期刊文献+
共找到172篇文章
< 1 2 9 >
每页显示 20 50 100
Investigating the occurrence and predictability of pitch angle scattering events at ADITYA-Upgrade tokamak with the electron cyclotron emission radiometer
1
作者 Varsha SIJU Santosh P.PANDYA +9 位作者 S.K.PATHAK Ansh PATEL Umesh NAGORA Shishir PUROHIT Sameer JHA M.K.GUPTA K.TAHILIANI R.KUMAR R.L.TANNA J.GHOSH 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期45-57,共13页
This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering(PAS) events through the electron cyclotron emission(ECE)radiometer signals at the ADITYA-Upg... This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering(PAS) events through the electron cyclotron emission(ECE)radiometer signals at the ADITYA-Upgrade(ADITYA-U) tokamak. For low-density discharges at ADITYA-U, a sudden abnormal rise is observed in the ECE signature while other plasma parameters are unchanged. Investigations are done to understand this abrupt rise that is expected to occur due to PAS. The rise time is as fast as 100 μs with a single step and/or multiple step rise in ECE radiometer measurements. This event is known to limit the on-axis energy of runaway electrons. Being a repetitive event, the conditions of its repetitive occurrence can be investigated, thereby exploring the possibility of it being triggered and surveyed as an alternate runaway electron mitigation plan. Functional parameterization of such events with other discharge parameters is obtained and the possibility to trigger these events is discussed.PREDICT code is used to investigate the possible interpretations for the PAS occurrence through modeling and supporting the ECE observations. The trigger values so obtained experimentally are set as input criteria for PAS occurrence. Preliminary modeling investigations provide reliable consistency with the findings. 展开更多
关键词 pitch angle scattering anomalous Doppler resonance electron cyclotron emission radiometer diagnostic runaway electrons wave-particle interaction
下载PDF
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
2
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/CT) Random coincidences scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
下载PDF
Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach 被引量:2
3
作者 Yong WANG Cong LI +2 位作者 Jielin SHI Xingwei WU Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第11期23-30,共8页
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and elec... As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×10^19m^-3 to7.1?×10^20m^-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma. 展开更多
关键词 laser Thomson scattering optical emission spectroscopy cascaded arc plasma electron density electron temperature electron excitation temperature
下载PDF
Angle Scattering Method for Soot Concentration Measurement under Ultra-Low Emissions Condition
4
作者 Bin Yang Xingchen Zhu +3 位作者 Jie Deng Xiaoxu Guo Jinke Han Xiaowei Liu 《Energy Engineering》 EI 2022年第2期511-522,共12页
Aiming at the problem of soot concentration measurement under ultra-low emission conditions,a forward small angle soot concentration measurement method is proposed.Taking a typical boiler emission of 0.1μm-3.0μm bim... Aiming at the problem of soot concentration measurement under ultra-low emission conditions,a forward small angle soot concentration measurement method is proposed.Taking a typical boiler emission of 0.1μm-3.0μm bimodal distribution soot as an object,the particle scatter simulation calculation under different parameters is carried out,and the influence of detection angle and particle size on the angular scatteringmeasurement of ultra-low emission soot is analyzed.The influence of detection angle and particle size on the angular scatteringmeasurement of ultra-lowemission soot is analyzed.Preferably,thewavelength of incident light is 650 nm,and the forward detection angle parameter is 15◦for the design of forward small angle soot concentration measurement system.An experimental system for measuring soot with standard concentration is built.Experiments of particle concentration measurement of 1.0μm and 3.0μm under ultra-low emission conditions are carried out.The results show that the average deviation of soot concentration measurement is less than 0.10 mg/m3 under the condition of ultra-low emission by using 15◦of forward detection,which provides an effective way for monitoring ultra-low emission soot concentration in coal-fired power plants. 展开更多
