期刊文献+
共找到2,344篇文章
< 1 2 118 >
每页显示 20 50 100
Single Phase-to-Ground Fault Line Identification and Section Location Method for Non-Effectively Grounded Distribution Systems Based on Signal Injection
1
作者 潘贞存 王成山 +1 位作者 丛伟 张帆 《Transactions of Tianjin University》 EI CAS 2008年第2期92-96,共5页
A diagnostic signal current trace detecting based single phase-to-ground fault line identifica- tion and section location method for non-effectively grounded distribution systems is presented in this paper.A special d... A diagnostic signal current trace detecting based single phase-to-ground fault line identifica- tion and section location method for non-effectively grounded distribution systems is presented in this paper.A special diagnostic signal current is injected into the fault distribution system,and then it is detected at the outlet terminals to identify the fault line and at the sectionalizing or branching point along the fault line to locate the fault section.The method has been put into application in actual distribution network and field experience shows that it can identify the fault line and locate the fault section correctly and effectively. 展开更多
关键词 接地故障 识别技术 分配模式 电力系统
下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
2
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 环方法 单相的地球差错 电线走火水流分发 光纤维合成架空的地面电线 平常的地面电线
下载PDF
Engineering Calculation Method of Electromagnetic Effect on Oil/Gas Pipelines from 1 000 kV AC Transmission Line Having Single-phase Ground Fault
3
作者 ZHANG Wenliang JIANG Jun +1 位作者 GUO Jian LU Jiayu 《高电压技术》 EI CAS CSCD 北大核心 2012年第9期2145-2149,共5页
关键词 交流输电线路 油气管道 故障分析 安全距离
下载PDF
Comparison between open phase fault of arc suppression coil and single phase to earth fault in coal mine distribution network 被引量:3
4
作者 LI Xiao-bo WANG Chong-lin 《Journal of China University of Mining and Technology》 EI 2008年第3期368-372,共5页
When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and ... When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished. 展开更多
关键词 煤矿 地球断层 TPFCASC 保护措施
下载PDF
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
5
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
The Research on Grounding Protection for 110kV Resistance Grounding Distribution System 被引量:1
6
作者 Shan Sun Guo Zeng +2 位作者 Xiaozang He Yanping Lv Xinyi Li 《Energy and Power Engineering》 2013年第4期877-880,共4页
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str... Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated. 展开更多
