The destruction of gaseous styrene was studied using a low-temperature plasma induced by tubular multilayer dielectric barrier discharge(DBD).The results indicate that the applied voltage,gas flow rate,inlet styrene...The destruction of gaseous styrene was studied using a low-temperature plasma induced by tubular multilayer dielectric barrier discharge(DBD).The results indicate that the applied voltage,gas flow rate,inlet styrene concentration and reactor configuration play important roles in styrene removal efficiency (ηstyrene) and energy yield(EY).Values of ηstyrene and EY reached 96%and 15567 mg/kWh when the applied voltage,gas flow rate,inlet styrene concentration and layers of quartz tubes were set at 10.8 kV,5.0 m/s,229 mg/m^3 and 5 layers,respectively.A qualitative analysis of the byproducts and a detailed discussion of the reaction mechanism are also presented.The results could facilitate industrial applications of the new DBD reactor for waste gas treatment.展开更多
Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation,bacterial inactivation,sterilization,and cancer treatment,due to its high chemical activity and l...Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation,bacterial inactivation,sterilization,and cancer treatment,due to its high chemical activity and limited thermal damage.It is of great importance to develop portable plasma sources that are safe to human touch and suitable for outdoor and household operation.In this work,a portable and rechargeable low-temperature plasma spark discharge device(130 mm×80 mm×35 mm,300 g)was designed.The discharge frequency and plume length were optimized by the selection of resistance,capacitance,electrode gap,and ground electrode aperture.Results show that the spark plasma plume is generated with a length of 12 mm and a frequency of 10 Hz at a capacitance of 0.33μF.resistance of 1 MΩ,electrode gap of 2 mm,and ground electrode aperture of 1.5 mm.Biological tests indicate that the plasma produced by this device contains abundant reactive species,which can be applied in plasma biomedicine,including daily sterilization and wound healing.展开更多
The results of contact angle and X-ray photoelectron spectrometry ( XPS ) reveal the effects of plasma treatment. The treated polypropylene film shows improved wet ability. Comparing the different treating conditions,...The results of contact angle and X-ray photoelectron spectrometry ( XPS ) reveal the effects of plasma treatment. The treated polypropylene film shows improved wet ability. Comparing the different treating conditions, such as time and atmospheres, the results reveal that there may exist two parallel reactions. And the different atmosphere has the different action in plasma treatment also.展开更多
A discharge ignited by an AC power source in contact with deionized water as one of the electrodes is investigated.Immediately after initiation,the discharge exhibits a unique phenomenon:the gas-phase discharge is ext...A discharge ignited by an AC power source in contact with deionized water as one of the electrodes is investigated.Immediately after initiation,the discharge exhibits a unique phenomenon:the gas-phase discharge is extended into the liquid.Later,a cone-like structure is observed at the liquid surface.Synchronous monitoring of current–voltage characteristics and liquid properties versus time suggests that the discharge shapes are functions of the liquid properties.The spatio-temporal profiles indicate the potential effects of water,ambient air impurities,and metastable argon on the discharge chemistry.This becomes more obvious near the liquid surface due to increasing production of various transient reactive species such as centerdot OH and NO centerdot.Moreover,it is revealed that thermalization of the rotational population distributions of the rotational states(N′⩽6,J′⩽13/2)in the Q1 branch of the OH(A2Σ+,υ′=0→X2Π3/2,υ′′=0)band ro-vibrational system is influenced by the humid environment near the liquid surface.In addition,the transient behaviors of instantaneous concentrations of long-lived reactive species(LRS)such as H2O2,NO−2,and NO−3 are observed with lengthening the discharge time.The production of multiple transient and LRS proposes AC excited gas–liquid argon discharge as a potential applicant in industrial wastewater cleaning,clinical medicine,and agriculture.展开更多
In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas o...In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas.展开更多
The killing logarithms index in killing a vegetative form in an explosure of about 90s and a spore in an explosure of about 120s, by using a low-temperature plasma produced by dielectric barrier discharge (DBD), rea...The killing logarithms index in killing a vegetative form in an explosure of about 90s and a spore in an explosure of about 120s, by using a low-temperature plasma produced by dielectric barrier discharge (DBD), reached 5. The speed in killing the strains tested, by using a low-temperature plasma, was the highest with E. Coli, then S. Aureus and B. Subtilis var niger spore. The results of the scanning electron microscope showed that the low-temperature plasma destroyed the outer structure of the bacteria and that the vegetative form was more susceptible to the inactivation effect of the low-temperature plasma than was the spore. This indicated that the effects of the high voltage and high velocity particle flow, in plasma, penetrating through the outer structure of the bacteria might play a dominant role during the inactivation of the bacteria.展开更多
