The corrosion behaviors of SUS316L stainless steel, Co Cr alloy and Ti 6Al 4V alloy in Ringer’s, PBS(-) and Hank’s solutions have been investigated. The results indicate that the corrosion of Ringer’s solution is t...The corrosion behaviors of SUS316L stainless steel, Co Cr alloy and Ti 6Al 4V alloy in Ringer’s, PBS(-) and Hank’s solutions have been investigated. The results indicate that the corrosion of Ringer’s solution is the strongest, then followed by PBS(-) and Hank’s solution. The presence of HPO 2- 4, H 2PO - 4, SO 2- 4 and glucose in the PBS(-)and Hank’s solution probably reduces the corrosion inhibitor and corrosion current. The decrease of the solution’s pH significantly increases the corrosion rate and susceptibility to localized corrosion of SUS316L SS and Co Cr alloy. However, Ti 6Al 4V alloy exhibits an exceptional stability and has only a slight increase of corrosion rate with decreasing pH.展开更多
Magnesium alloys were considered to be used as biodegradable implants due to their biocompatibility,biodegradability and nontoxicity.However,under the simultaneous action of corrosive environment and mechanical loadin...Magnesium alloys were considered to be used as biodegradable implants due to their biocompatibility,biodegradability and nontoxicity.However,under the simultaneous action of corrosive environment and mechanical loading in human body,magnesium alloys are easy to be affected by corrosion fatigue and stress corrosion cracking.In this work,the fatigue behavior of the extruded Mg-Zn-Y-Nd alloy used for vascular stents was studied both in air and in simulated body fluid(SBF).It was revealed that the fatigue limit of as-extruded Mg-Zn-Y-Nd alloy in air is about 65 MPa at 10^7 cycles,while there is no limit in SBF and shows a linear relationship between the fatigue life and stress amplitudes.The fatigue crack source in air was formed by the inclusions and defects.However,the stress corrosion and hydrogen embrittlement are the main reasons for the formation of the fatigue initial crack source in SBF.展开更多
Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365...Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order展开更多
In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SB...In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SBF)solution using immersion tests and electrochemical impedance spectroscopy(EIS).A 5μm melted layer with a homogeneous microstructure and an MgO film on the surface were achieved by laser radiation.Corrosion observations(hydrogen evolution,morphology and corrosion products)and EIS results revealed an improvement of corrosion resistance after laser treatment for 48 h.It was found a two-layer structure developed after 2 h immersion on both the untreated and laser-treated alloys,but the sequence of forming the two layers was opposite and greatly influenced by the laser-treated layer.The time-evolution corrosion processes on the untreated and laser-treated alloys were discussed,providing a better understanding of corrosion behavior of biodegradable Mg alloys modified by excimer laser.展开更多
Dense natural wollastonite bioceramics (CaSiO3) were prepared by a sintering method, varying the pressing load and sintering temperature, in order to obtain different phases of wollastonite, and different physical pro...Dense natural wollastonite bioceramics (CaSiO3) were prepared by a sintering method, varying the pressing load and sintering temperature, in order to obtain different phases of wollastonite, and different physical properties in the materials. The products were characterized by TGA-DTA, XRD, FT-IR, SEM-EDS, TEM and XPS techniques. The results indicate the presence of two polymorphic phases of wollastonite, the β-wollastonite and α-wollastonite with a transition temperature of the β phase to α phase at approximately 1250℃. These materials were soaked in a simulated body fluid (SBF) during 1, 2 and 3 weeks, to study their solubility and bioactivity. The effect of different wollastonite phases on the solubility of Ca and Si, as well as the capacity of producing layers of “newly formed apatite” on the surfaces of these materials in SBF solution were analyzed.展开更多
The results and main findings of studies reported in the literature in relation to the deposition of calcium phosphate on Ti in simulated body fluids are summarized. The effects of the surface hydroxyl groups and the ...The results and main findings of studies reported in the literature in relation to the deposition of calcium phosphate on Ti in simulated body fluids are summarized. The effects of the surface hydroxyl groups and the sign of surface charge on the nucleation of calcium phosphate are reviewed. One major controversy among the conclusions of different studies is the order of adsorption of the calcium ions and the phosphate ions in the initial stage of immersion. A simple model based on the amphoteric nature of the hydroxyl groups on Ti is proposed in an attempt to delineate the nucleation process for calcium phosphate on Ti in simulated body fluids. HPO4^2- ions interact with the hydroxyl groups via ion exchange and/or electrostatic attraction, and Ca^2+ ions, via electrostatic attraction only. There is no preferential order of adsorption. Seemingly inconsistent results in different studies possibly arise from different prior treatments of the samples, which affect the adsorption properties.展开更多
It is confirmed that the essential condition for glasses and glass-ceramics to bond to living bone is the formation of an apatite layer on their surfaces in the body.It is proposed that a hydrated silica formed on the...It is confirmed that the essential condition for glasses and glass-ceramics to bond to living bone is the formation of an apatite layer on their surfaces in the body.It is proposed that a hydrated silica formed on the surfaces of these materials in the body plays an important role in forming the surface apatite layer,which has not been proved yet.It is shown experimentally that a pure hydrated silica gel can induce the apatite formation on its surface in a simulated body fluid when its starting pH is increased from 7.2 to 7.4.展开更多
