This paper proposes a single-stage inverter system with maximum power point tracking control (MPPT) applicable in low-power photovoltaic (PV) energy conversion systems. The proposed system is successfully implemented ...This paper proposes a single-stage inverter system with maximum power point tracking control (MPPT) applicable in low-power photovoltaic (PV) energy conversion systems. The proposed system is successfully implemented using a single digital signal processor (DSP) TMS320F2808. The proposed single-stage inverter system has the following features: 1) the ability to harvest the maximum PV power using two simple and effective current sampling methods;2) flexible topology based on the positioning of DC link capacitor on the outside of the inverter bridge circuits;3) reduced volume and higher efficiency than the conventional two-stage inverters, and 4) MPPT accuracy of 99.3% with overall efficiency of 90% under the full-load condition.展开更多
In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,whe...In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,where high performance,efficiency,and reliability are crucial.The ability of the drive system to maintain long-term fault-tolerant control(FTC)operation after a failure is essential.The likelihood of inverter failures surpasses that of other components in the drive system,highlighting its critical importance.Long-term FTC operation ensures the system retains its fundamental functions until safe repairs or replacements can be made.The focus of developing a FTC strategy has shifted from basic FTC operations to enhancing the post-fault quality to accommodate the realities of prolonged operation post-failure.This paper primarily investigates FTC strategies for inverter failures in various motor drive systems over the past decade.These strategies are categorized into three types based on post-fault operational quality:rescue,remedy,and reestablishment.The paper discusses each typical control strategy and its research focus,the strengths and weaknesses of various algorithms,and recent advancements in FTC.Finally,this review summarizes effective FTC techniques for inverter failures in motor drive systems and suggests directions for future research.展开更多
For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging ...For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging speed and power density.However,this trend poses significant challenges for high-voltage and high-frequency motor controllers,which are plagued by increased switching losses and pronounced switching oscillations as consequences of hard switching.The deployment of soft switching technology presents a viable solution to mitigate these issues.This paper reviews the applications of soft switching technologies for three-phase inverters and classifies them based on distinct characteristics.For each type of inverter,the advantages and disadvantages are evaluated.Then,the paper introduces the research progress and control methods of soft switching inverters (SSIs).Moreover,it presents a comparative analysis among the conventional hard switching inverters (HSIs),an active clamping resonant DC link inverter (ACRDCLI) and an auxiliary resonant commuted pole inverter (ARCPI).Finally,the problems and prospects of soft switching technology applied to motor controllers for EVs are put forward.展开更多
The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backsteppin...The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backstepping technology and dynamic surface control is formulated for the inverter in the grid-connected photovoltaic.The time-varying tuning functions are introduced into state-tracking errors to realize the predefined-time control effect.To address the“computational explosion problem”in the design process of backstepping control,dynamic surface control is adopted to avoid the analytical calculations of virtual control.The disturbances of the PV system are estimated and compensated by adaptive laws.The control parameters are chosen and the global stability of the closed-loop is ensured by Lyapunov conditions.Simulation results confirm the effectiveness of the proposed controller and ensure the predefined time control in the photovoltaic inverter.展开更多
This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elim...This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations.展开更多
The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone ...The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone or connected to a network.The energy produced by the photovoltaic generator is in continuous form;the conversion from its continuous form to the alternating form requires a converter:the inverter.In order to improve the quality of the waveform,we moved from the classic solar inverter to multilevel inverters.These multilevel inverters are equipped with power switches which are required to withstand strong fluctuations in the voltage produced by the GPV(photovoltaic generator).It is obvious that the degradation of the inverter leads to a distortion of the wave quality.This article presents the simulation of the GPV-Chopper Boost-Inverter chain in fault-tolerant cascaded H-bridges in order to overcome the difficulties of voltage constraints experienced by power switches(IGBT:insulated gate bipolar transistor).The results of simulations carried out in Matlab/Simulink show good performance of the designed inverter model.展开更多
During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in unc...During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in uncertainties in the calculation of the short-circuit current at the time of a fault.Additionally,the impacts of such uncertainties around short-circuit currents will increase with the increase of distributed power sources.Thus,it is very important to develop a method for calculating the short-circuit current while considering the uncertainties in a distribution network.In this study,an affine arithmetic algorithm for calculating short-circuit current intervals in distribution networks with distributed power sources while considering power fluctuations is presented.The proposed algorithm includes two stages.In the first stage,normal operations are considered to establish a conservative interval affine optimization model of injection currents in distributed power sources.Constrained by the fluctuation range of distributed generation power at the moment of fault occurrence,the model can then be used to solve for the fluctuation range of injected current amplitudes in distributed power sources.The second stage is implemented after a malfunction occurs.In this stage,an affine optimization model is first established.This model is developed to characterizes the short-circuit current interval of a transmission line,and is constrained by the fluctuation range of the injected current amplitude of DG during normal operations.Finally,the range of the short-circuit current amplitudes of distribution network lines after a short-circuit fault occurs is predicted.The algorithm proposed in this article obtains an interval range containing accurate results through interval operation.Compared with traditional point value calculation methods,interval calculation methods can provide more reliable analysis and calculation results.The range of short-circuit current amplitude obtained by this algorithm is slightly larger than those obtained using the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Therefore,the proposed algorithm has good suitability and does not require iterative calculations,resulting in a significant improvement in computational speed compared to the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Furthermore,the proposed algorithm can provide more reliable analysis and calculation results,improving the safety and stability of power systems.展开更多
