期刊文献+
共找到2,063篇文章
< 1 2 104 >
每页显示 20 50 100
Technetium-99m-methylene diphosphonate single photon emission computed tomography/computed tomography combined with prostate-specific antigen/free prostate-specific antigen ratio for bone metastasis of prostate cancer
1
作者 Jian He Yi-Pu Zhong Shuang Zhang 《World Journal of Clinical Cases》 SCIE 2024年第20期4082-4090,共9页
BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To inves... BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To investigate the diagnostic value of technetium-99m-methylene diphosphonate(99mTc-MDP)single photon emission computed tomography(SPECT)/CT imaging combined with the serum prostate-specific antigen(PSA)/free PSA ratio for PC bone metastasis(PCBM).METHODS One hundred patients with PC who visited the Hospital of Chengdu University of Traditional Chinese Medicine from January 2020 to January 2022 were recruited as the experimental(Exp)group,while 30 patients with benign prostatic lesions(BPLs)were recruited as the control(Ctrl)group.All patients underwent 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA testing.The SPECT/CT imaging results and serum PSA/fPSA ratios of patients were analyzed to evaluate their diagnostic values for PCBM.RESULTS The difference in general information of the patients was not obvious,showing comparability.The two methods showed no visible differences in negative predictive value and sensitivity for patients with PCBM,but had great differences in positive predictive value and specificity(P<0.05).The PSA/fPSA ratio of patients with PC in the Exp group was lower than those with BPLs,and patients with PCBM had a much lower PSA/fPSA ratio than those without PC(P<0.05).The results confirmed that the combined use of 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA ratio achieved a detection rate of 95%for PCBM.CONCLUSION The combination of 99mTc-MDP SPECT/CT and PSA/fPSA ratio is accurate and reliable for the diagnosis of PCBM,which provides an important reference for clinical practice. 展开更多
关键词 Matrix metalloproteinase 9 single photon emission computed tomography Prostate-specific antigen to free prostate-specific antigen ratio Prostate cancer Bone metastasis
下载PDF
Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography:A case report
2
作者 Chang-Jiang Liu Hua-Jun Yang +1 位作者 Yan-Chun Peng De-Yu Huang 《World Journal of Clinical Cases》 SCIE 2023年第12期2825-2831,共7页
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod... BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs. 展开更多
关键词 Neuroendocrine tumors PANCREAS Tc-99m-Methoxy-2-isobutylisonitrile single photon emission computed tomography X-ray computed tomography Case report
下载PDF
Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography 被引量:2
3
作者 Yong Huang Yangjia Lu +5 位作者 Ganlong Li Xinsheng Lai Hong Zhang Chunzhi Tang JunjunYang Gustav Wik 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第6期428-434,共7页
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th... The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint. 展开更多
关键词 acupoint specificity Waiguan (SJ 5) NEEDLING sham needling sham point single-photon emission computed tomography
下载PDF
Dopamine transporter distribution in patients with Parkinson disease of different stages detected using single-photon emission computed tomography brain imaging
4
作者 Jiwu Zhang Lijuan Zhu Jianqiang Du Bo Liu 《Neural Regeneration Research》 SCIE CAS CSCD 2007年第1期18-21,共4页
