期刊文献+
共找到408篇文章
< 1 2 21 >
每页显示 20 50 100
Characteristics of the SOL ion-to-electron temperature ratio on the J-TEXT tokamak with different plasma configurations
1
作者 李存凯 梁云峰 +16 位作者 江中和 周松 华建坤 阳杰 杨庆虎 Alexander KNIEPS Philipp DREWS 徐鑫 毛飞越 谢伟 杨雨桐 郭金龙 李杨波 任正康 陈志鹏 王能超 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期13-21,共9页
Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and d... Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and divertor plasma transport in magnetically confined fusion research.On the J-TEXT tokamak,a multi-channel retarding field analyzer(RFA) probe has been developed to study average plasma parameters in the edge region under various poloidal divertor and island divertor configurations.The edge radial profile of the ion-to-electron temperature ratio,τ_(i/e),has been determined,which gradually decreases as the SOL ion self-collisionality,v_(SOL)*,increases.This is broadly consistent with what has been observed previously from various tokamak experiments.However,the comparison of experimental results under different configurations shows that in the poloidal divertor configuration,even under the same v_(SOL)*,τ_(i/e) in the SOL region becomes smaller as the distance from the X-point to the target plate increases.In the island divertor configuration,τ_(i/e) near the O-point is higher than that near the X-point at the same v_(SOL)*,and both are higher than those in the limiter configuration.These results suggest that the magnetic configuration plays a critical role in the energy distributions between electrons and ions at the plasma boundary. 展开更多
关键词 ion temperature island divertor poloidal divertor retarding field analyzer(RFA)probe
下载PDF
Plasma potential measurements using an emissive probe made of oxide cathode
2
作者 李建泉 马海杰 陆文琪 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期571-577,共7页
A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparis... A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparison with a traditional tungsten emissive probe,including the operating temperature,the electron emission capability and the plasma potential measurement.Studies of the operating temperature and electron emission capability show that the tungsten emissive probe usually works at a temperature of 1800 K-2200 K while the oxide cathode emissive probe can function at about 1200 K-1400 K.In addition,plasma potential measurements using the oxide cathode emissive probe with different techniques have been accomplished in microwave electron cyclotron resonance plasmas with different discharge powers.It is found that a reliable plasma potential can be obtained using the improved inflection point method and the hot probe with zero emission limit method,while the floating point method is invalid for the oxide cathode emissive probe. 展开更多
关键词 emissive probe oxide cathode plasma potential filament temperature
下载PDF
Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics
3
作者 Sunil KANCHI Rohit SHUKLA Archana SHARMA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期94-100,共7页
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In... Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources. 展开更多
关键词 coaxial plasma source triple Langmuir probe Faraday cup plasma density plasma temperature
下载PDF
Frequency dependence of electron temperature in hollow cathode-type discharge as measured by several different floating probe methods
4
作者 Shuichi SATO Hiromu KAWANA +1 位作者 Tatsushi FUJIMINE Mikio OHUCHI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第8期50-57,共8页
We measured electron temperatures through a hollow cathode-type discharge tube using several different floating probe methods. This method detected a shift in the floating potential when an AC voltage was applied to a... We measured electron temperatures through a hollow cathode-type discharge tube using several different floating probe methods. This method detected a shift in the floating potential when an AC voltage was applied to a probe through an intermediary blocking capacitor. The shift in the floating potential is described as a function of the electron temperature and the applied AC voltage. In this study, the effects of the frequency and waveform on the electron temperatures were systematically investigated. The electron temperature measured when using the floating probe method with applied sinusoidal and triangular voltages was lower than that measured with an applied rectangular voltage.The value in the high frequency range was close to that of the tail electron temperature. 展开更多
关键词 electrostatic probe Langmuir probe floating potential electron temperature SHEATH
下载PDF
Electron Temperature Measurement by Floating Probe Method Using AC Voltage
5
作者 Satoshi NODOMI Shuichi SATO Mikio OHUCHI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第11期1089-1094,共6页
This study presents a novel floating probe method to measure electron temperatures using a hollow cathode-type discharge tube. The proposed method detects a shift in the floating potential when an AC voltage is applie... This study presents a novel floating probe method to measure electron temperatures using a hollow cathode-type discharge tube. The proposed method detects a shift in the floating potential when an AC voltage is applied to a probe through an intermediary blocking capacitor. The shift in the floating potential is described as a function of the electron temperature and the applied AC voltage. The floating probe method is simpler than the Langmuir probe method because it does not require the measurement of volt-ampere characteristics. As the input AC voltage increases, the electron temperature converges. The electron temperature measured using the floating probe method with an applied sinusoidal voltage shows a value close to the first (tail) electron temperature in the range of the floating potential. 展开更多