Electrochemical test technology and surface analysis method were employed to investigate the pitting corrosion of Cu-Zn-AI shape memory alloy in simulated uterine fluid. The results showed that the breakage of the bre...Electrochemical test technology and surface analysis method were employed to investigate the pitting corrosion of Cu-Zn-AI shape memory alloy in simulated uterine fluid. The results showed that the breakage of the breaking-renovating equilibrium of surface layers resulted in the pitting corrosion of Cu-Zn-AI shape memory alloy in simulated uterine fluid. The development of pitting corrosion was controlled by dissolution of surface layers. The critical pitting corrosion potential was 1.70 VSCE. The kinetics equation for the development of pitting corrosion for Cu-Zn-AI shape memory alloy in simulated uterine fluid was io=465.68 t-0.5+1.5. Pitting appearances of pits could be two types: tortoise-shell, and anomaly abscess. Cl- ion facilitated the pitting corrosion of Cu-Zn-AI shape memory alloy by competing adsorption and concentrating on alloy surface at high positive potential.展开更多
To maintain the high-density plasma source in inductively coupled plasma(ICP),very high radiofrequency power is often delivered to the antenna,which can heat the dielectric windows near the antenna to high temperature...To maintain the high-density plasma source in inductively coupled plasma(ICP),very high radiofrequency power is often delivered to the antenna,which can heat the dielectric windows near the antenna to high temperature.This high temperature can modulate the plasma characteristics to a large degree.We thus study the effect of dielectric window temperature on plasma parameters in two different ICP structures based on COMSOL software.The distributions of various plasma species are examined at different dielectric window temperatures.The concentration of neutral gas is found to be largely modulated at high dielectric window temperature,which further affects the electron collision probability with neutrals and the electron temperature.However,the electron density profiles are barely affected by the dielectric window temperature,which is mainly concentrated at the center of the reactor due to the fixed power input and pressure.展开更多
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m...Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity.展开更多
The settling flux of biodeposition affects the environmental quality of cage culture areas and determines their environmental carrying capacity.Simple and effective simulation of the settling flux of biodeposition is ...The settling flux of biodeposition affects the environmental quality of cage culture areas and determines their environmental carrying capacity.Simple and effective simulation of the settling flux of biodeposition is extremely important for determining the spatial distribution of biodeposition.Theoretically,biodeposition in cage culture areas without specific emission rules can be simplified as point source pollution.Fluent is a fluid simulation software that can simulate the dispersion of particulate matter simply and efficiently.Based on the simplification of pollution sources and bays,the settling flux of biodeposition can be easily and effectively simulated by Fluent fluid software.In the present work,the feasibility of this method was evaluated by simulation of the settling flux of biodeposition in Maniao Bay,Hainan Province,China,and 20 sampling sites were selected for determining the settling fluxes.At sampling sites P1,P2,P3,P4,P5,Z1,Z2,Z3,Z4,A1,A2,A3,A4,B1,B2,C1,C2,C3 and C4,the measured settling fluxes of biodeposition were 26.02,15.78,10.77,58.16,6.57,72.17,12.37,12.11,106.64,150.96,22.59,11.41,18.03,7.90,19.23,7.06,11.84,5.19 and 2.57 g d^(−1)m^(−2),respectively.The simulated settling fluxes of biodeposition at the corresponding sites were 16.03,23.98,8.87,46.90,4.52,104.77,16.03,8.35,180.83,213.06,39.10,17.47,20.98,9.78,23.25,7.84,15.90,6.06 and 1.65 g d^(−1)m^(−2),respectively.There was a positive correlation between the simulated settling fluxes and measured ones(R=0.94,P=2.22×10^(−9)<0.05),which implies that the spatial differentiation of biodeposition flux was well simulated.Moreover,the posterior difference ratio of the simulation was 0.38,and the small error probability was 0.94,which means that the simulated results reached an acceptable level from the perspective of relative error.Thus,if nonpoint source pollution is simplified to point source pollution and open waters are simplified based on similarity theory,the setting flux of biodeposition in the open waters can be simply and effectively simulated by the fluid simulation software Fluent.展开更多
Fixed-bed reactors are generally considered the optimal choice for numerous multi-phase catalytic reactions due to their excellent performance and stability.However,conventional fixed beds often encounter challenges r...Fixed-bed reactors are generally considered the optimal choice for numerous multi-phase catalytic reactions due to their excellent performance and stability.However,conventional fixed beds often encounter challenges related to inadequate mass transfer and a high pressure drop caused by the non-uniform void fraction distribution.To enhance the overall performance of fixed beds,the impact of different packing configurations on performance was investigated.Experimental and simulation methods were used to investigate the fluid flow and mass transfer performances of various packed beds under different flow rates.It was found that structured beds exhibited a significantly lower pressure drop per unit length than conventional packed beds.Furthermore,the packing configurations had a critical role in improving the overall performance of fixed beds.Specifically,structured packed beds,particularly the H-2 packing configuration,effectively reduced the pressure drop per unit length and improved the mass transfer efficiency.The H-2 packing configuration consisted of two parallel strips of particles in each layer,with strips arranged perpendicularly between adjacent layers,and the spacing between the strips varied from layer to layer.展开更多
