BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal...BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal clavicle fractures treated utilizing an anterior inferior plate with a single screw placed in the distal,in anticipation of providing a better surgical approach to distal clavicle fracture treatment.Two patients were admitted to the hospital after trauma with a diagnosis of distal clavicle fracture,and were admitted to the hospital for internal fixation of clavicle fracture by incision and reduction,with good postoperative functional recovery.CONCLUSION With solid postoperative fixation and satisfactory prognostic functional recovery,this technique has been shown to be simple,easy to perform and effective.展开更多
A new theory and method that differs from the tradition-al single plated weft - knitting theory and method hasbeen expounded after theoretical analyzing and experi-mental proving. If the new method is used when platin...A new theory and method that differs from the tradition-al single plated weft - knitting theory and method hasbeen expounded after theoretical analyzing and experi-mental proving. If the new method is used when platingstitch is knitted on large diameter weft knitting machine,the thorny problem of long standing that ground yarn iseasy to appear on the face side of fabric is solved. Thenew method, i.e, the production of physical ability oftraining uniform for serviceman has been used.展开更多
Background: complex proximal tibial fractures (Types V & VI of Schautzker classification) are the major problems in orthopedic surgery and associated with high complication rates. There are many alternatives in tr...Background: complex proximal tibial fractures (Types V & VI of Schautzker classification) are the major problems in orthopedic surgery and associated with high complication rates. There are many alternatives in treatment of these fractures. Aim: to evaluate the results of double plating with single anterior incision in complex proximal tibial fractures (Types V& VI of Schautzker classification).Methods and Materials: 22 patients (16 males and 6 females) with Types V and VI of Schautzker classification of proximal tibial fractures (14 cases were Type V and 8 cases were Type VI) were treated by double plating with single anterior incision method between May 2006 and May 2011. The bony and functional outcome was evaluated according to Knee Society Score. Results: According to Knee Society Score, the results were as follows: excellent in 19 patients (86.4%), good in 2 patients (9.1%), fair in 1 patient (4/5%), and poor in no patient (0%).Conclusion: the double plate fixation with single anterior incision is the best, effective and simple procedure in treatment of complex proximal tibial fractures (Types V and VI of Schautzker classification).展开更多
In this paper the significance analysis has been made of the factors influencing the yarn appearing of single plated weft-knit fabrics knitted on large diameter machine by a mathematical statistical method. By means o...In this paper the significance analysis has been made of the factors influencing the yarn appearing of single plated weft-knit fabrics knitted on large diameter machine by a mathematical statistical method. By means of orthogonal test and variance analysis, it is known that the feeding tension is the significant factor influencing the yarn appearance and the ground yarn tension should be larger than the face yarn tension. Through comparison, it is also known that the drawing off force should be regulated suitably, the carrier should be near the first closed needle, and the sinker should be out late slightly.展开更多
This work gives an analytical theory of the signal-to-thermal-noise ratio (SNR) of classical Hall plates with four contacts at small magnetic field. In contrast to previous works, the symmetry of the Hall plates is re...This work gives an analytical theory of the signal-to-thermal-noise ratio (SNR) of classical Hall plates with four contacts at small magnetic field. In contrast to previous works, the symmetry of the Hall plates is reduced to only a single mirror axis, whereby the average of potentials of the two output contacts off this mirror axis differs from the average of potentials at the two supply contacts on the mirror axis, i.e. the output common mode differs from 50%. Surprisingly, at fixed power dissipated in the Hall plate, the maximum achievable SNR is only 9% smaller for output common modes of 30% and 70% when compared to the overall optimum at output common modes of 50%. The theory is applied to Vertical Hall effect devices with three contacts on the top surface and one contact being the buried layer in a silicon BiCMOS process. Geometries are found with large contacts and only a moderate loss in SNR.展开更多
A novel tunable comb filter composed of a single-mode/multimode/polarization-maintaining-fiber-based Sagnac fiber loop is proposed and experimentally demonstrated. The filter tunability is achieved by rotating the pol...A novel tunable comb filter composed of a single-mode/multimode/polarization-maintaining-fiber-based Sagnac fiber loop is proposed and experimentally demonstrated. The filter tunability is achieved by rotating the polarization controller. The spectral shift is dependent on rotation direction and the position of the polarization controller. In addition, the adjustable range achieved by rotating the half-wave-plate polarization controller is twice higher than that of the quarter-wave-plate one.展开更多
基金Supported by Science Foundation Project of Baotou Medical College,No.BYJJ-YF-2018006.
