Fault detection caused by single event effect( SEE) in system was studied,and an improved fault detection algorithm by fusing multi-information entropy for detecting soft error was proposed based on multi-objective de...Fault detection caused by single event effect( SEE) in system was studied,and an improved fault detection algorithm by fusing multi-information entropy for detecting soft error was proposed based on multi-objective detection approach and classification management method. In the improved fault detection algorithm, the analysis model of posteriori information with corresponding multi-fault alternative detection points was formulated through correlation information matrix, and the maximum incremental information entropy was chosen as the classification principle for the optimal detection points. A system design example was given to prove the rationality and feasibility of this algorithm.This fault detection algorithm can achieve the purpose of fault detection and resource configuration with high efficiency.展开更多
When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and ...When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished.展开更多
This paper presents a procedure of sing le gear tooth analysis for early detection and diagnosis of gear faults. The objec tive of this procedure is to develop a method for more sensitive detection of th e incipient ...This paper presents a procedure of sing le gear tooth analysis for early detection and diagnosis of gear faults. The objec tive of this procedure is to develop a method for more sensitive detection of th e incipient faults and locating the faults in the gear. The main idea of the sin gle gear tooth analysis is that the vibration signals collected with a high samp ling rate are divided into a number of segments with the same time interval. The number of signal segments is equal to that of the gear teeth. The analysis of i ndividual segments reveals more sensitively the changes of the vibration signals in both time and frequency domain caused by gear faults. In addition, the locat ion of a failed tooth can be indicated in terms of the position of the segment t hat deviates from the normal segments. An experimental investigation verified th e advantages of the single gear tooth analysis.展开更多
A diagnostic signal current trace detecting based single phase-to-ground fault line identifica- tion and section location method for non-effectively grounded distribution systems is presented in this paper.A special d...A diagnostic signal current trace detecting based single phase-to-ground fault line identifica- tion and section location method for non-effectively grounded distribution systems is presented in this paper.A special diagnostic signal current is injected into the fault distribution system,and then it is detected at the outlet terminals to identify the fault line and at the sectionalizing or branching point along the fault line to locate the fault section.The method has been put into application in actual distribution network and field experience shows that it can identify the fault line and locate the fault section correctly and effectively.展开更多
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing...It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.展开更多
The simulation of nanoindentation into single nickel crystal is performed by using quasi continuum method.The strain energy-displacement and load-displacement curves are presented to study the mechanical behavior of t...The simulation of nanoindentation into single nickel crystal is performed by using quasi continuum method.The strain energy-displacement and load-displacement curves are presented to study the mechanical behavior of the dislocation nucleation.The characteristics of the stacking fault and dislocation nucleation are determined by calculating the centro-symmetry parameters and analyzing the displacement field of the atoms beneath the indenter.The structure of the stacking fault and the characteristics of dislocation obtained in the simulation by quasicontinuum method are reproduced in the simulation by molecular dynamics.展开更多
文摘Fault detection caused by single event effect( SEE) in system was studied,and an improved fault detection algorithm by fusing multi-information entropy for detecting soft error was proposed based on multi-objective detection approach and classification management method. In the improved fault detection algorithm, the analysis model of posteriori information with corresponding multi-fault alternative detection points was formulated through correlation information matrix, and the maximum incremental information entropy was chosen as the classification principle for the optimal detection points. A system design example was given to prove the rationality and feasibility of this algorithm.This fault detection algorithm can achieve the purpose of fault detection and resource configuration with high efficiency.
文摘When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished.
文摘This paper presents a procedure of sing le gear tooth analysis for early detection and diagnosis of gear faults. The objec tive of this procedure is to develop a method for more sensitive detection of th e incipient faults and locating the faults in the gear. The main idea of the sin gle gear tooth analysis is that the vibration signals collected with a high samp ling rate are divided into a number of segments with the same time interval. The number of signal segments is equal to that of the gear teeth. The analysis of i ndividual segments reveals more sensitively the changes of the vibration signals in both time and frequency domain caused by gear faults. In addition, the locat ion of a failed tooth can be indicated in terms of the position of the segment t hat deviates from the normal segments. An experimental investigation verified th e advantages of the single gear tooth analysis.
基金Postdoctoral Foundation of China(No.20070410755)PAN Zhencun,born in 1962,male,postdoctor researcher.
文摘A diagnostic signal current trace detecting based single phase-to-ground fault line identifica- tion and section location method for non-effectively grounded distribution systems is presented in this paper.A special diagnostic signal current is injected into the fault distribution system,and then it is detected at the outlet terminals to identify the fault line and at the sectionalizing or branching point along the fault line to locate the fault section.The method has been put into application in actual distribution network and field experience shows that it can identify the fault line and locate the fault section correctly and effectively.
文摘It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.
基金Funded by National Basic Research Program of China (No.G2006CB605103)
文摘The simulation of nanoindentation into single nickel crystal is performed by using quasi continuum method.The strain energy-displacement and load-displacement curves are presented to study the mechanical behavior of the dislocation nucleation.The characteristics of the stacking fault and dislocation nucleation are determined by calculating the centro-symmetry parameters and analyzing the displacement field of the atoms beneath the indenter.The structure of the stacking fault and the characteristics of dislocation obtained in the simulation by quasicontinuum method are reproduced in the simulation by molecular dynamics.