期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Teleportation of an unknown two-atom state using simultaneous interaction of two two-level atoms with cavity field 被引量:2
1
作者 向少华 宋克慧 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第8期488-490,共3页
Proposal for the teleportation of two-atom state is presented. It is based on the simultaneous interaction of two two-level atoms with a single-mode cavity with a filed of n photons. In the proposed scheme, two pairs ... Proposal for the teleportation of two-atom state is presented. It is based on the simultaneous interaction of two two-level atoms with a single-mode cavity with a filed of n photons. In the proposed scheme, two pairs of EPR state are used as quantum channel to teleport an unknown two-atom state. The completed time is greatly reduced and cavity field is not required to be detected are shown to be the distinct features of the presented scheme. 展开更多
关键词 of on for be that into Teleportation of an unknown two-atom state using simultaneous interaction of two two-level atoms with cavity field with
原文传递
Simultaneous measurement of refractive index and temperature using a microring resonator 被引量:1
2
作者 林奈 姜澜 +2 位作者 王素梅 袁雷 陈强华 《Chinese Optics Letters》 SCIE EI CAS CSCD 2012年第5期66-69,共4页
An approach to the simultaneous optical ring resonators is proposed measurement of refractive-index (RI) and theoretically demonstrated. With and temperature changes using a liquid-core silica ring resonator as an e... An approach to the simultaneous optical ring resonators is proposed measurement of refractive-index (RI) and theoretically demonstrated. With and temperature changes using a liquid-core silica ring resonator as an example, two different-order whispering gallery modes (WGMs) might differ in not only RI but also temperature sensitivities. Thus, a second-order sensing matrix should be defined based on these WGMs to determine RI and temperature changes simultaneously. The analysis shows that the RI and temperature detection limits can be achieved on the order of 10.7 RI unit and 10-3 K at a wavelength of approximately 780 nm. 展开更多
关键词 In RI simultaneous measurement of refractive index and temperature using a microring resonator
原文传递
Simultaneous 2D in-plane deformation measurement using electronic speckle pattern interferometry with double phase modulations 被引量:1
3
作者 朱云龙 Julien Vaillant +3 位作者 Guillaume Montay Manuel Fran?ois Yassine Hadjar Aurélien Bruyant 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第7期40-44,共5页
Electronic speckle pattern interferometry(ESPI) and digital speckle pattern interferometry are wellestablished non-contact measurement methods. They have been widely used to carry out precise deformation mapping. Ho... Electronic speckle pattern interferometry(ESPI) and digital speckle pattern interferometry are wellestablished non-contact measurement methods. They have been widely used to carry out precise deformation mapping. However, the simultaneous two-dimensional(2D) or three-dimensional(3D) deformation measurements using ESPI with phase shifting usually involve complicated and slow equipment. In this Letter, we solve these issues by proposing a modified ESPI system based on double phase modulations with only one laser and one camera. In-plane normal and shear strains are obtained with good quality. This system can also be developed to measure 3D deformation, and it has the potential to carry out faster measurements with a highspeed camera. 展开更多
关键词 simultaneous 2D in-plane deformation measurement using electronic speckle pattern interferometry with double phase modulations
原文传递
Simultaneous blood flow and oxygenation measurements using an off-the-shelf spectrometer
4
作者 成明洙 Phuong Minh Mai +1 位作者 李基準 金載官 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第7期60-64,共5页
Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. ... Blood oxygenation and flow are both important parameters in a living body. In this Letter, we introduce a simple configuration to simultaneously measure blood flow and oxygenation using an off-the-shelf spectrometer. With the integration time of 10 ms, flow phantom measurements, a liquid blood phantom test, and an arm cuff occlusion paradigm were performed to validate the feasibility of the system. We expect this proof-of-concept study would be widely adopted by other researchers for acquiring both blood flow and oxygenation changes due to its straightforward configuration and the possibility of multimodal measurement. 展开更多
关键词 simultaneous blood flow and oxygenation measurements using an off-the-shelf spectrometer BFI
原文传递
Simultaneous refractive index and temperature measurements by using dual interference in an all-fiber Mach–Zehnder interferometer
5
作者 闫旭 傅海威 +1 位作者 李辉栋 乔学光 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第3期23-27,共5页
A Fourier analysis applied to the Mach-Zehnder interferometer (MZI) transmission spectrum for simultaneous refractive index (RI) and temperature measurements is proposed and experimentally demonstrated in this Let... A Fourier analysis applied to the Mach-Zehnder interferometer (MZI) transmission spectrum for simultaneous refractive index (RI) and temperature measurements is proposed and experimentally demonstrated in this Letter. In the fast Fourier transform (FFT) spectrum of the MZI transmission spectrum, several frequency components are generally observed, which means that the transmission spectrum of the MZI is formed by the superposition of some dual-mode interference (DMI) spectra, and each frequency component represents different core-cladding interferences. We can select some dominant frequency components in the FFT spectrum of the MZI transmission spectrum to take the inverse FFT (IFFT). Then, the corresponding DMI patterns can be obtained. Due to the shift of the wavelength of these DMI spectra with changes in the environmental parameters, we can use the coefficient matrix of these DMI spectra for multi-parameter sensing. In this Letter, two DMI patterns are separated from the resultant transmission spectrum of the MZI. As the RI and temperature change, the shifts of the two DMI patterns with respect to the RI and temperature will be observed. The sensitivities of the RI and temperature are -137.1806 nm/RIU (RI unit) and 0.0860 nm/℃, and -22.9955 nm/RIU and 0.0610 nm/℃ for the two DMIs. Accordingly, it can be used to simultaneously measure RI and temperature changes. The approach can eliminate the influence of multiple interferences and improve the accuracy of the sensor. 展开更多
关键词 RIU MZI DMI simultaneous refractive index and temperature measurements by using dual interference in an all-fiber Mach Zehnder interferometer
原文传递
Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
6
作者 Utkarsh Sharma Jin U.Kang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期910-912,共3页
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with... The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously. 展开更多
关键词 simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
原文传递
Optimization of two-factor(pH and ion concentration)simultaneous selection in HPLC using a statistical method
7
作者 WANG,Qin-Sun GAO,Ru-Yu YAN,Bing-Wen National Laboratory of Elemento-Organic Chemistry,Nankai University,Tianjin 300071 《Chinese Journal of Chemistry》 SCIE CAS CSCD 1992年第2期143-149,共0页
A computer-assisted method is presented for simultaneous optimization of pH and ion con- centration selection for the optimal separation in reversed-phase HPLC.The method is based on a polynomial estimation from nine ... A computer-assisted method is presented for simultaneous optimization of pH and ion con- centration selection for the optimal separation in reversed-phase HPLC.The method is based on a polynomial estimation from nine preliminary experiments according to two-factor rectangular design. This is followed by a two-dimension computer scanning technique.Resolution is used as the selection criterion.Good agreement was obtained between predicted data and experimental results. 展开更多
关键词 pH and ion concentration)simultaneous selection in HPLC using a statistical method Optimization of two-factor HPLC
全文增补中
上一页 1 下一页 到第
使用帮助 返回顶部