objective: To introduce the development of a portable multi-parameter monitoring system. Methods: Using signal detecting and data processing techniques, this monitor with a graphic liquid crystal display (LCD) and a s...objective: To introduce the development of a portable multi-parameter monitoring system. Methods: Using signal detecting and data processing techniques, this monitor with a graphic liquid crystal display (LCD) and a single-chip microprocessor 8Xc196Kc can dynamically measure electrocardiogram(ECG), breath wave, blood pressure (BP), breath frequency (BF), heart rate (HR) and body temperature (BT) in real-time. Results: This monitor can dynamically display the ECG, breath wave and other parameters in real time. It can also provide a 24h trend graph for each measured parameter and exchange data, through the serial communication interface (RS232), with the PC or hand-held PC (HPC). Conclusions: This portable monitoring system has a man-machine interface friendly. It is capable of performing continuous monitoring and also used as terminal of a central monitoring system or a tele-monitoring system.展开更多
This peper proposes a new type of dynamic ECG (Holier) monitoring andrecording system based on technology or computer controlling and high storage capacitydynamic RAM (DRAM). The system realizes the monitoring and rec...This peper proposes a new type of dynamic ECG (Holier) monitoring andrecording system based on technology or computer controlling and high storage capacitydynamic RAM (DRAM). The system realizes the monitoring and recording ECG signalscontinuously up to 24 hours with the double error criterion ECG data compression algorithm or time error and amplitude error[1], adaptive algorithm for detecting andanalysing the oRS complexes[2] and the technology of high storage capacity DRAM. Itsadvantages are high storage Capacity (4MB), low power dissipation (less titan 30mA).展开更多
This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil c...This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission.展开更多
基金This work was supported by National 863 plan item of China( No:863 -3 0 6-ZD-0 50 2 )
文摘objective: To introduce the development of a portable multi-parameter monitoring system. Methods: Using signal detecting and data processing techniques, this monitor with a graphic liquid crystal display (LCD) and a single-chip microprocessor 8Xc196Kc can dynamically measure electrocardiogram(ECG), breath wave, blood pressure (BP), breath frequency (BF), heart rate (HR) and body temperature (BT) in real-time. Results: This monitor can dynamically display the ECG, breath wave and other parameters in real time. It can also provide a 24h trend graph for each measured parameter and exchange data, through the serial communication interface (RS232), with the PC or hand-held PC (HPC). Conclusions: This portable monitoring system has a man-machine interface friendly. It is capable of performing continuous monitoring and also used as terminal of a central monitoring system or a tele-monitoring system.
文摘This peper proposes a new type of dynamic ECG (Holier) monitoring andrecording system based on technology or computer controlling and high storage capacitydynamic RAM (DRAM). The system realizes the monitoring and recording ECG signalscontinuously up to 24 hours with the double error criterion ECG data compression algorithm or time error and amplitude error[1], adaptive algorithm for detecting andanalysing the oRS complexes[2] and the technology of high storage capacity DRAM. Itsadvantages are high storage Capacity (4MB), low power dissipation (less titan 30mA).
文摘This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission.