This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering(PAS) events through the electron cyclotron emission(ECE)radiometer signals at the ADITYA-Upg...This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering(PAS) events through the electron cyclotron emission(ECE)radiometer signals at the ADITYA-Upgrade(ADITYA-U) tokamak. For low-density discharges at ADITYA-U, a sudden abnormal rise is observed in the ECE signature while other plasma parameters are unchanged. Investigations are done to understand this abrupt rise that is expected to occur due to PAS. The rise time is as fast as 100 μs with a single step and/or multiple step rise in ECE radiometer measurements. This event is known to limit the on-axis energy of runaway electrons. Being a repetitive event, the conditions of its repetitive occurrence can be investigated, thereby exploring the possibility of it being triggered and surveyed as an alternate runaway electron mitigation plan. Functional parameterization of such events with other discharge parameters is obtained and the possibility to trigger these events is discussed.PREDICT code is used to investigate the possible interpretations for the PAS occurrence through modeling and supporting the ECE observations. The trigger values so obtained experimentally are set as input criteria for PAS occurrence. Preliminary modeling investigations provide reliable consistency with the findings.展开更多
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi...Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.展开更多
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and elec...As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×10^19m^-3 to7.1?×10^20m^-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.展开更多
Aiming at the problem of soot concentration measurement under ultra-low emission conditions,a forward small angle soot concentration measurement method is proposed.Taking a typical boiler emission of 0.1μm-3.0μm bim...Aiming at the problem of soot concentration measurement under ultra-low emission conditions,a forward small angle soot concentration measurement method is proposed.Taking a typical boiler emission of 0.1μm-3.0μm bimodal distribution soot as an object,the particle scatter simulation calculation under different parameters is carried out,and the influence of detection angle and particle size on the angular scatteringmeasurement of ultra-low emission soot is analyzed.The influence of detection angle and particle size on the angular scatteringmeasurement of ultra-lowemission soot is analyzed.Preferably,thewavelength of incident light is 650 nm,and the forward detection angle parameter is 15◦for the design of forward small angle soot concentration measurement system.An experimental system for measuring soot with standard concentration is built.Experiments of particle concentration measurement of 1.0μm and 3.0μm under ultra-low emission conditions are carried out.The results show that the average deviation of soot concentration measurement is less than 0.10 mg/m3 under the condition of ultra-low emission by using 15◦of forward detection,which provides an effective way for monitoring ultra-low emission soot concentration in coal-fired power plants.展开更多
AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPEC...AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy.展开更多
Impact of amplified spontaneous emission(ASE)noise on the stimulated Raman scattering(SRS)threshold of highpower fiber amplifiers is demonstrated numerically through a spectral evolution approach.The simulation result...Impact of amplified spontaneous emission(ASE)noise on the stimulated Raman scattering(SRS)threshold of highpower fiber amplifiers is demonstrated numerically through a spectral evolution approach.The simulation results confirm that ASE noise in the Raman wavelength band could reduce the SRS threshold of high-power fiber amplifiers significantly.As for ASE noise originated the main amplifier,it becomes stronger and reduces the SRS threshold at shorter operation wavelength below 1052 nm.As for ASE noise originated from the seed laser,it reduces the SRS threshold at different operation wavelength under the condition that the Raman ratio is over-90 dB in the seed laser.The theoretical method and results in this work could provide a well reference to extend the operation wavelength of high-power fiber lasers.展开更多
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th...The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint.展开更多
An extraordinary(X-mode)electromagnetic wave,injected into the ionosphere by the ground-based heating facility at Tromsφ,Norway,was utilized to modify the ionosphere on November 6,2017.The high-power high-frequency t...An extraordinary(X-mode)electromagnetic wave,injected into the ionosphere by the ground-based heating facility at Tromsφ,Norway,was utilized to modify the ionosphere on November 6,2017.The high-power high-frequency transmitter facility located at Tromsφ belongs to the European Incoherent Scatter Scientific Association.In the experiment,stimulated electromagnetic emission(SEE)spectra were observed.A narrow continuum occurred under cold-start conditions and showed an overshoot effect lasting several seconds.Cascading peaks occurred on both sides of the heating frequency only in the preconditioned ionosphere and also showed an overshoot effect.These SEE features are probably related to the ponderomotive process in the X-mode heating experiment and are helpful for understanding the physical mechanism that generated them during the X-mode heating experiment.The features observed in the X-mode heating experiments are novel and require further investigation.展开更多
We study the single-photon transport in the coupled-resonator waveguide(CRW)controlled by an imperfect cavity.A Lorentzian spectrum is introduced to describe the dissipation.We find that the probability current conser...We study the single-photon transport in the coupled-resonator waveguide(CRW)controlled by an imperfect cavity.A Lorentzian spectrum is introduced to describe the dissipation.We find that the probability current conservation can be broken,although the imperfect cavity is a Hermitian system.The coupling strength between the imperfect cavity and the CRW has significant influences near the resonant frequency.With the increase of the coupling strength,the transmission coeffi-cient becomes smaller.The spectral width plays a dominant role under the off-resonant condition,where the transmission coefficient is greatly suppressed with the increase of the spectral width.We also observe an abrupt jump of the transmission and reflection coefficients when the hopping amplitude is large enough.All the distinctive behaviors are closely related to the complex effective potential induced by the imperfect cavity.展开更多
We study the single-photon scattering along a one-dimensional cavity array with two distant two-level atoms in a supercavity,which aims to simulate a recent x-ray experiment [Nature 482,199(2012)].Without introducin...We study the single-photon scattering along a one-dimensional cavity array with two distant two-level atoms in a supercavity,which aims to simulate a recent x-ray experiment [Nature 482,199(2012)].Without introducing dissipation,we find that when one atom is exactly located at a node of a mode of the supercavity and the other is at the antinode of that mode,no splitting of the reflectivity peak can appear.Nevertheless,the atom at the node significantly changes the positions of the reflectivity valleys.On the other hand,when the atom is shifted a little from the exact node,then the splitting can appear.We also explain these results with an analysis based on the general formal scattering theory.Our result implies the importance of non-resonant modes of the supercavity in our problem.展开更多
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa...Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.展开更多
A highly efficient single-photon source based on a semiconductor quantum dot (QD) is a promising candidate in quantum information processing. We report a single-photon source based on self-assembled GaAs QDs in nano...A highly efficient single-photon source based on a semiconductor quantum dot (QD) is a promising candidate in quantum information processing. We report a single-photon source based on self-assembled GaAs QDs in nanowires with an extraction efficiency of 14%. The second-order correlation function g(2) (0) at saturate excitation power is estimated to be 0.28. The measured polarization of QD emission depends on the geometric relations between the directions of PL collection and the long axis of nanowires.展开更多
BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the prim...BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment.展开更多
A waveguide-QED with giant atoms,which is capable of accessing various limits of a small one,provides a new paradigm to study photon scatterings.Thus,how to achieve nonreciprocal photon transmissions via such a giant ...A waveguide-QED with giant atoms,which is capable of accessing various limits of a small one,provides a new paradigm to study photon scatterings.Thus,how to achieve nonreciprocal photon transmissions via such a giant atom setup is highly desirable.In this study,the nonreciprocal single-photon scattering characteristics of a double-drivenΛ-type three-level giant atom,where one of the transition couples to a 1D waveguide at two separate points,and the other is driven by two coherent driving fields,are investigated.It is found that a frequency-tunable single-photon diode with an ideal contrast ratio can be achieved by properly manipulating the local coupling phases between the giant atom and the waveguide,the accumulation phase between the two waveguide coupling points,the Rabi frequencies and phase difference of the two driven fields.Compared to the previous single driving schemes,on the one hand,the presence of the second driving field can provide more tunable parameters to manipulate the nonreciprocal single-photon scattering behavior.On the other hand,here perfect nonreciprocal transmission for photons with arbitrary frequencies is achievable by tuning the driving phases while the two driving fields keep on turning,which provides an alternative way to control the nonreciprocal single-photon scattering.Furthermore,the results reveal that both the location and width of each optimal nonreciprocal transmission window is also sensitive to the driving detuning,and a single-photon diode with wide or narrow bandwidth can be realized based on demand.These results may be beneficial for designing nonreciprocal single-photon devices based on a double-driven giant atom setup.展开更多
AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission com...AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of > 1000 mL.展开更多