Greece boasts an impressive closed coastline stretching across 13,676 km, making it the largest in the Mediterranean basin and one of the largest in the world. Given the significant human activities that take place in...Greece boasts an impressive closed coastline stretching across 13,676 km, making it the largest in the Mediterranean basin and one of the largest in the world. Given the significant human activities that take place in coastal areas, understanding the behavior of the sea environment becomes crucial. In this study, we delve into the generation and movement of marine currents as well as the retention time and water age within the waters of Pagasitikos Sea inlet, Greece, through numerical simulation of hydrodynamic characteristics. The main examined points of the understudy region are the area of the port of Volos, the Trikeri channel where the ingress and egress of water from the Gulf takes place and the exchange of seawater through circulation of the Pagasitikos Gulf with the North Evian Gulf. In order to evaluate the results, they were compared with real field measurements and with simulation on a laboratory dummy of the same area. The computational simulation was performed with the ELCOM 2.2 numerical modeling tool and the AEM3D latest version and the main factors simulated are the tide, the consequence that Coriolis force, boundary conditions, the topography and bottom geometry of the bay and the actual meteorological conditions of a whole year.展开更多
Currently, when magnesium alloy sheet is rolled, the method of controlling roll temperature is simple and inaccurate. Furthermore, roll temperature has a large influence on the quality of magnesium alloy sheet; theref...Currently, when magnesium alloy sheet is rolled, the method of controlling roll temperature is simple and inaccurate. Furthermore, roll temperature has a large influence on the quality of magnesium alloy sheet; therefore, a new model using circular fluid flow control roll temperature has been designed. A fluid heat transfer structure was designed, the heat transfer process model of the fluid heating roll was simplified, and the finite di erence method was used to cal?culate the heat transfer process. Fluent software was used to simulate the fluid?solid coupling heat transfer, and both the trend and regularity of the temperature field in the heat transfer process were identified. The results show that the heating e ciency was much higher than traditional heating methods(when the fluid heat of the roll and tempera?ture distribution of the roll surface was more uniform). Moreover, there was a bigger temperature di erence between the input and the output, and after using reverse flow the temperature di erence decreased. The axial and circum?ferential temperature distributions along the sheet were uniform. Both theoretical calculation results and numerical simulation results of the heat transfer between fluid and roll were compared. The error was 1.8%–12.3%, showing that the theoretical model can both forecast and regulate the temperature of the roll(for magnesium alloy sheets) in the rolling process.展开更多
The effect of flow control devices(FCDs) on the uniformity of flow characteristics in a seven-strand symmetrical trapezoidal tundish was studied using both an experimental 1:2.5 hydraulic model and a numerical simu...The effect of flow control devices(FCDs) on the uniformity of flow characteristics in a seven-strand symmetrical trapezoidal tundish was studied using both an experimental 1:2.5 hydraulic model and a numerical simulation of a 1:1 geometric model.The variation coefficient(CV) was defined to evaluate the flow uniformity of the seven-strand tundish.An optimized FCD configuration was proposed on the basis of the evaluation of experimental results.It is concluded that a turbulence inhibitor(TI) and U-type dam are essential to improve the uniformity of fluid flow in the seven-strand tundish.In addition,the configuration of inclination T-type dams with a height of 200 mm between the second and third strands and with a height of 300 mm between the third and fourth strands can minimize the proportion of dead zone.After optimizing the configuration of FCDs,the variation coefficient reduces below 20%of the mean value,and the average proportion of dead zone is just 14.6%;in addition,the temperature fluctuation between the strands could be controlled within 0.6 K.In summary,the uniformity of flow and temperature in the seven-strand tundish is greatly improved.展开更多
Computational fluid dynamics(CFD) simulations are adopted to investigate rectangular microchannel flows with various periodic micro-structured wall by introducing velocity slip boundary condition at low Reynolds num...Computational fluid dynamics(CFD) simulations are adopted to investigate rectangular microchannel flows with various periodic micro-structured wall by introducing velocity slip boundary condition at low Reynolds number. The purpose of the current study is to numerically find out the effects of periodic micro-structured wall on the flow resistance in rectangular microchannel with the different spacings between microridges ranging from 15 to 60 pm. The simulative results indicate that pressure drop with different spacing between microridges increases linearly with flow velocity and decreases monotonically with slip velocity; Pressure drop reduction also increases with the spacing between microridges at the same condition of slip velocity and flow velocity. The results of numerical simulation are compared with theoretical predictions and experimental results in the literatures. It is found that there is qualitative agreement between them.展开更多
