This paper proposes and implements a model-free open-loop iterative learning control(ILC)strategy to realize the speed control of the single-phase flux switching motor(FSM)with an asymmetrical rotor.Base on the propos...This paper proposes and implements a model-free open-loop iterative learning control(ILC)strategy to realize the speed control of the single-phase flux switching motor(FSM)with an asymmetrical rotor.Base on the proposed winding control method,the asymmetrical rotor enables the motor to generate continuous positive torque for positive rotation,and relatively small resistance torque for negative rotation.An initial iteration coefficient and variable iteration coefficient optimized scheme was proposed based on the characteristics of the hardware circuit,thereby forming the model-free strategy.A series of prototype experiments was carried out.Experimental results verify the effectiveness and practicability of the proposed ILC strategy.展开更多
Single-phase multiferroic materials are usually considered useless because of the weak magnetoelectric effects,low operating temperature,and small electric polarization induced by magnetic orders.As a result,current s...Single-phase multiferroic materials are usually considered useless because of the weak magnetoelectric effects,low operating temperature,and small electric polarization induced by magnetic orders.As a result,current studies on applications of the magnetoelectric effects are mainly focusing on multiferroic heterostructures and composites.Here we report a room-temperature giant effect in response to external magnetic fields in single-phase multiferroics.A low magnetic field of 1000 Oe applied on the spin-driven multiferroic hexaferrites BaSrCo_(2) Fe_(11)AlO_(22) and Ba_(0.9)Sr_(1.1)Co_(2) Fe_(11)AlO_(22)is able to cause a huge change in the linear magnetoelectric coefficient(α_(E)=dE/dH) by several orders,leading to a giant magnetotranstance(GMT) effect at room temperature.The GMT effect is comparable to the well-known giant magnetoresistance(GMR) effect in magnetic multilayers,and thus opens up a door toward practical applications for single-phase multiferroics.展开更多
Magneto-electro-elastic(MEE)materials are a specific class of advanced smart materials that simultaneouslymanifest the coupling behavior under electric,magnetic,and mechanical loads.This unique combination ofpropertie...Magneto-electro-elastic(MEE)materials are a specific class of advanced smart materials that simultaneouslymanifest the coupling behavior under electric,magnetic,and mechanical loads.This unique combination ofproperties allows MEE materials to respond to mechanical,electric,and magnetic stimuli,making them versatile forvarious applications.This paper investigates the static and time-harmonic field solutions induced by the surface loadin a three-dimensional(3D)multilayered transversally isotropic(TI)linear MEE layered solid.Green’s functionscorresponding to the applied uniform load(in both horizontal and vertical directions)are derived using the FourierBessel series(FBS)system of vector functions.By virtue of this FBS method,two sets of first-order ordinarydifferential equations(i.e.,N-type and LM-type)are obtained,with the expansion coefficients being Love numbers.It is noted that the LM-type system corresponds to the MEE-coupled P-,SV-,and Rayleigh waves,while the N-typecorresponds to the purely elastic SH-and Love waves.By applying the continuity conditions across interfaces,the solutions for each layer of the structure(from the bottom to the top)are derived using the dual-variable andposition(DVP)method.This method(i.e.,DVP)is unconditionally stable when propagating solutions throughdifferent layers.Numerical examples illustrate the impact of load types,layering,and frequency on the response ofthe structure,as well as the accuracy and convergence of the proposed approach.The numerical results are usefulin designing smart devices made of MEE solids,which are applicable to engineering fields like renewable energy.展开更多
The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results sho...The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results show that the Mg-1.5Zn-0.6Zr alloy had a single-phase solid solution structure,with an average grain size of 34.7±13.1μm.The alloy exhibited ultimate tensile strength of 168±2.0 MPa,yield strength of 83±0.6 MPa,and elongation of 9.1±0.6%.Immersion tests and electrochemical measurements reveal that the alloy displayed lower biocorrosion rate and more uniform corrosion mode than AZ91D in Hank's solution.The elimination of intensive galvanic corrosion reactions and the formation of a much more compact and uniform corrosion film mainly account for the better biocorrosion properties of the Mg-1.5Zn-0.6Zr alloy than AZ91D.展开更多
A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reacti...A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reaction time, initial molybdenum concentration, initial NH_3 /Mo molar ratio, and stirring speed. Under the optimum experimental conditions, the crystallization rate of product is 85.23%. The X-ray diffraction (XRD) analysis and chemical analysis show that the product is single-phase ammonium dimolybdate, and no impurity phases exist. The scanning electronic microscope (SEM) image reveals uniform particle size, good particle dispersion, and no agglomeration between particles. Meanwhile, the final pH value of acidification was investigated. The total molybdenum recovery can reach up to 99.40%, and the main phases of acidification product are the same as those of raw material with the final pH value of 1.5. This determines that the acidification product can be used as a raw material to produce single-phase ammonium dimolybdate.展开更多
Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops ...Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops of CBM column from well head to bottom hole.The measured parameters and independent variables of flow rates,flowing pressures and temperatures are involved in CBM producing process along the annulus.The developed relationships are validated against full-scale measured data in single-phase CBM wellbores.The proposed methodology can analyze the dynamic behavior in CBM reservoir and process of CBM flow with an overall accuracy of 2%.The calculating process of flowing pressures involves friction factor with variable Reynolds number and CBM temperature and compressibility factor with gravitational gradients.The results showed that the effect of flowing pressure on CBM column was more obvious than that on CBM and water column accompanied by an increase of dynamic water level.The ratios of flowing pressure on increment of CBM column to the whole column increased with the declined flow rates of water column.Bottom-hole pressure declined with the decreased flowing pressure of CBM column along the annulus.It will lead to the results of the increased pressure drop of CBM column and CBM flow rate in single-phase CBM wellbores.展开更多
Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were estab...Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.展开更多
Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling ...Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling is responsible for 40%of the usage.Therefore,this research proposes the immersion cooling method to solving the high energy consumption of data centers by cooling its component using two types of dielectric fluids.Four stages of experimentalmethods are used,such as fluid types,cooling effectiveness,optimization,and durability.Furthermore,benchmark software is used to measure the CPU maximum work with the temperature data performed for 24 h.The results of this study show that the immersion cooling reduces 13℃ lower temperature than the conventional cooling method which means it saves more energy consumption in the data center.The most optimum variable used to decrease the temperature is 1.5 lpm of flow rate and 800 rpm of fan rotation.Furthermore,the cooling performance of the dielectric fluids shows that the mineral oil(MO)is better than the virgin coconut oil(VCO).In durability experiment,there are no components damage after five months immersed in the fluid.展开更多
Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and contr...Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.展开更多
The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational pri...The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.展开更多
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th...According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.展开更多
A single-phase lattice Boltzmann model with modified surface tension is developed in this paper to solve the problem of high-density-ratio free surface flow.The computational efficiency and accuracy are both enhanced....A single-phase lattice Boltzmann model with modified surface tension is developed in this paper to solve the problem of high-density-ratio free surface flow.The computational efficiency and accuracy are both enhanced.The restriction to the relaxation factor (which needs to be smaller than 1) is circumvented by the new surface tension algebra,due to its rational physical nature compared with the treatment of Xing,Buther and Yang in their paper (Comp.Mater.Sci.,2007,39(2):282-290).The proposed stable surface tension scheme is applied to simulate the free deformation of a square droplet with surface tension effect and the process of a droplet impinging on a liquid film.The numerical solution for free deformation of a droplet agrees well with thermodynamic principles,and also achieves high accuracy in comparison with Xing,et al.'s model.Three typical impinging modes are successfully obtained with the new scheme,and another particular mode found by Wang and Chen is also successfully simulated.The evolutions of liquid crown agree well with the power law related to time.展开更多
To avoid stray current and maintain the benefit of no phase-split in the DC traction power supply system, an AC traction power supply system was proposed for the urban public transport such as metro and light rail tra...To avoid stray current and maintain the benefit of no phase-split in the DC traction power supply system, an AC traction power supply system was proposed for the urban public transport such as metro and light rail transit. The proposed system consists of a main substation (MSS) and cable traction network (CTN). The MSS includes a single-phase main traction transformer and a negative-se- quence compensation device, while the CTN includes double-core cables, traction transformers, overhead catenary system, rails, etc. Several key techniques for the proposed system were put forward and discussed, which can be summarized as (1) the power supply principle, equivalent circuit and transmission ability of the CTN, the cable-catenary matching technique, and the selection of catenary voltage level; (2) the segmentation technology and status identification method for traction power supply network, distributed and centralized protection schemes, etc.; (3) a power supply scheme for single-line MSS and a power supply scheme of MSS shared by two or more lines. The proposed industrial frequency single-phase AC traction power supply system shows an excellent technical performance, good economy, and high reliability, hence provides a new alternative for metro and urban rail transit power supply systems.展开更多