关键词 NEUTRAL grounding System by Resistance One-phase grounding fault ZERO SEQUENCE Voltage ZERO SEQUENCE Current PROTECTION Setting
下载PDF
Grounding Systems for Power Supply Facilities
7
作者 Vladimir Anatolevich Konusarov Evgeniy Alekseevich Shutov Tatyana Evgenievna Turukina 《Energy and Power Engineering》 2019年第1期1-14,共14页
The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition... The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition to pose a threat for health, the rise of the short circuit, as a consequence of insulation faults, poses a threat to retirement of electric systems and fire risks. The reliable grounding system design has significant implications for protection of human being as well as for electrical facility protection. The set objective was performed on the base of analytical and software-based methods. Analytical method gives a qualitative indication at each step in analysis. It also allows evaluating the values effect on the result, but the method is not susceptible of tolerable accuracy, that is why analytical method serves as initial approximation in differentiating. Specified estimation can be performed in such software package as MATLAB or ETAP. Software-based estimation is based on the finite element method (FEM), the main advantage of which is the ability to create different forms of grounding and allows obtaining distribution graphs of the step potential on the earth’s surface and touch potential. The calculation results in comparison of analytical and software-based methods taking into account the grounding optimization. There are conclusions on the most effective ground network. 展开更多
关键词 grounding Device Current-Using Equipment Short-Circuit fault single phase-to-ground fault Main STEP Down Substation (MSDS) TN-C TN-S TN-C-S TT IT Indirect Contact STEP Potential FEM IEEE
下载PDF
Fault diagnosis in neutral point indirectly grounded system basedon information fusion
8
作者 于飞 鞠丽叶 +2 位作者 刘喜梅 崔平远 钟秋海 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2003年第4期434-437,共4页
In neutral point indirectly grounded systems, phase-to-ground fault is putting new demands on fault diagnosis technology. Information fusion is applied to detect the phase-to-ground fault, which integrates several sou... In neutral point indirectly grounded systems, phase-to-ground fault is putting new demands on fault diagnosis technology. Information fusion is applied to detect the phase-to-ground fault, which integrates several sources of information, including line current, line voltage, zero sequence current and voltage, and quintic harmonic wave component. This method is testified through the simulation of Matlab. Simulation results show that the precision and reliability of the detection has been greatly increased. 展开更多