关键词 electrostatic probe Langmuir probe floating potential electron temperature SHEATH
下载PDF
High-precision nuclear magnetic resonance probe suitable for in situ studies of high-temperature metallic melts
6
作者 Ao Li Wei Xu +4 位作者 Xiao Chen Bing-Nan Yao Jun-Tao Huo Jun-Qiang Wang Run-Wei Li 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第4期48-55,共8页
High-temperature nuclear magnetic resonance(NMR)has proven to be very useful for detecting the temperatureinduced structural evolution and dynamics in melts.However,the sensitivity and precision of high-temperature NM... High-temperature nuclear magnetic resonance(NMR)has proven to be very useful for detecting the temperatureinduced structural evolution and dynamics in melts.However,the sensitivity and precision of high-temperature NMR probes are limited.Here we report a sensitive and stable high-temperature NMR probe based on laser-heating,suitable for in situ studies of metallic melts,which can work stably at the temperature of up to 2000 K.In our design,a well-designed optical path and the use of a water-cooled copper radio-frequency(RF)coil significantly optimize the signal-to-noise ratio(S/NR)at high temperatures.Additionally,a precise temperature controlling system with an error of less than±1 K has been designed.After temperature calibration,the temperature measurement error is controlled within±2 K.As a performance testing,^(27)Al NMR spectra are measured in Zr-based metallic glass-forming liquid in situ.Results show that the S/NR reaches 45 within 90 s even when the sample's temperature is up to 1500 K and that the isothermal signal drift is better than0.001 ppm per hour.This high-temperature NMR probe can be used to clarify some highly debated issues about metallic liquids,such as glass transition and liquid-liquid transition. 展开更多
关键词 high-temperature NMR probe laser beams temperature measurement metallic melts
下载PDF
New Measuring Temperature Setup with Optical Probe
7
作者 HOU Peiguo, LIU Jianming(Yanshan University, Qinbuangdao 066004, CHN ) 《Semiconductor Photonics and Technology》 CAS 1997年第1期71-73,共3页
Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power s... Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power signal in a long distance, the fiber technology is applied in this setup. 展开更多
关键词 Micro - power Consumptive probe Optical Fiber Transmission Sen-sors temperature Measurement
下载PDF
Influence of Temperature Probes Installation on the Salient Pole to Temperature Measurement
8
作者 Z. Hanic M. Kovacic M. Vrazic 《Journal of Energy and Power Engineering》 2011年第8期776-784,共9页
Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram.... Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface. 展开更多
关键词 temperature measurement AC generators rotating machine measurements excitation winding thermal probes digital measurements measurement accuracy measurement errors.
下载PDF
Effect of Temperature on Gas Hold-up in Aerated Stirred Tanks 被引量:7
9
作者 高正明 施力田 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2003年第2期204-207,共4页
Gas holdups in ambient gassed and hot sparged systems with multiple modern impellers and the effect of temperature on gas holdup are reported. The operating temperature has a great impact on gas holdup though the gas ... Gas holdups in ambient gassed and hot sparged systems with multiple modern impellers and the effect of temperature on gas holdup are reported. The operating temperature has a great impact on gas holdup though the gas dispersion regime in the hot sparged system is similar to the ambient gassed condition. The gas holdup under the elevated temperature and the ambient gassed operation is successfully correlated. With the same total gas flow rate and power input, the gas holdup in the hot sparged system (say near the boiling point) is only about half of that in the ambient system. The results imply that almost all existing hot sparged reactors have been designed on the basis of incorrect estimates of the gas holdup during operation. 展开更多
关键词 gas holdup temperature effect gas dispersion hot sparged reactors radar probe stirred tank
下载PDF
GROUND TEMPERATURE AND ROCK THERMOPHYSICAL PROPERTIES IN FILDES PENINSULA 被引量:1
10
作者 Yang Shuzhen Zhang Wenren Shen Xianjie Institute of Geology, Academia Sinica, Beijing 100029 《Chinese Journal of Polar Science》 1990年第1期58-66,共9页
During 1985-1986, 1986-1987, and 1988-1989 expeditions on Fildes Peninsula the ground temperature was measured. A total number of 218 ground temperature data were obtained. The thermal conductivity measurements were m... During 1985-1986, 1986-1987, and 1988-1989 expeditions on Fildes Peninsula the ground temperature was measured. A total number of 218 ground temperature data were obtained. The thermal conductivity measurements were made on 121 rock samples collected during expedition. This article gives a brief analysis and summarization of these data. 展开更多
关键词 Ground temperature Fildes Peninsula temperature probe Rock thermal conductivity Hydrothermal process.