关键词 emission monitoring ultra-low emission soot concentration angular scattering
下载PDF
Hepatic clearance measured with ^(99m)Tc-GSA single-photon emission computed tomography to estimate liver fibrosis 被引量:12
5
作者 Masahiko Taniguchi Atsutaka Okizaki +6 位作者 Kenji Watanabe Koji Imai Koichiro Uchida Takahiro Einama Noriyuki Shuke Naoyuki Miyokawa Hiroyuki Furukawa 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16714-16720,共7页
AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPEC... AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy. 展开更多
关键词 FIBROSIS Technetium-99m-diethylenetri-aminepenta-acetic acid-galactosyl human serum albu-min single-photon emission computed tomography Hepatic clearance Liver resection
下载PDF
Impact of amplified spontaneous emission noise on the SRS threshold of high-power fiber amplifiers
6
作者 刘伟 任帅 +1 位作者 马鹏飞 周朴 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期234-238,共5页
Impact of amplified spontaneous emission(ASE)noise on the stimulated Raman scattering(SRS)threshold of highpower fiber amplifiers is demonstrated numerically through a spectral evolution approach.The simulation result... Impact of amplified spontaneous emission(ASE)noise on the stimulated Raman scattering(SRS)threshold of highpower fiber amplifiers is demonstrated numerically through a spectral evolution approach.The simulation results confirm that ASE noise in the Raman wavelength band could reduce the SRS threshold of high-power fiber amplifiers significantly.As for ASE noise originated the main amplifier,it becomes stronger and reduces the SRS threshold at shorter operation wavelength below 1052 nm.As for ASE noise originated from the seed laser,it reduces the SRS threshold at different operation wavelength under the condition that the Raman ratio is over-90 dB in the seed laser.The theoretical method and results in this work could provide a well reference to extend the operation wavelength of high-power fiber lasers. 展开更多
关键词 high-power fiber amplifiers amplified spontaneous emission stimulated Raman scattering
下载PDF
Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography 被引量:2
7
作者 Yong Huang Yangjia Lu +5 位作者 Ganlong Li Xinsheng Lai Hong Zhang Chunzhi Tang JunjunYang Gustav Wik 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第6期428-434,共7页
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th... The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint. 展开更多
关键词 acupoint specificity Waiguan (SJ 5) NEEDLING sham needling sham point single-photon emission computed tomography
下载PDF
Stimulated electromagnetic emissions spectrum observed during an X-mode heating experiment at the European Incoherent Scatter Scientific Association 被引量:2
8
作者 Xiang Wang Chen Zhou +3 位作者 Tong Xu Farideh Honary Michael Rietveld Vladimir Frolov 《Earth and Planetary Physics》 CSCD 2019年第5期391-399,共9页
An extraordinary(X-mode)electromagnetic wave,injected into the ionosphere by the ground-based heating facility at Tromsφ,Norway,was utilized to modify the ionosphere on November 6,2017.The high-power high-frequency t... An extraordinary(X-mode)electromagnetic wave,injected into the ionosphere by the ground-based heating facility at Tromsφ,Norway,was utilized to modify the ionosphere on November 6,2017.The high-power high-frequency transmitter facility located at Tromsφ belongs to the European Incoherent Scatter Scientific Association.In the experiment,stimulated electromagnetic emission(SEE)spectra were observed.A narrow continuum occurred under cold-start conditions and showed an overshoot effect lasting several seconds.Cascading peaks occurred on both sides of the heating frequency only in the preconditioned ionosphere and also showed an overshoot effect.These SEE features are probably related to the ponderomotive process in the X-mode heating experiment and are helpful for understanding the physical mechanism that generated them during the X-mode heating experiment.The features observed in the X-mode heating experiments are novel and require further investigation. 展开更多
