Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
1
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation grounding current detection Zero sequence voltage detection
下载PDF
The Research on Neutral Grounding Scheme of Fengxian 35kV and 10 kV Power Grid 被引量:1
2
作者 Siming Hua Hua Zhang +2 位作者 Feng Qian Chunjie Chen Meixia Zhang 《Energy and Power Engineering》 2013年第4期897-901,共5页
Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measur... Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current. 展开更多
关键词 NEUTRAL grounding Mode Different Frequency Injected Method Capacitive Current arc SUPPRESSION COIL Low Resistance
下载PDF
Dynamic physical characteristics of DC arc on arcing horn for HVDC grounding electrode line
3
作者 刘益岑 杨晨光 +4 位作者 郭裕钧 张血琴 肖嵩 高国强 吴广宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期80-87,共8页
The dynamic physical characteristics of a DC arc on an arcing horn for a high voltage direct current(HVDC)grounding electrode line are significantly different from those of the switching device arc,secondary arc,AC fa... The dynamic physical characteristics of a DC arc on an arcing horn for a high voltage direct current(HVDC)grounding electrode line are significantly different from those of the switching device arc,secondary arc,AC fault arc and pantograph-catenary arc.In this work,an experimental platform for the DC arc on the arcing horn was built,and mechanisms of the arc column short circuit and arc root movement were studied.This work further analyzes the characteristics and mechanisms of the arc motion when wind speed and direction,magnetic field and the expansion angle of the electrode are varied.Arc root movement is more likely to occur at the upper electrode.There is a competitive relationship between arc expansion and the transferring effect.The effect of wind on the arc column is greater than the effect on the arc root.The magnetic field has a significant driving effect on both the arc column and the arc root.The research results provide a comprehensive experimental basis for forther probing the method of DC arc suppression,and the improvement of the arcing horn. 展开更多
关键词 grounding electrode line arcing horn DC arc dynamic physical characteristics
下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
4
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire
下载PDF
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
5