Phenolic compounds have very strong toxicity, so it has been paid sharply attention to find an effective way of controlling the wastewater containing phenolic compounds. The work on this subject done by domestic and o...Phenolic compounds have very strong toxicity, so it has been paid sharply attention to find an effective way of controlling the wastewater containing phenolic compounds. The work on this subject done by domestic and overseas scholars is studied in this paper, and the progress of researches on low-temperature plasma treatment is summarized through the electrical discharge types, mechanism, kinetics of phenolic compounds decomposition and combination of several methods with low-temperature plasma treatment. In addition, the crucial problem and the developing tendency on low-temperature plasma treatment for phenol-bearing wastewater are briefly discussed.展开更多
The dielectric barrier discharge (DBD) and pulse corona discharge(PCD) plasma generator was used to remove NH3, H2S, C7H8 etc. from atmosphere. The principle and characteristic of the two ways was discussed in the art...The dielectric barrier discharge (DBD) and pulse corona discharge(PCD) plasma generator was used to remove NH3, H2S, C7H8 etc. from atmosphere. The principle and characteristic of the two ways was discussed in the article. The test shows the result of PCD is better than that of DBD.展开更多
The low-temperature plasma (LTP) generated by dielectric barrier discharge (DBD) was used to sterilize the E.coli endotoxin, which is usually difficult to kill by traditional methods. Three different concentration...The low-temperature plasma (LTP) generated by dielectric barrier discharge (DBD) was used to sterilize the E.coli endotoxin, which is usually difficult to kill by traditional methods. Three different concentrations of bacterial endotoxin (1 EU/mL, 0.5 EU/mL and 0.25 EU/mL) were treated by LTP for different time (20 s, 40 s and 60 s). Tachypleus amebocyte lysate (TAL) method was employed to detect the concentration variation of bacterial endotoxin before and af- ter the plasma treatment, and endotoxic shock mice model was used to evaluate the inactivation effects of LTP on endotoxin for further study. Experimental results demonstrated that, DBD plasma can inactivate the bacterial endotoxin quickly and effectively, and when the LTP treatment time was increased, the concentrations of bacterial endotoxin decreased gradually (after 60 s plasma treatment, its inactivation effect was beyond the Chinese pharmacopoeia standard), and the average survival time of mice gradually extended. The possible inactivation mechanisms are proposed to be related to reactive oxygen species (ROSs).展开更多
A novel water treatment technique, based on a combination of electrospraying and pulsed corona discharge, has been used for bio-decontamination of wastewater. The electrospraying process has been found to increase the...A novel water treatment technique, based on a combination of electrospraying and pulsed corona discharge, has been used for bio-decontamination of wastewater. The electrospraying process has been found to increase the surface area of the treated wastewater, and hence increases the efficiency of the corona treatment process. The phase diagram of the discharge, which characterizes the discharge regimes, has been identified experimentally. The survival ratio of the microorganisms has been investigated experimentally as a function of the applied voltage and the numbers of treatment runs using air and oxygen as working gases. Microorganism surface has been examined using scanning electron microscope (SEM), which enabled in understanding the decontamination mechanisms of the treated microorganism. A complete decontamination has been achieved after only one run for an applied voltage higher than 16 kV when the discharge system was operated in oxygen gas. Optical emission spectrum of the electrosprayed water confirmed the existence of OH-radicals responsible for decontamination process.展开更多