The competition between the stimulated resonance Raman scattering (SRRS) of Rhodamine B (RhB) and the stimulated Raman scattering (SRS) of ethanol (C2H50H) is observed at the RhB in C2H5OH solution. For differ...The competition between the stimulated resonance Raman scattering (SRRS) of Rhodamine B (RhB) and the stimulated Raman scattering (SRS) of ethanol (C2H50H) is observed at the RhB in C2H5OH solution. For different concentrations of the solution, the peak wavelengths of the SRRS, the amplified spontaneous emission (ASE), the fluorescence and the absorption of RhB are different. The SRRS of RhB and the SRS of C2H50H are simultaneously generated when the concentration of the solution is 10-5 mol/L and the energy of the excitation laser is 20.4 mJ. Otherwise, only either the SRRS of RhB or the SRS of C2H5OH is generated. The SRRS can be amplified by the ASE gain when the SRRS is near the peak of the ASE, and the peak wavelength of the SRRS coincides with the wavelength of the maximal intensity ASE.展开更多
The spatial characteristics of Thomson scattering in a linearly polarized laser field are investigated. The results show that the electron's motion and spatial distributions of Thomson scattering depend sensitively o...The spatial characteristics of Thomson scattering in a linearly polarized laser field are investigated. The results show that the electron's motion and spatial distributions of Thomson scattering depend sensitively on the phase η0 at which the electron is injected to the laser field. When η0 equals to 0 or π, the electron motion is a zigzag motion and the spatial distributions of the emission show fourfold or twofold symmetry. In other cases of phases, there is a steady drift motion of electron in the transverse direction, which results in the absence of the zigzag motion and a breakdown of the symmetry of the spatial distributions as well.展开更多
A state diagnosis of laser-produced plasma in air generated by a 1064 nm pulse laser was investigated by the Thomson scattering(TS)method.The evolutions of the electron temperature and electron density were obtained a...A state diagnosis of laser-produced plasma in air generated by a 1064 nm pulse laser was investigated by the Thomson scattering(TS)method.The evolutions of the electron temperature and electron density were obtained as a function of the time delay which ranged from 300-3200 ns.The heating effect produced by the 532 nm probe beam with different energies on the air plasma at different interaction times was further studied using a time-resolved optical emission spectroscopy technique.The influence of the probe beam on the electron density was found to be negligible,whereas its influence on electron temperature is evident.In addition,the heating effect of the probe beam on the plasma strongly depends on the energy of the probe beam,and gradually weakens with increasing time delay.Our results are helpful for further understanding the TS method and its application in plasma diagnostics.展开更多
An efficient scheme for generating ultrabright γ-rays from the interaction of an intense laser pulse with a near-criticaldensity plasma is studied by using the two-dimensional particle-in-cell simulation including qu...An efficient scheme for generating ultrabright γ-rays from the interaction of an intense laser pulse with a near-criticaldensity plasma is studied by using the two-dimensional particle-in-cell simulation including quantum electrodynamic effects.We investigate the effects of target shape on γ-ray generation efficiency using three configurations of the solid foils attached behind the near-critical-density plasma:a flat foil without a channel(target 1),a flat foil with a channel(target 2),and a convex foil with a channel(target 3).When an intense laser propagates in a near-critical-density plasma,a large number of electrons are trapped and accelerated to GeV energy,and emit γ-rays via nonlinear betatron oscillation in the first stage.In the second stage,the accelerated electrons collide with the laser pulse reflected from the foil and emit high-energy,high-density γ-rays via nonlinear Compton scattering.The simulation results show that compared with the other two targets,target 3 affords better focusing of the laser field and electrons,which decreases the divergence angle of g-photons.Consequently,denser and brighter γ-rays are emitted when target 3 is used.Specifically,a dense γ-ray pulse with a peak brightness of 4.6×10^(26) photons/s/mm2/mrad2/0.1%BW(at 100 MeV)and 1.8×1023 photons/s/mm2/mrad2/0.1%BW(at 2 GeV)are obtained at a laser intensity of 8.5×10^(22) W/cm2 when the plasma density is equal to the critical plasma density nc.In addition,for target 3,the effects of plasma channel length,foil curvature radius,laser polarization,and laser intensity on the γ-ray emission are discussed,and optimal values based on a series of simulations are proposed.展开更多
文摘This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering(PAS) events through the electron cyclotron emission(ECE)radiometer signals at the ADITYA-Upgrade(ADITYA-U) tokamak. For low-density discharges at ADITYA-U, a sudden abnormal rise is observed in the ECE signature while other plasma parameters are unchanged. Investigations are done to understand this abrupt rise that is expected to occur due to PAS. The rise time is as fast as 100 μs with a single step and/or multiple step rise in ECE radiometer measurements. This event is known to limit the on-axis energy of runaway electrons. Being a repetitive event, the conditions of its repetitive occurrence can be investigated, thereby exploring the possibility of it being triggered and surveyed as an alternate runaway electron mitigation plan. Functional parameterization of such events with other discharge parameters is obtained and the possibility to trigger these events is discussed.PREDICT code is used to investigate the possible interpretations for the PAS occurrence through modeling and supporting the ECE observations. The trigger values so obtained experimentally are set as input criteria for PAS occurrence. Preliminary modeling investigations provide reliable consistency with the findings.