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
6
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
下载PDF
Fault protection method of single-phase break for distribution network considering the influence of neutral grounding modes 被引量:31
7
作者 Yang Xiao Jinxin Ouyang +2 位作者 Xiaofu Xiong Yutong Wang Yongjie Luo 《Protection and Control of Modern Power Systems》 2020年第1期111-123,共13页
With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equi... With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability. 展开更多
关键词 Distribution network single-phase break fault Protection Neutral grounding
原文传递
Multiple Random Forests Based Intelligent Location of Single-phase Grounding Fault in Power Lines of DFIG-based Wind Farm 被引量:2
8
作者 Yongli Zhu Hua Peng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1152-1163,共12页
To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes a... To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes an intelligent location method for a single-phase grounding fault based on a multiple random forests(multi-RF) algorithm. First, the simulation model is built, and the fundamental amplitudes of the zerosequence currents are extracted by a fast Fourier transform(FFT) to construct the feature set. Then, the random forest classification algorithm is applied to establish the fault section locator. The model is resampled on the basis of the bootstrap method to generate multiple sample subsets, which are used to establish multiple classification and regression tree(CART) classifiers. The CART classifiers use the mean decrease in the node impurity as the feature importance,which is used to mine the relationship between features and fault sections. Subsequently, a fault section is identified by voting on the test results for each classifier. Finally, a multi-RF regression fault locator is built to output the predicted fault distance. Experimental results with PSCAD/EMTDC software show that the proposed method can overcome the shortcomings of a single RF and has the advantage of locating a short hybrid overhead/cable line with multiple branches. Compared with support vector machines(SVMs)and previously reported methods, the proposed method can meet the location accuracy and efficiency requirements of a DFIG-based wind farm better. 展开更多
关键词 Doubly-fed induction generator(DFIG)based wind farm power line multiple random forests(multi-RF) single-phase grounding fault fault location