In this work, a two-dimensional fluid model has been employed to study the characteristics of Ar/O2 radio frequency(RF) inductively coupled plasma discharges. The emphasis of this work has been put on the influence ...In this work, a two-dimensional fluid model has been employed to study the characteristics of Ar/O2 radio frequency(RF) inductively coupled plasma discharges. The emphasis of this work has been put on the influence of the external parameters(i.e., the RF power, the pressure, and the Ar/O2 gas ratio) on the plasma properties. The numerical results show that the RF power has a significant influence on the amplitude of the plasma density rather than on the spatial distribution.However, the pressure and the Ar/O2 gas ratio affect not only the amplitude of the plasma density, but also the spatial uniformity. Finally, the comparison between the simulation results and the experimental data has been made at different gas pressures and oxygen contents, and a good agreement has been achieved.展开更多
Using finite element technique of the plane-strain problem in solid-liquid two-phase medium, we Studied the char acteristics of 'field precursors' and 'focus precursors' of subsurface fluid and their s...Using finite element technique of the plane-strain problem in solid-liquid two-phase medium, we Studied the char acteristics of 'field precursors' and 'focus precursors' of subsurface fluid and their spatial-temporal evolution in case of dip-slip earthquake. The results show that: ① the change of ground fluid is slow and the anomaly is not prominent in the early period which is of elastic accumulation and non-linear; ② dilatancy emerges and anomalyfocus mainly in the source region in the moderate period which is hardening and of local dilatancy. In the period the focus precursors emerge earlier than the field precursors; ③ anomalies spreed continuously in the source area and new regions with big anomaly emerge out of the source region in the middle-short period which is of large scale dilatancy.展开更多
A new type of two-dimensional self-consistent fluid model that couples an equivalent circuit module is used to in- vestigate the mode transition characteristics and hysteresis in hydrogen inductively coupled plasmas a...A new type of two-dimensional self-consistent fluid model that couples an equivalent circuit module is used to in- vestigate the mode transition characteristics and hysteresis in hydrogen inductively coupled plasmas at different pressures, by varying the series capacitance of the matching box. The variations of the electron density, temperature, and the circuit electrical properties are presented. As cycling the matching capacitance, at high pressure both the discontinuity and hysteresis appear for the plasma parameters and the transferred impedances of both the inductive and capacitive discharge components, while at low pressure only the discontinuity is seen. The simulations predict that the sheath plays a determi- native role on the presence of discontinuity and hysteresis at high pressure, by influencing the inductive coupling efficiency of applied power. Moreover, the values of the plasma transferred impedances at different pressures are compared, and the larger plasma inductance at low pressure due to less collision frequency, as analyzed, is the reason why the hysteresis is not seen at low pressure, even with a wider sheath. Besides, the behaviors of the coil voltage and current parameters during the mode transitions are investigated. They both increase (decrease) at the E to H (H to E) mode transition, indicating an improved (worsened) inductive power coupling efficiency.展开更多
t A fluid model is employed to investigate the effect of radio frequency bias on the behavior of an argon inductively coupled plasma(ICP).In particular,the effects of ICP source power,single-frequency bias power,and d...t A fluid model is employed to investigate the effect of radio frequency bias on the behavior of an argon inductively coupled plasma(ICP).In particular,the effects of ICP source power,single-frequency bias power,and dual-frequency bias power on the characteristics of ICP are simulated at a fixed pressure of 30 mTorr(1 Torr=1.33322×102 Pa).When the bias frequency is fixed at 27.12 MHz,the two-dimensional(2D)plasma density profile is significantly affected by the bias power at low ICP source power(e.g.,50 W),whereas it is weakly affected by the bias power at higher ICP source power(e.g.,100 W).When dual-frequency(27.12 MHz/2.26 MHz)bias is applied and the sum of bias powers is fixed at 500 W,a pronounced increase in the maximum argon ion density is observed with the increase of the bias power ratio in the absence of ICP source power.As the ratio of 27.12-MHz/2.26-MHz bias power decreases from 500 W/0 W to 0 W/500 W with the ICP source power fixed at 50 W,the plasma density profiles smoothly shifts from edge-high to center-high,and the effect of bias power on the plasma distribution becomes weaker with the bias power ratio decreasing.Besides,the axial ion flux at the substrate surface is characterized by a maximum at the edge of the substrate.When the ICP source power is higher,the 2D plasma density profiles,as well as the spatiotemporal and radial distributions of ion flux at the substrate surface are characterized by a peak in the reactor center,and the distributions of plasma parameters are negligibly affected by the dual-frequency bias power ratio.展开更多
文摘The corrosion behaviors of SUS316L stainless steel, Co Cr alloy and Ti 6Al 4V alloy in Ringer’s, PBS(-) and Hank’s solutions have been investigated. The results indicate that the corrosion of Ringer’s solution is the strongest, then followed by PBS(-) and Hank’s solution. The presence of HPO 2- 4, H 2PO - 4, SO 2- 4 and glucose in the PBS(-)and Hank’s solution probably reduces the corrosion inhibitor and corrosion current. The decrease of the solution’s pH significantly increases the corrosion rate and susceptibility to localized corrosion of SUS316L SS and Co Cr alloy. However, Ti 6Al 4V alloy exhibits an exceptional stability and has only a slight increase of corrosion rate with decreasing pH.