BACKGROUND: Literatures have reported that the density changes of dopamine transporter is negatively correlated with the severity degree and grading of disease condition of Parkinson disease (PD). However, the dist... BACKGROUND: Literatures have reported that the density changes of dopamine transporter is negatively correlated with the severity degree and grading of disease condition of Parkinson disease (PD). However, the distribution ofdopamine transporter in each nucleus of corpora striatum at each period is still unclear. OBJECTIVE: To observe the radioactive uptake distribution of dopamine transporter in bilateral corpora striata of patients with different stages of PD using single photon emission computed tomography (SPECT), and make a comparison with healthy controls. DESIGN: Case-control analysis. SETTING: Department of Imageology, Second Hospital Affiliated to Guangzhou University of Chinese Medicine. PARTICIPANTS: Thirty patients with PD admitted to Second Hospital Affiliated to Guangzhou University of Traditional Chinese Medicine between January and December 2005 were recruited. The involved patients, 19 male and 11 female, were aged from 36 to 80 years and with disease course of 2.5 months to 10 years. They all met the clinical diagnosis criteria of Britain Parkinson's disease Association Think Tank; Following Hoehn-Yahr grading: grade Ⅰ : unilateral morbidity; grade Ⅱ: bilateral morbidity, but without balance disorder; grade Ⅲ: bilateral morbidity, accompanied with early posture balance disorder; grade Ⅳ: severe morbidity, needs more help; grade V : without help, only in bed or wheelchair. There were 11 patients with mild PD (grade Ⅰ - Ⅱ ), 9 patients with moderate PD (grade Ⅲ) and 10 patients with advanced PD (grade Ⅳ - Ⅴ ). Meanwhile, 6 healthy persons were selected as normal controls. Informed consents were obtained from all the subjects. METHODS: Twenty-four hours after withdrawal of PD drugs, 30 patients with PD and 6 healthy controls took kalium perchloricum 400 mg orally. After lying down for 30 minutes, all the subjects were intravenously injected with 740 MBq 99Tc m-TRODAT-1 (Jiangsu Institute of Atomic Medicine, Batch No. 20040310) at elbow part. Following injection, image was collected using scanner for single photon emission computed tomography (ADAC Company, USA). Matrix was 64 × 64, each detecting head revolved 180 ° , 1 frame/60 s. Sixty-four frames were collected with double detecting heads, 50 K/frame. Faultages with clearest image of corpora striatum were selected. Regions of interest (ROI) of caudate nucleus, anterior and posterior putamen and thalamic region in bilateral corpora striata were radioactively counted, and mean value of radioactive counting of ROI was used as the mean value ofpixel in each region of bilateral corpora striata. MAIN OUTCOME MEASURES: Comparison of radioactive uptake in each region of brain between healthy persons and patients with PD. RESULTS: Thirty patients with PD and six healthy persons who received body examination participated in the final result. Comparison of radioactive uptake in each region between healthy persons and patients with PD: ①In the healthy persons, high-density radioactive uptake was found in bilateral corpora striata; Structures of caudate nucleus, anterior and posterior putamen, and thalamus were clear with eudipleural radioactive distribution, and the background of peripheral brain tissue was very low. ②Radioactive intakes in opposite anterior and posterior putamen of patients with mild PD were significantly inferior to those in homolateral ones(70.45±3.35, 87.64±2.65, t =15.82, P 〈 0.05). Structures of bilateral caudate nucleus and thalamus were clear with eudipleural radioactive distribution (P 〉 0.05). ③Radioactive intakes in anterior and posterior putamen and thalamus of patients with moderate PD were significantly reduced as compared with healthy persons. There were significant differences in mean