下载PDF
Temperature measurement based on radialization power for micro-hotplate 被引量:1
11
作者 张彤 漆奇 +3 位作者 刘奎学 刘丽 张蕾 徐宝琨 《中国有色金属学会会刊:英文版》 CSCD 2006年第B02期780-784,共5页
A novel method to measure the temperature on the surface of micro-hotplate was presented. The tiny fiber probe and the optical power meter were employed to measure the sample radialization power. By means of comparing... A novel method to measure the temperature on the surface of micro-hotplate was presented. The tiny fiber probe and the optical power meter were employed to measure the sample radialization power. By means of comparing the relationship between the radialization power and the temperature, sample surface temperature can be discerned accurately. Such an approach has provided more accuracy than traditional temperature measurements. The experimental result based on this method is quite similar to that of simulation by the finite element analysis (FEA) software of Ansys in theory. This measurement is very useful for measuring temperature for these micro samples prone to be untouchable. 展开更多
关键词 气体传感器 微型热盘 辐射功率 温度测量 热分布
下载PDF
Symmetric Temperature Compensation for Photoelectric Coupling Current Transducer
12
作者 SHANGHong-yan Zhong-Jia-qing 《Semiconductor Photonics and Technology》 CAS 2001年第4期230-234,共5页
The temperature characteristic of sensor probe at high voltage side is analyzed by using a photoelectric coupling current transducer. The principle of symmetric temperature compensation and the main idea of software d... The temperature characteristic of sensor probe at high voltage side is analyzed by using a photoelectric coupling current transducer. The principle of symmetric temperature compensation and the main idea of software design are proposed. The method increases measuring precision and has fairly great practicability. 展开更多
关键词 Current transducer Sensor probe temperature compensation
下载PDF
基于多个热成像探头传感器的滑环装置碳刷温度监测与分析
13
作者 胡庆雄 罗金文 +2 位作者 刘绍勇 张昆 刘举 《电力系统装备》 2024年第2期114-116,共3页
文章设计了一款基于多个热成像探头传感器的滑环装置碳刷温度监测系统,该系统利用热成像探头传感器来获取碳刷的温度数据,并通过数据处理和分析,实现对碳刷温度的监测和报警。系统采用热成像视频监测,增加现地显示装置,通过对系统进行设... 文章设计了一款基于多个热成像探头传感器的滑环装置碳刷温度监测系统,该系统利用热成像探头传感器来获取碳刷的温度数据,并通过数据处理和分析,实现对碳刷温度的监测和报警。系统采用热成像视频监测,增加现地显示装置,通过对系统进行设计,实现了历史数据查询、故障预警等多种功能,可更好地保障水利发电的安全运行。 展开更多
关键词 热成像探头 传感器 滑环装置 碳刷温度 监测系统
下载PDF
环境敏感型碳点响应机制及其在生物传感领域的应用
14
作者 霍泽鹏 徐蔚青 徐抒平 《分析测试学报》 CAS CSCD 北大核心 2024年第1期147-156,共10页
碳点因具有优异的光学可调特性、良好的生物相容性,在生物医学、能源催化等领域展现出巨大的应用潜力。环境敏感型碳点是一类可响应周围介质环境改变而实现自身特性改变的材料,在传感方面倍受关注。该文对近来环境敏感型碳点的响应机制... 碳点因具有优异的光学可调特性、良好的生物相容性,在生物医学、能源催化等领域展现出巨大的应用潜力。环境敏感型碳点是一类可响应周围介质环境改变而实现自身特性改变的材料,在传感方面倍受关注。该文对近来环境敏感型碳点的响应机制进行梳理,具体包括pH、极性、粘度、温度四个方面,并综述了该材料在生物传感领域的应用进展,以期为开发和设计更多可应用的环境敏感型碳点提供参考。 展开更多
关键词 碳点 环境敏感探针 极性 PH 粘度 温度
下载PDF
一种等离子体溯源测量装置设计及性能测试
15
作者 李耀 贾军伟 +7 位作者 王青青 武宇婧 常猛 董学江 郝剑昆 郎昊 李绍飞 张韧 《航天器环境工程》 CSCD 2024年第2期181-189,共9页