基金The authors are grateful for the financial support of Key Projects of the Joint Fund of the National Natural Science Foundation of China(No.U1804251)the National Key Research and Development Program of China(No.2018YFC1106703,2017YFB0702504 and 2016YFC1102403).
文摘Magnesium alloys were considered to be used as biodegradable implants due to their biocompatibility,biodegradability and nontoxicity.However,under the simultaneous action of corrosive environment and mechanical loading in human body,magnesium alloys are easy to be affected by corrosion fatigue and stress corrosion cracking.In this work,the fatigue behavior of the extruded Mg-Zn-Y-Nd alloy used for vascular stents was studied both in air and in simulated body fluid(SBF).It was revealed that the fatigue limit of as-extruded Mg-Zn-Y-Nd alloy in air is about 65 MPa at 10^7 cycles,while there is no limit in SBF and shows a linear relationship between the fatigue life and stress amplitudes.The fatigue crack source in air was formed by the inclusions and defects.However,the stress corrosion and hydrogen embrittlement are the main reasons for the formation of the fatigue initial crack source in SBF.
基金This study was supported by National Key Scientific and Technological Project(2004BA720A32)
文摘Objective To compare the cupric ion releasing in vitro o.f the three IUDs. Methods The stability o.f cupric ion releasing o.f IUDs including TCu 380.4 IUD (TCu 380A), Multiload Cu375 IUD (MCu 375) and Yuangong 365 copper-bearing indomethacin-releasing IUD (Yuangong 365) by the determination of cupric ion releasing in simulated uterine fluid. The simulated uterine fluid was used for releasing media. Copper ion was determined by flame atomic absorption spectrometer. Results The cupric ion releasing of three IUDs were instable at the beginning and tend to be stable gradually. In the stable phase, the average level of cupric ion releasing of TCu380A, MCu375 and Yuangong 365 were 4.25±2.71-7.62±6.42 μg, 4.92±1.23 -8.62±3.08 μg and 2.19±0.40-4.68±1.66 μg, respectively. TCu380A had higher instable releasing level than those of Yuangong 365 (P〈0. 05). Conclusion TCu 380.4 and MCu 375 showed a "burst release" during the first few days and the.former was of great significance(P〈0.05). The initial cupric ion releasing of Yuangong 365 appeared to be the lowest, followed by MCu375 and TCu380A in a releasing order
文摘In this study,a KrF excimer laser was used to modify the biodegradable Mg-1Ca alloy and the time-evolution degradation behavior of the alloy before and after laser treatment was investigated in simulated body fluid(SBF)solution using immersion tests and electrochemical impedance spectroscopy(EIS).A 5μm melted layer with a homogeneous microstructure and an MgO film on the surface were achieved by laser radiation.Corrosion observations(hydrogen evolution,morphology and corrosion products)and EIS results revealed an improvement of corrosion resistance after laser treatment for 48 h.It was found a two-layer structure developed after 2 h immersion on both the untreated and laser-treated alloys,but the sequence of forming the two layers was opposite and greatly influenced by the laser-treated layer.The time-evolution corrosion processes on the untreated and laser-treated alloys were discussed,providing a better understanding of corrosion behavior of biodegradable Mg alloys modified by excimer laser.
文摘Dense natural wollastonite bioceramics (CaSiO3) were prepared by a sintering method, varying the pressing load and sintering temperature, in order to obtain different phases of wollastonite, and different physical properties in the materials. The products were characterized by TGA-DTA, XRD, FT-IR, SEM-EDS, TEM and XPS techniques. The results indicate the presence of two polymorphic phases of wollastonite, the β-wollastonite and α-wollastonite with a transition temperature of the β phase to α phase at approximately 1250℃. These materials were soaked in a simulated body fluid (SBF) during 1, 2 and 3 weeks, to study their solubility and bioactivity. The effect of different wollastonite phases on the solubility of Ca and Si, as well as the capacity of producing layers of “newly formed apatite” on the surfaces of these materials in SBF solution were analyzed.
文摘The results and main findings of studies reported in the literature in relation to the deposition of calcium phosphate on Ti in simulated body fluids are summarized. The effects of the surface hydroxyl groups and the sign of surface charge on the nucleation of calcium phosphate are reviewed. One major controversy among the conclusions of different studies is the order of adsorption of the calcium ions and the phosphate ions in the initial stage of immersion. A simple model based on the amphoteric nature of the hydroxyl groups on Ti is proposed in an attempt to delineate the nucleation process for calcium phosphate on Ti in simulated body fluids. HPO4^2- ions interact with the hydroxyl groups via ion exchange and/or electrostatic attraction, and Ca^2+ ions, via electrostatic attraction only. There is no preferential order of adsorption. Seemingly inconsistent results in different studies possibly arise from different prior treatments of the samples, which affect the adsorption properties.
