Fault protection method of single-phase break for distribution network considering the influence of neutral grounding modes 被引量:29
1
作者 Yang Xiao Jinxin Ouyang +2 位作者 Xiaofu Xiong Yutong Wang Yongjie Luo 《Protection and Control of Modern Power Systems》 2020年第1期111-123,共13页
With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equi... With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability. 展开更多
关键词 Distribution network single-phase break fault protection Neutral grounding
原文传递
Over Voltage Fault due to Disconnection of Consumer’s Transformer Neutral Wire
2
作者 Erdene Adiyasuren Enkh-Od Erdene +1 位作者 Sergelen Byambaa Shagdarsuren Gantumur 《Journal of Energy and Power Engineering》 2023年第1期11-14,共4页
Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected fr... Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected from the neutral of power supply source,then there will be some trouble and failure occurred.The current in the neutral wire drops down to zero when the neutral wire is cut off and the phase currents of all three-phase equal to each other since there was no return wire.The currents are equal but the voltages at the phase consumers are different.Especially for residential single-phase consumers,the voltage at the consumers of the phase varies differently for three phase systems when the neutral wire was disconnected at consumer side and even the voltage at the consumers one or two of those three phases becomes over nominal voltage or reaches nearly line voltage.In this case,the electronic appliances in that phase will be fed by high voltage than the rated value and they can be broken down.In the power system of UB(Ulaanbaatar)city,there are some occasional such kind of failures every year.Obviously,many electronic appliances were broken down due to high voltage and the electricity utility companies respond for service charge of damaged parts. 展开更多
关键词 Neutral connection and neutral wire phase and line voltage single-phase residential consumer transformer neutral cut off asymmetric load current protective earth