期刊文献+
共找到20篇文章
< 1 >
每页显示 20 50 100
Imaging simulation and analysis of attitude jitter effect on topographic mapping for lunar orbiter stereo optical cameras
1
作者 CHEN Chen TONG Xiao-Hua +4 位作者 LIU Shi-Jie YE Zhen HUANG Chao-Wei WU Hao ZHANG Han 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2024年第5期722-730,共9页
The geometric accuracy of topographic mapping with high-resolution remote sensing images is inevita-bly affected by the orbiter attitude jitter.Therefore,it is necessary to conduct preliminary research on the stereo m... The geometric accuracy of topographic mapping with high-resolution remote sensing images is inevita-bly affected by the orbiter attitude jitter.Therefore,it is necessary to conduct preliminary research on the stereo mapping camera equipped on lunar orbiter before launching.In this work,an imaging simulation method consid-ering the attitude jitter is presented.The impact analysis of different attitude jitter on terrain undulation is conduct-ed by simulating jitter at three attitude angles,respectively.The proposed simulation method is based on the rigor-ous sensor model,using the lunar digital elevation model(DEM)and orthoimage as reference data.The orbit and attitude of the lunar stereo mapping camera are simulated while considering the attitude jitter.Two-dimensional simulated stereo images are generated according to the position and attitude of the orbiter in a given orbit.Experi-mental analyses were conducted by the DEM with the simulated stereo image.The simulation imaging results demonstrate that the proposed method can ensure imaging efficiency without losing the accuracy of topographic mapping.The effect of attitude jitter on the stereo mapping accuracy of the simulated images was analyzed through a DEM comparison. 展开更多
关键词 topographic mapping lunar orbiter stereo camera attitude jitter imaging simulation digital elevation model
下载PDF
Infrared image simulation of ground maneuver target and scene
2
作者 穆成坡 彭明松 +2 位作者 高翔 张睿恒 董清先 《Journal of Beijing Institute of Technology》 EI CAS 2016年第2期247-253,共7页
Infrared scene simulation has extensive applications in military and civil fields. Based on a certain experimental environment,object-oriented graphics rendering engine( OGRE) is utilized to simulate a real three-di... Infrared scene simulation has extensive applications in military and civil fields. Based on a certain experimental environment,object-oriented graphics rendering engine( OGRE) is utilized to simulate a real three-dimensional infrared complex scene. First,the target radiation of each part is calculated based on our experimental data. Then through the analysis of the radiation characteristics of targets and related material,an infrared texture library is established and the 3ds Max software is applied to establish an infrared radiation model.Finally,a real complex infrared scene is created by using the OGRE engine image rendering technology and graphic processing unit( GPU) programmable pipeline technology. The results show that the simulation images are very similar to real images and are good supplements to real data. 展开更多
关键词 maneuver target target scene image simulation infrared image object-orientedgraphics rendering engine (OGRE)
下载PDF
Simulation Study on SAR Images of the Oceanic Internal Waves
3
作者 种劲松 李飞 欧阳越 《Journal of Measurement Science and Instrumentation》 CAS 2010年第1期37-40,共4页
Based on the research of Lynett and Liu, the horizontal fully two-dimensional, depth-integrated model for the internal wave propagation is re-deduced. By combining this model with the M4S model, the propagation proces... Based on the research of Lynett and Liu, the horizontal fully two-dimensional, depth-integrated model for the internal wave propagation is re-deduced. By combining this model with the M4S model, the propagation process of the internal waves is simulated in Synthetic Aperture Radar (SAR) images. The simulation results clearly show the bottom effects during the propagation such as fission and isobaths-parallelized propagation direction. This simulation procedure can lay the foundation for the quantitative interpretation of internal waves from fully two-dimensional SAR images. 展开更多
关键词 SAR image simulation internal waves
下载PDF
Three-dimensional image simulation of primary diaphragmatic hemangioma: A case report
4
作者 Pei-Yi Chu Kuan-Hsun Lin +2 位作者 Hao-Lun Kao Yi-Jen Peng Tsai-Wang Huang 《World Journal of Clinical Cases》 SCIE 2019年第24期4307-4313,共7页
BACKGROUND Fewer than 200 cases of diaphragmatic tumors have been reported in the past century. Diaphragmatic hemangiomas are extremely rare. Only nine cases have been reported in English literature to date. We report... BACKGROUND Fewer than 200 cases of diaphragmatic tumors have been reported in the past century. Diaphragmatic hemangiomas are extremely rare. Only nine cases have been reported in English literature to date. We report a case of cavernous hemangioma arising from the diaphragm. Pre-operative three-dimensional(3D)simulation and minimal invasive thoracoscopic excision were performed successfully, and we describe the radiologic findings and the surgical procedure in the following article.CASE SUMMARY A 40-year-old man was referred for further examination of a mass over the right basal lung without specific symptoms. Contrast-enhanced computed tomography revealed a poorly-enhanced lesion in the right basal lung, abutting to the diaphragm, measuring 3.1 cm × 1.5 cm in size. The mediastinum showed a clear appearance without evidence of abnormal mass or lymphadenopathy. A preoperative 3D image was reconstructed, which revealed a diaphragmatic lesion. Video-assisted thoracic surgery was performed, and a red papillary tumor was found, originating from the right diaphragm. The tumor was resected, and the pathological diagnosis was cavernous hemangioma.CONCLUSION In this rare case of diaphragmatic hemangioma, 3D image simulation was helpful for the preoperative evaluation and surgical decision making. 展开更多
关键词 Diaphragmatic tumor HEMANGIOMA Case report Three-dimensional image simulation Video-assisted thoracic surgery THORACOSCOPY
下载PDF
The image simulation arithmetic of the degradating process of porous biologic ceramic in life-form
5
《Chinese Journal of Biomedical Engineering(English Edition)》 2001年第3期152-154,共3页
关键词 life The image simulation arithmetic of the degradating process of porous biologic ceramic in life-form
下载PDF
Exploring Image Generation for UAV Change Detection 被引量:3
6
作者 Xuan Li Haibin Duan +1 位作者 Yonglin Tian Fei-Yue Wang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2022年第6期1061-1072,共12页
Change detection(CD)is becoming indispensable for unmanned aerial vehicles(UAVs),especially in the domain of water landing,rescue and search.However,even the most advanced models require large amounts of data for mode... Change detection(CD)is becoming indispensable for unmanned aerial vehicles(UAVs),especially in the domain of water landing,rescue and search.However,even the most advanced models require large amounts of data for model training and testing.Therefore,sufficient labeled images with different imaging conditions are needed.Inspired by computer graphics,we present a cloning method to simulate inland-water scene and collect an auto-labeled simulated dataset.The simulated dataset consists of six challenges to test the effects of dynamic background,weather,and noise on change detection models.Then,we propose an image translation framework that translates simulated images to synthetic images.This framework uses shared parameters(encoder and generator)and 22×22 receptive fields(discriminator)to generate realistic synthetic images as model training sets.The experimental results indicate that:1)different imaging challenges affect the performance of change detection models;2)compared with simulated images,synthetic images can effectively improve the accuracy of supervised models. 展开更多
关键词 Change detection computer graphics image translation simulated images synthetic images unmanned aerial vehicles(UAVs)
下载PDF
Objective measurement for image defogging algorithms 被引量:4
7
作者 郭璠 唐琎 蔡自兴 《Journal of Central South University》 SCIE EI CAS 2014年第1期272-286,共15页
Since there is lack of methodology to assess the performance of defogging algorithm and the existing assessment methods have some limitations,three new methods for assessing the defogging algorithm were proposed.One w... Since there is lack of methodology to assess the performance of defogging algorithm and the existing assessment methods have some limitations,three new methods for assessing the defogging algorithm were proposed.One was using synthetic foggy image simulated by image degradation model to assess the defogging algorithm in full-reference way.In this method,the absolute difference was computed between the synthetic image with and without fog.The other two were computing the fog density of gray level image or constructing assessment system of color image from human visual perception to assess the defogging algorithm in no-reference way.For these methods,an assessment function was defined to evaluate algorithm performance from the function value.Using the defogging algorithm comparison,the experimental results demonstrate the effectiveness and reliability of the proposed methods. 展开更多