文摘It is confirmed that the essential condition for glasses and glass-ceramics to bond to living bone is the formation of an apatite layer on their surfaces in the body.It is proposed that a hydrated silica formed on the surfaces of these materials in the body plays an important role in forming the surface apatite layer,which has not been proved yet.It is shown experimentally that a pure hydrated silica gel can induce the apatite formation on its surface in a simulated body fluid when its starting pH is increased from 7.2 to 7.4.
文摘Electrochemical test technology and surface analysis method were employed to investigate the pitting corrosion of Cu-Zn-AI shape memory alloy in simulated uterine fluid. The results showed that the breakage of the breaking-renovating equilibrium of surface layers resulted in the pitting corrosion of Cu-Zn-AI shape memory alloy in simulated uterine fluid. The development of pitting corrosion was controlled by dissolution of surface layers. The critical pitting corrosion potential was 1.70 VSCE. The kinetics equation for the development of pitting corrosion for Cu-Zn-AI shape memory alloy in simulated uterine fluid was io=465.68 t-0.5+1.5. Pitting appearances of pits could be two types: tortoise-shell, and anomaly abscess. Cl- ion facilitated the pitting corrosion of Cu-Zn-AI shape memory alloy by competing adsorption and concentrating on alloy surface at high positive potential.
基金financially supported by National Natural Science Foundation of China(NSFC)(Nos.12105035 and 11935005)Guangdong Basic and Applied Basic Research Foundation(No.2021B1515120018)+1 种基金the Fundamental Research Funds for the Central Universities(No.DUT21TD104)the Advanced Space Propulsion Laboratory of BICE and Beijing Engineering Research Center of Efficient and Green Aerospace Propulsion Technology(No.Lab ASP-2020-01)。
文摘To maintain the high-density plasma source in inductively coupled plasma(ICP),very high radiofrequency power is often delivered to the antenna,which can heat the dielectric windows near the antenna to high temperature.This high temperature can modulate the plasma characteristics to a large degree.We thus study the effect of dielectric window temperature on plasma parameters in two different ICP structures based on COMSOL software.The distributions of various plasma species are examined at different dielectric window temperatures.The concentration of neutral gas is found to be largely modulated at high dielectric window temperature,which further affects the electron collision probability with neutrals and the electron temperature.However,the electron density profiles are barely affected by the dielectric window temperature,which is mainly concentrated at the center of the reactor due to the fixed power input and pressure.
基金supported by the Scientific Research Foundation of Xijing University,China(No.XJ19T03)the Opening Project of Science and Technology on Reliability Physics and Application Technology of Electronic Component Laboratory(No.ZHD201701)the Natural Science Basic Research Plan in Shaanxi Province of China(No.2024JC-YBMS-342).
文摘Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity.
基金support from the National Key Research and Development Program of China(No.2018YFD0900704)the National Natural Science Foundation of China(No.31972796).
文摘The settling flux of biodeposition affects the environmental quality of cage culture areas and determines their environmental carrying capacity.Simple and effective simulation of the settling flux of biodeposition is extremely important for determining the spatial distribution of biodeposition.Theoretically,biodeposition in cage culture areas without specific emission rules can be simplified as point source pollution.Fluent is a fluid simulation software that can simulate the dispersion of particulate matter simply and efficiently.Based on the simplification of pollution sources and bays,the settling flux of biodeposition can be easily and effectively simulated by Fluent fluid software.In the present work,the feasibility of this method was evaluated by simulation of the settling flux of biodeposition in Maniao Bay,Hainan Province,China,and 20 sampling sites were selected for determining the settling fluxes.At sampling sites P1,P2,P3,P4,P5,Z1,Z2,Z3,Z4,A1,A2,A3,A4,B1,B2,C1,C2,C3 and C4,the measured settling fluxes of biodeposition were 26.02,15.78,10.77,58.16,6.57,72.17,12.37,12.11,106.64,150.96,22.59,11.41,18.03,7.90,19.23,7.06,11.84,5.19 and 2.57 g d^(−1)m^(−2),respectively.The simulated settling fluxes of biodeposition at the corresponding sites were 16.03,23.98,8.87,46.90,4.52,104.77,16.03,8.35,180.83,213.06,39.10,17.47,20.98,9.78,23.25,7.84,15.90,6.06 and 1.65 g d^(−1)m^(−2),respectively.There was a positive correlation between the simulated settling fluxes and measured ones(R=0.94,P=2.22×10^(−9)<0.05),which implies that the spatial differentiation of biodeposition flux was well simulated.Moreover,the posterior difference ratio of the simulation was 0.38,and the small error probability was 0.94,which means that the simulated results reached an acceptable level from the perspective of relative error.Thus,if nonpoint source pollution is simplified to point source pollution and open waters are simplified based on similarity theory,the setting flux of biodeposition in the open waters can be simply and effectively simulated by the fluid simulation software Fluent.
