Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
1
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire
下载PDF
Transient Fault Locating Method Based on Line Voltage and Zero-mode Current in Non-solidly Earthed Network 被引量:48
2
作者 ZHANG Linli XU Bingyin +1 位作者 XUE Yongduan GAO Houlei 《中国电机工程学报》 EI CSCD 北大核心 2012年第13期I0015-I0015,198,共1页
为解决配电网小电流接地故障时故障点定位困难的问题,提出一种基于线电压和零模电流暂态分量的故障定位新方法。该方法借助馈线自动化(feeder automation,FA)系统实现,不需要额外增加设备。馈线终端检测线电压和零模电流信号,利... 为解决配电网小电流接地故障时故障点定位困难的问题,提出一种基于线电压和零模电流暂态分量的故障定位新方法。该方法借助馈线自动化(feeder automation,FA)系统实现,不需要额外增加设备。馈线终端检测线电压和零模电流信号,利用暂态线电压的希尔伯特变换与暂态零模电流的乘积计算故障方向参数,FA主站根据故障点前后方向参数极性相反的特征确定故障点所在的线路区段。介绍基于线电压的小电流接地故障检测和接地故障相确定的算法。数字仿真与试验结果表明该方法是正确可行的。 展开更多
关键词 低压配电网络 瞬态故障 定位方法 接地电流 线电压 非直接接地系统 单相接地故障 馈线自动化
下载PDF
Method of Fault Area & Section Location for Non-solidly Earthed Distribution System 被引量:28
3
作者 ZHENG Guping JIANG Chao LI Gang QI Zheng YANG Yihan 《中国电机工程学报》 EI CSCD 北大核心 2012年第13期I0014-I0014,197,共1页
中国中压配电网以架空线为主,多为小电流系统,单相接地故障占到电网故障总数的80%以上,但中国配网自动化系统基本上没有小电流接地故障定位功能,使配网自动化系统在提高可靠性的作用上大打折扣。给出一种小电流接地故障区段定位新... 中国中压配电网以架空线为主,多为小电流系统,单相接地故障占到电网故障总数的80%以上,但中国配网自动化系统基本上没有小电流接地故障定位功能,使配网自动化系统在提高可靠性的作用上大打折扣。给出一种小电流接地故障区段定位新方法,在线路上配置广域相量测量固定测点,获取小电流电网单相接地故障特征信息。基于测点相邻矩阵区段起始测点标识向量和故障路径标识向量概念,提出确定故障区间边界节点算法。物理模拟实验和挂网测试表明:该故障分区分段定位方法能够在线求解小电流接地故障段边界节点,缩小线路维护巡视范围。确定故障区间边界节点算法还可用于确定故障区相关负荷开关,为线路维护和馈线自动化提供依据。 展开更多
关键词 断层破碎带 配电自动化系统 单相接地故障 小电流系统 小电流接地 架空线路 电压分布 故障监测
下载PDF
Correlation Studies of Rare Earth Elements in Syntectonic Intrusions of Strike-Slip Stage along Southern Segment of Tan-Lu Fault Zone 被引量:2
4
作者 牛漫兰 朱光 +1 位作者 刘国生 宋传中 《Journal of Rare Earths》 SCIE EI CAS CSCD 2005年第1期108-111,共4页
Intrusions in the Zhangbaling uplift zone and the eastern margin of the Dabie orogenic belt belong to the syntectonic intrusions developed during the strike-slip stage in the southern segment of the Tan-Lu fault zone.... Intrusions in the Zhangbaling uplift zone and the eastern margin of the Dabie orogenic belt belong to the syntectonic intrusions developed during the strike-slip stage in the southern segment of the Tan-Lu fault zone. However, characteristics of rare earth elements show that intrusions in the Zhangbaling uplift zone have the characteristics of mantle source type and those in the eastern margin of Dabie belt are the typical crust source type. Therefore, Au-deposits related to the intrusions in the Zhangbaling uplift zone are developed better than those in the eastern margin of the Dabieshan. The research results of the rare earth elements coincide with the studies of geophysics, tectonic setting and stable isotope. It is further indicated that the rare earth elements offer effective approach to tracing the material sources of magmatic rocks. 展开更多
关键词 GEOCHEMISTRY INTRUSION Tan-Lu fault zone rare earths
下载PDF
Co-seismic Coulomb stress changes on the northern Tanlu fault zone caused by the Tohoku-Oki M_(W)9.0 earthquake 被引量:1
5
作者 Fei Chen Tai Liu +2 位作者 Yawen She Xing Huang Guangyu Fu 《Earthquake Science》 2020年第1期11-22,共12页
Based on the spherical earth dislocation theory and a fault slip model of the Tohoku-Oki M_(W)9.0 earthquake,the co-seismic Coulomb failure stress changes(ΔCFS)on the northern Tanlu fault zone at depths of 0–40 km a... Based on the spherical earth dislocation theory and a fault slip model of the Tohoku-Oki M_(W)9.0 earthquake,the co-seismic Coulomb failure stress changes(ΔCFS)on the northern Tanlu fault zone at depths of 0–40 km are calculated.By comparing two sets of results from the spherical earth dislocation theory and the semi-infinite space one,the effect of earth curvature on the calculation results is analyzed quantitatively.First,we systematically summarize previous researches related to the northern Tanlu fault zone,divide the fault zone as detailed as possible,give the geometric parameters of each segment,and establish a segmented structural model of the northern Tanlu fault zone.Second,we calculate the Coulomb stress changes on the northern Tanlu fault zone by using the spherical earth dislocation theory.The result shows the Coulomb stress changes are no more than 0.003 MPa,which proves the great earthquake did not significantly change the stress state of the fault zone.Finally,we quantitatively analyze the disparities between the results of semi-infinite space dislocation theory and the spherical earth one.The average disparity between them is about 7.7%on the northern Tanlu fault zone and is 16.8%on the Fangzheng graben,the maximum disparity on this graben reaches up to 25.5%.It indicates that the effect of earth curvature can not be ignored.So it’s necessary to use the spherical earth dislocation theory instead of the semi-infinite space one to study the Coulomb stress change in the far field. 展开更多
