Based on the basic principle of Time-Of-Flight cameras,a novel MATLAB/SIMULINK model is proposed to measure phase delay of a modulated light signal which represents the distance from camera to object. Subsequently,by ...Based on the basic principle of Time-Of-Flight cameras,a novel MATLAB/SIMULINK model is proposed to measure phase delay of a modulated light signal which represents the distance from camera to object. Subsequently,by discussing influence factors of phase measurement,it is found that the integration time,the sampling time,and the aliasing effect have important effect on improving the accuracy of phase measurement. Interestingly,by analyzing different integration time and sampling time, it is found that the best integration time and sampling time are 0.05 ms and 10 ns,respectively. In this case(i.e.,in absence of the aliasing effect),the variation range of the distance error is between 1 mm and 11 mm in the interval of one period. Especially,under the consideration of the aliasing effect,the average value of distance error is half of that in absence of the aliasing effect. This improves the accuracy of the distance measurement greatly.展开更多
In this paper, gas control on EAST in open and closed loop is discussed and its implementation into EASTPCS (plasma control system for the experimental advanced supercon- ducting tokamak) is introduced. Using a mode...In this paper, gas control on EAST in open and closed loop is discussed and its implementation into EASTPCS (plasma control system for the experimental advanced supercon- ducting tokamak) is introduced. Using a model to describe the plasma density response to the gas puff command, a gas simulation server (simserver) using MATLAB simulink tools and real time workshop was built up. Proper operation of the gas control algorithm was verified using this simserver. The simulation results suggested that the gas control can be applied in the next EAST campaign.展开更多
The aim of this paper is to determine the power losses recorded by a PV generator operating under partial shading conditions. These losses are evaluated through two distinct methods. The first method is based on mathe...The aim of this paper is to determine the power losses recorded by a PV generator operating under partial shading conditions. These losses are evaluated through two distinct methods. The first method is based on mathematical modeling, while the second is based on Simulink’s physical model. The losses recorded are considerable and increase as a function of the increase in the percentage of shading up to a limit value where they become constant in the case where an ideal by-pass diode is connected in parallel with the modules. This limit value is non-existent in the case where the bypass diode is not ideal, which in fact corresponds to the real model. However, it emerges that the power losses are minimized in a PV system comprising bypass diodes, in particular in the case where the partial shading is considerable.展开更多
基金National Natural Science Foundation of China(6127404361233010)Hunan Provincial Natural Science Fund for Distinguished Young Scholars(2015JJ1014)
文摘Based on the basic principle of Time-Of-Flight cameras,a novel MATLAB/SIMULINK model is proposed to measure phase delay of a modulated light signal which represents the distance from camera to object. Subsequently,by discussing influence factors of phase measurement,it is found that the integration time,the sampling time,and the aliasing effect have important effect on improving the accuracy of phase measurement. Interestingly,by analyzing different integration time and sampling time, it is found that the best integration time and sampling time are 0.05 ms and 10 ns,respectively. In this case(i.e.,in absence of the aliasing effect),the variation range of the distance error is between 1 mm and 11 mm in the interval of one period. Especially,under the consideration of the aliasing effect,the average value of distance error is half of that in absence of the aliasing effect. This improves the accuracy of the distance measurement greatly.
基金supported by the Key Project of Knowledge Innovation Program of Chinese Academy of Sciences (No. KJCX3.SYW.N4)
文摘In this paper, gas control on EAST in open and closed loop is discussed and its implementation into EASTPCS (plasma control system for the experimental advanced supercon- ducting tokamak) is introduced. Using a model to describe the plasma density response to the gas puff command, a gas simulation server (simserver) using MATLAB simulink tools and real time workshop was built up. Proper operation of the gas control algorithm was verified using this simserver. The simulation results suggested that the gas control can be applied in the next EAST campaign.
文摘The aim of this paper is to determine the power losses recorded by a PV generator operating under partial shading conditions. These losses are evaluated through two distinct methods. The first method is based on mathematical modeling, while the second is based on Simulink’s physical model. The losses recorded are considerable and increase as a function of the increase in the percentage of shading up to a limit value where they become constant in the case where an ideal by-pass diode is connected in parallel with the modules. This limit value is non-existent in the case where the bypass diode is not ideal, which in fact corresponds to the real model. However, it emerges that the power losses are minimized in a PV system comprising bypass diodes, in particular in the case where the partial shading is considerable.