原文传递
Comparison between open phase fault of arc suppression coil and single phase to earth fault in coal mine distribution network 被引量:3
9
作者 LI Xiao-bo WANG Chong-lin 《Journal of China University of Mining and Technology》 EI 2008年第3期368-372,共5页
When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and ... When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished. 展开更多
关键词 open phase PROTECTION single phase to ground fault three-phase five-column arc suppression coil (TPFCASC)
下载PDF
风电场集电线路单相接地故障柔性电压消弧与动态保护新原理 被引量:1
10
作者 喻锟 杨理斌 +3 位作者 曾祥君 王沾 李理 卓超 《中国电机工程学报》 EI CSCD 北大核心 2024年第5期1789-1801,I0010,共14页
为解决风电场集电系统长期存在的线路单相接地故障处理难题,提出风电场中性点柔性接地方式,理论推导获得柔性接地风电场三序等效电路,与集电线路单相接地故障复合序网模型,建立风电场零序电压柔性调控理论,提出集电线路单相接地故障柔... 为解决风电场集电系统长期存在的线路单相接地故障处理难题,提出风电场中性点柔性接地方式,理论推导获得柔性接地风电场三序等效电路,与集电线路单相接地故障复合序网模型,建立风电场零序电压柔性调控理论,提出集电线路单相接地故障柔性电压消弧方法,可主动将故障点电压及故障残流迅速抑制到零,实现单相接地故障电弧的可靠消除。进一步提出基于零序电流动态增量的高阻故障辨识与保护方法,通过柔性调控零序补偿电流,逐渐放大故障残流,实现永久性单相接地故障的灵敏感知与保护。利用PSCAD/EMTDC搭建含双馈异步风电机(doubly-fedinduction generator,DFIG)的规模化风电场模型,模拟多种运行与故障条件对所提方法进行验证,仿真结果表明,该方法能够在考虑系统不平衡电压的情况下精准调控集电线路故障点电压,实现瞬时性单相接地故障快速可靠消弧,动态感知并持续抑制永久性单相接地故障残流,实现集电线路高阻接地故障的灵敏保护。该技术有望提升风电场运行灵活性与故障防御能力,有力保障新能源电能外送的持续性、可靠性。 展开更多
关键词 集电线路 柔性接地 单相接地故障 电压消弧 动态保护
下载PDF
Remediation of electric arc furnace dust leachate by the use of cementitious materials: A column-leaching test
11
作者 Josee Duchesne Guylaine Laforest 《Chinese Journal Of Geochemistry》 EI CAS 2006年第B08期99-99,共1页
关键词 工业固体废物 环境管理 微量元素 电弧炉
下载PDF
架空配电线路故障电弧的电磁辐射特性及故障定位应用 被引量:3
12
作者 杨庆 齐玥 +2 位作者 韦思宇 王科 刘红文 《中国电机工程学报》 EI CSCD 北大核心 2024年第1期353-361,I0029,共10页
针对架空配电线路电弧接地故障点定位难题,该文研究架空配电线路故障电弧的电磁辐射特性,探索基于电磁辐射信号的电弧故障定位方法的可行性。通过10 k V配网真型故障模拟试验平台,分析接地电弧电磁辐射的时域与频域特性及传播衰减规律,... 针对架空配电线路电弧接地故障点定位难题,该文研究架空配电线路故障电弧的电磁辐射特性,探索基于电磁辐射信号的电弧故障定位方法的可行性。通过10 k V配网真型故障模拟试验平台,分析接地电弧电磁辐射的时域与频域特性及传播衰减规律,结果表明:电弧电流的电磁辐射特征频段为20~30 MHz,该特征频段不会受到中性点接地方式、电弧接地介质与线路结构参数的显著影响,且特征频段内辐射信号在传播过程中衰减较慢。在此基础上,设计一种小型化三角形单极子–环形组合平面天线,工作频率为20~500 MHz。利用自制天线开展小型电弧故障定位实验,为后续配网电弧故障定位的应用研究提供基础。 展开更多
关键词 架空配电线路 接地电弧 电磁辐射 时域特性 频域特性 故障定位
下载PDF
基于发电机定子接地燃弧电阻变化特征的主动降压熄弧机理与抑制方法
13
作者 李理 喻锟 +2 位作者 曾祥君 王沾 贺世庚 《电工技术学报》 EI CSCD 北大核心 2024年第17期5379-5393,共15页
