Theoretical analysis and wind tunnel tests were carried out to study wind-induced intemal pressure response for the structure with single windward opening and background leakage. Its goveming differential equation was...Theoretical analysis and wind tunnel tests were carried out to study wind-induced intemal pressure response for the structure with single windward opening and background leakage. Its goveming differential equation was derived by the Bemoulli equation in an unsteady-isentropic form. Numerical examples were provided to study the additive damping caused by background leakage in laminar and turbulent flow, and the influence of background leakage on fluctuating internal pressure response was quantized. A series of models for low-rise building with various opening ratios and background leakage were designed and wind tunnel tests were conducted. It is shown that the fluctuating intemal pressure reduces when the background leakage are considered and that the effect of background leakage can be predicted accurately by the governing differential equation deduced in this paper.展开更多
A frequency domain method for estimating wind-induced fluctuating internal pressure of structure with single windward opening is presented in this paper and wind tunnel tests were carried out to verify the theory. The...A frequency domain method for estimating wind-induced fluctuating internal pressure of structure with single windward opening is presented in this paper and wind tunnel tests were carried out to verify the theory. The nonlinear differential equation of internal pressure dynamics and iteration algorithm were applied to calculate fluctuating internal pressure and time domain analysis was used to verify the accuracy of the proposed method. A simplified estimation method is also provided and its scope of application is clarified. The mechanism of internal pressure fluctuation is obtained by using the proposed method in the frequency domain and a new equivalent opening ratio is defined to evaluate internal pressure fluctuation. A series of low-rise building models with various openings and internal volumes were designed for wind tunnel tests with results agreeing well with analytical results. It is shown that the proposed frequency domain method based on Gaussian distribution of internal pressure fluctuations can be applied to predict the RMS internal pressure coefficient with adequate accuracy for any opening dimensions, while the simplified method can only be used for structure with single dominant opening. Helmholtz resonance is likely to occur when the equivalent opening ratio is adequately high, and controlling individual opening dimension is an effective strategy for avoiding Helmholtz resonance in engineering.展开更多
Thoracic Surgery is a continuous evolving specialty. In the past, thoracic surgeons had to make large incisions in order to operate any pathology inside the chest. This often meant big, painful and ugly scars and long...Thoracic Surgery is a continuous evolving specialty. In the past, thoracic surgeons had to make large incisions in order to operate any pathology inside the chest. This often meant big, painful and ugly scars and long recovery times after surgery. But he history of thoracic surgery changed since the begining of video-assisted thoracoscoDic surgery (VATg3展开更多
基金Project (No. 50578144) supported by the National Natural ScienceFoundation of China
文摘Theoretical analysis and wind tunnel tests were carried out to study wind-induced intemal pressure response for the structure with single windward opening and background leakage. Its goveming differential equation was derived by the Bemoulli equation in an unsteady-isentropic form. Numerical examples were provided to study the additive damping caused by background leakage in laminar and turbulent flow, and the influence of background leakage on fluctuating internal pressure response was quantized. A series of models for low-rise building with various opening ratios and background leakage were designed and wind tunnel tests were conducted. It is shown that the fluctuating intemal pressure reduces when the background leakage are considered and that the effect of background leakage can be predicted accurately by the governing differential equation deduced in this paper.
基金Project (No. 50378085) supported by the National Natural ScienceFoundation of China
文摘A frequency domain method for estimating wind-induced fluctuating internal pressure of structure with single windward opening is presented in this paper and wind tunnel tests were carried out to verify the theory. The nonlinear differential equation of internal pressure dynamics and iteration algorithm were applied to calculate fluctuating internal pressure and time domain analysis was used to verify the accuracy of the proposed method. A simplified estimation method is also provided and its scope of application is clarified. The mechanism of internal pressure fluctuation is obtained by using the proposed method in the frequency domain and a new equivalent opening ratio is defined to evaluate internal pressure fluctuation. A series of low-rise building models with various openings and internal volumes were designed for wind tunnel tests with results agreeing well with analytical results. It is shown that the proposed frequency domain method based on Gaussian distribution of internal pressure fluctuations can be applied to predict the RMS internal pressure coefficient with adequate accuracy for any opening dimensions, while the simplified method can only be used for structure with single dominant opening. Helmholtz resonance is likely to occur when the equivalent opening ratio is adequately high, and controlling individual opening dimension is an effective strategy for avoiding Helmholtz resonance in engineering.
文摘Thoracic Surgery is a continuous evolving specialty. In the past, thoracic surgeons had to make large incisions in order to operate any pathology inside the chest. This often meant big, painful and ugly scars and long recovery times after surgery. But he history of thoracic surgery changed since the begining of video-assisted thoracoscoDic surgery (VATg3