radioactive counting of ROI between patients with PD and healthy persons (t =5.20, P 〈 0.05: t =3.95, P 〈 0.05); The structure of opposite caudate nucleus was not very clear, radioactive distribution of opposite caudate nucleus was significantly reduced as compared with homolateral one (81.11±4.25, 104.56±3.64, t = 14.65, P 〈 0.05). ④As for patients with advanced PD, the structure of bilateral corpora striata was not clear, radioactive intake was significantly reduced and peripheral background was heightened, even higher than the distribution of the whole corpora striatum. CONCLUSION: SPECT DAT imaging of brain can show the distribution of radioactive uptake in each region of bilateral corpora striata of patients with different stages of PD, which is helpful to diagnose and evaluate the severity of PD. 展开更多
关键词 Parkinson disease DOPAMINE tomography emission-computed single-photon
下载PDF
Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography 被引量:4
5
作者 Ka-Kit Wong Arpit Gandhi +3 位作者 Benjamin L Viglianti Lorraine M Fig Domenico Rubello Milton D Gross 《World Journal of Radiology》 CAS 2016年第6期635-655,共21页
AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches u... AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches using the terms: "SPECT/CT"; "functional anatomic mapping"; "transmission emission tomography"; "parathyroid adenoma"; "thyroid cancer"; "neuroendocrine tumor"; "adrenal"; "pheochromocytoma"; "paraganglioma"; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts(case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology.RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the biodistribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for ^(99m)Tc-sestamibi parathyroid scintigraphy and ^(99m)Tc-pertechnetate thyroid scintigraphy, ^(123)I- or ^(131)I-radioiodine for staging of differentiated thyroid carcinoma, ^(111)In- and ^(99m)Tclabeled somatostatin receptor analogues for detection of neuroendocrine tumors, ^(131)I-norcholesterol(NP-59) scans for assessment of adrenal cortical hyperfunction, and ^(123)I- or ^(131)I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma.CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to improved diagnostic accuracy and meaningful impact on patient care. 展开更多
关键词 Parathyroid adenoma Neuroendocrine tumor single photon emission COMPUTED tomography/ COMPUTED tomography single photon emission COMPUTED tomography-computed tomography Thyroid cancer Pheochromocytoma PARAGANGLIOMA
下载PDF
Quantification of Tc-99m-ethyl cysteinate dimer brain single photon emission computed tomography images using statistical probabilistic brain atlas in depressive end-stage renal disease patients:Correlation with disease severity and symptom factors 被引量:1
6
作者 Heeyoung Kim In Joo Kim +3 位作者 Seong-Jang Kim Sang Heon Song Kyoungjune Pak Keunyoung Kim 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第27期2151-2159,共9页
This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the r... This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the relationship between symptom clusters, disease severity, and cerebral blood flow. Twenty-seven patients (16 males, 11 females) with stages 4 and 5 end-stage renal disease were enrolled, along with 25 healthy controls. All patients underwent depressive mood assessment and brain single photon emission computed tomography. The statistical probabilistic anatomical map images were used to calculate the brain single photon emission computed tomography counts. Asymmetric index was acquired and Pearson correlation analysis was performed to analyze the correlation between symptom factors, severity, and regional cerebral blood flow. The depression factors of the