定子接地燃弧故障是制约大型发电机安全可靠运行的技术瓶颈。为解决定子绕组接地电弧引发的绝缘击穿与铁心损伤问题,该文提出基于发电机定子接地燃弧电阻变化特征的柔性接地主动降压熄弧方法。该文建立了定子接地燃弧电阻与弧道电压的... 定子接地燃弧故障是制约大型发电机安全可靠运行的技术瓶颈。为解决定子绕组接地电弧引发的绝缘击穿与铁心损伤问题,该文提出基于发电机定子接地燃弧电阻变化特征的柔性接地主动降压熄弧方法。该文建立了定子接地燃弧电阻与弧道电压的解析关系,揭示了定子接地故障点电压降低过程中,接地燃弧电阻增大的变化规律;明确了将接地故障点电压抑制在电弧重燃电压以下时,可实现定子绕组击穿间隙回归正常绝缘状态的抑制方法。根据大型发电机定子柔性接地方式降压熄弧策略,在接地故障燃弧阶段,中性点电压源输出故障点工频与3次谐波反向电势,主动降低故障点电压,将故障点电压降低至燃弧电压以下,使定子接地电弧熄灭。利用注入信号感知定子接地燃弧状态,实时监测定子阻尼率矢量角变化趋势,判定降压消弧过程中接地燃弧故障是否消除。所提方法无需将故障点电压降低至零,可有效降低非故障相电压抬升,降低定子非故障相绕组槽内击穿风险。在PSCAD/EMTDC仿真环境模拟定子接地故障燃弧工况,对所提方法进行试验验证。试验结果表明,基于定子接地燃弧电阻变化特征的柔性接地消弧方法可主动降低定子接地故障点电压,助增故障点间隙绝缘电阻回归,抑制接地电弧重燃,降低定子非故障相绝缘击穿风险,实现定子接地燃弧故障的可靠消弧。 展开更多
关键词 发电机定子 弧光接地故障 主动降压消弧 弧道电阻 故障感知
下载PDF
基于零序特征参量差异的谐振接地系统熄弧时刻判别方法
14
作者 张帆 薛永端 +2 位作者 仉志华 乔东伟 徐丙垠 《电网技术》 EI CSCD 北大核心 2024年第1期343-351,共9页
在谐振接地系统中,熄弧时刻的准确判别对于接地故障的选线、消弧效果评估以及熄弧后暂态信息提取和利用具有指导意义。该文针对谐振接地系统单相接地故障,分析了故障点工频电流熄弧前后的故障电气特征,并利用母线零序电压和消弧线圈电流... 在谐振接地系统中,熄弧时刻的准确判别对于接地故障的选线、消弧效果评估以及熄弧后暂态信息提取和利用具有指导意义。该文针对谐振接地系统单相接地故障,分析了故障点工频电流熄弧前后的故障电气特征,并利用母线零序电压和消弧线圈电流,通过求取其信号的一阶导数及其平方信号的二阶导数,构造两种特征参量。研究发现该特征参量在熄弧前为常数,熄弧后发生明显变化,据此可形成相应的熄弧时刻判别的基本判据。考虑到系统实际运行中各种因素的影响,在此基础上形成熄弧时刻判别的附加判据,从而最终提出基于零序特征参量差异的谐振接地系统熄弧时刻判别方法。通过Mat Lab/Simulink仿真和现场实测,验证了该熄弧时刻判别方法的有效性和准确性。 展开更多
关键词 谐振接地系统 接地故障 特征参量 熄弧时刻
下载PDF
融合灭弧信息的有源串联接地配电网故障检测方法
15
作者 刘宝稳 万子雄 +1 位作者 曾祥君 马宏忠 《电网技术》 EI CSCD 北大核心 2024年第11期4767-4776,I0090-I0095,I0089,共17页
为了优化有源全补偿消弧设备和挖掘灭弧状态信息包含的故障特征,该文提出基于串联分压的配电网消弧原理及融合灭弧状态信息的接地故障检测方法。提出采用单个H桥变流器与消弧线圈串联的有源降压消弧全补偿方法和灵活接入保护电容的有源... 为了优化有源全补偿消弧设备和挖掘灭弧状态信息包含的故障特征,该文提出基于串联分压的配电网消弧原理及融合灭弧状态信息的接地故障检测方法。提出采用单个H桥变流器与消弧线圈串联的有源降压消弧全补偿方法和灵活接入保护电容的有源消弧装置保护方案,在消弧原理与控制、设备承压与安全、功率输出与过压防护等方面表现出良好性能。提出融合有源降压消弧全补偿“伪正常”状态信息的接地故障检测方法,利用系统正常-故障-灭弧3种状态信息构造故障检测判据,在免受过渡电阻和分布参数不对称影响的基础上优化故障检测方式和提高故障检测效率,无需线路间信息的横向比较即可实现系统全域零序导纳测量、故障馈线独立判别和故障程度跟踪识别。仿真实验证实了方法的有效性,为优化配电网有源消弧和接地故障检测提供创新方案。 展开更多
关键词 有源消弧 串联分压 接地故障检测 改进零序导纳法 灭弧信息
下载PDF
故障相桥臂转移接地消弧装置直流侧电压控制方法
16
作者 郭谋发 刘鑫斌 +2 位作者 张彬隆 赵国军 郑泽胤 《电力系统保护与控制》 EI CSCD 北大核心 2024年第19期1-14,共14页
为解决传统三相直挂式柔性消弧装置非故障相桥臂承担线电压的问题,提出一种故障相桥臂转移接地的消弧方法。该方法通过开关控制故障相桥臂转移接地,母线电压由故障相桥臂与非故障相桥臂共同承担,三相桥臂共同输出电流,以实现消弧。针对... 为解决传统三相直挂式柔性消弧装置非故障相桥臂承担线电压的问题,提出一种故障相桥臂转移接地的消弧方法。该方法通过开关控制故障相桥臂转移接地,母线电压由故障相桥臂与非故障相桥臂共同承担,三相桥臂共同输出电流,以实现消弧。针对级联H桥直流侧需独立供电的问题,提出分布式电压平衡换流调制方法。该调制方法根据H桥输出状态和电流方向对直流侧电容充放电的影响,有选择地改变H桥的输出状态,进而实现直流侧电压的稳定。使用该调制方法的消弧装置无须在直流侧配备独立供电电源,在消弧过程中能保持H桥直流侧电压稳定。最后,采用Matlab/Simulink仿真软件对所提方法进行验证,仿真结果证明了所提方法的有效性。 展开更多
关键词 单相接地故障 级联H桥变流器 直流侧电压 消弧 转移接地
下载PDF
圆弧式地基合成孔径雷达在边坡变形监测中的应用
17
作者 向泽君 李超 滕明星 《北京测绘》 2024年第2期270-276,共7页
