not exist thoroughly. Finally, they give an application of Chen’s inequality to general slant immersions in a complex projective space, which generalizes a result of Chen. 展开更多
关键词 Slant immersion IDEAL Chen's inequality complex space form
下载PDF
ION HEATING PROCESS DURING PLASMA IMMERSION ION IMPLANTATION 被引量:11
12
作者 X.B. Tian, X.F. Wang, A.G. Liu, L.P. Wang, S. Y. Wang, B. Y. Tang and P. K. Chu 1)Advanced Welding Production & Technology National Key Laboratory, Harbin Institute of Technology, Harbin 150001, China 2)Department of Physics & Materials Science, City Uni 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第2期734-739,共6页
The research on plasma immersion ion implantation has been conducted for a little over ten years. Much is needed to investigate including processing technlogy, plasma sheath dynamics, interaction of plasma and surface... The research on plasma immersion ion implantation has been conducted for a little over ten years. Much is needed to investigate including processing technlogy, plasma sheath dynamics, interaction of plasma and surface, etc. Of the processing methods elavated temperature technique is usually used in PIII to produce a thick modified layer by means of the thermal diffusion. Meanwhile plasma ion heating is more recently developed by Ronghua Wei et al[1]. Therefore the temeperature is a critical parameter in plasma ion processing. In this paper we present the theoretical model and analysize the effect of imlantation voltage, plasma density, ion mass,etc on the temperature rise. 展开更多
关键词 plasma immersion ion implantation ion heating TEMPERATURE
下载PDF
Characterization of the Nanoscale Microstructure of an Immersion Silver on Sputtered Copper 被引量:6
13
作者 TANG Dian WEI Zhe-Liang +3 位作者 SHAO Yan-Qun YOU Shao-Xin O'KEEFE Mathew O' KEEFE Thomas 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 北大核心 2005年第8期935-939,共5页
Silver has grown its attraction of the scientists in microelectronic field recently.Electrochemical deposition of silver onto copper substrates by immersion method has been one of the keen topics. In this study, ethan... Silver has grown its attraction of the scientists in microelectronic field recently.Electrochemical deposition of silver onto copper substrates by immersion method has been one of the keen topics. In this study, ethanol was used as the plating solution in which some chemicals were added. The silver deposits were characterized by a field emission scanning electron microscopy (FESEM), an atom force microscope (AFM), a transmission electron microscope (TEM) and a selected area electron diffraction (SAED). It was found that silver immersion using ethanol-based bath has good coverage feature. The highlands of the copper substrate are coated by silver particles whose sizes are around 12 nm, but those sizes at low-lying lands are a little smaller. 展开更多
关键词 SILVER immersion COPPER NANOPARTICLES
下载PDF
Diagnostic and therapeutic applications of water-immersion colonoscopy 被引量:14
14
作者 Shinya Sugimoto Takeshi Mizukami 《World Journal of Gastroenterology》 SCIE CAS 2015年第21期6451-6459,共9页
Colonoscopy techniques combining or replacing air insufflation with water infusion are becoming increasinglypopular.They were originally designed to reduce colonic spasms,facilitate cecal intubation,and lower patient ... Colonoscopy techniques combining or replacing air insufflation with water infusion are becoming increasinglypopular.They were originally designed to reduce colonic spasms,facilitate cecal intubation,and lower patient discomfort and the need for sedation.These maneuvers straighten the rectosigmoid colon and enable the colonoscope to be inserted deeply without causing looping of the colon.Water-immersion colonoscopy minimizes colonic distension and improves visibility by introducing a small amount of water.In addition,since pain during colonoscopy indicates risk of bowel perforation and sedation masks this important warning,this method has the potential to be the favored insertion technique because it promotes patient safety without sedation.Recently,this water-immersion method has not only been used for colonoscope insertion,but has also been applied to therapy for sigmoid volvulus,removal of lesions,lower gastrointestinal bleeding,and therapeutic diagnosis of abnormal bowel morphology and irritable bowel syndrome.Although a larger sample size and prospective head-to-head-designed studies will be needed,this review focuses on the usefulness of waterimmersion colonoscopy for diagnostic and therapeutic applications. 展开更多