关键词 the northern Tanlu fault zone segmented structural model spherical earth dislocation theory the Tohoku-Oki M_(W)9.0 earthquake co-seismic Coulomb stress change(△CFS)
下载PDF
An evidence for earthquake ocurence time related with geologic structure──Relations between local mean lunar times of earthquake ocurence and their fault trends
6
作者 陈荣华 丁鉴海 丁香 《Acta Seismologica Sinica(English Edition)》 CSCD 1997年第1期79-84,共6页
The relation between the local mean lunar time τ of earthquake occurrence and their fault trends is studied in this paper. The local mean lunar times τ of 53 earthquakes in 24 groups are calculated. Because ... The relation between the local mean lunar time τ of earthquake occurrence and their fault trends is studied in this paper. The local mean lunar times τ of 53 earthquakes in 24 groups are calculated. Because the tidal generation force arisen by the moon is a cyclic function of about 12 hours 25 minutes in the main, the two tidal generation forces anywhere in the earth arising by the moon are equal in general when the moon lies to the two sites of 180° interval of local mean lunar time. Based on this phenomenon the values Δ τ of τ 1- τ 2 or τ 1-τ 2±180° of two earthquakes occurring repetitiously in the same place are also calculated. The calculated results show that if the fault trends of the two earthquakes in the same place is near, the Δ τ is usually smaller and if the fault trends of the two ones is not near, the Δ τ is usually larger and the distribution of the local mean lunar time τ of earthquakes in different places is dispersive even if fault trends of these earthquakes are near, and the τ does not concentrate on the lower and upper transit of the moon. The above phenomena clear up that the triggering earthquake of earth solid tide arisen by the moon is relative with the fault trends of earthquakes and we ought to think over the difference of environmental conditions of earthquake preparation of each seismogenic zone and can not make statistics to earthquakes in different places when we study the relation between the solid earth tide arisen by the moon and earthquakes. 展开更多
关键词 fault trend earth tide earthquake triggering
下载PDF
A New Transient Impedance-Based Algorithm for Earth Fault Detection in Medium Voltage Networks 被引量:1
7
作者 Mohamed F. Abdel-Fattah Matti Lehtonen 《Journal of Energy and Power Engineering》 2012年第2期240-249,共10页
This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient im... This paper presents a new earth-fault detection algorithm for unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm is based on capacitance calculation from transient impedance and dominant transient frequency. The Discrete Fourier Transform (DFT) method is used to determine the dominant transient frequency. The values of voltage and current earth modes are calculated in the period of the dominant transient frequency, then the transient impedance can be determined, from which we can calculate the earth capacitance. The calculated capacitance gives an indication about if the feeder is faulted or not. The algorithm is less dependent on the fault resistance and the faulted feeder parameters; it mainly depends on the background network. The network is simulated by ATP/EMTP program. Several different fault conditions are covered in the simulation process, different fault inception angles, fault locations and fault resistances. 展开更多
关键词 earth faults earth capacitance transient impedance transient frequency unearthed and compensated MV networks.