边坡变形监测是防止滑坡、崩塌、泥石流等地质灾害的有效途径之一。圆弧式地基合成孔径雷达是一种非接触式的新型地表形变监测设备,具有高分辨率、高频率、高精度、全方位、全天候实时监测等优点,更能有效地满足边坡变形监测的全面性和... 边坡变形监测是防止滑坡、崩塌、泥石流等地质灾害的有效途径之一。圆弧式地基合成孔径雷达是一种非接触式的新型地表形变监测设备,具有高分辨率、高频率、高精度、全方位、全天候实时监测等优点,更能有效地满足边坡变形监测的全面性和连续性要求。为了验证该设备在边坡变形监测中的效果和精度,本文采用两种便携圆弧式地基合成孔径雷达系统进行测试。测试结果表明,两种设备均能快速、全面地获得整个边坡的形变情况,具有较高的分辨率和亚毫米级的监测精度,且能实时发出预警,是一种全面高效的边坡变形监测手段。 展开更多
关键词 边坡 变形监测 圆弧式 地基合成孔径雷达
下载PDF
配电网间歇性重燃电弧模型的建立与断续弧光接地故障特征分析研究 被引量:2
18
作者 张彪 周申培 +4 位作者 吴细秀 侯博文 侯慧 邱进 丁心志 《电网技术》 EI CSCD 北大核心 2024年第5期2207-2217,I0116-I0120,共16页
电弧间歇性重燃是配电网单相接地故障最显著的特征。现有的电弧模型甚少考虑电弧间歇性重燃特性,导致无法精确描述断续弧光接地特征,进而影响继电保护动作。为此,论文提出一种间歇性重燃电弧模型的建立方法,并在此基础上对断续弧光接地... 电弧间歇性重燃是配电网单相接地故障最显著的特征。现有的电弧模型甚少考虑电弧间歇性重燃特性,导致无法精确描述断续弧光接地特征,进而影响继电保护动作。为此,论文提出一种间歇性重燃电弧模型的建立方法,并在此基础上对断续弧光接地故障特征进行了分析。弧道阻抗的随机变化是电弧间歇性重燃的重要标志,故论文重点围绕弧道阻抗变化的随机性和重燃时间间隔的随机性开展间歇性重燃电弧模型的研究。黑盒电弧模型中,Cassie-Mayr联合模型能完整的描述电弧电流从大电流到小电流的变化过程,但存在从大电流变化为小电流的判据模糊,转换过程突变的问题。为此,论文通过引入连续过渡函数解决上述问题。同时,为描述弧道电阻的变化特性,利用Fermi函数对联合模型中Mayr模型和Cassie模型进行权重分配。以改进的Cassie-Mayr单次燃弧模型为基础,根据工频熄弧理论,通过设置燃弧时间长短表征间歇性重燃的随机性,从而建立了间歇性重燃电弧模型。利用该模型,对典型10kV配电网单辐射型网架结构的接地故障进行模拟仿真,采用快速傅里叶变换(fast Fourier transform,FFT)和小波包分析提取了不同条件下故障电压、电流、高次谐波、零序分量以及频率分布等故障特征。研究结果表明:改进后Cassie-Mayr联合模型不但解决了电弧电流从大电流到小电流的转换突变问题,且不同模型权重占比的分配更能准确地表征实际燃弧弧道阻抗变化的随机性;通过设置电弧燃弧时间长短,准确地描述间歇性重燃的随机性;电弧断续时刻为非整数周期下的过电压、过电流幅值高于整数周期;电缆线路增大了故障线路电流,过电流可达3.81~7.20pu,不利于熄弧;大电流系统故障相零序电流主频在0~400Hz,小电流系统故障相零序电流主频在1200~1600Hz。 展开更多
关键词 配电网 单相接地故障 间歇性重燃电弧模型 中性点接地 小波包分析
下载PDF
基于动态电阻串联的高阻接地故障精确建模 被引量:2
19
作者 钟逸涵 邓丰 +2 位作者 史鸿飞 徐帆 李鑫瑜 《电工技术学报》 EI CSCD 北大核心 2024年第7期2046-2059,共14页
现有各类高阻接地故障模型缺乏对故障发展全过程的物理解释,难以准确模拟故障的非线性特征。该文根据现场录波数据,深入研究高阻接地故障的物理过程,归纳可知故障电流波形的非线性畸变来源于两个方面:空气间隙击穿引起的非线性与接地介... 现有各类高阻接地故障模型缺乏对故障发展全过程的物理解释,难以准确模拟故障的非线性特征。该文根据现场录波数据,深入研究高阻接地故障的物理过程,归纳可知故障电流波形的非线性畸变来源于两个方面:空气间隙击穿引起的非线性与接地介质本身的非线性。据此提出高阻接地故障的故障电阻由电弧电阻和接地电阻串联组成,进而建立基于动态电阻串联的高阻接地故障新模型。首先,利用汤逊原理分析空气介质击穿过程中动态电弧的产生,建立了故障点指数电弧模型;然后,研究故障电流在土壤中的流散过程,结合土壤电阻率变化规律,求解接地电阻随故障电流变化的表达式,建立接地电阻模型;最后,在PSCAD中将二者串联,搭建高阻接地故障新模型,结合现场故障数据并与其他模型对比,验证了该文所提模型能更准确地表征不同接地介质下高阻接地故障的非线性特征,为后续研究高阻接地故障辨识提供更精确的数据支撑。 展开更多
关键词 配电网 高阻接地故障 电弧电阻 接地电阻 非线性特征
下载PDF
大型发电机定子接地故障柔性融合消弧方法
20
作者 黄俊杰 郭谋发 张彬隆 《电网技术》 EI CSCD 北大核心 2024年第11期4748-4757,共10页
大型发电机发生定子单相接地故障可能会产生电弧,导致铁心烧损,甚至引发火灾等严重事故,提出一种柔性融合消弧方法,通过并行控制中性点电压和变流器注入电流,实现接地故障电流抑制和可靠消弧。现有发电机定子单相接地柔性消弧方法在低... 大型发电机发生定子单相接地故障可能会产生电弧,导致铁心烧损,甚至引发火灾等严重事故,提出一种柔性融合消弧方法,通过并行控制中性点电压和变流器注入电流,实现接地故障电流抑制和可靠消弧。现有发电机定子单相接地柔性消弧方法在低阻或高阻的情况下消弧效果不佳,所提方法考虑了发电机的定子阻抗和定子并联分支数,适用于不同的发电机,在不同接地故障过渡电阻、不同故障位置等情况下,均能够将接地故障电流快速抑制到安全范围内。Matlab/Simulink仿真验证了所提方法的有效性。 展开更多
关键词 大型发电机 定子接地故障 柔性消弧 电压消弧 电流消弧 融合消弧
下载PDF