基金supported by the Tehran University of Medical Sciences under Grant No.36291PET/CT and Cyclotron Center of Masih Daneshvari Hospital at Shahid Beheshti University of Medical Sciences。
文摘Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.
基金supported by the National Magnetic Confinement Fusion Science Program of China(No.2013GB109005)the Fundamental Research Funds for the Central Universities(Nos.DUT15RC(3)072,DUT15TD44,DUT16TD13)
文摘As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×10^19m^-3 to7.1?×10^20m^-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.
基金This research was supported by National Key Research and Development Program of China(2016YFB0600601)National Natural Science Foundation of China(51806144).
文摘Aiming at the problem of soot concentration measurement under ultra-low emission conditions,a forward small angle soot concentration measurement method is proposed.Taking a typical boiler emission of 0.1μm-3.0μm bimodal distribution soot as an object,the particle scatter simulation calculation under different parameters is carried out,and the influence of detection angle and particle size on the angular scatteringmeasurement of ultra-low emission soot is analyzed.The influence of detection angle and particle size on the angular scatteringmeasurement of ultra-lowemission soot is analyzed.Preferably,thewavelength of incident light is 650 nm,and the forward detection angle parameter is 15◦for the design of forward small angle soot concentration measurement system.An experimental system for measuring soot with standard concentration is built.Experiments of particle concentration measurement of 1.0μm and 3.0μm under ultra-low emission conditions are carried out.The results show that the average deviation of soot concentration measurement is less than 0.10 mg/m3 under the condition of ultra-low emission by using 15◦of forward detection,which provides an effective way for monitoring ultra-low emission soot concentration in coal-fired power plants.
文摘AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy.
基金the National Natural Science Foundation of China(Grant Nos.62005313 and 62061136013).
文摘Impact of amplified spontaneous emission(ASE)noise on the stimulated Raman scattering(SRS)threshold of highpower fiber amplifiers is demonstrated numerically through a spectral evolution approach.The simulation results confirm that ASE noise in the Raman wavelength band could reduce the SRS threshold of high-power fiber amplifiers significantly.As for ASE noise originated the main amplifier,it becomes stronger and reduces the SRS threshold at shorter operation wavelength below 1052 nm.As for ASE noise originated from the seed laser,it reduces the SRS threshold at different operation wavelength under the condition that the Raman ratio is over-90 dB in the seed laser.The theoretical method and results in this work could provide a well reference to extend the operation wavelength of high-power fiber lasers.
基金supported by the National 973 Program of China,No.2006CB504505the National Natural Science Foundation of China,No.90709027
文摘The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint.
