Research on Inter-turn Short-circuit Fault Diagnosis Method Based on High Frequency Voltage Residual for PMSM
1
作者 Xiaobao Feng Bo Wang +2 位作者 Chaohui Liu Jiayun Zeng Zheng Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第3期256-265,共10页
Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of... Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of PMSM. Thus, an inter-turn short-circuit fault(ITSCF) diagnosis method based on high frequency(HF) voltage residual is proposed in this paper with proper HF signal injection. First, the analytical models of PMSM after the ITSCF are deduced. Based on the model, the voltage residual at low frequency(LF) and HF can be obtained. It is revealed that the HF voltage residual has a stronger ITSCF detection capability compared to the LF voltage residual. To obtain optimal fault signature, a 3-phase symmetrical HF voltage is injected into the machine drive system, and the HF voltage residuals are extracted. The fault indicator is defined as the standard deviation of the 3-phase HF voltage residuals. The effectiveness of the proposed ITSCF diagnosis method is verified by experiments on a triple 3-phase PMSM. It is worth noting that no extra hardware equipment is required to implement the proposed method. 展开更多
关键词 Inter-turn short-circuit fault(ITSCF) Permanent magnet synchronous machine(PMSM) High frequency(HF)injection Voltage residual fault diagnosis
下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
2
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire
下载PDF
Analysis on the fault characteristics of three-phase short-circuit for half-wavelength AC transmission lines 被引量:2
3
作者 Xuankun Song Teng Feng +4 位作者 Liu Han Travis MSmith Xinzhou Dong Wenxuan Liu Rui Zhang 《Global Energy Interconnection》 2018年第2期115-121,共7页
Half-wavelength AC transmission(HWACT) is an ultra-long distance AC transmission technology, whose electrical distance is close to half-wavelength at the system power frequency. It is very important for the constructi... Half-wavelength AC transmission(HWACT) is an ultra-long distance AC transmission technology, whose electrical distance is close to half-wavelength at the system power frequency. It is very important for the construction and operation of HWACT to analyze its fault features and corresponding protection technology. In this paper, the steady-state voltage and current characteristics of the bus bar and fault point and the steady-state overvoltage distribution along the line will be analyzed when a three-phase symmetrical short-circuit fault occurs on an HWACT line. On this basis, the threephase fault characteristics for longer transmission lines are also studied. 展开更多
关键词 Half-wavelength AC transmission fault characteristics Three-phase short-circuit fault distance OVERVOLTAGE
下载PDF
Short-circuit fault analysis and isolation strategy for matrix converters
4
作者 王莉娜 L.De Lillo +2 位作者 C.Brunson L.Empringham P.Wheeler 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第9期3458-3470,共13页
The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-... The behavior of matrix converter(MC) drive systems under the condition of MC short-circuit faults is comprehensively investigated. Two isolation strategies using semiconductors and high speed fuses(HSFs) for MC short-circuit faults are examined and their performances are compared. The behavior of MC drive systems during the fuse action time under different operating conditions is explored. The feasibility of fault-tolerant operation during the fuse action time is also studied. The basic selection laws for the HSFs and the requirements for the passive components of the MC drive system from the point view of short-circuit faults are also discussed. Simulation results are used to demonstrate the feasibility of the proposed isolation strategies. 展开更多
关键词 matrix converter short-circuit fault fault analysis fault behavior fault isolation
下载PDF
Remedial Phase-Angle Control of a Five-Phase Fault-Tolerant Permanent- Magnet Vernier Machine With Short-Circuit Fault 被引量:2
5
作者 Wenxiang Zhao Chenyu Gu +2 位作者 Qian Chen Jinghua Ji Dezhi Xu 《CES Transactions on Electrical Machines and Systems》 2017年第1期83-88,共6页
A fault-tolerant permanent-magnet vernier(FT-PMV)machine incorporates the merits of high fault-tolerant capability and high torque density.In this paper,a remedial phase-angle control(RPAC)strategy is proposed for a f... A fault-tolerant permanent-magnet vernier(FT-PMV)machine incorporates the merits of high fault-tolerant capability and high torque density.In this paper,a remedial phase-angle control(RPAC)strategy is proposed for a five-phase FT-PMV machine with short-circuit fault.Firstly,the proposed strategy can reduce the amount of unknown quantities by structuring the phase-angles of the normal phases.It can simplify the calculation of the remedial currents.Then,in order to obtain the desired torque,only the amplitudes of the remedial currents need to be calculated.Based on the principle of instantaneous electrical input power and mechanical output power balance condition,the real components are used to maintain the torque capability,while the reactive components are limited zero to minimize the torque ripple.Both simulations and experiments are presented to verify the proposed RPAC strategy. 展开更多
关键词 fault-tolerant permanent-magnet vernier(FT-PMV)machine remedial phase-angle control(RPAC) short-circuit fault.