文章设计了一套等离子体溯源测量装置为验证感应耦合等离子体(ICP)源作为校准源的性能,找出满足朗缪尔探针溯源校准的最佳等离子体测试条件,提升测试准确性,采用控制变量法对不同工况下ICP源等离子体电子密度和电子温度的稳定性和均匀性... 文章设计了一套等离子体溯源测量装置为验证感应耦合等离子体(ICP)源作为校准源的性能,找出满足朗缪尔探针溯源校准的最佳等离子体测试条件,提升测试准确性,采用控制变量法对不同工况下ICP源等离子体电子密度和电子温度的稳定性和均匀性,以及电子密度的重复性进行测试。结果表明:在放电开始5~20 min内,等离子体电子密度和电子温度的稳定性分别优于99.4%和98.9%;在探针伸入真空腔体内440~480 mm的范围内,等离子体电子密度和电子温度的均匀性分别优于97.2%和93.6%;在等离子体源放电功率100~900 W范围时,等离子体电子密度的重复性优于86.6%,并且多数在92%以上。本研究可为后续等离子体诊断手段的优化提供参考。 展开更多
关键词 等离子体源 朗缪尔探针 控制变量法 结构设计 电子密度 电子温度
下载PDF
基于自淬灭探针的LAMP可视化快速检测方法
16
作者 熊雄 薛晗玥 +2 位作者 费延堻 王诗慧 谢普军 《食品研究与开发》 CAS 2024年第9期166-173,共8页
该研究拟筛选与自淬灭探针互补的寡核苷酸序列,利用双链DNA的荧光超淬灭机制,构建可视化反应体系,从而实现基于自淬灭探针的环介导等温扩增(loop-mediated isothermal amplification,LAMP)可视化快速检测。结果表明:添加与自淬灭探针完... 该研究拟筛选与自淬灭探针互补的寡核苷酸序列,利用双链DNA的荧光超淬灭机制,构建可视化反应体系,从而实现基于自淬灭探针的环介导等温扩增(loop-mediated isothermal amplification,LAMP)可视化快速检测。结果表明:添加与自淬灭探针完全互补的寡核苷酸序列,体系的背景荧光强度会出现显著下降(P<0.05)。当熔解温度(melting temperature,Tm)值高于室温时,缩短互补序列的长度(从3'端)不会影响其淬灭作用。基于互补序列的荧光超淬灭机制构建的LAMP可视化反应体系能够有效降低背景荧光,反应结束后表现出易于读取的可视化结果,并成功用于虹鳟鱼的快速检测。综上,合适的互补序列能够降低自淬灭探针的背景荧光,利用该互补序列和自淬灭探针建立低背景荧光的LAMP体系能够在可视化检测中表现出适用性。 展开更多
关键词 自淬灭探针 荧光淬灭 互补序列 Tm值 可视化
下载PDF
加热光纤法同步测定土壤水热参数误差分析
17
作者 胡优 司炳成 +4 位作者 李敏 何海龙 何冬 任姮烨 刘吕刚 《土壤学报》 CAS CSCD 北大核心 2024年第4期989-997,共9页
土壤水热参数是研究土壤水热传输的基本物理参数。当前热脉冲探针法(HPP)可同步测定土壤水热参数,但该方法仅限于在点尺度下测定。与其具有相同理论基础的加热光纤法(SPHP-DTS),可将测定尺度增大至田间千米尺度,但其测定精度尚未得到有... 土壤水热参数是研究土壤水热传输的基本物理参数。当前热脉冲探针法(HPP)可同步测定土壤水热参数,但该方法仅限于在点尺度下测定。与其具有相同理论基础的加热光纤法(SPHP-DTS),可将测定尺度增大至田间千米尺度,但其测定精度尚未得到有效验证。为了探知SPHP-DTS法的误差,本研究进行了SPHP-DTS法与HPP法测定土壤水热参数的对比试验。结果表明,以HPP为标准,加热光纤法测定热导率的精度RMSE为0.13 W×m^(-1)×℃^(-1)。SPHP-DTS法测定的热导率显著高于HPP法,主要原因在于加热光纤时产生的温度效应。通过热导率法测定土壤含水率时,在热导率测定误差的影响下,SPHP-DTS法的测定精度明显低于HPP法。SPHP-DTS法测定土壤水热参数的其他误差来源包括光纤与土壤之间多个界面的接触热阻、光纤的温度敏感性、噪音干扰以及温度梯度驱动下的水分迁移。本研究可为SPHP-DTS法提升土壤水热参数测定精度提供理论参考。 展开更多
关键词 土壤热导率 土壤含水率 加热光纤法 热脉冲探针 分布式温度传感技术
下载PDF
自动检测设备高温下测试坐标修正方法
18
作者 左宁 袁丽娟 +1 位作者 胡奇威 霍鑫 《电子工艺技术》 2024年第1期51-55,共5页
硅晶圆半导体芯片在进行晶圆级电性能测量时,往往需要模拟芯片实际工作时的工作环境,如温度、湿度、气压。在自动探针台上进行高温环境模拟测试时,由于高温会导致测针、晶圆片和承片卡盘产生一定程度的形变,从而使得芯片上测试Pad位置... 硅晶圆半导体芯片在进行晶圆级电性能测量时,往往需要模拟芯片实际工作时的工作环境,如温度、湿度、气压。在自动探针台上进行高温环境模拟测试时,由于高温会导致测针、晶圆片和承片卡盘产生一定程度的形变,从而使得芯片上测试Pad位置坐标发生偏移,这种情况下,测试系统需要对形变后的测试点坐标进行修正。提出了一种基于机器视觉自动图形识别的在线修正测试点坐标偏移方法,用以解决自动探针台在高温环境下进行电性能测试时的测试坐标修正难题。 展开更多
关键词 探针测试系统 坐标修正 高温形变
下载PDF
The Langmuir Probe onboard CSES: data inversion analysis method and first results 被引量:7
19
作者 Rui Yan YiBing Guan +4 位作者 XuHui Shen JianPing Huang XueMin Zhang Chao Liu DaPeng Liu 《Earth and Planetary Physics》 2018年第6期479-488,共10页