关键词 COLONOSCOPY WATER immersion Waterexchange Underwater Unsedated Sigmoid VOLVULUS Detorsion POLYPECTOMY Gastrointestinal bleeding IRRITABLE bowel syndrome
下载PDF
Motor Fault Diagnosis Based on Short-time Fourier Transform and Convolutional Neural Network 被引量:40
15
作者 Li-Hua Wang Xiao-Ping Zhao +2 位作者 Jia-Xin Wu Yang-Yang Xie Yong-Hong Zhang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第6期1357-1368,共12页
With the rapid development of mechanical equipment, the mechanical health monitoring field has entered the era of big data. However, the method of manual feature extraction has the disadvantages of low efficiency and ... With the rapid development of mechanical equipment, the mechanical health monitoring field has entered the era of big data. However, the method of manual feature extraction has the disadvantages of low efficiency and poor accuracy, when handling big data. In this study, the research object was the asynchronous motor in the drivetrain diagnostics simulator system. The vibration signals of different fault motors were collected. The raw signal was pretreated using short time Fourier transform (STFT) to obtain the corresponding time-frequency map. Then, the feature of the time-frequency map was adap- tively extracted by using a convolutional neural network (CNN). The effects of the pretreatment method, and the hyper parameters of network diagnostic accuracy, were investigated experimentally. The experimental results showed that the influence of the preprocessing method is small, and that the batch-size is the main factor affecting accuracy and training efficiency. By investigating feature visualization, it was shown that, in the case of big data, the extracted CNN features can represent complex mapping relationships between signal and health status, and can also overcome the prior knowledge and engineering experience requirement for feature extraction, which is used by tra- ditional diagnosis methods. This paper proposes a new method, based on STFT and CNN, which can complete motor fault diagnosis tasks more intelligently and accurately. 展开更多
关键词 Big data Deep learning short-time Fouriertransform Convolutional neural network MOTOR
下载PDF
Beneficial effects of a novel shark-skin collagen dressing for the promotion of seawater immersion wound healing 被引量:2
16
作者 Xian-Rong Shen Xiu-Li Chen +8 位作者 Hai-Xia Xie Ying He Wei Chen Qun Luo Wei-Hong Yuan Xue Tang Deng-Yong Hou Ding-Wen Jiang Qing-Rong Wang 《Military Medical Research》 SCIE CAS 2018年第2期117-128,共12页
Background: Wounded personnel who work at sea often encounter a plethora of difficulties. The most important of these difficulties is seawater immersion. Common medical dressings have little effect when the affected a... Background: Wounded personnel who work at sea often encounter a plethora of difficulties. The most important of these difficulties is seawater immersion. Common medical dressings have little effect when the affected area is immersed in seawater, and only rarely dressings have been reported for the treatment of seawater-immersed wounds. The objective of this study is to develop a new dressing which should be suitable to prevent the wound from seawater immersion and to promote the wound healing.Methods: Shark skin collagen(SSC) was purified via ethanol de-sugaring and de-pigmentation and adjusted for p H. A shark skin collagen sponge(SSCS) was prepared by freeze-drying. SSCS was attached to an anti-seawater immersion polyurethane(PU) film(SSCS+PU) to compose a new dressing. The biochemical properties of SSC and physicochemical properties of SSCS were assessed by standard methods. The effects of SSCS and SSCS+PU on the healing of seawaterimmersed wounds were studied using a seawater immersion rat model. For the detection of SSCS effects on seawaterimmersed wounds, 12 SD rats, with four wounds created in each rat, were divided into four groups: the 3 rd day group, 5 th day group, 7 th day group and 12 th