下载PDF
Fast Single-phase Fault Location Method Based on Community Graph Depth-first Traversal for Distribution Network
6
作者 Jian Dang Yunjiang Yan +2 位作者 Rong Jia Xiaowei Wang Hui Wei 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第2期612-622,共11页
With the increasing complexity of distribution network structures originating from the high penetration of renewable energy and responsive loads,fast and accurate fault location technology for distribution networks is... With the increasing complexity of distribution network structures originating from the high penetration of renewable energy and responsive loads,fast and accurate fault location technology for distribution networks is a prerequisite for rapid isolation of faults and restoration of the power supply.In this paper,a fault location method based on community graph depth-first traversal is proposed for fast location of single-phase ground faults in distribution networks.First,this paper defines the fault graph weight of the vertices in the distribution network graph model,which can be used to reflect the topology of the vertices and fault points as well as the fluctuation of the vertices’currents.Then,the vertices on the graph model are clustered by using an improved parallel louvain method(IPLM).Finally,the community formed by IPLM is used as the smallest unit for depth-first traversal to achieve fast and accurate location of the fault section.The paper develops a distribution network graph model of IEEE 33-bus system on the graph database for testing.And three other methods are selected for comparison with IPLMDF.The test results show that IPLMDF can achieve fast and accurate fault location when half of the nodes in the distribution network are equipped with D-PMUs.When some of the D-PMUs lose time synchronization,it is still possible to locate the fault section,and at the same time,the locating results can be avoided by falling into local optimal solutions. 展开更多
关键词 Depth-first traversal fault location graph computation single-phase fault
原文传递
Design and Optimization of Dual-Winding Fault-Tolerant Permanent Magnet Motor 被引量:5
7
作者 Xuefeng Jiang Shaoshuai Wang +1 位作者 Qiang Li Yufei Gao 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期45-53,共9页
To improve the performance of the traditional fault-tolerant permanent magnet(PM)motor,the design and optimal schemes of dual-winding fault-tolerant permanent magnet motor(DWFT-PMM)are proposed and investigated.In ord... To improve the performance of the traditional fault-tolerant permanent magnet(PM)motor,the design and optimal schemes of dual-winding fault-tolerant permanent magnet motor(DWFT-PMM)are proposed and investigated.In order to obtain small cogging torque ripple and inhibiting the short-circuit current,the air gap surface shape of the PM and the anti short-circuits reactance parameters are designed and optimized.According to the actual design requirements of an aircraft electrical actuation system,the parameters,finite element analysis and experimental verification of the DWFT-PMM after optimal design are presented.The research results show that the optimized DWFT-PMM owns the merits of strong magnetic isolation,physics isolation,inhibiting the short circuit current,small cogging torque ripple and high fault tolerance. 展开更多
关键词 Dual-winding motor design and optimization fault-TOLERANCE finite element analysis short-circuit fault
下载PDF
Fault Line Selection Method Considering Grounding Fault Angle for Distribution Network 被引量:1
8
作者 Li Si-bo Zhao Yu-lin +1 位作者 Li Ji-chang Sui Tao 《Journal of Northeast Agricultural University(English Edition)》 CAS 2015年第1期58-65,共8页
In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select... In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible. 展开更多
关键词 distribution network single-phase grounding fault fault line selection fault angle wavelet transformation
下载PDF
Placement optimization of Multi-Type fault current limiters based on genetic algorithm
9
作者 Guofeng Jin Jie Tan +2 位作者 Lingling Liu Chuan Wang Tiejiang Yuan 《Global Energy Interconnection》 EI CAS CSCD 2021年第5期501-512,共12页