It was reported that both dielectricity and magnetism at room temperature were appreciably improved in Bi4Fe2TiO12 film compared with Bi4Fe2TiO12 bulk. X-ray diffraction profiles reveal similar crystalline nature and ...It was reported that both dielectricity and magnetism at room temperature were appreciably improved in Bi4Fe2TiO12 film compared with Bi4Fe2TiO12 bulk. X-ray diffraction profiles reveal similar crystalline nature and random orientation of the two, but X-ray photoelectron spectroscopy (XPS) experiments indicate that it is 1.4 eV lower binding energy of core-state Ols in the film relative to that of the bulk, so the improvement of multiferroics in the film is attributed to oxygen vacancies and high fraction of interface. The results have promising applications in multifunctional integrated devices.展开更多
The high quality single-phase solution of CO2/ Polystyrene was achieved,by analyzing the influential factors for polymer microcellular foaming extrusion.The curve of pressure distribution along the barrel was determin...The high quality single-phase solution of CO2/ Polystyrene was achieved,by analyzing the influential factors for polymer microcellular foaming extrusion.The curve of pressure distribution along the barrel was determined.The axial position of gas-injecting port on the barrel was chosen form the results of stable foaming,and the number of gas-injecting ports in the circumference of the barrel was determined from the CO2 solubility in polymer.The effect of the screw rotation speed on CO2 solubility was studied,and the effects of pressure difference between the gas and the polymer melt on gas-injecting process and on the foaming stability were investigated.The influence of the gas temperature before injection on the single-phase of CO2/Polystyrene solution also was studied.展开更多
A depth-averaged quasi single-phase mixture model is proposed for debris flows over inclined bed slopes based on the shallow water hydrosediment-morphodynamic theory with multi grain sizes. The stresses due to fluctua...A depth-averaged quasi single-phase mixture model is proposed for debris flows over inclined bed slopes based on the shallow water hydrosediment-morphodynamic theory with multi grain sizes. The stresses due to fluctuations are incorporated based on analogy to turbulent flows, as estimated using the depth-averaged k-? turbulence model and a modification component. A fully conservative numerical algorithm, using wellbalanced slope limited centred scheme, is deployed to solve the governing equations. The present quasi single-phase model using four closure relationships for the bed shear stresses is evaluated against USGS experimental debris flow and compared with traditional quasi single-phase models and a recent physically enhanced two-phase model. It is found that the present quasi single-phase model performs much better than the traditional models, and is attractive in terms of computational cost while the two-phase model performs even better appreciably.展开更多
Important in many different sectors of the industry, the determination of stream velocity has become more and more important due to measurements precision necessity, in order to determine the right production rates, d...Important in many different sectors of the industry, the determination of stream velocity has become more and more important due to measurements precision necessity, in order to determine the right production rates, determine the volumetric production of undesired fluid, establish automated controls based on these measurements avoiding over-flooding or over-production, guaranteeing accurate predictive maintenance, etc. Difficulties being faced have been the determination of the velocity of specific fluids embedded in some others, for example, determining the gas bubbles stream velocity flowing throughout liquid fluid phase. Although different and already applicable methods have been researched and already implemented within the industry, a non-intrusive automated way of providing those stream velocities has its importance, and may have a huge impact in projects budget. Knowing the importance of its determination, this developed script uses a methodology of breaking-down real-time videos media into frame images, analyzing by pixel correlations possible superposition matches for further gas bubbles stream velocity estimation. In raw sense, the script bases itself in functions and procedures already available in MatLab, which can be used for image processing and treatments, allowing the methodology to be implemented. Its accuracy after the running test was of around 97% (ninety-seven percent);the raw source code with comments had almost 3000 (three thousand) characters;and the hardware placed for running the code was an Intel Core Duo 2.13 [Ghz] and 2 [Gb] RAM memory capable workstation. Even showing good results, it could be stated that just the end point correlations were actually getting to the final solution. So that, making use of self-learning functions or neural network, one could surely enhance the capability of the application to be run in real-time without getting exhaust by iterative loops.展开更多
A method of feedforward compensation for electromotive force(EMF) in the single-phase permanent magnet linear generation system and a research in the performance of the single-phase PMLG system are presented.A general...A method of feedforward compensation for electromotive force(EMF) in the single-phase permanent magnet linear generation system and a research in the performance of the single-phase PMLG system are presented.A general mathematical model for the single-phase permanet magnet linear generator(PMLG) system is established and the current loop,voltage loop and the feedforward control are studied based on it for the control system.Then this paper analyses the transfer function of the power system,optimizes current loop and voltage loop parameters by engineering algorithm,and calculates the optimal control parameters.An EMF feedforward compensation method is developed to optimize the control system which improves dynamic performance of the power system but does not affect the steady-state performance.The result of this research verifies the correctness and rationality of the design for the control system.展开更多
In this paper, we have proposed a class of mixture regression-cum-ratio estimator for estimating population mean by using information on multiple auxiliary variables and attributes simultaneously in single-phase sampl...In this paper, we have proposed a class of mixture regression-cum-ratio estimator for estimating population mean by using information on multiple auxiliary variables and attributes simultaneously in single-phase sampling and analyzed the properties of the estimator. An empirical was carried out to compare the performance of the proposed estimator with the existing estimators of finite population mean using simulated population. It was found that the mixture regression-cum-ratio estimator was more efficient than ratio and regression estimators using one auxiliary variable and attribute, ratio and regression estimators using multiple auxiliary variables and attributes and regression-cum-ratio estimators using multiple auxiliary variables and attributes in single-phase sampling for finite population.展开更多
This paper discusses a novel boost single-phase active AC-DC converters, named low-end semi-controlled bridge AC-DC converter. By analysis, its topology and principle can be derived from the conventional single-phase ...This paper discusses a novel boost single-phase active AC-DC converters, named low-end semi-controlled bridge AC-DC converter. By analysis, its topology and principle can be derived from the conventional single-phase power factor corrector ( PFC). But it has also some differences, such as power device positions, inductor type, input voltage waveform detection and induction current detection, so its design is also different. The converter is implemented by employing two current detection approaches, i.e., current transformer detection and shunt resistor detection. Consequently, it can provide a steady DC output voltage with a low voltage ripple, approximately unitary input power factor and 2.5 kW output power. The experimental results show validity of the theoretical analysis.展开更多
文摘This paper proposes and implements a model-free open-loop iterative learning control(ILC)strategy to realize the speed control of the single-phase flux switching motor(FSM)with an asymmetrical rotor.Base on the proposed winding control method,the asymmetrical rotor enables the motor to generate continuous positive torque for positive rotation,and relatively small resistance torque for negative rotation.An initial iteration coefficient and variable iteration coefficient optimized scheme was proposed based on the characteristics of the hardware circuit,thereby forming the model-free strategy.A series of prototype experiments was carried out.Experimental results verify the effectiveness and practicability of the proposed ILC strategy.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51725104, and 11534015)the National Key Research and Development Program of China (Grant No. 2016YFA0300700)the Beijing Natural Science Foundation (Grant No. Z180009)。
文摘Single-phase multiferroic materials are usually considered useless because of the weak magnetoelectric effects,low operating temperature,and small electric polarization induced by magnetic orders.As a result,current studies on applications of the magnetoelectric effects are mainly focusing on multiferroic heterostructures and composites.Here we report a room-temperature giant effect in response to external magnetic fields in single-phase multiferroics.A low magnetic field of 1000 Oe applied on the spin-driven multiferroic hexaferrites BaSrCo_(2) Fe_(11)AlO_(22) and Ba_(0.9)Sr_(1.1)Co_(2) Fe_(11)AlO_(22)is able to cause a huge change in the linear magnetoelectric coefficient(α_(E)=dE/dH) by several orders,leading to a giant magnetotranstance(GMT) effect at room temperature.The GMT effect is comparable to the well-known giant magnetoresistance(GMR) effect in magnetic multilayers,and thus opens up a door toward practical applications for single-phase multiferroics.
基金The National Science and Technology Council of Taiwan(Grant No.NSTC 111-2811-E-516 A49-534)provided financial support for this study。
文摘Magneto-electro-elastic(MEE)materials are a specific class of advanced smart materials that simultaneouslymanifest the coupling behavior under electric,magnetic,and mechanical loads.This unique combination ofproperties allows MEE materials to respond to mechanical,electric,and magnetic stimuli,making them versatile forvarious applications.This paper investigates the static and time-harmonic field solutions induced by the surface loadin a three-dimensional(3D)multilayered transversally isotropic(TI)linear MEE layered solid.Green’s functionscorresponding to the applied uniform load(in both horizontal and vertical directions)are derived using the FourierBessel series(FBS)system of vector functions.By virtue of this FBS method,two sets of first-order ordinarydifferential equations(i.e.,N-type and LM-type)are obtained,with the expansion coefficients being Love numbers.It is noted that the LM-type system corresponds to the MEE-coupled P-,SV-,and Rayleigh waves,while the N-typecorresponds to the purely elastic SH-and Love waves.By applying the continuity conditions across interfaces,the solutions for each layer of the structure(from the bottom to the top)are derived using the dual-variable andposition(DVP)method.This method(i.e.,DVP)is unconditionally stable when propagating solutions throughdifferent layers.Numerical examples illustrate the impact of load types,layering,and frequency on the response ofthe structure,as well as the accuracy and convergence of the proposed approach.The numerical results are usefulin designing smart devices made of MEE solids,which are applicable to engineering fields like renewable energy.
基金This project was supported by the National Natural Science Foundation of China(No.51174025)Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20110006130004).
文摘The microstructure,mechanical property,and in vitro biocorrosion behavior of as-cast single-phase biodegradable Mg-1.5Zn-0.6Zr alloy were investigated and compared with a commercial as-cast AZ91D alloy.The results show that the Mg-1.5Zn-0.6Zr alloy had a single-phase solid solution structure,with an average grain size of 34.7±13.1μm.The alloy exhibited ultimate tensile strength of 168±2.0 MPa,yield strength of 83±0.6 MPa,and elongation of 9.1±0.6%.Immersion tests and electrochemical measurements reveal that the alloy displayed lower biocorrosion rate and more uniform corrosion mode than AZ91D in Hank's solution.The elimination of intensive galvanic corrosion reactions and the formation of a much more compact and uniform corrosion film mainly account for the better biocorrosion properties of the Mg-1.5Zn-0.6Zr alloy than AZ91D.
基金supported by the National Natural Science Foundation of China(No.51072233)
文摘A novel method for the preparation of single-phase ammonium dimolybdate with industrial ammonium molybdate was studied. Various in- fluential factors were evaluated in the paper, including reaction temperature, reaction time, initial molybdenum concentration, initial NH_3 /Mo molar ratio, and stirring speed. Under the optimum experimental conditions, the crystallization rate of product is 85.23%. The X-ray diffraction (XRD) analysis and chemical analysis show that the product is single-phase ammonium dimolybdate, and no impurity phases exist. The scanning electronic microscope (SEM) image reveals uniform particle size, good particle dispersion, and no agglomeration between particles. Meanwhile, the final pH value of acidification was investigated. The total molybdenum recovery can reach up to 99.40%, and the main phases of acidification product are the same as those of raw material with the final pH value of 1.5. This determines that the acidification product can be used as a raw material to produce single-phase ammonium dimolybdate.
基金This work was financially supported by National Science and Technology Major Project of the Ministry of Science and Technology of China(2016ZX05065-001),Key Research Project of Shandong Province(2019GHY112029 and 2019GSF109090)and Higher Education Research and Development Project of Shandong Province(J17KA033).
文摘Dynamic behavior of coalbed methane (CBM) flow will provide the theoretical basis to optimize production performance for a given well.A mathematical model is developed to simulate flowing pressures and pressure drops of CBM column from well head to bottom hole.The measured parameters and independent variables of flow rates,flowing pressures and temperatures are involved in CBM producing process along the annulus.The developed relationships are validated against full-scale measured data in single-phase CBM wellbores.The proposed methodology can analyze the dynamic behavior in CBM reservoir and process of CBM flow with an overall accuracy of 2%.The calculating process of flowing pressures involves friction factor with variable Reynolds number and CBM temperature and compressibility factor with gravitational gradients.The results showed that the effect of flowing pressure on CBM column was more obvious than that on CBM and water column accompanied by an increase of dynamic water level.The ratios of flowing pressure on increment of CBM column to the whole column increased with the declined flow rates of water column.Bottom-hole pressure declined with the decreased flowing pressure of CBM column along the annulus.It will lead to the results of the increased pressure drop of CBM column and CBM flow rate in single-phase CBM wellbores.
基金Project supported by the National Natural Science Foundation of China(Grant No.51107016)the National Basic Research Program of China(Grant No.2013CB035605)the Postdoctoral Science Research Developmental Foundation of Heilongjiang Province,China(Grant No.LHB-Q12086)
文摘Complex dynamical phenomenon was studied in the single phase H-bridge inverter which was controlled by either a peak current or a valley current. The state functions and the discrete iterative map equations were established to analyze the dynamical phenomenon in the single phase H-bridge inverter. The dynamical characteristics of the single phase H- bridge inverter, such as time domain waveform diagram, bifurcation diagram, and folding map, were obtained by using the numerical calculation when the circuit parameters varied in specific range. Moreover, the simulation results were obtained by using the OrCAD-PSpice software to validate the numerical calculation. Both the numerical calculation and the circuit simulation show that the symmetrical dynamical phenomenon occurs in the single phase H-bridge inverter controlled by the peak current or the valley current.
基金This work is financially supported by the Ministry of Research and Technology of Indonesia(BRIN)in the project called“Penggunaan Immersion Cooling untukMeningkatkan Efisiensi Energi Data Center”.
文摘Data centers are recognized as one of the most important aspects of the fourth industrial revolution since conventional data centers are inefficient and have dependency on high energy consumption,in which the cooling is responsible for 40%of the usage.Therefore,this research proposes the immersion cooling method to solving the high energy consumption of data centers by cooling its component using two types of dielectric fluids.Four stages of experimentalmethods are used,such as fluid types,cooling effectiveness,optimization,and durability.Furthermore,benchmark software is used to measure the CPU maximum work with the temperature data performed for 24 h.The results of this study show that the immersion cooling reduces 13℃ lower temperature than the conventional cooling method which means it saves more energy consumption in the data center.The most optimum variable used to decrease the temperature is 1.5 lpm of flow rate and 800 rpm of fan rotation.Furthermore,the cooling performance of the dielectric fluids shows that the mineral oil(MO)is better than the virgin coconut oil(VCO).In durability experiment,there are no components damage after five months immersed in the fluid.
基金This work is funded by the Anhui Natural Science Foundation Project of China(under Grant KJ2016A201)the National Natural Science Foundation of China(under Grant 11774378).
文摘Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.
基金Project (No. 50477033) supported by the National Natural ScienceFoundation of China
文摘The new 6-switch single-phase 5-level current-source inverter proposed in this paper was developed by properly simplifying the traditional 8-switch single-phase 5-level current-source inverter, and its operational principle was analyzed. Just like the problem of voltage-unbalance between different levels existing in voltage-source multilevel inverters, a similar problem of current-unbalance between different levels whether for the 8-switch single-phase 5-level current-source inverter, or for the new 6-switch 5-level current-source inverter also exists. A simple current-balance control method via DC current feedback is presented here to implement the current-balance control between different levels. And to reduce the output current harmonics, PWM control technique was used. Simulation and experimental results showed that this new 6-switch topology operates correctly and that the balance-inductor can almost equally distribute the total DC current.
文摘According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.