Hamilton Depression Rating Scale showed a negative correlation with cerebral blood flow in the left amygdale. The insomnia factor showed negative correlations with cerebral blood flow in the left amygdala, right superior frontal gyrus, right middle frontal gyrus, and left middle frontal gyrus. The anxiety factor showed a positive correlation with cerebral glucose metabolism in the cerebellar vermis and a negative correlation with cerebral glucose metabolism in the left globus pailidus, right inferior frontal gyrus, both temporal poles, and left parahippocampus. The overall depression severity (total scores of Hamilton Depression Rating Scale) was negatively correlated with the statistical probabilistic anatomical map results in the left amygdala and right inferior frontal gyrus. In conclusion, our results demonstrated that the disease severity and extent of cerebral blood flow quantified by a probabilistic brain atlas was related to various brain areas in terms of the overall severity and symptom factors in end-stage renal disease patients. 展开更多
关键词 single photon emission computed tomography end-stage renal disease depression statisticalprobabilistic brain atlas disease severity cerebral blood flow SYMPTOM BRAIN neural regeneration
下载PDF
Three-dimensional stereotactic surface projection in the statistical analysis of single photon emission computed tomography data for distinguishing between Alzheimer's disease and depression 被引量:1
7
作者 Eiji Kirino 《World Journal of Psychiatry》 SCIE 2017年第2期121-127,共7页
AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHO... AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHODS We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following:(1) the Minimal Mental State Examination;(2) the Hamilton Rating Scale for Depression;(3) Clinical Global Impression-Severity scale(CGI-S); and(4) SPECT imaging with 3D-SSP.RESULTS The MMSE scores correlated significantly with the maximum Z-scores of AD-associated regions. CGI-S scores correlated significantly with the maximum Z-scores of depression-associated regions. Factor analysis identified three significant factors. Of these, Factor 1 could be interpreted as favouring a tendency for AD, Factor 2 as favouring a tendency for pseudo-dementia, and Factor 3 as favouring a depressive tendency.CONCLUSION We investigated whether these patients could be categorized as types: Type A(true AD), Type B(pseudodementia), Type C(occult AD), and Type D(true depression). The factor scores in factor analysis supported the validity of this classification. Our results suggest that SPECT with 3D-SSP is highly useful for distinguishing between depression and depressed mood in the early stage of AD. 展开更多
关键词 Alzheimer’s disease THREE-DIMENSIONAL STEREOTACTIC surface projection single photon emission COMPUTED tomography Pseudo-dementia DEPRESSION
下载PDF
Same day yttrium-90 radioembolization with single photon emission computed tomography/computed tomography: An opportunity to improve care during the COVID-19 pandemic and beyond 被引量:1
8
作者 Mohammad Elsayed Mohammad Loya +9 位作者 James Galt David M Schuster Zachary L Bercu Janice Newsome David Brandon Sonia Benenati Keywan Behbahani Richard Duszak Ila Sethi Nima Kokabi 《World Journal of Gastrointestinal Oncology》 SCIE 2021年第5期440-452,共13页
BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical chal... BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19,thus improving patient access.AIM To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography(SPECT/CT)in order to optimize therapy.METHODS All patients were selected for Y-90 RE through a multidisciplinary tumor board,and were screened and tested for COVID-19 infection per institutional protocol.A same day procedure was developed,consisting of angiography,imaging,and Y-90 resin particle delivery.Routine SPECT/CT after technetium-99m macroaggregated albumin(Tc-99m MAA)administration was performed for assessment of arterial supply,personalized dosimetry,and extrahepatic activity.Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery,by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles.RESULTS A total of 14 patients underwent same day Y-90 RE between March and June 2020.Mean lung shunt fraction was 6.13%(range 3.5%-13.1%).Y-90 RE was performed for a single lesion in 7 patients,while the remaining 7 patients had treatment of multifocal lesions.The largest lesion measured 8.3 cm.All patients tolerated the procedure well and were discharged the same day.CONCLUSION Same day Y-90 RE with resin-based microspheres is feasible,and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond.We recommend consideration of SPECT/CT,especially among patients with complex malignancies,for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE. 展开更多
关键词 Yttrium-90 radioembolization Same day Selective internal radiotherapy Transarterial radioembolization single photon emission computed tomography/computed tomography Dosimetry COVID-19
下载PDF
Deep brain stimulation of the subthalamic nucleus treats Parkinson's disease through enhancing metabolic activity of the corpus striatum Verification by single photon emission computed tomography and positron emission tomography
9
作者 Yiqun Cao Xiaoping Zhou +2 位作者 Zhifeng Zhang Xiaowu Hu Xiufeng Jiang 《Neural Regeneration Research》 SCIE CAS CSCD 2010年第6期405-410,共6页
BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopami... BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopamine levels or metabolic activity of the corpus striatum. OBJECTIVE: To validate the effects of STN DBS on dopamine metabolism and glucose metabolism in the corpus striatum of hemiparkinsonian monkeys using single photon emission computed tomography (SPECT) and position emission tomography (PET). DESIGN, TIME AND SET'rING: A controlled animal study was performed at the Neurosurgery Laboratory, Changhai Hospital of the Second Military Medical University of Chinese PLA between January 2004 and December 2007. METHODS: Hemiparkinsonism was induced in adult Rhesus Macaque monkeys, which exhibit similar characteristics of PD in humans, through unilateral internal carotid artery infusion of 1-methy-4-phenyl-1, 2, 3, 6-tetrahydropyrindine. Following model establishment, stimulation electrodes were implanted in the right STN, and chronic high-frequency stimulation (60 μs pulse width, 130 Hz frequency, and 1.5-2.0 V pressure) was performed. MAIN OUTCOME MEASURES: The changes in dopamine transporter (DAT), D2 receptor (D2R), and glucose metabolism in the corpus striatum following STN DBS were observed using SPECT and PET. RESULTS: SPECT examination showed that DAT specific binding in the right corpus striatum was increased at 3 months after DBS compared with prior to stimulation, and D2R specific binding in the right corpus striatum gradually decreased near levels on the left (non-electrode-implanted) side within 3 months after DBS. PET examination showed that the glucose metabolism in the right corpus striatum was markedly increased at 3 months after effective DBS. Hemiparkinsonism monkeys showed improved left limb rigidity, increased activities, and stable gait under chronic high-frequency stimulation. CONCLUSION: STN DBS increased striatal DAT, decreased D2R, and enhanced glucose metabolism, suggesting that chronic, high-frequency STN stimulation enhanced the metabolic activity of the corpus striatum, a mechanism for improving the PD symptoms of hemiparkinsonian monkeys. 展开更多