关键词 artificial ionosphere modification stimulated electromagnetic emissions extraordinary electromagnetic wave European Incoherent scatter Scientific Association(EISCAT)
下载PDF
Single-photon scattering controlled by an imperfect cavity
9
作者 Liwei Duan Qing-Hu Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第7期234-239,共6页
We study the single-photon transport in the coupled-resonator waveguide(CRW)controlled by an imperfect cavity.A Lorentzian spectrum is introduced to describe the dissipation.We find that the probability current conser... We study the single-photon transport in the coupled-resonator waveguide(CRW)controlled by an imperfect cavity.A Lorentzian spectrum is introduced to describe the dissipation.We find that the probability current conservation can be broken,although the imperfect cavity is a Hermitian system.The coupling strength between the imperfect cavity and the CRW has significant influences near the resonant frequency.With the increase of the coupling strength,the transmission coeffi-cient becomes smaller.The spectral width plays a dominant role under the off-resonant condition,where the transmission coefficient is greatly suppressed with the increase of the spectral width.We also observe an abrupt jump of the transmission and reflection coefficients when the hopping amplitude is large enough.All the distinctive behaviors are closely related to the complex effective potential induced by the imperfect cavity. 展开更多
关键词 single-photon scattering coupled-resonator waveguide imperfect cavity
下载PDF
Single-photon scattering by two separated atoms in a supercavity
10
作者 朱伟 肖骁 +1 位作者 周端陆 张芃 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期235-241,共7页
We study the single-photon scattering along a one-dimensional cavity array with two distant two-level atoms in a supercavity,which aims to simulate a recent x-ray experiment [Nature 482,199(2012)].Without introducin... We study the single-photon scattering along a one-dimensional cavity array with two distant two-level atoms in a supercavity,which aims to simulate a recent x-ray experiment [Nature 482,199(2012)].Without introducing dissipation,we find that when one atom is exactly located at a node of a mode of the supercavity and the other is at the antinode of that mode,no splitting of the reflectivity peak can appear.Nevertheless,the atom at the node significantly changes the positions of the reflectivity valleys.On the other hand,when the atom is shifted a little from the exact node,then the splitting can appear.We also explain these results with an analysis based on the general formal scattering theory.Our result implies the importance of non-resonant modes of the supercavity in our problem. 展开更多
关键词 cavity array single-photon scattering x-ray quantum optics
下载PDF
ASSESSMENT OF MYOCARDIAL VIABILITY WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING AND COMPARISON WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
11
作者 Yi-ning Wang Zheng-yu Jin +6 位作者 Zhu-hua Zhang Ling-yan Kong Li-bo Chen Lu Zhou Hong-yi Sun Heng Zhang Qi Miao 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期239-244,共6页
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa... Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease. 展开更多
关键词 magnetic resonance imaging single-photon emission computed tomography myocardialviability
下载PDF
Single-Photon Emission from GaAs Quantum Dots Embedded in Nanowires
12
作者 杨爽 窦秀明 +4 位作者 喻颖 倪海桥 牛智川 江德生 孙宝权 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第7期198-201,共4页
