We perform a theoretical study on dynamic interference in single photon ionization of ground state hydrogen atoms in the presence of a super-intense ultra-fast chirped laser pulse of different chirp types(equal-power ...We perform a theoretical study on dynamic interference in single photon ionization of ground state hydrogen atoms in the presence of a super-intense ultra-fast chirped laser pulse of different chirp types(equal-power and equal-FWHM laser pulses)by numerically solving the time-dependent Schrödinger equation in one dimension.We investigate the influences of peak intensity and chirp parameters on the instantaneous ionization rate and photoelectron yield,respectively.We also compare the photoelectron energy spectra for the ionization by the laser pulses with different chirp types.We find that the difference between the instantaneous ionization rates for the ionization of hydrogen atom driven by two different chirped laser pulses is originated from the difference in variation of vector potentials with time.展开更多
Ammonia(NH_(3))is ubiquitous in the atmosphere,it can affect the formation of secondary aerosols and particulate matter,and cause soil eutrophication through sedimentation.Currently,the use of radioactive primary reag...Ammonia(NH_(3))is ubiquitous in the atmosphere,it can affect the formation of secondary aerosols and particulate matter,and cause soil eutrophication through sedimentation.Currently,the use of radioactive primary reagent ion source and the humidity interference on the sensitivity and stability are the two major issues faced by chemical ionization mass spectrometer(CIMS)in the analysis of atmospheric ammonia.In this work,a vacuum ultraviolet(VUV)Kr lamp was used to replace the radioactive source,and acetone was ionized under atmospheric pressure to obtain protonated acetone reagent ions to ionize ammonia.The ionization source is designed as a separated three-zone structure,and even 90 vol.%high-humidity samples can still be directly analyzed with a sensitivity of sub-ppbv.A signal normalization processing method was designed,and with this new method,the quantitative relative standard deviation(RSD)of the instrument was decreased from 17.5%to9.1%,and the coefficient of determination was increased from 0.8340 to 0.9856.The humidity correction parameters of the instrument were calculated from different humidity,and the ammonia concentrations obtained under different humidity were converted to its concentration under zero humidity condition with these correction parameters.The analytical time for a single sample is only 60 sec,and the limit of detection(LOD)was 8.59 pptv(signalto-noise ratio S/N=3).The ambient measurement made in Qingdao,China,in January 2021 with this newly designed CIMS,showed that the concentration of ammonia ranged from 1 to 130 ppbv.展开更多
It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency f...It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency field enhanced chemical ionization source (RF-ECI) with vacuum ultraviolet (VUV)lamp by coupling radiofrequency electric field and direct-current field together. The experiment resultsshowed that the sensitivity of benzene, toluene, hydrogen sulfide and other compounds increased by 2-3orders of magnitude under the introduction of RF-ECI comparing to traditional single photon ionization(SPI). At the same time, the reagent ion of O2+ realized the charge transfer reaction chemical ionization,and the RF-ECI effectively expanded the detection range of the VUV lamp based SPI. The VUV lamp hasinherent advantages in the on-site analytical instrument for its small size and low power consumption,and the VUV lamp based RF-ECI miniature time-of-flight mass spectrometer (TOFMS) has a limit-of-detection for H2S as low as 0.0571 mg/m3, and it is expected to be used widely in the field of on-site rapidanalvsis.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11774131 and 91850114).
文摘We perform a theoretical study on dynamic interference in single photon ionization of ground state hydrogen atoms in the presence of a super-intense ultra-fast chirped laser pulse of different chirp types(equal-power and equal-FWHM laser pulses)by numerically solving the time-dependent Schrödinger equation in one dimension.We investigate the influences of peak intensity and chirp parameters on the instantaneous ionization rate and photoelectron yield,respectively.We also compare the photoelectron energy spectra for the ionization by the laser pulses with different chirp types.We find that the difference between the instantaneous ionization rates for the ionization of hydrogen atom driven by two different chirped laser pulses is originated from the difference in variation of vector potentials with time.
基金partially supported by the National Special Fund for the Development of Major Research Equipment and Instrument(No.2020YFF01014503)NSF of China(No.21874134)Young Taishan Scholars(No.tsqn201909039)
文摘Ammonia(NH_(3))is ubiquitous in the atmosphere,it can affect the formation of secondary aerosols and particulate matter,and cause soil eutrophication through sedimentation.Currently,the use of radioactive primary reagent ion source and the humidity interference on the sensitivity and stability are the two major issues faced by chemical ionization mass spectrometer(CIMS)in the analysis of atmospheric ammonia.In this work,a vacuum ultraviolet(VUV)Kr lamp was used to replace the radioactive source,and acetone was ionized under atmospheric pressure to obtain protonated acetone reagent ions to ionize ammonia.The ionization source is designed as a separated three-zone structure,and even 90 vol.%high-humidity samples can still be directly analyzed with a sensitivity of sub-ppbv.A signal normalization processing method was designed,and with this new method,the quantitative relative standard deviation(RSD)of the instrument was decreased from 17.5%to9.1%,and the coefficient of determination was increased from 0.8340 to 0.9856.The humidity correction parameters of the instrument were calculated from different humidity,and the ammonia concentrations obtained under different humidity were converted to its concentration under zero humidity condition with these correction parameters.The analytical time for a single sample is only 60 sec,and the limit of detection(LOD)was 8.59 pptv(signalto-noise ratio S/N=3).The ambient measurement made in Qingdao,China,in January 2021 with this newly designed CIMS,showed that the concentration of ammonia ranged from 1 to 130 ppbv.
基金financially supported by the National Natural Science Foundation of China(Nos.21375129 and 21675155)
文摘It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency field enhanced chemical ionization source (RF-ECI) with vacuum ultraviolet (VUV)lamp by coupling radiofrequency electric field and direct-current field together. The experiment resultsshowed that the sensitivity of benzene, toluene, hydrogen sulfide and other compounds increased by 2-3orders of magnitude under the introduction of RF-ECI comparing to traditional single photon ionization(SPI). At the same time, the reagent ion of O2+ realized the charge transfer reaction chemical ionization,and the RF-ECI effectively expanded the detection range of the VUV lamp based SPI. The VUV lamp hasinherent advantages in the on-site analytical instrument for its small size and low power consumption,and the VUV lamp based RF-ECI miniature time-of-flight mass spectrometer (TOFMS) has a limit-of-detection for H2S as low as 0.0571 mg/m3, and it is expected to be used widely in the field of on-site rapidanalvsis.