下载PDF
A Novel Transient Current-Based Differential Algorithm for Earth Fault Detection in Medium Voltage Distribution Networks
8
作者 Mohamed F. Abdel-Fatta Matti Lehtonen 《Journal of Energy and Power Engineering》 2012年第1期81-88,共8页
This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transien... This paper presents a novel transient current differential algorithm for earth fault detection in unearthed (isolated) and compensated neutral medium voltage (MV) networks. The proposed algorithm uses the transient residual currents, which are very sensitive for earth faults detection. The transient values of residual currents are calculated for each feeder in the network and used as an earth fault indicator. The flow of residual currents is investigated. It is found that the residual current for the faulted feeder is equal to the summation of all residual currents for all other healthy feedersl Based on this investigation, a differential technique is proposed. A percentage restrain performance is proposed to ensure the selectivity and security of the algorithm. The transient algorithm is very sensitive for earth fault incidence. To apply the proposed algorithm, the residual currents can be measured easily by one sensor for each feeder with no need to voltage measurement. The proposed algorithm is less dependent on the fault resistance and the faulted feeder parameters. The network is simulated by ATP/EMTP program. Different fault conditions are covered in the simulation process: different fault inception angles, fault locations and fault resistances. 展开更多
关键词 earth faults earth capacitance transient impedance transient frequency unearthed and compensated MV networks.
下载PDF
Google Earth在野外初步断裂调查中的应用 被引量:7
9
作者 姚生海 李文巧 《高原地震》 2009年第1期64-66,共3页
主要介绍了卫星影像技术及Google Earth的特点,通过工程实例说明了Google Earth作为卫星影像在野外断裂调查中发挥的作用,总结了Google Earth卫星影像的优劣。
关键词 GOOGLE earth 卫星影像 断裂调查
下载PDF
基于Google Earth的浑河断裂带遥感影像解译分析 被引量:1
10
作者 万波 丁浩 王超 《防灾减灾学报》 2020年第4期1-8,共8页
遥感解译分析是断裂调查和活动性研究的重要工作内容,通过清晰、完整的断裂线性影像判读并结合实际验证调查能够获得断裂构造展布、结构、规模和活动特征等多方面的参数。浑河断裂带发育于沈阳、抚顺及其以东的辽东山地,其Google Earth... 遥感解译分析是断裂调查和活动性研究的重要工作内容,通过清晰、完整的断裂线性影像判读并结合实际验证调查能够获得断裂构造展布、结构、规模和活动特征等多方面的参数。浑河断裂带发育于沈阳、抚顺及其以东的辽东山地,其Google Earth卫星数据分辨率可以达到1~2.5m至亚米级,客观上提供了进行浑河断裂带遥感解译分析的条件。分析表明,浑河断裂带可以划分为沈阳段、抚顺段、章党—南杂木段和南杂木—英额门东段等4个不同的断裂段,除沈阳段以外,其它各段均表现出清晰的断裂线性特征,对于微地貌形态具有比较明确的反映。抚顺段和南杂木—英额门东段均控制了浑河河谷的发育,但不同的是,抚顺段北支较之南支规模更大、活动性更强,章党—南杂木段和南杂木—英额门东段影像可辨识度较高,微地貌变化稳定、连续,可能具有较新的第四纪活动性。 展开更多
关键词 浑河断裂带 Google earth 遥感解译 线性影像 盆地 第四纪 地貌 活动性
下载PDF
Process of source dynamics of the Jingtai earthquake (M=6. 2 ) 被引量:4
11
作者 杜学彬 闫志德 邹明武 《Acta Seismologica Sinica(English Edition)》 CSCD 1994年第3期379-388,共10页
In this paper, the process of source dynamics of the Jingtai earthquake (M= 6. 2) is studied on the basis of both earth resistivity changes before the event and the spatial directivity of single-observatory magnitude ... In this paper, the process of source dynamics of the Jingtai earthquake (M= 6. 2) is studied on the basis of both earth resistivity changes before the event and the spatial directivity of single-observatory magnitude measurements of the seismic network of China. The following conclusions are obtained: the NW-SE directional tension stress (or the one about in the direction) inside the source region was enhanced during the short period from three to five months before the event, and done still further about in twenty odd days before the event, so that it finally leads the fault in about the EW strike to produce dislocation in NWW-SEE direction. Finally, this dislocation pattern caused the strong ground vibration to be received at the seismic observatories which were located in the NWW and SEE directions of the epicenter, while the weak vibration to be received at the ones in NE and south directions of the epicenter. At last, understandings on the imminent earthquake prediction through earth resistivity method are set forth. 展开更多
关键词 earth resistivity magnitude measurement active fault
下载PDF
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
12
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