基金supported by the National Natural Science Foundation of China(grant numbers 41204111,41574146,41774162,and 41704155)the China Postdoctoral Science Foundation(grant numbers 2017M622504 and2019T120679)supported through the Russian Education Ministry(project number3.1844.2017)
文摘An extraordinary(X-mode)electromagnetic wave,injected into the ionosphere by the ground-based heating facility at Tromsφ,Norway,was utilized to modify the ionosphere on November 6,2017.The high-power high-frequency transmitter facility located at Tromsφ belongs to the European Incoherent Scatter Scientific Association.In the experiment,stimulated electromagnetic emission(SEE)spectra were observed.A narrow continuum occurred under cold-start conditions and showed an overshoot effect lasting several seconds.Cascading peaks occurred on both sides of the heating frequency only in the preconditioned ionosphere and also showed an overshoot effect.These SEE features are probably related to the ponderomotive process in the X-mode heating experiment and are helpful for understanding the physical mechanism that generated them during the X-mode heating experiment.The features observed in the X-mode heating experiments are novel and require further investigation.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11834005 and 11674285)。
文摘We study the single-photon transport in the coupled-resonator waveguide(CRW)controlled by an imperfect cavity.A Lorentzian spectrum is introduced to describe the dissipation.We find that the probability current conservation can be broken,although the imperfect cavity is a Hermitian system.The coupling strength between the imperfect cavity and the CRW has significant influences near the resonant frequency.With the increase of the coupling strength,the transmission coeffi-cient becomes smaller.The spectral width plays a dominant role under the off-resonant condition,where the transmission coefficient is greatly suppressed with the increase of the spectral width.We also observe an abrupt jump of the transmission and reflection coefficients when the hopping amplitude is large enough.All the distinctive behaviors are closely related to the complex effective potential induced by the imperfect cavity.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11222430,11434011,11475254,and 11175247)the National Key Basic Research Program of China(Grant Nos.2012CB922104 and 2014CB921202)
文摘We study the single-photon scattering along a one-dimensional cavity array with two distant two-level atoms in a supercavity,which aims to simulate a recent x-ray experiment [Nature 482,199(2012)].Without introducing dissipation,we find that when one atom is exactly located at a node of a mode of the supercavity and the other is at the antinode of that mode,no splitting of the reflectivity peak can appear.Nevertheless,the atom at the node significantly changes the positions of the reflectivity valleys.On the other hand,when the atom is shifted a little from the exact node,then the splitting can appear.We also explain these results with an analysis based on the general formal scattering theory.Our result implies the importance of non-resonant modes of the supercavity in our problem.
文摘Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.
基金Supported by the National Key Basic Research Program of China under Grant No 2013CB922304the National Natural Science Foundation of China under Grant Nos 11474275 and 11204297
文摘A highly efficient single-photon source based on a semiconductor quantum dot (QD) is a promising candidate in quantum information processing. We report a single-photon source based on self-assembled GaAs QDs in nanowires with an extraction efficiency of 14%. The second-order correlation function g(2) (0) at saturate excitation power is estimated to be 0.28. The measured polarization of QD emission depends on the geometric relations between the directions of PL collection and the long axis of nanowires.
文摘BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment.
基金supported by the China Postdoctoral Science Foundation (Grant No.2023M732028)the Zhejiang Province Key Laboratory of Quantum Technology and Device (Grant No.20230201)+2 种基金the Zhejiang Provincial Natural Science Foundation of China (Grant No.LY21A040003)the National Key Research and Development Program of China (Grant No.2021YFA1400602)the National Natural Science Foundation of China (Grant Nos.11864018,12164022,12174288 and 12274326)。
文摘A waveguide-QED with giant atoms,which is capable of accessing various limits of a small one,provides a new paradigm to study photon scatterings.Thus,how to achieve nonreciprocal photon transmissions via such a giant atom setup is highly desirable.In this study,the nonreciprocal single-photon scattering characteristics of a double-drivenΛ-type three-level giant atom,where one of the transition couples to a 1D waveguide at two separate points,and the other is driven by two coherent driving fields,are investigated.It is found that a frequency-tunable single-photon diode with an ideal contrast ratio can be achieved by properly manipulating the local coupling phases between the giant atom and the waveguide,the accumulation phase between the two waveguide coupling points,the Rabi frequencies and phase difference of the two driven fields.Compared to the previous single driving schemes,on the one hand,the presence of the second driving field can provide more tunable parameters to manipulate the nonreciprocal single-photon scattering behavior.On the other hand,here perfect nonreciprocal transmission for photons with arbitrary frequencies is achievable by tuning the driving phases while the two driving fields keep on turning,which provides an alternative way to control the nonreciprocal single-photon scattering.Furthermore,the results reveal that both the location and width of each optimal nonreciprocal transmission window is also sensitive to the driving detuning,and a single-photon diode with wide or narrow bandwidth can be realized based on demand.These results may be beneficial for designing nonreciprocal single-photon devices based on a double-driven giant atom setup.
文摘AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of > 1000 mL.