The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial... The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial applications.In this study,two objectives with the same dimensional measurement unit,namely,the total capital investment cost of FCLs and circuit breaker loss related to short-circuit currents,are considered.The circuit breaker loss model is developed based on the attenuation rule of the circuit breaker service life.The circuit breaker loss is used to quantify the current-limiting effect to avoid the problem of weight selection in a multi-objective problem.The IEEE 10-generator 39-bus system in New England is used to evaluate the performance of the proposed genetic algorithm(GA)method.Comparative and sensitivity analyses are performed.The results of the optimized plan are validated through simulations,indicating the significant potential of the GA for such optimization. 展开更多
关键词 fault current limiter Genetic algorithm MULTI-OBJECTIVE Circuit breaker loss short-circuit current PLACEMENT
下载PDF
New “Intellectual Networks” (Smart Grid) for Detecting Electrical Equipment Faults, Defects and Weaknesses
10
作者 Alexander Yu. Khrennikov 《Smart Grid and Renewable Energy》 2012年第3期159-164,共6页
The most important elements of “intellectual networks” (Smart Grid) are the systems of monitoring the parameters of electrical equipment. Information-measuring systems (IMS), which described in this paper, were prop... The most important elements of “intellectual networks” (Smart Grid) are the systems of monitoring the parameters of electrical equipment. Information-measuring systems (IMS), which described in this paper, were proposed to use together with rapid digital protection against short-circuit regimes in transformer windings. This paper presents an application’s experience of LVI-testing, some results of the use of Frequency Response Analysis (FRA) to check the condition of transformer windings and infra-red control results of electrical equipment. The LVI method and short-circuit inductive reactance measurements are sensitive for detecting such faults as radial, axial winding deformations, a twisting of low-voltage or regulating winding, a losing of winding’s pressing and others. 展开更多
关键词 INTELLECTUAL NETWORKS Smart Grid Monitoring SYSTEM Electrical Equipment Information-Measuring SYSTEM Frequency Response Analysis Transformer WINDING fault Diagnostic Low Voltage Impulse Method short-circuit Inductive REACTANCE Measurement
下载PDF
Intelligent System Design for Stator Windings Faults Diagnosis:Suitable for Maintenance Work
11
作者 Lane M.Rabelo Baccarini Vinícius S.Avelar +1 位作者 Valceres Vieira R.E.Silva Gleison F.V.Amaral 《Journal of Software Engineering and Applications》 2013年第10期526-532,共7页
The short circuit is a severe fault that occurs in the stator windings. Therefore, it is very important to diagnose this type of failure in its beginning before it causes unscheduled stop and the machine loss. In this... The short circuit is a severe fault that occurs in the stator windings. Therefore, it is very important to diagnose this type of failure in its beginning before it causes unscheduled stop and the machine loss. In this context, the Support Vector Machine (SVM) is a tool of considerable importance for standard classification. From some training data, it can diagnose whether or not there is a short circuit beginning, and which is important for predictive maintenance. This work proposes a technique for early detection of a short circuit between the turns aiming at its implementation in a real plant. The paper shows simulation and experimental results, and validates the proposed technique. 展开更多
关键词 fault Diagnosis Support Vector Machines Maintenance Work Software Tool Winding short-circuit
下载PDF
Validation of Full-Converter Wind Power Plant Generic Model Based on Actual Fault Ride-Through Measurements
12
作者 O. Tsernobrovkin A. Perdana +1 位作者 I. Palu J. Kilter 《Journal of Energy and Power Engineering》 2010年第4期54-62,共9页
Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full powe... Modeling and validation of full power converter wind turbine models with field measurement data are rarely reported in papers. In this paper an aggregated generic dynamic model of the wind farm consisting of full power converter wind turbines is composed and the model validation based on actual field measurements is performed. The paper is based on the measurements obtained from the real short circuit test applied to connection point of observed wind farm. The presented approach for validating the composed model and fault ride-through (FRT) capability for the whole wind park is unique in overall practice and its significance and importance is described and analyzed. 展开更多
关键词 Real short-circuit test full converter wind turbine modeling model validation generic model fault ride-through (FRT) wind power development security of supply power system stability.