Design and Testing of Three Earthing Systems for Micro-Grid Protection during the Islanding Mode 被引量:2
13
作者 Rashad M. Kamel Aymen Chaouachi Ken Nagasaka 《Smart Grid and Renewable Energy》 2010年第3期132-142,共11页
This paper presents and tests three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types when the MG transferred to the islanding mode. The main contribution of this work is incl... This paper presents and tests three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types when the MG transferred to the islanding mode. The main contribution of this work is including the models of all micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included with the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the islanding mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current pro-tection relays. With using TN earthing system, touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited values during islanding mode. For the two others earthing systems (TT and IT), fault currents are small and nearly equal to the over load currents which make over current protection relay can not differentiate between fault currents and overload currents. All models of micro sources, earthing systems, inverters and control schemes are built using Matlab?/Simulink? environment. 展开更多
关键词 MICRO Grid PROTECTION earthING SYSTEMS fault Current Touch Voltage MICRO Sources and INVERTERS
下载PDF
Comparison the Performances of Three Earthing Systems for Micro-Grid Protection during the Grid Connected Mode 被引量:2
14
作者 Rashad Mohammedeen Kamel Aymen Chaouachi Ken Nagasaka 《Smart Grid and Renewable Energy》 2011年第3期206-215,共10页
This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the ... This paper presents, tests and compares three earthing systems (TT, TN and IT) for Micro-Grid (MG) protection against various fault types during the connected mode. The main contribution of this work is including the models of all the micro sources which interfaced to the MG by power electronic inverters. Inverters in turns are provided with current limiters and this also included in the inverter models to exactly simulate the real situation in the MG during fault times. Results proved that the most suitable earthing system for MG protection during the connecting mode is the TN earthing system. That system leads to a suitable amount of fault current sufficient to activate over current protection relays. With using TN system, Touch voltages at the faulted bus and all other consumer’s buses are less than the safety limited value if current limiter is included with the transformer of the main grid which connects MG. For the two others earthing systems (TT and IT), fault current is small and nearly equal to the over load current which make over current protection relay can not differentiate between fault current and overload current. All models of micro sources, earthing systems, inverters, main grid and control schemes are built using Matlab?/Simulink? environment. 展开更多
关键词 MICRO GRID PROTECTION earthING SYSTEMS fault Current Touch Voltage MICRO Sources and Inverters GRID Connecting MODE
下载PDF
Multisphere Tectonics of the Earth System 被引量:1
15
作者 REN Jishun NIU Baogui +5 位作者 XU Qinqin ZHAO Lei LIU Jianhui LI Shan ZHU Junbin LIU Renyan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2022年第3期727-741,共15页
The fundamental theoretical framework of the Multisphere Tectonics of the Earth System is as follows:(1)It intends to extend the geotectonic studies from the crustal and lithospheric tectonics to the multisphere tecto... The fundamental theoretical framework of the Multisphere Tectonics of the Earth System is as follows:(1)It intends to extend the geotectonic studies from the crustal and lithospheric tectonics to the multisphere tectonics of the Ear th system as a whole.(2)The global dynamics driven by both the Earth system and the cosmic celestial system:solar energy,multispheric interactions of the Earth system and the combined effects of the motions of celestial bodies in the cosmos syste m are the driving forces of various geological processes.