Although the deuterium and helium have almost the same mass,a Penning Optical Gas Analyzer(POGA) system on the basis of the spectroscopic method and Penning discharging has been designed on EAST,since 2014.The POGA ...Although the deuterium and helium have almost the same mass,a Penning Optical Gas Analyzer(POGA) system on the basis of the spectroscopic method and Penning discharging has been designed on EAST,since 2014.The POGA system was developed successfully in 2015,it was the first time that EAST could detect helium partial pressure in deuterium plasma(wall conditioning and plasma operation scenario).With dedicated calibration and proper adjustment of the parameters,the minimum concentration of helium in deuterium gas can be measured as about 0.5% instead of 1% on the other tokamak devices.Moreover,the He and D2 partial pressures are measured simultaneously.At present,the measurable range of deuterium partial pressure is 1×10^-7 mbar to 1×10^-5mbar,meanwhile the range of helium is 1×10^-8 mbar to 1×10^-5 mbar.The measurable range can be modified by means of the adjustment of POGA system's parameters.It is possible to detect the interesting part of the gas with a time resolution of less than 5 ms(the 200 ms because of conductance of transfer pipe at present).The POGA system was routinely employed to wall conditioning and helium enrichment investigation in2015.Last but not the least,the low temperature plasma of POGA is generated by normal penning gauge Pfeiffer IKR gauge instead of Alcatel CF2 P,which has been suspended for a few years and was used for almost all the POGA systems in the world.展开更多
The physical model for glow discharge plasma has been modified. The modified model is also analytic and self-consistent. Electron density distribution under the conditions of longer gap separations and different worki...The physical model for glow discharge plasma has been modified. The modified model is also analytic and self-consistent. Electron density distribution under the conditions of longer gap separations and different working gas pressures has been analyzed, and comparison between theory and experiment has been made. The modified model has wider applications, and the theoretical results are in better agreement with the experimental.展开更多
The influence of different factors on the plasma chemical reactions is widely studied today. However, insufficient consideration is given to the research of paramagnetic phenomena which takes place in plasma systems. ...The influence of different factors on the plasma chemical reactions is widely studied today. However, insufficient consideration is given to the research of paramagnetic phenomena which takes place in plasma systems. The results of modeling the process of redistribution carbon isotopes between different phases while oxidizing it in high-frequency low-temperature plasma in an external magnetic field are shown in the article. The equilibrium concentrations of components involved in the oxidation process in a plasma system are defined. A principle possibility of isotope-selective plasma chemical reactions in a magnetic field was experimentally determined. The increase of concentration of 13C in the gas phase up to 1.3 times relative to natural abundance was obtained. It was found that the content of the carbon heavy isotope in the gas phase depends on the magnetic field action area. The best results were achieved with the combination of magnetic field impact area and the priority area of the appearance of plasma chemical reactions products.展开更多
基金supported by Key Project of Science and Technology Commission of Shanghai Municipality(No.13231201903)National Key Technology R&D Program of China(No.2011BAJ07B04)
文摘The destruction of gaseous styrene was studied using a low-temperature plasma induced by tubular multilayer dielectric barrier discharge(DBD).The results indicate that the applied voltage,gas flow rate,inlet styrene concentration and reactor configuration play important roles in styrene removal efficiency (ηstyrene) and energy yield(EY).Values of ηstyrene and EY reached 96%and 15567 mg/kWh when the applied voltage,gas flow rate,inlet styrene concentration and layers of quartz tubes were set at 10.8 kV,5.0 m/s,229 mg/m^3 and 5 layers,respectively.A qualitative analysis of the byproducts and a detailed discussion of the reaction mechanism are also presented.The results could facilitate industrial applications of the new DBD reactor for waste gas treatment.
基金supported by National Natural Science Foundation of China(Nos.51677083 and 51377075)Postgraduate Research and Practice Innovation Program of Jiangsu Province(SJCX18_0340)
文摘Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation,bacterial inactivation,sterilization,and cancer treatment,due to its high chemical activity and limited thermal damage.It is of great importance to develop portable plasma sources that are safe to human touch and suitable for outdoor and household operation.In this work,a portable and rechargeable low-temperature plasma spark discharge device(130 mm×80 mm×35 mm,300 g)was designed.The discharge frequency and plume length were optimized by the selection of resistance,capacitance,electrode gap,and ground electrode aperture.Results show that the spark plasma plume is generated with a length of 12 mm and a frequency of 10 Hz at a capacitance of 0.33μF.resistance of 1 MΩ,electrode gap of 2 mm,and ground electrode aperture of 1.5 mm.Biological tests indicate that the plasma produced by this device contains abundant reactive species,which can be applied in plasma biomedicine,including daily sterilization and wound healing.
