750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and step...750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and steps of 6 characteristic parameters for grounding device of 750 kV substation by using 8000S comprehensive test system, and scientifically judged overall performance of the grounding device. Moreover, we espe- cially emphasized key and difficult points in testing process, providing reference for the majority of grounding test workers.展开更多
The paper discusses the system function, structure of hardware and software of the ground simulating testing system for airborne electronic devices; an example of a practical simulation and inspection system is given....The paper discusses the system function, structure of hardware and software of the ground simulating testing system for airborne electronic devices; an example of a practical simulation and inspection system is given. The system connects different kinds of microcomputers as DIMENSION 68000. SDK86, TP80T to form a distributed simulation and inspection network through an 8-terminal optic fiber communication net. The system can imitate the signal of the radar of a motional object and the ARINC429 signal of the navigation subsystem and atmosphere subsystem. It can be directly connected to the airborne electronic devices, receiving and processing real-time data from the airborne electronic devices, storing the data, fulfilling error analysis, drawing curves of the motive objects, printing tables of various test parameters. The system is easy to operate with perfect functions. The technique index accomplished and appraisal of the system are also given.展开更多
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select...In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.展开更多
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground...The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.展开更多
HVDC transmission system has considerable impact on the surrounding power transformers when the system is running in the unipolar ground mode, which will cause the DC magnetic biasing phenomenon on transformers. This ...HVDC transmission system has considerable impact on the surrounding power transformers when the system is running in the unipolar ground mode, which will cause the DC magnetic biasing phenomenon on transformers. This problem would be more serious, after commission and operation of UHVDC transmission system in China. According to the Guangdong power grid under the influence of DC magnetic bias seriously, but little research about the using of blocking device, this paper proposed an optimization scheme about the usage of blocking device combination. Firstly, the subject studied the method of suppressing transformer neutral point DC depending on analysis the mechanism of magnetic biasing, and then found out the changes of power grid after using the capacitance blocking device which is popular used by Guangdong power grid. The particle swarm optimization (PSO) has been used to find a better way to suppress the DC in power grid, and combined with NSGA to solve the mixed integer programming problem. The final data validation of this method is valuable in engineering application.展开更多
The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition...The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition to pose a threat for health, the rise of the short circuit, as a consequence of insulation faults, poses a threat to retirement of electric systems and fire risks. The reliable grounding system design has significant implications for protection of human being as well as for electrical facility protection. The set objective was performed on the base of analytical and software-based methods. Analytical method gives a qualitative indication at each step in analysis. It also allows evaluating the values effect on the result, but the method is not susceptible of tolerable accuracy, that is why analytical method serves as initial approximation in differentiating. Specified estimation can be performed in such software package as MATLAB or ETAP. Software-based estimation is based on the finite element method (FEM), the main advantage of which is the ability to create different forms of grounding and allows obtaining distribution graphs of the step potential on the earth’s surface and touch potential. The calculation results in comparison of analytical and software-based methods taking into account the grounding optimization. There are conclusions on the most effective ground network.展开更多
Grounding devices are significant to the operation of the power transmission line and power equipment.The soil and leakage current can easily cause the corrosion of carbon steel grounding devices,resulting in power ac...Grounding devices are significant to the operation of the power transmission line and power equipment.The soil and leakage current can easily cause the corrosion of carbon steel grounding devices,resulting in power accidents.Therefore,most carbon steel grounding devices in service are already corroded,and the accurate calculation of grounding parameters for corroded grounding devices is important.However,most existing methods for calculating the grounding parameters of corroded grounding devices usually have the following disadvantages:1)They only consider whether the grounding devices are broken or not,and cannot analyze the grounding parameters of grounding devices with different corrosion degrees;2)They assume that the corroded grounding device is a conductor with a smaller diameter,and ignore the impact of the corrosion product layer,resulting in calculation errors.To solve the above problems,this paper establishes an accurate corrosion model for grounding devices based on the volume expansion coefficient of corrosion products.The grounding parameters calculation method for corroded grounding devices is proposed based on the boundary element method(BEM)and Galerkin’s method.Then the grounding performance of tower grounding grids with different corrosion degrees in different soils(uniform and layered)is analyzed.Finally,some features of grounding parameters of corroded grounding devices are given.This study can accurately calculate the grounding parameters of the corroded grounding devices and has far-reaching engineering significance for the safety of power equipment.展开更多
文摘750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and steps of 6 characteristic parameters for grounding device of 750 kV substation by using 8000S comprehensive test system, and scientifically judged overall performance of the grounding device. Moreover, we espe- cially emphasized key and difficult points in testing process, providing reference for the majority of grounding test workers.