文摘BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal clavicle fractures treated utilizing an anterior inferior plate with a single screw placed in the distal,in anticipation of providing a better surgical approach to distal clavicle fracture treatment.Two patients were admitted to the hospital after trauma with a diagnosis of distal clavicle fracture,and were admitted to the hospital for internal fixation of clavicle fracture by incision and reduction,with good postoperative functional recovery.CONCLUSION With solid postoperative fixation and satisfactory prognostic functional recovery,this technique has been shown to be simple,easy to perform and effective.
文摘A new theory and method that differs from the tradition-al single plated weft - knitting theory and method hasbeen expounded after theoretical analyzing and experi-mental proving. If the new method is used when platingstitch is knitted on large diameter weft knitting machine,the thorny problem of long standing that ground yarn iseasy to appear on the face side of fabric is solved. Thenew method, i.e, the production of physical ability oftraining uniform for serviceman has been used.
文摘Background: complex proximal tibial fractures (Types V & VI of Schautzker classification) are the major problems in orthopedic surgery and associated with high complication rates. There are many alternatives in treatment of these fractures. Aim: to evaluate the results of double plating with single anterior incision in complex proximal tibial fractures (Types V& VI of Schautzker classification).Methods and Materials: 22 patients (16 males and 6 females) with Types V and VI of Schautzker classification of proximal tibial fractures (14 cases were Type V and 8 cases were Type VI) were treated by double plating with single anterior incision method between May 2006 and May 2011. The bony and functional outcome was evaluated according to Knee Society Score. Results: According to Knee Society Score, the results were as follows: excellent in 19 patients (86.4%), good in 2 patients (9.1%), fair in 1 patient (4/5%), and poor in no patient (0%).Conclusion: the double plate fixation with single anterior incision is the best, effective and simple procedure in treatment of complex proximal tibial fractures (Types V and VI of Schautzker classification).
文摘In this paper the significance analysis has been made of the factors influencing the yarn appearing of single plated weft-knit fabrics knitted on large diameter machine by a mathematical statistical method. By means of orthogonal test and variance analysis, it is known that the feeding tension is the significant factor influencing the yarn appearance and the ground yarn tension should be larger than the face yarn tension. Through comparison, it is also known that the drawing off force should be regulated suitably, the carrier should be near the first closed needle, and the sinker should be out late slightly.
文摘This work gives an analytical theory of the signal-to-thermal-noise ratio (SNR) of classical Hall plates with four contacts at small magnetic field. In contrast to previous works, the symmetry of the Hall plates is reduced to only a single mirror axis, whereby the average of potentials of the two output contacts off this mirror axis differs from the average of potentials at the two supply contacts on the mirror axis, i.e. the output common mode differs from 50%. Surprisingly, at fixed power dissipated in the Hall plate, the maximum achievable SNR is only 9% smaller for output common modes of 30% and 70% when compared to the overall optimum at output common modes of 50%. The theory is applied to Vertical Hall effect devices with three contacts on the top surface and one contact being the buried layer in a silicon BiCMOS process. Geometries are found with large contacts and only a moderate loss in SNR.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11274181,10974100,and 10674075)the Tianjin Key Program of Application Foundations and Future Technology Research Project,China (Grant No. 10JCZDJC24300)the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20120031110033)
文摘A novel tunable comb filter composed of a single-mode/multimode/polarization-maintaining-fiber-based Sagnac fiber loop is proposed and experimentally demonstrated. The filter tunability is achieved by rotating the polarization controller. The spectral shift is dependent on rotation direction and the position of the polarization controller. In addition, the adjustable range achieved by rotating the half-wave-plate polarization controller is twice higher than that of the quarter-wave-plate one.