关键词 image defogging algorithm image assessment simulated foggy image fog density human visual perception
下载PDF
SIMULATION OF SHIP GENERATED TURBULENT AND VORTICAL WAKE IMAGING BY SAR 被引量:2
8
作者 WangAiming ZhuMinhui 《Journal of Electronics(China)》 2004年第1期64-71,共8页
Synthetic Aperture Radar (SAR) imaging of ocean surface features is studied. The simulation of the turbulent and vortical features generated by a moving ship and SAR imaging of these wakes is carried out. The turbulen... Synthetic Aperture Radar (SAR) imaging of ocean surface features is studied. The simulation of the turbulent and vortical features generated by a moving ship and SAR imaging of these wakes is carried out. The turbulent wake damping the ocean surface capillary waves may be partially responsible for the suppression of surface waves near the ship track. The vortex pair generating a change in the lateral flow field behind the ship may be partially responsible for an enhancement of the waves near the edges of the smooth area. These hydrodynamic phenomena as well as the changes of radar backscatter generated by turbulence and vortex are simulated.An SAR imaging model is then used on such ocean surface features to provide SAR images.Comparison of two ships' simulated SAR images shows that the wake features are different for various ship parameters. 展开更多
关键词 Turbulent and vortical wake SAR Imaging simulation
下载PDF
Effects of mesh style and grid convergence on numerical simulation accuracy of centrifugal pump 被引量:2
9
作者 刘厚林 刘明明 +1 位作者 白羽 董亮 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期368-376,共9页
In order to evaluate the effects of mesh generation techniques and grid convergence on pump performance in centrifugal pump model, three widely used mesh styles including structured hexahedral, unstructured tetrahedra... In order to evaluate the effects of mesh generation techniques and grid convergence on pump performance in centrifugal pump model, three widely used mesh styles including structured hexahedral, unstructured tetrahedral and hybrid prismatic/tetrahedral meshes were generated for a centrifugal pump model. And quantitative grid convergence was assessed based on a grid convergence index(GCI), which accounts for the degree of grid refinement. The structured, unstructured or hybrid meshes are found to have certain difference for velocity distributions in impeller with the change of grid cell number. And the simulation results have errors to different degrees compared with experimental data. The GCI-value for structured meshes calculated is lower than that for the unstructured and hybrid meshes. Meanwhile, the structured meshes are observed to get more vortexes in impeller passage.Nevertheless, the hybrid meshes are found to have larger low-velocity area at outlet and more secondary vortexes at a specified location than structured meshes and unstructured meshes. 展开更多
关键词 mesh style grid convergence index(GCI) numerical simulation particle image velocimetry(PIV) centrifugal pump
下载PDF
Personalized cardiovascular intervention simulation system 被引量:3
10
作者 Aimin HAO Jiahao CUI +1 位作者 Shuai LI Qinping ZHAO 《Virtual Reality & Intelligent Hardware》 2020年第2期104-118,共15页
Background This study proposes a series of geometry and physics modeling methods for personalized cardiovascular intervention procedures,which can be applied to a virtual endovascular simulator.Methods Based on person... Background This study proposes a series of geometry and physics modeling methods for personalized cardiovascular intervention procedures,which can be applied to a virtual endovascular simulator.Methods Based on personalized clinical computed tomography angiography(CTA)data,mesh models of the cardiovascular system were constructed semi-automatically.By coupling 4 D magnetic resonance imaging(MRI)sequences corresponding to a complete cardiac cycle with related physics models,a hybrid kinetic model of the cardiovascular system