文摘The paper discusses the system function, structure of hardware and software of the ground simulating testing system for airborne electronic devices; an example of a practical simulation and inspection system is given. The system connects different kinds of microcomputers as DIMENSION 68000. SDK86, TP80T to form a distributed simulation and inspection network through an 8-terminal optic fiber communication net. The system can imitate the signal of the radar of a motional object and the ARINC429 signal of the navigation subsystem and atmosphere subsystem. It can be directly connected to the airborne electronic devices, receiving and processing real-time data from the airborne electronic devices, storing the data, fulfilling error analysis, drawing curves of the motive objects, printing tables of various test parameters. The system is easy to operate with perfect functions. The technique index accomplished and appraisal of the system are also given.
文摘In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.
基金This paper is supported in part by the National Natural Science Foundations of China,and the Major Science and Technology Projects in Yunnan Province under Grant Nos.51667010,51807085,and 202002AF080001.
文摘The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.
文摘HVDC transmission system has considerable impact on the surrounding power transformers when the system is running in the unipolar ground mode, which will cause the DC magnetic biasing phenomenon on transformers. This problem would be more serious, after commission and operation of UHVDC transmission system in China. According to the Guangdong power grid under the influence of DC magnetic bias seriously, but little research about the using of blocking device, this paper proposed an optimization scheme about the usage of blocking device combination. Firstly, the subject studied the method of suppressing transformer neutral point DC depending on analysis the mechanism of magnetic biasing, and then found out the changes of power grid after using the capacitance blocking device which is popular used by Guangdong power grid. The particle swarm optimization (PSO) has been used to find a better way to suppress the DC in power grid, and combined with NSGA to solve the mixed integer programming problem. The final data validation of this method is valuable in engineering application.
文摘The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition to pose a threat for health, the rise of the short circuit, as a consequence of insulation faults, poses a threat to retirement of electric systems and fire risks. The reliable grounding system design has significant implications for protection of human being as well as for electrical facility protection. The set objective was performed on the base of analytical and software-based methods. Analytical method gives a qualitative indication at each step in analysis. It also allows evaluating the values effect on the result, but the method is not susceptible of tolerable accuracy, that is why analytical method serves as initial approximation in differentiating. Specified estimation can be performed in such software package as MATLAB or ETAP. Software-based estimation is based on the finite element method (FEM), the main advantage of which is the ability to create different forms of grounding and allows obtaining distribution graphs of the step potential on the earth’s surface and touch potential. The calculation results in comparison of analytical and software-based methods taking into account the grounding optimization. There are conclusions on the most effective ground network.
基金supported by the Fundamental Research Funds for the Central Universities(grant no.2019CDXYDQ0010)the National Key Research and Development Program of China(grant no.2017YFB0902701)the National Natural Science Foundation of China(grant no.51577017).
文摘Grounding devices are significant to the operation of the power transmission line and power equipment.The soil and leakage current can easily cause the corrosion of carbon steel grounding devices,resulting in power accidents.Therefore,most carbon steel grounding devices in service are already corroded,and the accurate calculation of grounding parameters for corroded grounding devices is important.However,most existing methods for calculating the grounding parameters of corroded grounding devices usually have the following disadvantages:1)They only consider whether the grounding devices are broken or not,and cannot analyze the grounding parameters of grounding devices with different corrosion degrees;2)They assume that the corroded grounding device is a conductor with a smaller diameter,and ignore the impact of the corrosion product layer,resulting in calculation errors.To solve the above problems,this paper establishes an accurate corrosion model for grounding devices based on the volume expansion coefficient of corrosion products.The grounding parameters calculation method for corroded grounding devices is proposed based on the boundary element method(BEM)and Galerkin’s method.Then the grounding performance of tower grounding grids with different corrosion degrees in different soils(uniform and layered)is analyzed.Finally,some features of grounding parameters of corroded grounding devices are given.This study can accurately calculate the grounding parameters of the corroded grounding devices and has far-reaching engineering significance for the safety of power equipment.