关键词 中性点间接接地系统 信息融合 错误诊断 电力网
下载PDF
The Research of Voltage Sag and Power Frequency Overvoltage on 110kV Resistance Grounding System
9
作者 Guo Zeng Guangliang Feng +1 位作者 Yanping Lv Shan Sun 《Energy and Power Engineering》 2013年第4期873-876,共4页
This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence netwo... This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence network analysis of the -11 transformer, and concludes the scope of voltage sag and swell and the degree of power frequency overvoltage and their influencing factors in the 110 kV resistance grounding system. Accordingly this paper puts forward the resistance choosing principle: the resistance grounding coefficient must be equal to or greater than 10. So it can not only wipe out the voltage sag and voltage swell but also make sure the overvoltage is limited to electrical equipment allowing range. The method mentioned above is verified by simulation results of a 110 kV power system in ATP. 展开更多
关键词 NEUTRAL grounding System by RESISTANCE One-phase grounding fault Power Frequency OVERVOLTAGE
下载PDF
基于FTU的配电网单相接地故障定位与恢复方法 被引量:2
10
作者 彭军林 石勇 +2 位作者 于哲 曾先锋 笃峻 《电器与能效管理技术》 2024年第2期72-78,共7页
配电网发生最多的故障是接地故障。针对准确地检测隔离接地故障线路并尽快恢复供电,提出基于配电开关监控终端(FTU)的配电网单相接地故障定位与恢复方法。利用配电网各节点FTU的小波包变换暂态选线及相电流暂态特征选线技术,结合故障路... 配电网发生最多的故障是接地故障。针对准确地检测隔离接地故障线路并尽快恢复供电,提出基于配电开关监控终端(FTU)的配电网单相接地故障定位与恢复方法。利用配电网各节点FTU的小波包变换暂态选线及相电流暂态特征选线技术,结合故障路径自适应处理控制策略,配合首开关延时合闸逻辑,从而实现多分支配电网故障定位与自动隔离恢复。所提方法能够快速选出故障线路并隔离故障区段,有利于故障快速消除,提高系统运行的安全性、可靠性。 展开更多
关键词 单相接地故障 小波包 故障定位 自动隔离恢复 配电开关监控终端
下载PDF
风电场集电线路单相接地故障柔性电压消弧与动态保护新原理
11
作者 喻锟 杨理斌 +3 位作者 曾祥君 王沾 李理 卓超 《中国电机工程学报》 EI CSCD 北大核心 2024年第5期1789-1801,I0010,共14页
为解决风电场集电系统长期存在的线路单相接地故障处理难题,提出风电场中性点柔性接地方式,理论推导获得柔性接地风电场三序等效电路,与集电线路单相接地故障复合序网模型,建立风电场零序电压柔性调控理论,提出集电线路单相接地故障柔... 为解决风电场集电系统长期存在的线路单相接地故障处理难题,提出风电场中性点柔性接地方式,理论推导获得柔性接地风电场三序等效电路,与集电线路单相接地故障复合序网模型,建立风电场零序电压柔性调控理论,提出集电线路单相接地故障柔性电压消弧方法,可主动将故障点电压及故障残流迅速抑制到零,实现单相接地故障电弧的可靠消除。进一步提出基于零序电流动态增量的高阻故障辨识与保护方法,通过柔性调控零序补偿电流,逐渐放大故障残流,实现永久性单相接地故障的灵敏感知与保护。利用PSCAD/EMTDC搭建含双馈异步风电机(doubly-fedinduction generator,DFIG)的规模化风电场模型,模拟多种运行与故障条件对所提方法进行验证,仿真结果表明,该方法能够在考虑系统不平衡电压的情况下精准调控集电线路故障点电压,实现瞬时性单相接地故障快速可靠消弧,动态感知并持续抑制永久性单相接地故障残流,实现集电线路高阻接地故障的灵敏保护。该技术有望提升风电场运行灵活性与故障防御能力,有力保障新能源电能外送的持续性、可靠性。 展开更多
关键词 集电线路 柔性接地 单相接地故障 电压消弧 动态保护