关键词 subthalamic nucleus deep brain stimulation Parkinson's disease MONKEY single photon emission computed tomography positron emission tomography neural regeneration
下载PDF
PET image reconstruction with a system matrix containing point spread function derived from single photon incidence response 被引量:1
10
作者 樊馨 王海鹏 +8 位作者 贠明凯 孙校丽 曹学香 刘双全 柴培 李道武 刘宝东 王璐 魏龙 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期542-550,共9页
A point spread function(PSF) for the blurring component in positron emission tomography(PET) is studied. The PSF matrix is derived from the single photon incidence response function. A statistical iterative recons... A point spread function(PSF) for the blurring component in positron emission tomography(PET) is studied. The PSF matrix is derived from the single photon incidence response function. A statistical iterative reconstruction(IR) method based on the system matrix containing the PSF is developed. More specifically, the gamma photon incidence upon a crystal array is simulated by Monte Carlo(MC) simulation, and then the single photon incidence response functions are calculated. Subsequently, the single photon incidence response functions are used to compute the coincidence blurring factor according to the physical process of PET coincidence detection. Through weighting the ordinary system matrix response by the coincidence blurring factors, the IR system matrix containing the PSF is finally established. By using this system matrix, the image is reconstructed by an ordered subset expectation maximization(OSEM) algorithm. The experimental results show that the proposed system matrix can substantially improve the image radial resolution, contrast,and noise property. Furthermore, the simulated single gamma-ray incidence response function depends only on the crystal configuration, so the method could be extended to any PET scanner with the same detector crystal configuration. 展开更多
关键词 point spread function single photon incidence system matrix positron emission tomography
下载PDF
应用瑞加诺生负荷D-SPECT评价定量血流分数在经皮冠状动脉介入治疗中的作用 被引量:2
11
作者 李柳 李晓燕 +3 位作者 高志超 郑庆厚 赵甫刚 王硕 《西安交通大学学报(医学版)》 CAS CSCD 北大核心 2024年第3期443-448,共6页
目的应用瑞加诺生负荷动态单光子发射计算机断层扫描(dynamic single-photon emission computed tomography,D-SPECT)评价定量血流分数(quantitative flow ratio,QFR)在经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)... 目的应用瑞加诺生负荷动态单光子发射计算机断层扫描(dynamic single-photon emission computed tomography,D-SPECT)评价定量血流分数(quantitative flow ratio,QFR)在经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)中的作用。方法选择2021年6月31日至2023年6月31日在河北医科大学第一医院心内科住院行择期PCI术的200例不稳定型心绞痛患者,年龄(57.56±8.23)岁,按照随机数字表法分为常规组(n=100)和QFR组(n=100),试验采用双盲法进行。常规组根据医师经验行PCI术治疗,QFR组根据QFR测定结果行PCI治疗。所有入选患者术前及PCI术后7 d,应用瑞加诺生负荷D-SPECT,分别采集短轴、垂直长轴、水平长轴的图像,计算心肌17节段分布下心肌灌注总积分、心肌缺血总节段数情况。结果PCI术前两组患者心肌缺血节段数(7.59±3.14 vs.7.48±3.36,P=0.811)、心肌灌注总积分(15.87±7.61 vs.15.63±5.97,P=0.860)差异无统计学意义,QFR组PCI术后7 d的心肌缺血节段数(5.58±3.36 vs.6.51±2.14,P=0.020)和心肌灌注总积分(10.55±4.41 vs.12.96±6.50,P=0.002)显著优于常规组(P<0.05)。结论应用QFR指导PCI可以更好改善患者心肌缺血程度。 展开更多
关键词 瑞加诺生 动态单光子发射计算机断层扫描(D-SPECT) 经皮冠状动脉介入治疗(PCI) 定量血流分数(QFR)
下载PDF
生长抑素受体显像术前定位诊断导致肿瘤诱发低磷骨软化症的原发肿瘤病灶
12
作者 孙珂 李彦鹏 +4 位作者 刘小婷 王冉 蔺旭阳 李龙吉 韩星敏 《中国医学影像技术》 CSCD 北大核心 2024年第1期143-145,共3页
肿瘤诱发低磷骨软化症(tumor induced osteomalacia, TIO)为间叶源性肿瘤所致低磷骨软化症,多表现为进行性骨痛、骨质疏松、行走困难及活动受限甚至多发骨折,严重影响患者生活质量。手术切除原发灶为治疗TIO的有效方法,但间叶源性肿瘤... 肿瘤诱发低磷骨软化症(tumor induced osteomalacia, TIO)为间叶源性肿瘤所致低磷骨软化症,多表现为进行性骨痛、骨质疏松、行走困难及活动受限甚至多发骨折,严重影响患者生活质量。手术切除原发灶为治疗TIO的有效方法,但间叶源性肿瘤往往位置隐匿、定位困难。本研究报道5例以生长抑素受体显像术前定位诱发TIO的磷酸盐尿性间叶肿瘤(phosphaturic mesenchymal tumor, PMT)原发病灶的结果。 展开更多
关键词 骨软化症 低磷血症 体层摄影术 发射型计算机 单光子 正电子发射断层显像
下载PDF
磷酸盐尿性间叶性肿瘤影像学表现
13
作者 王娟 熊颖 +2 位作者 万维佳 朱虹全 朱文珍 《中国医学影像学杂志》 CSCD 北大核心 2024年第10期1058-1062,共5页
