Monte Carlo studies of micromegas as a neutron detector and its track reconstruction 被引量:2
1
作者 张毅 张小东 +3 位作者 王文昕 杨贺润 杨正才 胡碧涛 《Chinese Physics C》 SCIE CAS CSCD 2009年第1期42-46,共5页
In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on tim... In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position. The results showed that with this reconstruction method higher spatial resolution was achieved. 展开更多
关键词 simulation neutron detector track reconstruction
原文传递
基于CR39固体核径迹探测器的低能中子剂量测量方法初步研究 被引量:3
2
作者 曹磊 邓君 +6 位作者 兰长林 宋延超 丁晓文 马驰 郭泽钦 郑昀 邱羽桐 《辐射防护》 CAS CSCD 北大核心 2017年第3期174-179,共6页
本文给出了一种采用固体核径迹探测器测量低能(0.5 e V以下能量)中子的双片径迹计数方法,利用蒙特卡罗模拟和实验,统计分析了低能中子引起的探测器单位面积径迹密度。结果显示,采用双片径迹计数方法,实现了CR39对于低能中子的响应,可以... 本文给出了一种采用固体核径迹探测器测量低能(0.5 e V以下能量)中子的双片径迹计数方法,利用蒙特卡罗模拟和实验,统计分析了低能中子引起的探测器单位面积径迹密度。结果显示,采用双片径迹计数方法,实现了CR39对于低能中子的响应,可以对低能中子引起的个人剂量进行估算。应用在中子职业个人剂量监测时,有效甄别了背景径迹的影响,因而降低了测量误差,对减小中子个人剂量监测的测量不确定度也是一个可行的方法。 展开更多
关键词 CR39固体核径迹探测器 低能中子 蒙特卡罗模拟 双片径迹计数
下载PDF