(3)The Continent-Ocean transformation theory:the continent and ocean are two opposite yet unified geological units,which can be transformed into each other;neither continent nor ocean wi ll survive forever;there is no one-way development of continental accretion or ocean extinction;the simple theory of one-way continental accretion is regarded as invalid.(4)The continental crust and mantle are characterized by multiple layers,with different layers liable to slide along the interfaces between them,but corroboration is needed that continents move as a who le or even drift freely.(5)The cyclic evolution theory:the development of Earth’s tectonics is not a uniform change,but a spiral forward evolution,characterized by a combination of non-uniform,non-linear,gradual and catastrophic changes;different evolutionary stages(tectonic cycles)of Earth have distinctive global tectonic patterns and characteristics,one tectonic mo del should not be applied to different tectonic cycles or evolutionary stages.(6)The structure and evolution of Earth are asymmetric and heterogeneous,thus one tectonic model cannot be applied to different areas of the world.(7)The polycyclic evolution of the continental crust:the continental crust is formed by polycyclic tectonics and magmatism,rather than simply lateral or vertical accretion.(8)The role of deep faults:the deep fault zones cutting through different layers of the crus t a nd mantle usually play important roles in tectonic evolution.For example,the present-day mid-ocean ridge fault zones,transform fault zones and Benioff zones outline the global tectonic framework.Different tectonic cycles and stages of Earth’s evolutio n must have their own distinctive deep fault systems which control the global tectonic framework and evolutionary processes during different tectonic cycles and stages.Starting from the two mantle superplumes Jason(Pacific)and Tuzo(Africa),the study of the evolutionary process of the composition and structure of the crust and mantle during the great transformation an d reorganization of the Meso-Cenozoic tectonic framework in China and the other regions of Asia is a good demonstration of theory of Multisphere Tectonics of the Earth System. 展开更多
关键词 deep fault global dynamics cyclic evolution theory Multisphere Tectonics Continent-Ocean transformation theory earth system science
下载PDF
Characteristics and factors that influenced damage to dams in the M_s 8.0 Wenchuan earthquake 被引量:7
16
作者 Jing Liping Liang Haian Li Yongqiang Liu Chunhui 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第3期349-358,共10页
Based on raw data from dams damaged in the Wenchuan earthquake, including many that were severely damaged, characteristics and factors that influenced the damage are discussed in this paper. Findings from this study i... Based on raw data from dams damaged in the Wenchuan earthquake, including many that were severely damaged, characteristics and factors that influenced the damage are discussed in this paper. Findings from this study include: severely damaged dams were densely distributed along the seismologic fault; small dams, especially small earth-rock dams, had the most serious damage that was caused by a variety of factors; the most serious damage was caused by seismic waves; damage was aggregated by aftershocks; and the extent of the damage patterns increased with the seismic intensity. Damage patterns varied in different intensity zones and cracking was the most common type of damage. Most of the dams had a good base with relatively high bearing capacity, and the walls of the earth-rock dams were mostly of clay soil. This type of base and body material mitigated some of the damage to dams. Reservoir maintenance and other factors also have a significant impact on the seismic safety of the dam. Finally, some recommendations to reduce seismic damage to dams are proposed. 展开更多
关键词 seismic damage DAM characteristic of damage to dams influencing factors Wenchuan earthquake seismologic fault earth-rock dams
下载PDF
Line Faults in Gd_5Si_2Ge_2-Type Phase
17
作者 Fu Hao Chen Yungui Zhang Tiebang Tu Mingjing 《Journal of Rare Earths》 SCIE EI CAS CSCD 2005年第4期I0012-I0012,共1页