目的分析磷酸盐尿性间叶性肿瘤的多模态影像学表现。资料与方法回顾性收集2012年11月—2022年6月华中科技大学同济医学院附属同济医院经病理及分子影像证实的磷酸盐尿性间叶性肿瘤10例,分析4例CT、7例MRI及10例核医学影像特征和临床特... 目的分析磷酸盐尿性间叶性肿瘤的多模态影像学表现。资料与方法回顾性收集2012年11月—2022年6月华中科技大学同济医学院附属同济医院经病理及分子影像证实的磷酸盐尿性间叶性肿瘤10例,分析4例CT、7例MRI及10例核医学影像特征和临床特点。结果10例患者主要临床症状:疼痛8例,无力4例,伴多发骨折9例。实验室检查:10例血磷降低,6例血25-羟维生素D降低,10例血碱性磷酸酶升高。CT平扫混杂密度4例,MRI平扫混杂信号6例,钙化多见,部分伴囊变及脂肪成分;增强后7例呈中度到明显不均匀强化。8例^(99)Tc^(m)-MDP SPECT全身骨显像示多发骨及关节摄取增高,8例^(18)FFDG PET/CT示病灶代谢无增高或轻度增高,10例^(68)Ga-DOTATATE PET/CT均表现为病灶部位明显高摄取。结论磷酸盐尿性间叶性肿瘤患者以疼痛、骨折及低磷血症为典型临床表现,影像学特征为病灶小且隐匿、成分复杂,^(68)Ga-DOTATATE PET/CT显像对检出肿瘤高度敏感。 展开更多
关键词 骨软化症 低磷血症 磁共振成像 正电子发射断层摄影术 单光子发射计算机断层摄影术 氟脱氧葡萄糖F18 病理学 外科
下载PDF
疑诊原发性甲状旁腺功能亢进症的患者术前^(99m)Tc-MIBI SPECT/CT显像结果的影响因素分析
14
作者 郭月红 黄京伟 +1 位作者 张腾 杨敏福 《首都医科大学学报》 CAS 北大核心 2024年第1期31-35,共5页
目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomograp... 目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomography/computed tomography,SPECT/CT)(以下简称MIBI SPECT/CT)显像结果的影响因素。方法将2019年1月至2023年8月于首都医科大学附属北京朝阳医院疑诊PHPT并在术前完善甲状旁腺MIBI SPECT/CT显像的257例患者作为研究对象。比较MIBI SPECT/CT显像阳性组和阴性组的实验室检查、病理特征及影像特征。采用多因素Logistic回归分析MIBI SPECT/CT显像结果的影响因素。结果单因素分析显示,与阴性组相比,血清总钙、血清甲状旁腺激素(parathyroid hormone,PTH)、碱性磷酸酶(alkaline phosphatase,ALP)水平在阳性组显著升高(P<0.05);病灶的病理类型、最大径、体积及位置在两组间差异有统计学意义(P<0.05)。多因素Logistic回归分析显示,术前血清PTH水平、病灶病理类型、位置及最大径与MIBI SPECT/CT显像结果阳性显著相关(P<0.05)。结论疑诊PHPT患者术前MIBI SPECT/CT显像结果受多重因素影响,术前血清PTH水平、病灶病理类型、位置及最大径是MIBI SPECT/CT显像结果的独立影响因素。 展开更多
关键词 原发性甲状旁腺功能亢进症(PHPT) ^(99m)Tc-甲氧基异丁基异腈(MIBI) SPECT/CT
下载PDF
心脏数字化单光子发射型电子计算机断层扫描设备质量控制研究
15
作者 谭展 刘辉 +1 位作者 马睿 谭光享 《中国医学装备》 2024年第10期6-9,共4页
目的:研究心脏数字化单光子发射型电子计算机断层扫描(SPECT)设备质量控制方法,为制定数字化SPECT设备质量控制标准提供参考。方法:依据美国电器制造商协会《伽玛照相机性能测试》(NEMA NU1-2018)和心脏数字化SPECT设备相关厂家执行的... 目的:研究心脏数字化单光子发射型电子计算机断层扫描(SPECT)设备质量控制方法,为制定数字化SPECT设备质量控制标准提供参考。方法:依据美国电器制造商协会《伽玛照相机性能测试》(NEMA NU1-2018)和心脏数字化SPECT设备相关厂家执行的设备日常质量保证的测试方法,采用一种通用质量控制方法,适用于使用半导体碲锌镉(CZT)材料且扫描时探头多角度转动的心脏数字化SPECT设备的质量控制。检测内容包括设备系统能量分辨率、系统均匀性、系统扫描灵敏度、带散射的断层空间分辨力和系统最大计数率5个检测项目。结果:检测结果与厂家要求相比较,系统能量分辨率、系统均匀性、系统扫描灵敏度、带散射的断层空间分辨力和系统最大计数率等5个项目的第1次检测结果分别为5.8%、8%、67811计数/(min·MBq)、4.91 mm和1.8×10^(6)s^(-1),第2次检测结果分别为5.6%、6%、68297计数/(min·MBq)、4.96mm和1.8×10^(6)s^(-1),均符合厂家指标的要求。结论:采用的质量控制方法能够科学并客观评价此类设备的运行状态,可为制定数字化SPECT设备质量控制标准提供数据支持。 展开更多
关键词 碲锌镉 单光子发射型电子计算机断层扫描(SPECT) 质量控制 心脏 系统能量分辨率
下载PDF
靶向PSMA诊疗一体化:应用与进展
16
作者 张召奇 赵新明 《肿瘤影像学》 2024年第5期475-484,共10页
前列腺特异性膜抗原(prostate-specific membrane antigen,PSMA)最早在前列腺癌细胞中发现,是前列腺癌等高表达PSMA肿瘤诊疗的重要靶点。多种显像和治疗核素标记的PSMA不同配体在前列腺癌诊疗一体化中显示出重要作用。本文就靶向PSMA诊... 前列腺特异性膜抗原(prostate-specific membrane antigen,PSMA)最早在前列腺癌细胞中发现,是前列腺癌等高表达PSMA肿瘤诊疗的重要靶点。多种显像和治疗核素标记的PSMA不同配体在前列腺癌诊疗一体化中显示出重要作用。本文就靶向PSMA诊疗一体化的相关研究和临床应用进展进行述评。 展开更多
关键词 前列腺癌 前列腺特异性膜抗原 抗体 小分子抑制剂 正电子发射体层成像 单光子发射体层成像
下载PDF
Diffusion-weighted magnetic resonance imaging with short T1 inversion recovery-echo planar imaging combined with dual-head coincidence single photon emission computed tomography for diagnosing solitary pulmonary nodule 被引量:1
17
作者 WANG Wei XU Jin-zhi +1 位作者 ZHANG Tong SHEN Bao-zhong 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第24期3717-3721,共5页
Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) ... Positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) has not been widely used in China for expensive cost ($1200). Dual-head coincidence single photon emission computed tomography (DHC-SPECT) can depict many of the lesions depicted with a PET scanner in the lungs, which is used in place of PET-CT for discriminating malignant from benign pulmonary nodules in many studies. However, DHC-SPECT has inevitable false-negative results because the sensitivity for small lesions less than 2.0 cm is limited, and has high false-positive rate for active inflammatory nodules. Furthermore,DHC-SPECT also has a considerably higher cost ($300 in China) than other imaging examination. 展开更多