基金supported by the National Natural Science Foundation of China (Grant Nos.10625210,50609020 and 10902070)the Leading Academic Discipline Project of Shanghai Municipal Education Commission (Grant No.J50501)
文摘A single-phase lattice Boltzmann model with modified surface tension is developed in this paper to solve the problem of high-density-ratio free surface flow.The computational efficiency and accuracy are both enhanced.The restriction to the relaxation factor (which needs to be smaller than 1) is circumvented by the new surface tension algebra,due to its rational physical nature compared with the treatment of Xing,Buther and Yang in their paper (Comp.Mater.Sci.,2007,39(2):282-290).The proposed stable surface tension scheme is applied to simulate the free deformation of a square droplet with surface tension effect and the process of a droplet impinging on a liquid film.The numerical solution for free deformation of a droplet agrees well with thermodynamic principles,and also achieves high accuracy in comparison with Xing,et al.'s model.Three typical impinging modes are successfully obtained with the new scheme,and another particular mode found by Wang and Chen is also successfully simulated.The evolutions of liquid crown agree well with the power law related to time.
文摘To avoid stray current and maintain the benefit of no phase-split in the DC traction power supply system, an AC traction power supply system was proposed for the urban public transport such as metro and light rail transit. The proposed system consists of a main substation (MSS) and cable traction network (CTN). The MSS includes a single-phase main traction transformer and a negative-se- quence compensation device, while the CTN includes double-core cables, traction transformers, overhead catenary system, rails, etc. Several key techniques for the proposed system were put forward and discussed, which can be summarized as (1) the power supply principle, equivalent circuit and transmission ability of the CTN, the cable-catenary matching technique, and the selection of catenary voltage level; (2) the segmentation technology and status identification method for traction power supply network, distributed and centralized protection schemes, etc.; (3) a power supply scheme for single-line MSS and a power supply scheme of MSS shared by two or more lines. The proposed industrial frequency single-phase AC traction power supply system shows an excellent technical performance, good economy, and high reliability, hence provides a new alternative for metro and urban rail transit power supply systems.
文摘It was reported that both dielectricity and magnetism at room temperature were appreciably improved in Bi4Fe2TiO12 film compared with Bi4Fe2TiO12 bulk. X-ray diffraction profiles reveal similar crystalline nature and random orientation of the two, but X-ray photoelectron spectroscopy (XPS) experiments indicate that it is 1.4 eV lower binding energy of core-state Ols in the film relative to that of the bulk, so the improvement of multiferroics in the film is attributed to oxygen vacancies and high fraction of interface. The results have promising applications in multifunctional integrated devices.
基金Funded by the National Natural Science Foundation of China( No.19632004,No.10172074)the Research Foundation for the Doctor-al Program of Higher Education of China(No.98056113)the Natural Science Foundation of Guang-dong Province(No. 980573, No. 0401154)
文摘The high quality single-phase solution of CO2/ Polystyrene was achieved,by analyzing the influential factors for polymer microcellular foaming extrusion.The curve of pressure distribution along the barrel was determined.The axial position of gas-injecting port on the barrel was chosen form the results of stable foaming,and the number of gas-injecting ports in the circumference of the barrel was determined from the CO2 solubility in polymer.The effect of the screw rotation speed on CO2 solubility was studied,and the effects of pressure difference between the gas and the polymer melt on gas-injecting process and on the foaming stability were investigated.The influence of the gas temperature before injection on the single-phase of CO2/Polystyrene solution also was studied.
基金funded by Natural Science Foundation of China(Grants Nos.51279144 and 11432015)
文摘A depth-averaged quasi single-phase mixture model is proposed for debris flows over inclined bed slopes based on the shallow water hydrosediment-morphodynamic theory with multi grain sizes. The stresses due to fluctuations are incorporated based on analogy to turbulent flows, as estimated using the depth-averaged k-? turbulence model and a modification component. A fully conservative numerical algorithm, using wellbalanced slope limited centred scheme, is deployed to solve the governing equations. The present quasi single-phase model using four closure relationships for the bed shear stresses is evaluated against USGS experimental debris flow and compared with traditional quasi single-phase models and a recent physically enhanced two-phase model. It is found that the present quasi single-phase model performs much better than the traditional models, and is attractive in terms of computational cost while the two-phase model performs even better appreciably.