A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)...A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)inverter devices are subjected to vapor condensation,a risk could occur.Given the amount of moisture in the air,saturation occurswhen the temperature drops to the dewpoint,and condensationmay formon surfaces.Numerical simulation with“COMSOL Software”is important for obtaining knowledge relevant to preventing condensation by using two steps.At first,the assumption was that the device’s water vapor concentration was homogeneous to evaluate the amount of liquid water accumulated on the internal walls of the photovoltaic(PV)inverter box.Second,by considering the effect of external wind velocity onmoisture transport at the air interface to evaluate water vapor transport outdoors and reduce condensation.General factorial designs are utilized for analyzing the nature of the relationship between the vapor condensation response and the variables.Reducing vapor condensation inside the solar inverter by the effect of external wind speed on diffusion as a process of transporting moister air outside the inverter box is the main solution for this problem.During the movement and assessment of the flow of water vapor,the impact of vapor condensation is reduced.The saturation period was determined by using a Boolean saturation indicator.The saturation indicator was set to 1 when saturation was detected(relative humidity greater than or equal to 1)and 0 otherwise.Calculating the flow and dispersion of moist air as a function of wind speed helped solve the problem.展开更多
The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation...The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation systems and proposes an approach based on the efficiency formula widely documented in the literature. In the absence of input data, this method makes it possible to estimate the plant’s input power using data extracted from the site, in particular that provided by the Ministry of the Environment. The importance of this study lies in the need to accurately determine the input power in order to assess the overall performance of the energy system.展开更多
Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors wi...Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dcdc stage in each submodule(SM), while a hybrid modulation strategy(HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCs. Finally, both simulation and experimental results verify the effectiveness of the presented method.展开更多
Aiming at the problem of low accuracy of traditional target detection methods for target detection in endoscopes in substation environments, a CNN-based real-time detection method for masked targets is proposed. The m...Aiming at the problem of low accuracy of traditional target detection methods for target detection in endoscopes in substation environments, a CNN-based real-time detection method for masked targets is proposed. The method adopts the overall design of backbone network, detection network and algorithmic parameter optimisation method, completes the model training on the self-constructed occlusion target dataset, and adopts the multi-scale perception method for target detection. The HNM algorithm is used to screen positive and negative samples during the training process, and the NMS algorithm is used to post-process the prediction results during the detection process to improve the detection efficiency. After experimental validation, the obtained model has the multi-class average predicted value (mAP) of the dataset. It has general advantages over traditional target detection methods. The detection time of a single target on FDDB dataset is 39 ms, which can meet the need of real-time target detection. In addition, the project team has successfully deployed the method into substations and put it into use in many places in Beijing, which is important for achieving the anomaly of occlusion target detection.展开更多
We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc...We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules.展开更多
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple...A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters.展开更多
The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inve...The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...展开更多
The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs wavefo...The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs waveform inverter can achieve the output voltage regulated in a wide range of input voltage as well as the perfect output waveform. A 1 500 V input 80 kVA inverter has been deve loped. Experiments of the 80kVA inverter resulted in that the scheme is a perfect method for the development of high power converters with high efficiency.展开更多
DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the pa...DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance.展开更多
A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft swi...A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test.展开更多
A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse c...A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.展开更多
文摘This paper proposes a single-stage inverter system with maximum power point tracking control (MPPT) applicable in low-power photovoltaic (PV) energy conversion systems. The proposed system is successfully implemented using a single digital signal processor (DSP) TMS320F2808. The proposed single-stage inverter system has the following features: 1) the ability to harvest the maximum PV power using two simple and effective current sampling methods;2) flexible topology based on the positioning of DC link capacitor on the outside of the inverter bridge circuits;3) reduced volume and higher efficiency than the conventional two-stage inverters, and 4) MPPT accuracy of 99.3% with overall efficiency of 90% under the full-load condition.