day group. In each group, six wounds were treated with SSCS, three wounds treated with chitosan served as the positive control, and three wounds treated with gauze served as the negative control. For the detection of the SSCS+PU effects on seawater-immersed wounds, 36 SD rats were divided into three groups: the gauze(GZ)+PU group, chitosan(CS)+PU group and SSCS+PU group, with 12 rats in each group, and two wounds in each rat. The wound sizes were measured to calculate the healing rate, and histomorphology and the immunohistochemistry of the CD31 and TGF-β expression levels in the wounded tissues were measured by standard methods.Results: The results of Ultraviolet-visible(UV-vis) spectrum, Fourier-transform infrared(FTIR) spectrum, circular dichroism(CD) spectra, sodium dodecyl sulfate polyacrylamide gel electrophoresis(SDS-PAGE), and amino acid composition analyses of SSC demonstrated that SSC is type I collagen. SSCS had a homogeneous porous structure of approximately 200μm, porosity rate of 83.57%±2.64%, water vapor transmission ratio(WVTR) of 4500 g/m2, tensile strength of 1.79±0.41 N/mm, and elongation at break of 4.52%±0.01%. SSCS had significant beneficial effects on seawater-immersed wound healing. On the 3 rd day, the healing rates in the GZ negative control, CS positive control and SSCS rats were 13.94%±5.50%, 29.40%±1.10% and 47.24%±8.40%, respectively. SSCS also enhanced TGF-in the initial stage of the healing period. The SSCS+PU dressing effectively protected woundsβ and CD31 expression from seawater immersion for at least 4 h, and accelerated re-epithelialization, vascularization and granulation formation of seawater-immersed wounds in the earlier stages of wound healing, and as well as significantly promoted wound healing. The SSCS+PU dressing also enhanced expression of TGF-n and gauze dressings.β and CD31. The effects of SSCS and SSCS+PU were superior to those of both the chitosaConclusion: SSCS has significant positive effects on the promotion of seawater-immersed wound healing, and a SSCS+PU dressing effectively prevents seawater immersion, and significantly promotes seawater-immersed wound healing. 展开更多
关键词 Anti-seawater immersion DRESSING SHARK skin collagen Seawater immersion WOUND WOUND HEALING
下载PDF
TWO-DIMENSIONAL NUMERICAL ANALYSIS OF PLASMA IMMERSION ION IMPLANTATION OF CYLINDRICAL BORES 被引量:4
17
作者 A. G. Liu,X.F. Wang, L.P. Wang, S. Y. Wang, B. Y. Tang and P.K. Chu 1) Advanced Welding Production Technology National Key Laboratory, HIT, Harbin 150001, China 2) Department of Physics and Material Science, City University of Hong Kong, 83 Tat Chee Aven 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第2期740-745,共6页
Plasma immersion ion implantation (PIII), unrestricted by sight-light process, is considered a proper method for inner surface strengthening. Two-dimensional simulation oj inner surface PIII process of cylindrical bo... Plasma immersion ion implantation (PIII), unrestricted by sight-light process, is considered a proper method for inner surface strengthening. Two-dimensional simulation oj inner surface PIII process of cylindrical bores were carried out in this paper using cold plasma fluid model, and influence of the bore's dimension on impact energy, retained dose and uniformity of inner surface were investigated. 展开更多
关键词 plasma immersion ion implantation plasma sheath inner surface modification computer simulation
下载PDF
Microstructural evolution in Al–Zn–Mg–Cu–Sc–Zr alloys during short-time homogenization 被引量:6
18
作者 Tao Liu Chun-nian He +3 位作者 Gen Li Xin Meng Chun-sheng Shi Nai-qin Zhao 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2015年第5期516-523,共8页
Abstract: Microstructural evolution in a new kind of aluminum (A1) alloy with the chemical composition of AI-8.82Zn-2.08Mg- 0.80Cu-3.31Sc-0.3Zr was investigated. It is found that the secondary phase MgZn2 is comple... Abstract: Microstructural evolution in a new kind of aluminum (A1) alloy with the chemical composition of AI-8.82Zn-2.08Mg- 0.80Cu-3.31Sc-0.3Zr was investigated. It is found that the secondary phase MgZn2 is completely dissolved into the matrix during a short homogenization treatment (470℃, 1 h), while the primary phase A13(Sc,Zr) remains stable. This is due to Sc and Zr additions into the A1 al- loy, high Zn/Mg mass ratio, and low Cu content. The experimental findings fit well with the results calculated by the homogenization diffusion kinetics equation. The alloy shows an excellent mechanical performance after the short homogenization process followed by hot-extrusion and T6 treatment. Consequently, a good combination of low energy consumotion and favorable mechanical properties is obtained. 展开更多