基金Project supported by the National Natural Science Foundation of China (Gant No. 10974067)the Young Scientists Fund of the National Natural Science Foundation of China (Grant No. 11104106)+1 种基金the Science and Technology Planning Project of Jilin Province, China (Gant Nos. 20101508 201101037 and 201115033)China Postdoctoral Science Foundation (Grant No. 20100481062)
文摘The competition between the stimulated resonance Raman scattering (SRRS) of Rhodamine B (RhB) and the stimulated Raman scattering (SRS) of ethanol (C2H50H) is observed at the RhB in C2H5OH solution. For different concentrations of the solution, the peak wavelengths of the SRRS, the amplified spontaneous emission (ASE), the fluorescence and the absorption of RhB are different. The SRRS of RhB and the SRS of C2H50H are simultaneously generated when the concentration of the solution is 10-5 mol/L and the energy of the excitation laser is 20.4 mJ. Otherwise, only either the SRRS of RhB or the SRS of C2H5OH is generated. The SRRS can be amplified by the ASE gain when the SRRS is near the peak of the ASE, and the peak wavelength of the SRRS coincides with the wavelength of the maximal intensity ASE.
基金the National Natural Science Foundation of China(No.10574050)the Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20040487023)
文摘The spatial characteristics of Thomson scattering in a linearly polarized laser field are investigated. The results show that the electron's motion and spatial distributions of Thomson scattering depend sensitively on the phase η0 at which the electron is injected to the laser field. When η0 equals to 0 or π, the electron motion is a zigzag motion and the spatial distributions of the emission show fourfold or twofold symmetry. In other cases of phases, there is a steady drift motion of electron in the transverse direction, which results in the absence of the zigzag motion and a breakdown of the symmetry of the spatial distributions as well.
基金This work is supported by the National Key Research and Development Program of China(No.2017YFA0402300)National Natural Science Foundation of China(Nos.11874051,11564037,61741513,11904293)the Special Fund Project for Guiding Scientific and Technological Inno-vation of Gansu Province(No.2019zx-10).
文摘A state diagnosis of laser-produced plasma in air generated by a 1064 nm pulse laser was investigated by the Thomson scattering(TS)method.The evolutions of the electron temperature and electron density were obtained as a function of the time delay which ranged from 300-3200 ns.The heating effect produced by the 532 nm probe beam with different energies on the air plasma at different interaction times was further studied using a time-resolved optical emission spectroscopy technique.The influence of the probe beam on the electron density was found to be negligible,whereas its influence on electron temperature is evident.In addition,the heating effect of the probe beam on the plasma strongly depends on the energy of the probe beam,and gradually weakens with increasing time delay.Our results are helpful for further understanding the TS method and its application in plasma diagnostics.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11664039,11875007,and 11664040).
文摘An efficient scheme for generating ultrabright γ-rays from the interaction of an intense laser pulse with a near-criticaldensity plasma is studied by using the two-dimensional particle-in-cell simulation including quantum electrodynamic effects.We investigate the effects of target shape on γ-ray generation efficiency using three configurations of the solid foils attached behind the near-critical-density plasma:a flat foil without a channel(target 1),a flat foil with a channel(target 2),and a convex foil with a channel(target 3).When an intense laser propagates in a near-critical-density plasma,a large number of electrons are trapped and accelerated to GeV energy,and emit γ-rays via nonlinear betatron oscillation in the first stage.In the second stage,the accelerated electrons collide with the laser pulse reflected from the foil and emit high-energy,high-density γ-rays via nonlinear Compton scattering.The simulation results show that compared with the other two targets,target 3 affords better focusing of the laser field and electrons,which decreases the divergence angle of g-photons.Consequently,denser and brighter γ-rays are emitted when target 3 is used.Specifically,a dense γ-ray pulse with a peak brightness of 4.6×10^(26) photons/s/mm2/mrad2/0.1%BW(at 100 MeV)and 1.8×1023 photons/s/mm2/mrad2/0.1%BW(at 2 GeV)are obtained at a laser intensity of 8.5×10^(22) W/cm2 when the plasma density is equal to the critical plasma density nc.In addition,for target 3,the effects of plasma channel length,foil curvature radius,laser polarization,and laser intensity on the γ-ray emission are discussed,and optimal values based on a series of simulations are proposed.