下载PDF
Fault protection method of single-phase break for distribution network considering the influence of neutral grounding modes 被引量:30
13
作者 Yang Xiao Jinxin Ouyang +2 位作者 Xiaofu Xiong Yutong Wang Yongjie Luo 《Protection and Control of Modern Power Systems》 2020年第1期111-123,共13页
With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equi... With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability. 展开更多
关键词 Distribution network single-phase break fault Protection Neutral grounding
原文传递
Multiple Random Forests Based Intelligent Location of Single-phase Grounding Fault in Power Lines of DFIG-based Wind Farm 被引量:2
14
作者 Yongli Zhu Hua Peng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1152-1163,共12页
To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes a... To address the problems of wind power abandonment and the stoppage of electricity transmission caused by a short circuit in a power line of a doubly-fed induction generator(DFIG) based wind farm, this paper proposes an intelligent location method for a single-phase grounding fault based on a multiple random forests(multi-RF) algorithm. First, the simulation model is built, and the fundamental amplitudes of the zerosequence currents are extracted by a fast Fourier transform(FFT) to construct the feature set. Then, the random forest classification algorithm is applied to establish the fault section locator. The model is resampled on the basis of the bootstrap method to generate multiple sample subsets, which are used to establish multiple classification and regression tree(CART) classifiers. The CART classifiers use the mean decrease in the node impurity as the feature importance,which is used to mine the relationship between features and fault sections. Subsequently, a fault section is identified by voting on the test results for each classifier. Finally, a multi-RF regression fault locator is built to output the predicted fault distance. Experimental results with PSCAD/EMTDC software show that the proposed method can overcome the shortcomings of a single RF and has the advantage of locating a short hybrid overhead/cable line with multiple branches. Compared with support vector machines(SVMs)and previously reported methods, the proposed method can meet the location accuracy and efficiency requirements of a DFIG-based wind farm better. 展开更多
关键词 Doubly-fed induction generator(DFIG)based wind farm power line multiple random forests(multi-RF) single-phase grounding fault fault location
原文传递
Application of thyristor controlled phase shifting transformer excitation impedance switching control to suppress short-circuit fault current level 被引量:14
15
作者 Jun LIU Xudong HAO +3 位作者 Xu WANG Yefu CHEN Wanliang FANG Shuanbao NIU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第4期821-832,共12页
Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to inc... Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to increase additional equipment investments. Fast power electronics controlled flexible AC transmission system(FACTS)devices have opened a new way for suppressing the fault current levels, while maintaining their normal functionalities for steady-state and transient power system operation and control. Thyristor controlled phase shifting transformer(TCPST) is a beneficial FACTS device in modern power systems, which is capable of regulating regional powerflow. The mathematical model for TCPST under different operation modes is firstly investigated in this study. Intuitively, the phase shifting angle control can adjust the equivalent impedance of TCPST, but the effect has been demonstrated to be weak. Therefore, a novel transformer excitation impedance switching(EIS) control method, is proposed for fault current suppressing, according to the impedance characteristics of TCPST. Simulation results on IEEE 14-bus system have shown considerable current limiting characteristic of the EIS control under various fault types. Also, analysis of the timing requirement during fault interruption, overvoltage phenomenon, and ancillary mechanical support issues during EIS control is discussed,so as to implement the proposed EIS control properly for fast fault current suppression. 展开更多
关键词 Excitation impedance switching(EIS) CONTROL INTERRUPTION time sequence PHASE SHIFTING angle(PSA) CONTROL short-circuit fault current suppression Thyristorcontrolled PHASE SHIFTING transformer(TCPST)
原文传递
A New Diagnostic Method for Winding Short-Circuit Fault for SRM Based on Symmetrical Component Analysis 被引量:3
16
作者 Li Xiao Hexu Sun +2 位作者 Feng Gao Shuping Hou Lipeng Li 《Chinese Journal of Electrical Engineering》 CSCD 2018年第1期74-82,共9页
Winding short-circuit is one of the more common faults in switched reluctance motors(SRM).This paper takes an in-depth look at winding short-circuit.The characteristic of non-sinusoidal intermittent single phase curre... Winding short-circuit is one of the more common faults in switched reluctance motors(SRM).This paper takes an in-depth look at winding short-circuit.The characteristic of non-sinusoidal intermittent single phase current,fundamental components are extracted to reconstruct four phase symmetrical currents based on spectrum analysis of phase currents.The method of symmetrical component is used to calculate positive and negative sequence components of reconstructed currents,where then the ratio between positive and negative sequence component is seen as a fault feature and the diagnostic criterion is proposed.The simulation and experimental results are presented to confirm the implementation of the proposed method. 展开更多