关键词 aluminum alloys microstructural evolution short-time homogcnization grain refinement
下载PDF
Comparison of immersion ultrasound and low coherence reflectometry for ocular biometry in cataract patients 被引量:2
19
作者 Yan Li Hong-Xun Li +6 位作者 Yang-Chen Liu Ya-Tu Guo Jian-Min Gao Bin Wu Nan Zhang Dong Liu Xiao-Yong Yuan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第6期966-969,共4页
AIM: To compare the results of axial length (AL) biometry in cataract eyes by three methods: immersion B-ultrasound (IB) biometry, immersion A-ultrasound (IA) biometry and optical low coherence reflectometry. ... AIM: To compare the results of axial length (AL) biometry in cataract eyes by three methods: immersion B-ultrasound (IB) biometry, immersion A-ultrasound (IA) biometry and optical low coherence reflectometry. METHODS: In this prospective observational study of eyes with cataract AL measurements were performed using immersion ultrasound and optical low coherence reflectometry device. The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired t-test, and its correlation was evaluated by Pearson coefficient. RESULTS: Eighty eyes of 80 patients (39 men and 41 women) for cataract surgery were included in the study. The values of AL could be got from all 80 eyes by IB and IA, the difference of AL measurements between IA and IB was of no statistical significance (P=0.97); the mean difference in AL measurements was -0.031 mm (P=0.26; 95%CI, -0.09 to 0.02); linear regression showed an excellent correlation (r=0.98, P〈0.0001). Forty-five of eighty eyes with results of AL measurements, which can be obtained by three methods; the difference of AL measurements was of no statistical significance (IA vs IB, P=0.18; IA vs Lenstar, P=0.51; IB vs Lenstar, P=0.07); linear regression showed an excellent correlation (IA vs IB, r=0.99; IA vs Lenstar, r=0.96; IB vs Lenstar, r=0.96); Bland-Altman analysis also showed good agreement between the two methods [IA vs IB, 95% limits of agreement (LoA), -0.36 to 0.28 mm; IA vs Lenstar, 95% LoA, -0.65 to 0.69 mm; IB vs Lenstar, 95% LoA, -0.55 to 0.68 mm]. CONCLUSION: Measurements with the optical low coherence reflectometry correlated well with IB and IA. In the eyes with serious refractive medium opacity, the measurements of AL could not be achieved or existed deviations when using optical low coherence reflectometry device. Under such circumstances, we should choose IA or IB as the optimization method to obtain measurements, in order to get much more accurate results. 展开更多
关键词 ULTRASONOGRAPHY immersion axial length BIOMETRY
下载PDF
Research Progress in Solderable Black Pad of Electroless Nickel/Immersion Gold 被引量:2
20
作者 刘海萍 李宁 +1 位作者 毕四富 黎德育 《Journal of Rare Earths》 SCIE EI CAS CSCD 2007年第S2期308-312,共5页
Electroless nickel/immersion gold (ENIG) technology is widely used as one of the surface final finish for electronics packaging substrate and printed circuit board (PCB), providing a protective, conductive and soldera... Electroless nickel/immersion gold (ENIG) technology is widely used as one of the surface final finish for electronics packaging substrate and printed circuit board (PCB), providing a protective, conductive and solderable surface. However, there is a solder joint interfacial brittle fracture (or solderability failure) of using the ENIG coating. The characteristics and the application of ENIG technology were narrated in this paper. The research progress on the solderability failure of ENIG was introduced. The mechanism of 'black pad' and the possible measure of eliminating or alleviating the 'black pad' were also introduced. The development direction and market prospects of ENIG were prospected. 展开更多
关键词 electroless nickel immersion gold (ENIG) solderability failure black pad
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部