A highly efficient single-photon source based on a semiconductor quantum dot (QD) is a promising candidate in quantum information processing. We report a single-photon source based on self-assembled GaAs QDs in nano... A highly efficient single-photon source based on a semiconductor quantum dot (QD) is a promising candidate in quantum information processing. We report a single-photon source based on self-assembled GaAs QDs in nanowires with an extraction efficiency of 14%. The second-order correlation function g(2) (0) at saturate excitation power is estimated to be 0.28. The measured polarization of QD emission depends on the geometric relations between the directions of PL collection and the long axis of nanowires. 展开更多
关键词 single-photon emission from GaAs Quantum Dots Embedded in Nanowires QDs
下载PDF
Indocyanine green plasma clearance rate and 99mTc-galactosyl human serum albumin single-photon emission computed tomography evaluated preoperative remnant liver
13
作者 Kentaro Iwaki Satoshi Kaihara +3 位作者 Ryosuke Kita Koji Kitamura Hiroki Hashida Kenji Uryuhara 《World Journal of Clinical Cases》 SCIE 2022年第25期8844-8853,共10页
BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the prim... BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATECTOMY Indocyanine green Indocyanine green plasma clearance rate Liver function evaluation Remnant liver reserve
下载PDF
Nonreciprocal single-photon scattering mediated by a drivenΛ-type three-level giant atom
14
作者 Xiaopei Zhang Haozhen Li +7 位作者 Ran Zeng Miao Hu Mengmeng Xu Xuefang Zhou Yang Lan Xiuwen Xia Jingping Xu Yaping Yang 《Communications in Theoretical Physics》 SCIE CAS CSCD 2024年第11期113-122,共10页
A waveguide-QED with giant atoms,which is capable of accessing various limits of a small one,provides a new paradigm to study photon scatterings.Thus,how to achieve nonreciprocal photon transmissions via such a giant ... A waveguide-QED with giant atoms,which is capable of accessing various limits of a small one,provides a new paradigm to study photon scatterings.Thus,how to achieve nonreciprocal photon transmissions via such a giant atom setup is highly desirable.In this study,the nonreciprocal single-photon scattering characteristics of a double-drivenΛ-type three-level giant atom,where one of the transition couples to a 1D waveguide at two separate points,and the other is driven by two coherent driving fields,are investigated.It is found that a frequency-tunable single-photon diode with an ideal contrast ratio can be achieved by properly manipulating the local coupling phases between the giant atom and the waveguide,the accumulation phase between the two waveguide coupling points,the Rabi frequencies and phase difference of the two driven fields.Compared to the previous single driving schemes,on the one hand,the presence of the second driving field can provide more tunable parameters to manipulate the nonreciprocal single-photon scattering behavior.On the other hand,here perfect nonreciprocal transmission for photons with arbitrary frequencies is achievable by tuning the driving phases while the two driving fields keep on turning,which provides an alternative way to control the nonreciprocal single-photon scattering.Furthermore,the results reveal that both the location and width of each optimal nonreciprocal transmission window is also sensitive to the driving detuning,and a single-photon diode with wide or narrow bandwidth can be realized based on demand.These results may be beneficial for designing nonreciprocal single-photon devices based on a double-driven giant atom setup. 展开更多
关键词 giant atom nonreciprocal single-photon scattering waveguide-QED
原文传递
Significance of functional hepatic resection rate calculated using 3D CT/^(99m)Tc-galactosyl human serum albumin singlephoton emission computed tomography fusion imaging 被引量:6
15
作者 Yosuke Tsuruga Toshiya Kamiyama +6 位作者 Hirofumi Kamachi Shingo Shimada Kenji Wakayama Tatsuya Orimo Tatsuhiko Kakisaka Hideki Yokoo Akinobu Taketomi 《World Journal of Gastroenterology》 SCIE CAS 2016年第17期4373-4379,共7页
AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission com... AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 &#x000b1; 19.9 and 44.5 &#x000b1; 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P &#x0003c; 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of &#x0003e; 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 &#x000b1; 0.19 vs 0.82 &#x000b1; 0.18, P &#x0003c; 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade &#x02265; 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of &#x0003e; 1000 mL. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATECTOMY Functional hepatic resection rate Parenchymal hepatic resection rate
下载PDF
The stimulated Raman scattering competition between solute and solvent in Rhodamine B solution
16
作者 房文汇 里佐威 +4 位作者 孙成林 李占龙 宋薇 门志伟 何丽桥 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第3期252-255,共4页
The competition between the stimulated resonance Raman scattering (SRRS) of Rhodamine B (RhB) and the stimulated Raman scattering (SRS) of ethanol (C2H50H) is observed at the RhB in C2H5OH solution. For differ... The competition between the stimulated resonance Raman scattering (SRRS) of Rhodamine B (RhB) and the stimulated Raman scattering (SRS) of ethanol (C2H50H) is observed at the RhB in C2H5OH solution. For different concentrations of the solution, the peak wavelengths of the SRRS, the amplified spontaneous emission (ASE), the fluorescence and the absorption of RhB are different. The SRRS of RhB and the SRS of C2H50H are simultaneously generated when the concentration of the solution is 10-5 mol/L and the energy of the excitation laser is 20.4 mJ. Otherwise, only either the SRRS of RhB or the SRS of C2H5OH is generated. The SRRS can be amplified by the ASE gain when the SRRS is near the peak of the ASE, and the peak wavelength of the SRRS coincides with the wavelength of the maximal intensity ASE. 展开更多
关键词 stimulated resonance Raman scattering Rhodamine B amplified spontaneous emission
下载PDF
Spatial Characteristics of Thomson Scattering in a Linearly Polarized Laser Field
17
作者 兰鹏飞 陆培祥 曹伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第2期143-146,共4页
The spatial characteristics of Thomson scattering in a linearly polarized laser field are investigated. The results show that the electron's motion and spatial distributions of Thomson scattering depend sensitively o... The spatial characteristics of Thomson scattering in a linearly polarized laser field are investigated. The results show that the electron's motion and spatial distributions of Thomson scattering depend sensitively on the phase η0 at which the electron is injected to the laser field. When η0 equals to 0 or π, the electron motion is a zigzag motion and the spatial distributions of the emission show fourfold or twofold symmetry. In other cases of phases, there is a steady drift motion of electron in the transverse direction, which results in the absence of the zigzag motion and a breakdown of the symmetry of the spatial distributions as well. 展开更多
关键词 Thomson scattering spatial distribution of the emission spatial symmetry
下载PDF
Influence of heating effect in Thomson scattering diagnosis of laser-produced plasmas in air
18
作者 Pengpeng MA Maogen SU +5 位作者 Shiquan CAO Kaiping WANG Weiwei HAN Duixiong SUN Qi MIN Chenzhong DONG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第8期144-150,共7页
A state diagnosis of laser-produced plasma in air generated by a 1064 nm pulse laser was investigated by the Thomson scattering(TS)method.The evolutions of the electron temperature and electron density were obtained a... A state diagnosis of laser-produced plasma in air generated by a 1064 nm pulse laser was investigated by the Thomson scattering(TS)method.The evolutions of the electron temperature and electron density were obtained as a function of the time delay which ranged from 300-3200 ns.The heating effect produced by the 532 nm probe beam with different energies on the air plasma at different interaction times was further studied using a time-resolved optical emission spectroscopy technique.The influence of the probe beam on the electron density was found to be negligible,whereas its influence on electron temperature is evident.In addition,the heating effect of the probe beam on the plasma strongly depends on the energy of the probe beam,and gradually weakens with increasing time delay.Our results are helpful for further understanding the TS method and its application in plasma diagnostics. 展开更多
