期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
The Investigation of Oscillographic Chronopotentiometry at Silver Disk Electrode and Its Mechanism
1
作者 She Ying DONG Ke Qi YU +1 位作者 Hong Sheng TANG Hong GAO(Institute of Analytical Science, Northwest University, Xi’an 710069Graduate School, University of Science & TecnoLogy of China, Beijing 100039) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第7期615-616,共2页
A new method of oscillographic chronopotentiometry at silver disk electrode was investigated. By using it, a series of ions such as Pb, In, Cr, Tl, Bi etc. were determined. The detection limits are two or three orders... A new method of oscillographic chronopotentiometry at silver disk electrode was investigated. By using it, a series of ions such as Pb, In, Cr, Tl, Bi etc. were determined. The detection limits are two or three orders of magnitude lower than those by oscillographic chronopotentiometry at mercury electrode. The proposed method is characterized by fine sensitivity, stable oscillogram and no mercury. The research on the mechanism of this method shows that these achievements are caused by the characterristics of silver electroxidation and electroreduction and the oscillographic chronopotentiometry (OC). 展开更多
关键词 silver disk electrode oscillographic determination oscillographic chronopotentiometry
下载PDF
Investigations of Thallium(Ⅰ) Underpotential Deposition on the Silver Rotating Disk Electrode and Its Analytical Application
2
作者 WANG Chun ming ZHU Li 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第1期102-107,共6页
The cyclic voltammetry(CV) and the square wave technique were used for the investigations of thallium(Ⅰ) underpotential deposition(UPD) on the silver electrode. A solution of 10 \{mmol/L\} HClO 4+10 mmol/L NaCl was s... The cyclic voltammetry(CV) and the square wave technique were used for the investigations of thallium(Ⅰ) underpotential deposition(UPD) on the silver electrode. A solution of 10 \{mmol/L\} HClO 4+10 mmol/L NaCl was selected as the supporting electrolyte. The calibration plots for Tl(Ⅰ) concentration in the range of 2×10 -9 -1×10 -7 mol/L were obtained. The detection limit was 5×10 -10 mol/L. For the solutions of 4 0×10 -9 mol/L thallium added before the urine sample pretreatment procedure, the average recovery was 105 6% with a relative standard deviation(RSD) of 15 5%. 展开更多
关键词 Thallium(Ⅰ) Underpotential deposition silver rotating disk electrode Cyclic voltammetry Square wave anodic stripping voltammetry
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部