下载PDF
基于有源消弧暂态衰减信息的配电网接地故障跟踪检测方法
12
作者 刘宝稳 万子雄 +2 位作者 曾祥君 张慧芬 马宏忠 《中国电机工程学报》 EI CSCD 北大核心 2024年第2期464-475,I0003,共13页
现有配电网单相接地故障检测技术缺乏消弧过程的故障程度跟踪与选线能力。该文充分利用消弧过程中的暂态信息,建立考虑线路参数不对称的集总参数等效模型,论证消弧过程零序电压衰减直流特征的物理意义,提出考虑快速消弧的配电网故障检... 现有配电网单相接地故障检测技术缺乏消弧过程的故障程度跟踪与选线能力。该文充分利用消弧过程中的暂态信息,建立考虑线路参数不对称的集总参数等效模型,论证消弧过程零序电压衰减直流特征的物理意义,提出考虑快速消弧的配电网故障检测新方法,对于低、高阻接地故障均有较高的检测灵敏度。实际应用中,仅需观测消弧全补偿电流投切过程中零序电压及零序电流波形,即可实现过渡电阻测量、故障程度跟踪与故障选线,具有瞬时性故障实时跟踪、故障检测与故障消弧同步进行的优势,操作简单、易于实现。仿真实验证实了方法的有效性,为配电网故障检测提供了新的理论依据。 展开更多
关键词 单相接地故障 有源柔性接地 衰减直流特征 过渡电阻辨识 故障选线
下载PDF
单相脉冲整流器故障在线智能诊断实验设计
13
作者 王青元 张坤 苟斌 《实验室研究与探索》 CAS 北大核心 2024年第5期36-41,共6页
针对高速列车电力牵引系统中单相脉冲整流器的功率器件开路故障和传感器故障,设计了基于数据驱动的故障在线智能诊断实验。首先,对单相脉冲整流器系统进行数学建模,分析功率器件开路故障的故障拓扑和传感器故障的故障机理;然后,基于极... 针对高速列车电力牵引系统中单相脉冲整流器的功率器件开路故障和传感器故障,设计了基于数据驱动的故障在线智能诊断实验。首先,对单相脉冲整流器系统进行数学建模,分析功率器件开路故障的故障拓扑和传感器故障的故障机理;然后,基于极限学习机算法和非线性自回归结构设计智能诊断模型,并将故障在线智能诊断实验分为离线训练和在线验证2个阶段;最后,基于RT Box半实物仿真器搭建快速原型控制实验平台,对故障模型和诊断模型进行实验验证。实验结果表明,构建的单相脉冲整流器故障在线智能诊断模型可以在1/4个基波周期内检测到故障的发生,并在3/4个基波周期内识别出具体故障类型。 展开更多
关键词 单相脉冲整流器 故障诊断 功率器件开路故障 传感器故障 半实物仿真器
下载PDF
不同稳态工况对同步调相机单相短路后暂态温升的影响
14
作者 许国瑞 胡沛东 +2 位作者 李志强 詹阳 赵海森 《中国电机工程学报》 EI CSCD 北大核心 2024年第4期1587-1596,I0028,共11页
同步调相机可在系统故障时为特高压直流换流站提供暂态无功支持,以保持系统电压稳定,防止直流换相失败,但调相机的高无功输出也会导致其温升增加,运行能力受限。系统故障前同步调相机的初始工况是影响其暂态温升和运行能力的一个重要因... 同步调相机可在系统故障时为特高压直流换流站提供暂态无功支持,以保持系统电压稳定,防止直流换相失败,但调相机的高无功输出也会导致其温升增加,运行能力受限。系统故障前同步调相机的初始工况是影响其暂态温升和运行能力的一个重要因素,为研究系统低电压时调相机暂态温升与初始工况之间的关系,该文将调相机的电磁场、温度场与电网模型耦合,计算调相机不同稳态工况下的定转子损耗和温度分布;以线路单相短路故障引起的系统低电压为例,研究调相机初始工况对暂态温升的影响。在考虑各结构件最大容许温度的条件下,揭示调相机单相短路持续时间随初始工况的变化规律。研究结果为提升调相机在系统低电压下的暂态运行能力提供技术支持。 展开更多
关键词 同步调相机 稳态运行 单相短路故障 损耗计算 温度场
下载PDF
基于初始电流行波相位的多端混合直流线路单端保护方案
15
作者 戴志辉 牛宝仪 +3 位作者 邱宏逸 奚潇睿 韩哲宇 韦舒清 《高电压技术》 EI CAS CSCD 北大核心 2024年第2期649-659,I0003-I0010,共19页
为了解决LCC-MMC型多端混合直流系统线路保护存在的问题,提出一种基于初始电流行波相位的多端混合直流线路单端保护方案。首先基于多端混合直流输电线路发生不同位置和类型的故障工况,推导直流线路入射电压行波的解析式并计算其高频段... 为了解决LCC-MMC型多端混合直流系统线路保护存在的问题,提出一种基于初始电流行波相位的多端混合直流线路单端保护方案。首先基于多端混合直流输电线路发生不同位置和类型的故障工况,推导直流线路入射电压行波的解析式并计算其高频段相位。其次结合线路边界行波折反射原理和测量波阻抗特性,提出利用初始电压行波相位的区内外识别判据,并根据雷击和短路故障的入射行波低频相位特性构建雷击干扰判据。在PSCAD/EMTDC中搭建昆柳龙多端混合直流系统模型进行验证,证明所提方案仅利用单端量信息即可满足故障判断和选线要求,满足速度性的同时具备一定的抗过渡电阻能力(500Ω)。 展开更多
关键词 多端混合直流 电流行波相位 线路故障 S变换 单端量保护
下载PDF
基于模型识别的有源配电网单相接地故障定位方法 被引量:1
16
作者 许守东 欧阳金鑫 +3 位作者 陈宇捷 陈纪宇 王建 熊小伏 《电力系统保护与控制》 EI CSCD 北大核心 2024年第5期51-60,共10页