was built to drive kinematics and dynamics simulation.On that basis,the surgical procedures related to intervention instruments were simulated using specially-designed physics models.These models can be solved in real-time;therefore,the complex interactions between blood vessels and instruments can be well simulated.Additionally,X-ray imaging simulation algorithms and realistic rendering algorithms for virtual intervention scenes are also proposed.In particular,instrument tracking hardware with haptic feedback was developed to serve as the interaction interface of real instruments and the virtual intervention system.Finally,a personalized cardiovascular intervention simulation system was developed by integrating the techniques mentioned above.Results This system supported instant modeling and simulation of personalized clinical data and significantly improved the visual and haptic immersions of vascular intervention simulation.Conclusions It can be used in teaching basic cardiology and effectively satisfying the demands of intervention training,personalized intervention planning,and rehearsing. 展开更多
关键词 Personalized cardiovascular modeling Intervention simulation system Intervention instrument simulation X-ray imaging simulation Hybrid model
下载PDF
Simulation and Experimental Method for Microwave Oven 被引量:3
11
作者 Han-Ji Ju Qing Zhao 《Journal of Electronic Science and Technology of China》 2009年第2期188-191,共4页
The simulation software, HFSS (high frequency structure simulator), is introduced in microwave oven design. In the cold test, a network analyzer is used to measure the reflection coefficient (S11) of the cavity un... The simulation software, HFSS (high frequency structure simulator), is introduced in microwave oven design. In the cold test, a network analyzer is used to measure the reflection coefficient (S11) of the cavity under empty and loaded states over the frequency range from 2.448 GHz to 2.468 GHz. In the hot test, a piece of wet thermal paper and an infrared thermal imaging camera are used to measure the electric field distributions on the mica and turntable. In the cold test, the simulation agrees well with the experiment no matter in empty state or loaded state. In the hot test, the simulation agrees well with the experiment in general in empty state and approximately in loaded state. The little difference in both cold and hot test may be due to that the model in simulation is not absolutely identical with that in experiment or the inadequate precision of infrared thermal imaging camera. 展开更多
关键词 Index Terms-Far-infrared thermal imaging camera microwave oven simulation network analyzer wetthermal paper.
下载PDF
ANALYSIS OF SPECTRAL CHARACTERISTICS AMONG DIFFERENT SENSORS BY USE OF SIMULATED RS IMAGES
12
作者 YE Zetian GU Xingfa LIU Xianlin WANG Zhimin 《Geo-Spatial Information Science》 2000年第2期35-40,共6页
This research,by use of RS image_simulating method,simulated apparent reflectance images at sensor level and ground_reflectance images of SPOT_HRV,CBERS_CCD,Landsat_TM and NOAA14_AVHRR’s corresponding bands.These ima... This research,by use of RS image_simulating method,simulated apparent reflectance images at sensor level and ground_reflectance images of SPOT_HRV,CBERS_CCD,Landsat_TM and NOAA14_AVHRR’s corresponding bands.These images were used to analyze sensor’s differences caused by spectral sensitivity and atmospheric impacts.The differences were analyzed on Normalized Difference Vegetation Index(NDVI).The results showed that the differences of sensors’ spectral characteristics cause changes of their NDVI and reflectance.When multiple sensors’ data are applied to digital analysis,the error should be taken into account.Atmospheric effect makes NDVI smaller,and atmospheric correction has the tendency of increasing NDVI values.The reflectance and their NDVIs of different sensors can be used to analyze the differences among sensor’s features.The spectral analysis method based on RS simulated images can provide a new way to design the spectral characteristics of new sensors. 展开更多
关键词 simulated RS image sensor spectral characteristics vegetation index analysis
下载PDF
Clinical application of improved 2D computer-assisted fluoroscopic navigation through simulating a 3D vertebrae image to guide pedicle screw internal fixation
13
作者 刘恩志 《外科研究与新技术》 2011年第2期94-94,共1页