Gd5Si2Ge2.2 alloy was synthesized by arcmelting and its phase components, microstructure, and especially the line features were investigated by X- ray diffraction (XRD), scanning-electron microscope (SEM), energy-... Gd5Si2Ge2.2 alloy was synthesized by arcmelting and its phase components, microstructure, and especially the line features were investigated by X- ray diffraction (XRD), scanning-electron microscope (SEM), energy-dispersive spectroscopy (EDS), and transmission-electron microscope (TEM). Gd5Si2Ge2.2 consists of Gd5Si2Ge2-type and GdGe-type phases and presents eutectic characteristics. There are many regular line features on the Gd5Si2Ge2-type phase according to SEM. EDS shows that the line feature is not the Gd5 (Si,Ge)3-type phase because Gd content decreases at the line features. Two types of line features are found in the fine microstructure of Gd5Si2Ge2-type phase by TEM. Selected area diffraction (SAD) confirms that both line features are not the secondary phase or twins. There is no changes observed in the microstructure of Gd5Si2Ge2 2 from room temperature to 1400 ℃ with in situ high temperature optical microscope, therefore, it is deduced that the line features observed by SEM are formed during the solidification. 展开更多
关键词 Gd-Si-Ge alloys magnetic refrigerating materials microstructure faults rare earths
下载PDF
Research on Fault-feeder Selection Dvice
18
作者 Ziming Zhuo Haimeng Sun Haibin Ji 《Energy and Power Engineering》 2013年第4期937-940,共4页
The compensation current of the arc-suppressing coil makes the phase and amplitude of zero-sequence measurement current of the earthed fault feeder to vary. It is very hard to detect the fault feeder by using existing... The compensation current of the arc-suppressing coil makes the phase and amplitude of zero-sequence measurement current of the earthed fault feeder to vary. It is very hard to detect the fault feeder by using existing detectors based on single method. In this paper, integrative feeder selection strategy—zero sequence current increment method and the direction of transient current— is put forward. Based on the integrative feeder selection strategy, the design of fault-feeder selection device for one-phase-to ground fault on resonance grounding system is presented. For the purpose of testing and validating the operating principle of the device, the experiment of single-phase-to-ground fault has been carried out on the simulation of 1.2 kV power network. The results from many repeat experiments show that stability of the fault selection device is satisfactory. 展开更多
关键词 Resonance GROUNDING System earthed fault FEEDER Detection Zero-Sequence Current INCREMENT Method Zero-sequence Transient Currents
下载PDF
Fast Fault Isolation and Restoration of Looped MV Network
19
作者 马士聪 徐丙垠 高厚磊 《Transactions of Tianjin University》 EI CAS 2008年第2期148-152,共5页
A new fault isolation and restoration technique employing local Ethemet network for the looped MV circuit is presented. It can isolate all short circuit faults in the loop within 300 ms and restore the supply of healt... A new fault isolation and restoration technique employing local Ethemet network for the looped MV circuit is presented. It can isolate all short circuit faults in the loop within 300 ms and restore the supply of healthy sections in less than 1.2 s. A reliable fault location method of isolating the single phase-to-ground fault (SPGF) in the non-effectively earthed network, which makes use of the fault generated transient signals, is also proposed. And the method locates the SPGF by examining transient zero-mode current correlation, which is not influenced by the neutral grounding mode and need no additional device. Laboratory test and simulation results show the proposed techniques are feasible, and significantly improve the supply reliability. 展开更多
关键词 fault isolation and restoration non-effectively earthed neutral system transient zero-mode current optical fibre Ethernet
下载PDF
Google Earth在电力通信光缆管理中的应用 被引量:7
20
作者 倪子强 胡传明 《电力系统通信》 2008年第2期50-53,共4页
介绍利用GOOGLE提供的免费的全球卫星图像软件Google Earth来绘制地区电力光缆路径的方法,用此方法可以获得及时更新的路径资料,便于了解光缆地理环境,并实现光缆故障定位。
关键词 电力通信光缆 故障定位 GOOGLE earth 卫星图像
下载PDF