文摘Fixed-bed reactors are generally considered the optimal choice for numerous multi-phase catalytic reactions due to their excellent performance and stability.However,conventional fixed beds often encounter challenges related to inadequate mass transfer and a high pressure drop caused by the non-uniform void fraction distribution.To enhance the overall performance of fixed beds,the impact of different packing configurations on performance was investigated.Experimental and simulation methods were used to investigate the fluid flow and mass transfer performances of various packed beds under different flow rates.It was found that structured beds exhibited a significantly lower pressure drop per unit length than conventional packed beds.Furthermore,the packing configurations had a critical role in improving the overall performance of fixed beds.Specifically,structured packed beds,particularly the H-2 packing configuration,effectively reduced the pressure drop per unit length and improved the mass transfer efficiency.The H-2 packing configuration consisted of two parallel strips of particles in each layer,with strips arranged perpendicularly between adjacent layers,and the spacing between the strips varied from layer to layer.
文摘Greece boasts an impressive closed coastline stretching across 13,676 km, making it the largest in the Mediterranean basin and one of the largest in the world. Given the significant human activities that take place in coastal areas, understanding the behavior of the sea environment becomes crucial. In this study, we delve into the generation and movement of marine currents as well as the retention time and water age within the waters of Pagasitikos Sea inlet, Greece, through numerical simulation of hydrodynamic characteristics. The main examined points of the understudy region are the area of the port of Volos, the Trikeri channel where the ingress and egress of water from the Gulf takes place and the exchange of seawater through circulation of the Pagasitikos Gulf with the North Evian Gulf. In order to evaluate the results, they were compared with real field measurements and with simulation on a laboratory dummy of the same area. The computational simulation was performed with the ELCOM 2.2 numerical modeling tool and the AEM3D latest version and the main factors simulated are the tide, the consequence that Coriolis force, boundary conditions, the topography and bottom geometry of the bay and the actual meteorological conditions of a whole year.
基金National Natural Science Foundation of China(Grant No.U1510131)Key Research and Development Projects of Shanxi Province of China(Grant Nos.201603D121010,201603D111004)+3 种基金Science and Technology Project of Jin Cheng City of China(Grant No.20155010)Youth Program of National Natural Science Fund of China(Grant No.51604181)Project of Young Scholar of Shanxi ProvinceLeading Talent Project of Innovative Entrepreneurial Team of Jiangsu Province(Grant No.51501122)
文摘Currently, when magnesium alloy sheet is rolled, the method of controlling roll temperature is simple and inaccurate. Furthermore, roll temperature has a large influence on the quality of magnesium alloy sheet; therefore, a new model using circular fluid flow control roll temperature has been designed. A fluid heat transfer structure was designed, the heat transfer process model of the fluid heating roll was simplified, and the finite di erence method was used to cal?culate the heat transfer process. Fluent software was used to simulate the fluid?solid coupling heat transfer, and both the trend and regularity of the temperature field in the heat transfer process were identified. The results show that the heating e ciency was much higher than traditional heating methods(when the fluid heat of the roll and tempera?ture distribution of the roll surface was more uniform). Moreover, there was a bigger temperature di erence between the input and the output, and after using reverse flow the temperature di erence decreased. The axial and circum?ferential temperature distributions along the sheet were uniform. Both theoretical calculation results and numerical simulation results of the heat transfer between fluid and roll were compared. The error was 1.8%–12.3%, showing that the theoretical model can both forecast and regulate the temperature of the roll(for magnesium alloy sheets) in the rolling process.
基金supported by the National Natural Science Foundation of China (No.51404018)the Fundamental Research Funds for the Central Universities of China (No.FRF-TP-15-008A3)
文摘The effect of flow control devices(FCDs) on the uniformity of flow characteristics in a seven-strand symmetrical trapezoidal tundish was studied using both an experimental 1:2.5 hydraulic model and a numerical simulation of a 1:1 geometric model.The variation coefficient(CV) was defined to evaluate the flow uniformity of the seven-strand tundish.An optimized FCD configuration was proposed on the basis of the evaluation of experimental results.It is concluded that a turbulence inhibitor(TI) and U-type dam are essential to improve the uniformity of fluid flow in the seven-strand tundish.In addition,the configuration of inclination T-type dams with a height of 200 mm between the second and third strands and with a height of 300 mm between the third and fourth strands can minimize the proportion of dead zone.After optimizing the configuration of FCDs,the variation coefficient reduces below 20%of the mean value,and the average proportion of dead zone is just 14.6%;in addition,the temperature fluctuation between the strands could be controlled within 0.6 K.In summary,the uniformity of flow and temperature in the seven-strand tundish is greatly improved.