文摘The results of contact angle and X-ray photoelectron spectrometry ( XPS ) reveal the effects of plasma treatment. The treated polypropylene film shows improved wet ability. Comparing the different treating conditions, such as time and atmospheres, the results reveal that there may exist two parallel reactions. And the different atmosphere has the different action in plasma treatment also.
基金by National Natural Science Foundation of China(No.51578309)。
文摘A discharge ignited by an AC power source in contact with deionized water as one of the electrodes is investigated.Immediately after initiation,the discharge exhibits a unique phenomenon:the gas-phase discharge is extended into the liquid.Later,a cone-like structure is observed at the liquid surface.Synchronous monitoring of current–voltage characteristics and liquid properties versus time suggests that the discharge shapes are functions of the liquid properties.The spatio-temporal profiles indicate the potential effects of water,ambient air impurities,and metastable argon on the discharge chemistry.This becomes more obvious near the liquid surface due to increasing production of various transient reactive species such as centerdot OH and NO centerdot.Moreover,it is revealed that thermalization of the rotational population distributions of the rotational states(N′⩽6,J′⩽13/2)in the Q1 branch of the OH(A2Σ+,υ′=0→X2Π3/2,υ′′=0)band ro-vibrational system is influenced by the humid environment near the liquid surface.In addition,the transient behaviors of instantaneous concentrations of long-lived reactive species(LRS)such as H2O2,NO−2,and NO−3 are observed with lengthening the discharge time.The production of multiple transient and LRS proposes AC excited gas–liquid argon discharge as a potential applicant in industrial wastewater cleaning,clinical medicine,and agriculture.
文摘In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas.
文摘The killing logarithms index in killing a vegetative form in an explosure of about 90s and a spore in an explosure of about 120s, by using a low-temperature plasma produced by dielectric barrier discharge (DBD), reached 5. The speed in killing the strains tested, by using a low-temperature plasma, was the highest with E. Coli, then S. Aureus and B. Subtilis var niger spore. The results of the scanning electron microscope showed that the low-temperature plasma destroyed the outer structure of the bacteria and that the vegetative form was more susceptible to the inactivation effect of the low-temperature plasma than was the spore. This indicated that the effects of the high voltage and high velocity particle flow, in plasma, penetrating through the outer structure of the bacteria might play a dominant role during the inactivation of the bacteria.
文摘Phenolic compounds have very strong toxicity, so it has been paid sharply attention to find an effective way of controlling the wastewater containing phenolic compounds. The work on this subject done by domestic and overseas scholars is studied in this paper, and the progress of researches on low-temperature plasma treatment is summarized through the electrical discharge types, mechanism, kinetics of phenolic compounds decomposition and combination of several methods with low-temperature plasma treatment. In addition, the crucial problem and the developing tendency on low-temperature plasma treatment for phenol-bearing wastewater are briefly discussed.
文摘The dielectric barrier discharge (DBD) and pulse corona discharge(PCD) plasma generator was used to remove NH3, H2S, C7H8 etc. from atmosphere. The principle and characteristic of the two ways was discussed in the article. The test shows the result of PCD is better than that of DBD.
基金supported in part by China Foundation for the Author of National Excellent Doctoral Dissertation(No.200338)Shaanxi Province Science and Technology Program(No.2010K16-04)+1 种基金the Fundamental Research Funds for the Central Universities (Nos.2009xjtujc18,xjj20100160)Guanghua Foundation for Medicine Innovation Research of China(No.0203419)
文摘The low-temperature plasma (LTP) generated by dielectric barrier discharge (DBD) was used to sterilize the E.coli endotoxin, which is usually difficult to kill by traditional methods. Three different concentrations of bacterial endotoxin (1 EU/mL, 0.5 EU/mL and 0.25 EU/mL) were treated by LTP for different time (20 s, 40 s and 60 s). Tachypleus amebocyte lysate (TAL) method was employed to detect the concentration variation of bacterial endotoxin before and af- ter the plasma treatment, and endotoxic shock mice model was used to evaluate the inactivation effects of LTP on endotoxin for further study. Experimental results demonstrated that, DBD plasma can inactivate the bacterial endotoxin quickly and effectively, and when the LTP treatment time was increased, the concentrations of bacterial endotoxin decreased gradually (after 60 s plasma treatment, its inactivation effect was beyond the Chinese pharmacopoeia standard), and the average survival time of mice gradually extended. The possible inactivation mechanisms are proposed to be related to reactive oxygen species (ROSs).