关键词 Symmetrical component spectral analysis winding short-circuit fault switched reluctance motor
原文传递
Analysis of the harmful effects to buried oil pipeline from power line short-circuit fault 被引量:1
17
作者 LU Ying-hua MO Fan 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2012年第5期124-128,共5页
Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A ... Based on the transmission line theory of the buried metallic structures, the concerned harmful effects to the buried oil and natural gas pipelines caused by the power line short-circuit fault are further discussed. A closed-form expression of the induced voltage caused by the short-circuit fault of the ultra-high voltage power (UHVAC) transmission line is given. The transmission line model of the buried pipeline is set up and a set of formulas for calculating induced voltage on the pipeline and the parameters of the buried pipeline in actual environment condition are given. At last, the characteristic of the harm^hl effects on the buried pipeline from the power line short-circuit fault are discussed. 展开更多
关键词 ultra-high voltage (UHV) power line short-circuit fault oil pipeline transmission line model of the buried metallic structures
原文传递
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
18
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
下载PDF
Grounding Systems for Power Supply Facilities
19
作者 Vladimir Anatolevich Konusarov Evgeniy Alekseevich Shutov Tatyana Evgenievna Turukina 《Energy and Power Engineering》 2019年第1期1-14,共14页
The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition... The goal of this work is creation of optimal grounding model at the substation 10/0.4 kV of the urban power distribution network. The electric current can pose a major threat to the man’s life and health. In addition to pose a threat for health, the rise of the short circuit, as a consequence of insulation faults, poses a threat to retirement of electric systems and fire risks. The reliable grounding system design has significant implications for protection of human being as well as for electrical facility protection. The set objective was performed on the base of analytical and software-based methods. Analytical method gives a qualitative indication at each step in analysis. It also allows evaluating the values effect on the result, but the method is not susceptible of tolerable accuracy, that is why analytical method serves as initial approximation in differentiating. Specified estimation can be performed in such software package as MATLAB or ETAP. Software-based estimation is based on the finite element method (FEM), the main advantage of which is the ability to create different forms of grounding and allows obtaining distribution graphs of the step potential on the earth’s surface and touch potential. The calculation results in comparison of analytical and software-based methods taking into account the grounding optimization. There are conclusions on the most effective ground network. 展开更多
关键词 Grounding Device Current-Using Equipment short-circuit fault Single Phase-to-Ground fault Main STEP Down Substation (MSDS) TN-C TN-S TN-C-S TT IT Indirect Contact STEP Potential FEM IEEE
下载PDF
Short-circuit fault-tolerant control for five-phase fault-tolerant permanent magnet motors with trapezoidal back-EMF
20
作者 Qian Chen Yuhang Xia +2 位作者 Jiabin Wang Wenxiang Zhao Guohai Liu 《Fundamental Research》 CAS 2022年第6期964-973,共10页
When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and p... When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and phase-loss fault would generate additional torque ripples.In this study,a novel fault-tolerant control strategy is introduced to achieve low torque ripple operation of five-phase fault-tolerant permanent magnet synchronous motors with trapezoidal back electromotive force(FTPMSM-TEMF)in the event of a short-circuit fault.The key concept of this method is to compensate for the torque ripples caused by the short-circuit current and the adverse effect of the phase-loss.Based on the torque expression under fault conditions,the torque ripple caused by the short-circuit current can be offset by injecting a certain pulsating component into the torque expression in the phase-loss condition.This would result in smooth operation under fault conditions.Moreover,to track the fault-tolerant alternating currents,the model of the deadbeat current predictive control is extended and restructured for the fault condition.The effectiveness and feasibility of the proposed fault-tolerant strategy are verified by experimental results. 展开更多
关键词 short-circuit fault Five-phase fault-tolerant permanent magnet synchronous motor Trapezoidal back electromotive force fault-TOLERANT Deadbeat current predictive control
原文传递