基金National Natural Science Foundation of China (No.50435030)
文摘Computational fluid dynamics(CFD) simulations are adopted to investigate rectangular microchannel flows with various periodic micro-structured wall by introducing velocity slip boundary condition at low Reynolds number. The purpose of the current study is to numerically find out the effects of periodic micro-structured wall on the flow resistance in rectangular microchannel with the different spacings between microridges ranging from 15 to 60 pm. The simulative results indicate that pressure drop with different spacing between microridges increases linearly with flow velocity and decreases monotonically with slip velocity; Pressure drop reduction also increases with the spacing between microridges at the same condition of slip velocity and flow velocity. The results of numerical simulation are compared with theoretical predictions and experimental results in the literatures. It is found that there is qualitative agreement between them.
基金Project supported by the National Science and Technology Major Project of the Ministry of Science and Technology of China(Grant No.2011ZX02403-001)the National Natural Science Foundation of China(Grant No.11205025)
文摘In this work, a two-dimensional fluid model has been employed to study the characteristics of Ar/O2 radio frequency(RF) inductively coupled plasma discharges. The emphasis of this work has been put on the influence of the external parameters(i.e., the RF power, the pressure, and the Ar/O2 gas ratio) on the plasma properties. The numerical results show that the RF power has a significant influence on the amplitude of the plasma density rather than on the spatial distribution.However, the pressure and the Ar/O2 gas ratio affect not only the amplitude of the plasma density, but also the spatial uniformity. Finally, the comparison between the simulation results and the experimental data has been made at different gas pressures and oxygen contents, and a good agreement has been achieved.
文摘Using finite element technique of the plane-strain problem in solid-liquid two-phase medium, we Studied the char acteristics of 'field precursors' and 'focus precursors' of subsurface fluid and their spatial-temporal evolution in case of dip-slip earthquake. The results show that: ① the change of ground fluid is slow and the anomaly is not prominent in the early period which is of elastic accumulation and non-linear; ② dilatancy emerges and anomalyfocus mainly in the source region in the moderate period which is hardening and of local dilatancy. In the period the focus precursors emerge earlier than the field precursors; ③ anomalies spreed continuously in the source area and new regions with big anomaly emerge out of the source region in the middle-short period which is of large scale dilatancy.
基金supported by the National Natural Science Foundation of China(Grant Nos.11175034,11205025,11305023,and 11075029)
文摘A new type of two-dimensional self-consistent fluid model that couples an equivalent circuit module is used to in- vestigate the mode transition characteristics and hysteresis in hydrogen inductively coupled plasmas at different pressures, by varying the series capacitance of the matching box. The variations of the electron density, temperature, and the circuit electrical properties are presented. As cycling the matching capacitance, at high pressure both the discontinuity and hysteresis appear for the plasma parameters and the transferred impedances of both the inductive and capacitive discharge components, while at low pressure only the discontinuity is seen. The simulations predict that the sheath plays a determi- native role on the presence of discontinuity and hysteresis at high pressure, by influencing the inductive coupling efficiency of applied power. Moreover, the values of the plasma transferred impedances at different pressures are compared, and the larger plasma inductance at low pressure due to less collision frequency, as analyzed, is the reason why the hysteresis is not seen at low pressure, even with a wider sheath. Besides, the behaviors of the coil voltage and current parameters during the mode transitions are investigated. They both increase (decrease) at the E to H (H to E) mode transition, indicating an improved (worsened) inductive power coupling efficiency.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11875101 and 11905307).
文摘t A fluid model is employed to investigate the effect of radio frequency bias on the behavior of an argon inductively coupled plasma(ICP).In particular,the effects of ICP source power,single-frequency bias power,and dual-frequency bias power on the characteristics of ICP are simulated at a fixed pressure of 30 mTorr(1 Torr=1.33322×102 Pa).When the bias frequency is fixed at 27.12 MHz,the two-dimensional(2D)plasma density profile is significantly affected by the bias power at low ICP source power(e.g.,50 W),whereas it is weakly affected by the bias power at higher ICP source power(e.g.,100 W).When dual-frequency(27.12 MHz/2.26 MHz)bias is applied and the sum of bias powers is fixed at 500 W,a pronounced increase in the maximum argon ion density is observed with the increase of the bias power ratio in the absence of ICP source power.As the ratio of 27.12-MHz/2.26-MHz bias power decreases from 500 W/0 W to 0 W/500 W with the ICP source power fixed at 50 W,the plasma density profiles smoothly shifts from edge-high to center-high,and the effect of bias power on the plasma distribution becomes weaker with the bias power ratio decreasing.Besides,the axial ion flux at the substrate surface is characterized by a maximum at the edge of the substrate.When the ICP source power is higher,the 2D plasma density profiles,as well as the spatiotemporal and radial distributions of ion flux at the substrate surface are characterized by a peak in the reactor center,and the distributions of plasma parameters are negligibly affected by the dual-frequency bias power ratio.