文摘A novel water treatment technique, based on a combination of electrospraying and pulsed corona discharge, has been used for bio-decontamination of wastewater. The electrospraying process has been found to increase the surface area of the treated wastewater, and hence increases the efficiency of the corona treatment process. The phase diagram of the discharge, which characterizes the discharge regimes, has been identified experimentally. The survival ratio of the microorganisms has been investigated experimentally as a function of the applied voltage and the numbers of treatment runs using air and oxygen as working gases. Microorganism surface has been examined using scanning electron microscope (SEM), which enabled in understanding the decontamination mechanisms of the treated microorganism. A complete decontamination has been achieved after only one run for an applied voltage higher than 16 kV when the discharge system was operated in oxygen gas. Optical emission spectrum of the electrosprayed water confirmed the existence of OH-radicals responsible for decontamination process.
基金funded by National Magnetic Confinement Fusion Science Program of China under Contract No.2013GB114004,No.2014GB106005 & No.2015GB101000National Nature Science Foundation of China under Contract No.11625524,No.11321092 and No.11405210partly supported by the Japan Society for the Promotion of ScienceNational Research Foundation of Korea-National Science Foundation of China(JSPS-NRF-NSFC) A3 Foresight Program in the field of Plasma Physics(NSFC No.11261140328)
文摘Although the deuterium and helium have almost the same mass,a Penning Optical Gas Analyzer(POGA) system on the basis of the spectroscopic method and Penning discharging has been designed on EAST,since 2014.The POGA system was developed successfully in 2015,it was the first time that EAST could detect helium partial pressure in deuterium plasma(wall conditioning and plasma operation scenario).With dedicated calibration and proper adjustment of the parameters,the minimum concentration of helium in deuterium gas can be measured as about 0.5% instead of 1% on the other tokamak devices.Moreover,the He and D2 partial pressures are measured simultaneously.At present,the measurable range of deuterium partial pressure is 1×10^-7 mbar to 1×10^-5mbar,meanwhile the range of helium is 1×10^-8 mbar to 1×10^-5 mbar.The measurable range can be modified by means of the adjustment of POGA system's parameters.It is possible to detect the interesting part of the gas with a time resolution of less than 5 ms(the 200 ms because of conductance of transfer pipe at present).The POGA system was routinely employed to wall conditioning and helium enrichment investigation in2015.Last but not the least,the low temperature plasma of POGA is generated by normal penning gauge Pfeiffer IKR gauge instead of Alcatel CF2 P,which has been suspended for a few years and was used for almost all the POGA systems in the world.
基金the National Natural Science Foundation of China.
文摘The physical model for glow discharge plasma has been modified. The modified model is also analytic and self-consistent. Electron density distribution under the conditions of longer gap separations and different working gas pressures has been analyzed, and comparison between theory and experiment has been made. The modified model has wider applications, and the theoretical results are in better agreement with the experimental.
文摘The influence of different factors on the plasma chemical reactions is widely studied today. However, insufficient consideration is given to the research of paramagnetic phenomena which takes place in plasma systems. The results of modeling the process of redistribution carbon isotopes between different phases while oxidizing it in high-frequency low-temperature plasma in an external magnetic field are shown in the article. The equilibrium concentrations of components involved in the oxidation process in a plasma system are defined. A principle possibility of isotope-selective plasma chemical reactions in a magnetic field was experimentally determined. The increase of concentration of 13C in the gas phase up to 1.3 times relative to natural abundance was obtained. It was found that the content of the carbon heavy isotope in the gas phase depends on the magnetic field action area. The best results were achieved with the combination of magnetic field impact area and the priority area of the appearance of plasma chemical reactions products.