分布式电源(distributed generation,DG)大量接入使配电网继电保护面临严峻挑战。单相接地故障发生概率大,但故障信息十分微弱,特别是在DG多样化故障输出特性的影响下,有源配电网单相故障定位的准确性常难以保证。为此,提出了一种基于... 分布式电源(distributed generation,DG)大量接入使配电网继电保护面临严峻挑战。单相接地故障发生概率大,但故障信息十分微弱,特别是在DG多样化故障输出特性的影响下,有源配电网单相故障定位的准确性常难以保证。为此,提出了一种基于模型识别的有源配电网单相接地故障定位方法。分析了配电网单相接地故障下DG的输出特性,建立了在不同故障位置下有源配电网的正序增广网络,构建了故障位置关于馈线出口以及DG输出电流的函数,建立了配电网单相接地故障位置模型,利用不同故障位置下短路电流矢量占比系数的差异性构建了新的故障定位判据。通过将单相接地故障定位问题转化为故障位置模型系数的求解问题,提高了故障定位的准确性和实用性。理论和仿真分析表明,在不同故障位置、不同过渡电阻下均能准确定位单相接地故障,具有原理清晰、故障特征量采集便捷、灵敏性和可靠性高的优点。 展开更多
关键词 配电网 分布式电源 单相接地故障 故障区段定位 故障测距
下载PDF
基于低压侧负序量特征的小电流系统单相接地故障检测方法 被引量:1
17
作者 张明泽 栾文鹏 +1 位作者 艾欣 徐丙垠 《电网技术》 EI CSCD 北大核心 2024年第4期1654-1662,I0079,共10页
随着台区智能终端量测技术的逐步成熟,实现低压侧全息感知的同时,具备对上级中压配网的多点监测能力。提出基于低压侧负序量特征的小电流系统单相接地故障检测方法。分析了中压侧发生单相接地故障后低压侧负序量的变化规律;利用负序电... 随着台区智能终端量测技术的逐步成熟,实现低压侧全息感知的同时,具备对上级中压配网的多点监测能力。提出基于低压侧负序量特征的小电流系统单相接地故障检测方法。分析了中压侧发生单相接地故障后低压侧负序量的变化规律;利用负序电流大小区分故障线路和非故障线路;提出通过负序电压与正序电压的比值系数,多点协同计算对比判断故障点区段位置,且考虑了低压侧不平衡负荷,以及故障点位于线路一端的特殊情况。通过MATLAB软件和动模实验对中低压联合配电系统的仿真计算,验证了所提方法具有良好的鲁棒性和准确性。通过智能配变终端监测上级中压配网负序量信息,实现小电流接地系统故障检测,具有实际应用和推广价值。 展开更多
关键词 故障检测 单相接地故障 小电流系统 低压量测 负序量
下载PDF
基于拐点密集区凹凸波动特性的直流配网故障检测方法 被引量:1
18
作者 王晓卫 田影 +3 位作者 高杰 王雪 梁振锋 王毅钊 《电力系统保护与控制》 EI CSCD 北大核心 2024年第9期1-15,共15页
基于模块化多电平换流器(modular multilevel converter,MMC)的柔性直流配电网具有不存在换相失败等优点。但换流器存在低惯性、弱阻尼等特性,导致故障电流上升速度快且峰值高,对系统危害极大。针对直流配电网发生单极接地故障难以准确... 基于模块化多电平换流器(modular multilevel converter,MMC)的柔性直流配电网具有不存在换相失败等优点。但换流器存在低惯性、弱阻尼等特性,导致故障电流上升速度快且峰值高,对系统危害极大。针对直流配电网发生单极接地故障难以准确选择故障馈线的问题,提出了一种基于拐点密集区凹凸波动特性的直流配网故障检测方法。首先,利用变分模态分解算法对各馈线零模电流进行分解,选取特征分量。然后,计算特征分量的二阶导数,选择拐点密集区并进行归一化处理,得到各馈线的凹凸波动性。最后,判定凹凸波动性与其他馈线相异的线路为故障线路。仿真结果表明,所提方法能够快速识别故障馈线,且受过渡电阻、采样频率、数据窗和噪声等因素影响小。 展开更多
关键词 故障检测 单极接地故障 零模电流 拐点密集区 凹凸波动性
下载PDF
基于线路容流暂态信号能量流向特征的小电流单相接地故障区段定位算法 被引量:1
19
作者 谭卫斌 吴浩波 +2 位作者 张志华 隆博 张敏 《现代电子技术》 北大核心 2024年第2期121-126,共6页
针对配电网小电流系统单相接地故障定位难的问题,提出一种基于线路容流暂态信号能量流向特征的小电流单相接地故障定位算法。该算法能够在故障发生时准确识别故障线路并定位故障区间,同时对故障前后波形的离散采样数据进行软件滤波,得... 针对配电网小电流系统单相接地故障定位难的问题,提出一种基于线路容流暂态信号能量流向特征的小电流单相接地故障定位算法。该算法能够在故障发生时准确识别故障线路并定位故障区间,同时对故障前后波形的离散采样数据进行软件滤波,得到线路的容流暂态信号分量,利用其能量流向特征对单相接地故障进行识别和区段定位。实验结果表明,所提算法能够准确区分出故障与非故障线路区段,具有自举性,可方便应用于就地型馈线自动化开关节点,具有较好的实用性。 展开更多
关键词 配电网 小电流系统 单相接地故障 容流暂态信号 故障定位 傅里叶变换
下载PDF
综合零序电流信号分量的单相接地故障选线方法 被引量:1
20
作者 赵森豪 耿蒲龙 《煤炭工程》 北大核心 2024年第3期181-188,共8页
文章提出了一种优化变分模态分解(VMD)参数与综合零序电流信号分量的选线方法,旨在解决目前矿井经消弧线圈接地供电系统发生单相接地故障时,存在的故障信号特征提取困难、噪声信号影响严重等问题。该方法利用鲸鱼优化VMD参数对零序电流... 文章提出了一种优化变分模态分解(VMD)参数与综合零序电流信号分量的选线方法,旨在解决目前矿井经消弧线圈接地供电系统发生单相接地故障时,存在的故障信号特征提取困难、噪声信号影响严重等问题。该方法利用鲸鱼优化VMD参数对零序电流信号进行分解,并根据非工频分量能量、工频分量极性和波形相关性的多重判据进行故障线路判别。利用RTDS/RSCAD搭建矿井供电系统模型,仿真测试了不同的故障情况,包括不同故障线路的故障接地电阻、故障初始相位角、故障点位置。结果显示,无论故障条件如何,该方法都有更加准确和可靠的选线结果。 展开更多
关键词 单相接地故障 变分模态分解 鲸鱼优化算法 综合信号分量 波形相关性
下载PDF
上一页 1 2 118 下一页 到第
使用帮助 返回顶部