基金financial support from the Brazilian Federal Agency for Support and Evaluation of Graduate Education(Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior—CAPES,scholarship process no BEX 0506/15-0)the Brazilian National Agency of Petroleum,Natural Gas and Biofuels(Agencia Nacional do Petroleo,Gas Natural e Biocombustiveis—ANP),in cooperation with the Brazilian Financier of Studies and Projects(Financiadora de Estudos e Projetos—FINEP)the Brazilian Ministry of Science,Technology and Innovation(Ministério da Ciencia,Tecnologia e Inovacao—MCTI)through the ANP’s Human Resources Program of the State University of Sao Paulo(Universidade Estadual Paulista—UNESP)for the Oil and Gas Sector PRH-ANP/MCTI no 48(PRH48).
文摘Important in many different sectors of the industry, the determination of stream velocity has become more and more important due to measurements precision necessity, in order to determine the right production rates, determine the volumetric production of undesired fluid, establish automated controls based on these measurements avoiding over-flooding or over-production, guaranteeing accurate predictive maintenance, etc. Difficulties being faced have been the determination of the velocity of specific fluids embedded in some others, for example, determining the gas bubbles stream velocity flowing throughout liquid fluid phase. Although different and already applicable methods have been researched and already implemented within the industry, a non-intrusive automated way of providing those stream velocities has its importance, and may have a huge impact in projects budget. Knowing the importance of its determination, this developed script uses a methodology of breaking-down real-time videos media into frame images, analyzing by pixel correlations possible superposition matches for further gas bubbles stream velocity estimation. In raw sense, the script bases itself in functions and procedures already available in MatLab, which can be used for image processing and treatments, allowing the methodology to be implemented. Its accuracy after the running test was of around 97% (ninety-seven percent);the raw source code with comments had almost 3000 (three thousand) characters;and the hardware placed for running the code was an Intel Core Duo 2.13 [Ghz] and 2 [Gb] RAM memory capable workstation. Even showing good results, it could be stated that just the end point correlations were actually getting to the final solution. So that, making use of self-learning functions or neural network, one could surely enhance the capability of the application to be run in real-time without getting exhaust by iterative loops.
基金Supported by the National High Technology Research and Development Program of China(No.2006AA05Z231)the National Natural Science Foundation of China(No.51177025)
文摘A method of feedforward compensation for electromotive force(EMF) in the single-phase permanent magnet linear generation system and a research in the performance of the single-phase PMLG system are presented.A general mathematical model for the single-phase permanet magnet linear generator(PMLG) system is established and the current loop,voltage loop and the feedforward control are studied based on it for the control system.Then this paper analyses the transfer function of the power system,optimizes current loop and voltage loop parameters by engineering algorithm,and calculates the optimal control parameters.An EMF feedforward compensation method is developed to optimize the control system which improves dynamic performance of the power system but does not affect the steady-state performance.The result of this research verifies the correctness and rationality of the design for the control system.
文摘In this paper, we have proposed a class of mixture regression-cum-ratio estimator for estimating population mean by using information on multiple auxiliary variables and attributes simultaneously in single-phase sampling and analyzed the properties of the estimator. An empirical was carried out to compare the performance of the proposed estimator with the existing estimators of finite population mean using simulated population. It was found that the mixture regression-cum-ratio estimator was more efficient than ratio and regression estimators using one auxiliary variable and attribute, ratio and regression estimators using multiple auxiliary variables and attributes and regression-cum-ratio estimators using multiple auxiliary variables and attributes in single-phase sampling for finite population.
文摘This paper discusses a novel boost single-phase active AC-DC converters, named low-end semi-controlled bridge AC-DC converter. By analysis, its topology and principle can be derived from the conventional single-phase power factor corrector ( PFC). But it has also some differences, such as power device positions, inductor type, input voltage waveform detection and induction current detection, so its design is also different. The converter is implemented by employing two current detection approaches, i.e., current transformer detection and shunt resistor detection. Consequently, it can provide a steady DC output voltage with a low voltage ripple, approximately unitary input power factor and 2.5 kW output power. The experimental results show validity of the theoretical analysis.