基金supported in part by the National Natural Science Foundation of China under Grants 52025073 and 52107047in part by China Scholarship Council。
文摘In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,where high performance,efficiency,and reliability are crucial.The ability of the drive system to maintain long-term fault-tolerant control(FTC)operation after a failure is essential.The likelihood of inverter failures surpasses that of other components in the drive system,highlighting its critical importance.Long-term FTC operation ensures the system retains its fundamental functions until safe repairs or replacements can be made.The focus of developing a FTC strategy has shifted from basic FTC operations to enhancing the post-fault quality to accommodate the realities of prolonged operation post-failure.This paper primarily investigates FTC strategies for inverter failures in various motor drive systems over the past decade.These strategies are categorized into three types based on post-fault operational quality:rescue,remedy,and reestablishment.The paper discusses each typical control strategy and its research focus,the strengths and weaknesses of various algorithms,and recent advancements in FTC.Finally,this review summarizes effective FTC techniques for inverter failures in motor drive systems and suggests directions for future research.
基金funded by Tsinghua University-Weichai Power Intelligent Manufacturing Joint Research Institute (WCDL-GH-2022-0131)。
文摘For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging speed and power density.However,this trend poses significant challenges for high-voltage and high-frequency motor controllers,which are plagued by increased switching losses and pronounced switching oscillations as consequences of hard switching.The deployment of soft switching technology presents a viable solution to mitigate these issues.This paper reviews the applications of soft switching technologies for three-phase inverters and classifies them based on distinct characteristics.For each type of inverter,the advantages and disadvantages are evaluated.Then,the paper introduces the research progress and control methods of soft switching inverters (SSIs).Moreover,it presents a comparative analysis among the conventional hard switching inverters (HSIs),an active clamping resonant DC link inverter (ACRDCLI) and an auxiliary resonant commuted pole inverter (ARCPI).Finally,the problems and prospects of soft switching technology applied to motor controllers for EVs are put forward.
基金supported by the State Grid Corporation of China Headquarters Science and Technology Project under Grant No.5400-202122573A-0-5-SF。
文摘The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backstepping technology and dynamic surface control is formulated for the inverter in the grid-connected photovoltaic.The time-varying tuning functions are introduced into state-tracking errors to realize the predefined-time control effect.To address the“computational explosion problem”in the design process of backstepping control,dynamic surface control is adopted to avoid the analytical calculations of virtual control.The disturbances of the PV system are estimated and compensated by adaptive laws.The control parameters are chosen and the global stability of the closed-loop is ensured by Lyapunov conditions.Simulation results confirm the effectiveness of the proposed controller and ensure the predefined time control in the photovoltaic inverter.
基金the Natural Science Foundation of Fujian,China(No.2021J01633).
文摘This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations.
文摘The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone or connected to a network.The energy produced by the photovoltaic generator is in continuous form;the conversion from its continuous form to the alternating form requires a converter:the inverter.In order to improve the quality of the waveform,we moved from the classic solar inverter to multilevel inverters.These multilevel inverters are equipped with power switches which are required to withstand strong fluctuations in the voltage produced by the GPV(photovoltaic generator).It is obvious that the degradation of the inverter leads to a distortion of the wave quality.This article presents the simulation of the GPV-Chopper Boost-Inverter chain in fault-tolerant cascaded H-bridges in order to overcome the difficulties of voltage constraints experienced by power switches(IGBT:insulated gate bipolar transistor).The results of simulations carried out in Matlab/Simulink show good performance of the designed inverter model.
基金This article was supported by the general project“Research on Wind and Photovoltaic Fault Characteristics and Practical Short Circuit Calculation Model”(521820200097)of Jiangxi Electric Power Company.