关键词 diffusion-weighted imaging magnetic resonance imaging decision tree analysis dual-head coincidence single photon emission computed tomography solitary pulmonary nodules lung cancer
原文传递
SAPHO综合征累及骨及关节^(99)Tc^(m)-MDP SPECT/CT显像表现 被引量:2
18
作者 曹小梅 李佳苗 +5 位作者 李冬菊 马小伟 吴玉婷 王蓉 王莹 杨吉琴 《中国医学影像技术》 CSCD 北大核心 2024年第3期420-424,共5页
目的观察^(99)Tc^(m)-MDP SPECT/CT显像所示滑膜炎、痤疮、脓疱病、骨肥厚及骨炎(SAPHO)综合征累及骨与关节表现。方法回顾性分析69例SAPHO综合征患者^(99)Tc^(m)-MDP SPECT/CT资料,以聚类分析法评估SAPHO综合征累及骨、关节模式。结果... 目的观察^(99)Tc^(m)-MDP SPECT/CT显像所示滑膜炎、痤疮、脓疱病、骨肥厚及骨炎(SAPHO)综合征累及骨与关节表现。方法回顾性分析69例SAPHO综合征患者^(99)Tc^(m)-MDP SPECT/CT资料,以聚类分析法评估SAPHO综合征累及骨、关节模式。结果根据聚类分析,SAPHO所致骨与关节病变可分为肋骨型(n=19)、脊柱型(n=32)和胸锁关节型(n=18)。共于19例肋骨型检出145处病灶,包括60处肋骨病灶及95处其他病灶,半数以上呈低、中度摄取;半数呈溶骨性骨质破坏、边缘呈低度摄取;少数肋骨密度无明显改变。脊柱型多累及中轴骨(27/32,84.38%);椎体病变多累及一侧肋椎关节、呈连续性分布及低、中度摄取。胸锁关节型均累及胸锁关节,半数以上病灶位于胸锁关节并呈高度摄取,以“牛头征”和“半牛头征”为典型表现,多见骨质增生硬化、骨皮质肥厚。结论SAPHO综合征累及骨关节可分为肋骨型、脊柱型及胸锁关节型。全身骨显像缺乏“牛头征”或“半牛头征”等典型表现时,结合临床表现及SPECT/CT融合显像有助于诊断。 展开更多
关键词 SAPHO综合征 体层摄影术 发射型计算机 单光子
下载PDF
螺旋采集改善SPECT定量准确性及图像质量:体模研究
19
作者 宋国庆 马成皓 +7 位作者 杨双臣 杨鑫 张新超 田丛娜 胡玉敬 秦亚楠 魏强 边艳珠 《中国医学影像技术》 CSCD 北大核心 2024年第3期446-450,共5页
目的观察螺旋采集用于改善SPECT定量准确性及图像质量的价值。方法针对1个包含6个球体(直径分别为37、28、22、17、13和10 mm)的体模模型,分别向球体及体模腔内灌注640 kBq/ml及20 kBq/ml^(99)Tc^(m)O_(4)^(-)溶液,并以5、10及15秒/帧... 目的观察螺旋采集用于改善SPECT定量准确性及图像质量的价值。方法针对1个包含6个球体(直径分别为37、28、22、17、13和10 mm)的体模模型,分别向球体及体模腔内灌注640 kBq/ml及20 kBq/ml^(99)Tc^(m)O_(4)^(-)溶液,并以5、10及15秒/帧行螺旋采集与常规步进采集;比较2种采集方式所获图像质量主观评分及客观参数,包括本底变异系数(CV)、对比度噪声比(CNR)、平均放射性计数(C_(sphere))和测量定量误差百分比(Error%)的差异。结果各采集时间下,螺旋采集图像质量评分均高于常规步进采集,以5秒/帧时二者差值最大;螺旋采集的CV、CNR、C_(sphere)均优于常规步进采集(P均<0.05)。排除直径10、13 mm球体后,5、10秒/帧下,螺旋采集Error%均优于常规步进采集(P均<0.05),而15秒/帧下二者差异无统计学意义(P均>0.05)。结论相同采集时间、尤其较短采集时间下,以螺旋采集所获SPECT的定量准确性及图像质量优于常规步进采集。 展开更多
关键词 体层摄影术 发射型计算机 单光子 体模 显像术 定量 图像质量
下载PDF
Reversible posterior leukoencephalopathy syndrome: single photon emission computerized tomography observations
20
作者 Salvadeeswaran Meenakshi-Sundaram Sathyam Senthilnathan +3 位作者 Kaliappan Gurusamy Srinivasan Somalinga Nagendran Karthik Pandi Suresh Somasundaram Palanirajan 《Neuroimmunology and Neuroinflammation》 2017年第2期28-32,共5页
The authors report clinical correlations of single photon emission computerized tomography (SPECT) findings in reversible posterior leukoencephalopathy (RPL). These are observations that have not received wide attenti... The authors report clinical correlations of single photon emission computerized tomography (SPECT) findings in reversible posterior leukoencephalopathy (RPL). These are observations that have not received wide attention in literature. A 31-year-old hypertensive gentleman, on discontinuing antihypertensive medications, presented with vomiting, headache, focal motor to bilateral tonic-clonic seizures, altered sensorium, right gaze palsy and right hemiparesis. Accelerated hypertension was noted and he improved well with antihypertensive and anticonvulsant therapy. While cranial magnetic resonance imaging (MRI) revealed extensive bilateral lesions, SPECT imaging revealed perfusion defects involving bilateral basal ganglia, left parieto-occipital, right cerebellar and right occipital regions, which corresponded with clinical deficits on examination. While MRI is the standard of care for the evaluation of RPL, this case suggests that SPECT abnormalities may be better localized to the pathogenic lesions. Furthermore, this may begin to explain the pathophysiology of injury in RPL. 展开更多
关键词 Reversible POSTERIOR LEUKOENCEPHALOPATHY single photon emission computerized tomography imaging accelerated hypertension CROSSED CEREBELLAR DIASCHISIS
原文传递
上一页 1 2 104 下一页 到第
使用帮助 返回顶部