Objective To study the effect of using improved 2D computer-assisted fluoroscopic navigation through simulating 3D vertebrae image to guide pedicle screw internal fixation.Methods Posterior pedicle screw internal fixa... Objective To study the effect of using improved 2D computer-assisted fluoroscopic navigation through simulating 3D vertebrae image to guide pedicle screw internal fixation.Methods Posterior pedicle screw internal fixation,distraction 展开更多
关键词 Clinical application of improved 2D computer-assisted fluoroscopic navigation through simulating a 3D vertebrae image to guide pedicle screw internal fixation
下载PDF
EVALUATION OF SMALL ANIMAL IMAGING UNDER DIFFERENT SCAN CONDITIONS
14
作者 贾鹏翔 王浩宇 +4 位作者 闫镔 李磊 陈健 张锋 包尚联 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第1期27-33,共7页
To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat i... To evaluae small animal imaging with individual different high voltage, filter thickness and tube current, an animal X-ray micro-computed tomography (micro-CT) system based on panel detector is developed and a rat is scanned by using the system with individual high voltage, tube current, filter thickness, and exposure time. A model is presented based on the Monte Carlo code PENELOPE for generating the X-ray spectra of X-ray tube used in the micro-CT system. A platform developed based on Matlab allows for calculating beam quality parameters, including the average energy of X-ray beam, the change of transmition rate and the input X-ray fluence. The factors affecting the signal difference to noise ratio (SDNR) of micro-CT are investigated and the relationship between SDNR and scan combinations is analyzed. A series of tools and methods are developed for small animal imaging and imaging performance evaluation in the field of small animal imaging. 展开更多
关键词 imaging techniques micro-computed tomography (CT) imaging performance Monte Carlo simulation
下载PDF
Simple PSF based method for pupil phase mask’s optimization in wavefront coding system 被引量:2
15
作者 ZHANG Wen-zi CHEN Yan-ping +2 位作者 ZHAO Ting-yu YE Zi YU Fei-hong 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第2期180-185,共6页
By applying the wavefront coding technique to an optical system, the depth of focus can be greatly increased. Several complicated methods, such as Fisher Information based method, have already been taken to optimize f... By applying the wavefront coding technique to an optical system, the depth of focus can be greatly increased. Several complicated methods, such as Fisher Information based method, have already been taken to optimize for the best pupil phase mask in ideal condition. Here one simple point spread function (PSF) based method with only the standard deviation method used to evaluate the PSF stability over the depth of focus is taken to optimize for the best coefficients of pupil phase mask in practical optical systems. Results of imaging simulations for optical systems with and without pupil phase mask are presented, and the sharpness of image is calculated for comparison. The optimized results showed better and much more stable imaging quality over the original system without changing the position of the image plane. 展开更多
关键词 Wavefront coding Pupil phase mask Depth of focus PSF stability OPTIMIZATION SHARPNESS Imaging simulation
下载PDF
Effect of Fiber Properties on Nonwovens' Pore Structures with Fractal Geometry Analysis
16
作者 杨旭红 李栋高 《Journal of Donghua University(English Edition)》 EI CAS 2005年第4期103-108,共6页
Nonwovens' pore structures are very important to their mechanical and physical properties. And the pore structures are influenced by the fiber properties and fibers arrangement in web. In this paper, the fractal geom... Nonwovens' pore structures are very important to their mechanical and physical properties. And the pore structures are influenced by the fiber properties and fibers arrangement in web. In this paper, the fractal geometry, in combination with computer image anaysis, is used to express the irregularity of pore size distribution in nonwovens, and the effect of fiber properties on fractal dimension of pore size distribution is discussed by using simulated images which are composed of nonlinear staple fibers. The results show that the fiber properties, such as crimp, diameter, angular distribution, and especially the number of fibers prominently influence the pore structure. 展开更多
关键词 NONWOVENS fiber properties fractal dimension of pore size distribution simulated images.