关键词 laser-produced plasma DIAGNOSIS HEATING effect THOMSON scattering optical emission spectroscopy
下载PDF
Ultrabright γ-ray emission from the interaction of an intense laser pulse with a near-critical-density plasma
19
作者 Aynisa Tursun Mamat Ali Bake +2 位作者 Baisong Xie Yasheng Niyazi Abuduresuli Abudurexiti 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第11期419-429,共11页
An efficient scheme for generating ultrabright γ-rays from the interaction of an intense laser pulse with a near-criticaldensity plasma is studied by using the two-dimensional particle-in-cell simulation including qu... An efficient scheme for generating ultrabright γ-rays from the interaction of an intense laser pulse with a near-criticaldensity plasma is studied by using the two-dimensional particle-in-cell simulation including quantum electrodynamic effects.We investigate the effects of target shape on γ-ray generation efficiency using three configurations of the solid foils attached behind the near-critical-density plasma:a flat foil without a channel(target 1),a flat foil with a channel(target 2),and a convex foil with a channel(target 3).When an intense laser propagates in a near-critical-density plasma,a large number of electrons are trapped and accelerated to GeV energy,and emit γ-rays via nonlinear betatron oscillation in the first stage.In the second stage,the accelerated electrons collide with the laser pulse reflected from the foil and emit high-energy,high-density γ-rays via nonlinear Compton scattering.The simulation results show that compared with the other two targets,target 3 affords better focusing of the laser field and electrons,which decreases the divergence angle of g-photons.Consequently,denser and brighter γ-rays are emitted when target 3 is used.Specifically,a dense γ-ray pulse with a peak brightness of 4.6×10^(26) photons/s/mm2/mrad2/0.1%BW(at 100 MeV)and 1.8×1023 photons/s/mm2/mrad2/0.1%BW(at 2 GeV)are obtained at a laser intensity of 8.5×10^(22) W/cm2 when the plasma density is equal to the critical plasma density nc.In addition,for target 3,the effects of plasma channel length,foil curvature radius,laser polarization,and laser intensity on the γ-ray emission are discussed,and optimal values based on a series of simulations are proposed. 展开更多
关键词 electron acceleration γ-ray emission inverse Compton scattering near-critical-density plasma 2D-QED-PIC simulation
下载PDF
一种自适应的三维荧光光谱去散射方法 被引量:1
20
作者 伍卓慧 黄冰佳 +1 位作者 李学勤 王晓萍 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2024年第4期969-976,共8页
三维荧光光谱因其数据量大、灵敏度高等优点,在食品科学、分析化学、生物化学和环境科学等领域应用广泛。然而,因为同时存在瑞利散射和拉曼散射,给三维荧光光谱的定量分析和数据显示带来了困难。因此,在数据处理前期,消除散射干扰对其... 三维荧光光谱因其数据量大、灵敏度高等优点,在食品科学、分析化学、生物化学和环境科学等领域应用广泛。然而,因为同时存在瑞利散射和拉曼散射,给三维荧光光谱的定量分析和数据显示带来了困难。因此,在数据处理前期,消除散射干扰对其具有重要意义。在已有方法中,对较低浓度溶液和散射峰与物质荧光信号重叠严重光谱的去散射算法的研究相对空白。针对现有问题,提出了一种自适应的三维荧光光谱去散射方法。首先,该方法通过减去每次实验获取的溶剂的光谱基线来校正拉曼散射和背景干扰。然后综合考虑散射峰与物质峰的荧光强度和重叠程度将光谱分为五类情况对应三个重叠等级:无重叠、微弱重叠和严重重叠,分别采用置零法、分段三次Hermite插值多项式算法和高斯拟合-分段三次Hermite插值多项式耦合算法对瑞利散射进行校正处理。此方法基于一维插值,仅对单个发射光谱进行研究,降低了算法复杂度,计算时间较短。通过对酪氨酸、黄腐酸、萘乙酸和罗丹明B四种典型有机化合物进行实验,评估了该方法扣除散射干扰的有效性。并且与现阶段研究中使用最多的Delaunay三角形内插值法进行比较,以重叠区域散射校正后的数据对四种有机化合物分别进行浓度回归,此自适应方法所得的平均决定系数为0.9962,相比于Delaunay三角形内插值法提高了5.04%。同时,通过对比天然有机化合物黄腐酸分别经此方法和Delaunay三角形内插值法进行散射校正后的三维荧光光谱,进一步证明了该方法更好地保持了物质荧光光谱区域的结构特征,有效地避免了过拟合现象的发生。最后,利用该方法对模拟突发污染水样进行监测,验证了此方法具有很好的普适性,有实际应用价值,为三维荧光光谱去散射提供了一种新的思路。 展开更多
关键词 三维荧光光谱 瑞利散射 拉曼散射 自适应 去散射
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部