The Langmuir Probe(LAP), onboard the China Seismo-Electromagnetic Satellite(CSES), has been designed for in situ measurements of bulk parameters of the ionosphere plasma, the first Chinese application of in-situ measu... The Langmuir Probe(LAP), onboard the China Seismo-Electromagnetic Satellite(CSES), has been designed for in situ measurements of bulk parameters of the ionosphere plasma, the first Chinese application of in-situ measurement technology in the field of space exploration. The two main parameters measured by LAP are electron density and temperature. In this paper, a brief description of the LAP and its work mode are provided. Based on characteristics of the LAP, and assuming an ideal plasma environment, we introduce in detail a method used to invert the I-V curve; the data products that can be accessed by users are shown. Based on the LAP data available, this paper reports that events such as earthquakes and magnetic storms are preceded and followed by obvious abnormal changes. We suggest that LAP could provide a valuable data set for studies of space weather, seismic events, and the ionospheric environment. 展开更多
关键词 Langmuir probe(LAP) Current-Voltage(I-V) curve electron density(Ne) electron temperature(Te)
下载PDF
Sweep Langmuir Probe and Triple Probe Diagnostics for Transient Plasma Produced by Hypervelocity Impact 被引量:1
20
作者 唐恩凌 相升海 +1 位作者 杨明海 李乐新 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第8期747-753,共7页
Two techniques are applied to diagnose characteristic parameters of plasma created by hypervelocity impact, such as electron temperature and electron density. The first technique is a sweep Langmuir probe (SLP), whi... Two techniques are applied to diagnose characteristic parameters of plasma created by hypervelocity impact, such as electron temperature and electron density. The first technique is a sweep Langmuir probe (SLP), which is a new apparatus based on a dual channel circuit that can compensate for stray capacitance and obtain a good synchronicity, so that electrostatic turbulence with a good temporal resolution can be acquired. The second technique is a triple Langmuir probe (TLP), which is an electrostatic triple Langmuir probe diagnostic system, in which no voltage and frequency sweep is required. This technique allows to measure electron temperature, electron density as a function of time. Moreover, the triple Langmuir probe diagnostic system allows the direct display of electron temperature and semidirect display of electron density by an appropriate display system, the system permits us to eliminate almost all data processing procedures. SLP and TLP were applied to obtain fluctuations of the characteristic parameters of plasma generated by hypervelocity impact. As an example of their application to time-dependent plasma measure- ment, the electron temperature and electron density of plasmas were acquired in hypervelocity impact experiments. Characteristic parameters of plasma generated by hypervelocity impact were compared by the two kinds of diagnostic techniques mentioned above. 展开更多
关键词 hypervelocity impact PLASMA sweep Langmuir probe (SLP) triple Langmuirprobe (TLP) electron temperature electron density
下载PDF
上一页 1 2 21 下一页 到第
使用帮助 返回顶部