下载PDF
Low complexity MIMO sonar imaging using a virtual sparse linear array
17
作者 Xionghou Liu Chao Sun +2 位作者 Yixin Yang Jie Zhuo Yina Han 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2016年第2期370-378,共9页
A multiple-input multiple-output(MIMO) sonar can synthesize a large-aperture virtual uniform linear array(ULA) from a small number of physical elements. However, the large aperture is obtained at the cost of a gre... A multiple-input multiple-output(MIMO) sonar can synthesize a large-aperture virtual uniform linear array(ULA) from a small number of physical elements. However, the large aperture is obtained at the cost of a great number of matched filters with much heavy computation load. To reduce the computation load, a MIMO sonar imaging method using a virtual sparse linear array(SLA) is proposed, which contains the offline and online processing. In the offline processing, the virtual ULA of the MIMO sonar is thinned to a virtual SLA by the simulated annealing algorithm, and matched filters corresponding to inactive virtual elements are removed. In the online processing, outputs of matched filters corresponding to active elements are collected for further multibeam processing and hence, the number of matched filters in the echo processing procedure is effectively reduced. Numerical simulations show that the proposed method can reduce the computation load effectively while obtaining a similar imaging performance as the traditional method. 展开更多
关键词 multiple-input multiple-output(MIMO) sonar simulated annealing sonar imaging sparse arrays
下载PDF
SAR IMAGING SIMULATION OF HORIZONTAL FULLY TWO-DIMENSIONAL INTERNAL WAVES 被引量:11
18
作者 SHEN Hui HE Yi-Jun 《Journal of Hydrodynamics》 SCIE EI CSCD 2006年第3期294-302,共9页
Based on the research of Lynett and Liu, a new horizontal fully two-dimensional internal wave propagation model with rotation effect was deduced, which can be used to simulate the characteristics of internal waves in ... Based on the research of Lynett and Liu, a new horizontal fully two-dimensional internal wave propagation model with rotation effect was deduced, which can be used to simulate the characteristics of internal waves in a horizontal fully two-dimensional plane. By combining the imaging mechanism of Synthetic Aperture Radar(SAR), a simulation procedure was fatherly acquired, which can simulate the propagation characteristics of oceanic internal waves into SAR images. In order to evaluate the validity of the proposed simulation procedure, case studies are performed in South China Sea and results from simulation procedure are analyzed in detail. A very good consistency was found between the simulation results and satellite images. The proposed simulation procedure will be a possible foundation for the quantitative interpretation of internal waves from fully two-dimensional satellite images. 展开更多
关键词 oceanic internal waves imaging simulation Synthetic Aperture Radar (SAR)
原文传递
Comparison of Two Simulation Methods in Electron Crystallography: BW Method and a Modified Direct Product Method of Scattering Matrix
19
作者 Yi Yang Canying Cai Qibin Yang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2017年第2期210-214,共5页
In this paper, a modified direct product method of scattering matrix (DPSM) was presented and the cal- culation formulawas derived as follows: φ(z)=∑n1/n!(Mz)nφ(O)and φ(z+εj)=∑n1/n!(Mεj)nφ(z),... In this paper, a modified direct product method of scattering matrix (DPSM) was presented and the cal- culation formulawas derived as follows: φ(z)=∑n1/n!(Mz)nφ(O)and φ(z+εj)=∑n1/n!(Mεj)nφ(z),whereM is the scattering matrix of which the dimension can be reduced by 'Bethe potential method' drastically and therefore the calculation speed can be increased tremendously without losing accuracy very much. The results calculated with the DPSM method are in almost exact agreement with those calculated with BW method. However, the calculation speed for the modified DPSM method is approximately three times faster than that for the BW method. Furthermore, the DPSM is suitable for computing all types of ma- trices without requiring symmetry or conjugate symmetry. 展开更多
关键词 Electron crystallography image simulation Bethe potential method Matrix diagonalization
原文传递
Adapting Nanotech Research as Nano-Micro Hybrids Approach Biological Complexity,A Review
20
作者 Sascha Vongehr Shaochun Tang Xiangkang Meng 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2016年第5期387-401,共15页
Today's emergence of nano-micro hybrid structures with almost biological complexity is of fundamental interest. Our ability to adapt intelligently to the challenges has ramifications all the way from fundamentally ch... Today's emergence of nano-micro hybrid structures with almost biological complexity is of fundamental interest. Our ability to adapt intelligently to the challenges has ramifications all the way from fundamentally changing research itself, over applications critical to future survival, to posing globally existential dangers. Touching on specific issues such as how complexity relates to the catalytic prowess of multi-metal compounds, we discuss the increasingly urgent issues in nanotechnology also very generally and guided by the motto 'Bio Is Nature's Nanotech'. Technology belongs to macro-evolution; for example integration with artificial intelligence (AI) is inevitable. Darwinian adaptation manifests as integration of complexity, and awareness of this helps in developing adaptable research methods that can find use across a wide range of research. The second half of this work reviews a diverse range of projects which all benefited from 'playful' programming aimed at dealing with complexity. The main purpose of reviewing them is to show how such projects benefit from and fit in with the general, philosophical approach, proving the relevance of the 'big picture' where it is usually disregarded. 展开更多
关键词 Complex hybrid structures Catalysis Macro-evolution Optimization image analysis simulation Statistical analysis Error analysis Critique of technology
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部