文摘During faults in a distribution network,the output power of a distributed generation(DG)may be uncertain.Moreover,the output currents of distributed power sources are also affected by the output power,resulting in uncertainties in the calculation of the short-circuit current at the time of a fault.Additionally,the impacts of such uncertainties around short-circuit currents will increase with the increase of distributed power sources.Thus,it is very important to develop a method for calculating the short-circuit current while considering the uncertainties in a distribution network.In this study,an affine arithmetic algorithm for calculating short-circuit current intervals in distribution networks with distributed power sources while considering power fluctuations is presented.The proposed algorithm includes two stages.In the first stage,normal operations are considered to establish a conservative interval affine optimization model of injection currents in distributed power sources.Constrained by the fluctuation range of distributed generation power at the moment of fault occurrence,the model can then be used to solve for the fluctuation range of injected current amplitudes in distributed power sources.The second stage is implemented after a malfunction occurs.In this stage,an affine optimization model is first established.This model is developed to characterizes the short-circuit current interval of a transmission line,and is constrained by the fluctuation range of the injected current amplitude of DG during normal operations.Finally,the range of the short-circuit current amplitudes of distribution network lines after a short-circuit fault occurs is predicted.The algorithm proposed in this article obtains an interval range containing accurate results through interval operation.Compared with traditional point value calculation methods,interval calculation methods can provide more reliable analysis and calculation results.The range of short-circuit current amplitude obtained by this algorithm is slightly larger than those obtained using the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Therefore,the proposed algorithm has good suitability and does not require iterative calculations,resulting in a significant improvement in computational speed compared to the Monte Carlo algorithm and the Latin hypercube sampling algorithm.Furthermore,the proposed algorithm can provide more reliable analysis and calculation results,improving the safety and stability of power systems.
基金This research received funding from Project Number 13040115Code(NRC/VPRA/FSEIRPC/F05).
文摘A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)inverter devices are subjected to vapor condensation,a risk could occur.Given the amount of moisture in the air,saturation occurswhen the temperature drops to the dewpoint,and condensationmay formon surfaces.Numerical simulation with“COMSOL Software”is important for obtaining knowledge relevant to preventing condensation by using two steps.At first,the assumption was that the device’s water vapor concentration was homogeneous to evaluate the amount of liquid water accumulated on the internal walls of the photovoltaic(PV)inverter box.Second,by considering the effect of external wind velocity onmoisture transport at the air interface to evaluate water vapor transport outdoors and reduce condensation.General factorial designs are utilized for analyzing the nature of the relationship between the vapor condensation response and the variables.Reducing vapor condensation inside the solar inverter by the effect of external wind speed on diffusion as a process of transporting moister air outside the inverter box is the main solution for this problem.During the movement and assessment of the flow of water vapor,the impact of vapor condensation is reduced.The saturation period was determined by using a Boolean saturation indicator.The saturation indicator was set to 1 when saturation was detected(relative humidity greater than or equal to 1)and 0 otherwise.Calculating the flow and dispersion of moist air as a function of wind speed helped solve the problem.
文摘The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation systems and proposes an approach based on the efficiency formula widely documented in the literature. In the absence of input data, this method makes it possible to estimate the plant’s input power using data extracted from the site, in particular that provided by the Ministry of the Environment. The importance of this study lies in the need to accurately determine the input power in order to assess the overall performance of the energy system.
基金supported in part by the CAS Project for Young Scientists in Basic Research under Grant No. YSBR-045the Youth Innovation Promotion Association CAS under Grant 2022137the Institute of Electrical Engineering CAS under Grant E155320101。
文摘Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dcdc stage in each submodule(SM), while a hybrid modulation strategy(HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCs. Finally, both simulation and experimental results verify the effectiveness of the presented method.
文摘Aiming at the problem of low accuracy of traditional target detection methods for target detection in endoscopes in substation environments, a CNN-based real-time detection method for masked targets is proposed. The method adopts the overall design of backbone network, detection network and algorithmic parameter optimisation method, completes the model training on the self-constructed occlusion target dataset, and adopts the multi-scale perception method for target detection. The HNM algorithm is used to screen positive and negative samples during the training process, and the NMS algorithm is used to post-process the prediction results during the detection process to improve the detection efficiency. After experimental validation, the obtained model has the multi-class average predicted value (mAP) of the dataset. It has general advantages over traditional target detection methods. The detection time of a single target on FDDB dataset is 39 ms, which can meet the need of real-time target detection. In addition, the project team has successfully deployed the method into substations and put it into use in many places in Beijing, which is important for achieving the anomaly of occlusion target detection.
基金Research on Control Methods and Fault Tolerance of Multilevel Electronic Transformers for PV Access(Project number:042300034204)Research on Open-Circuit Fault Diagnosis and Seamless Fault-Tolerant Control of Multiple Devices in Modular Multilevel Digital Power Amplifiers(Project number:202203021212210)Research on Key Technologies and Demonstrations of Low-Voltage DC Power Electronic Converters Based on SiC Devices Access(Project number:202102060301012)。
文摘We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules.
文摘A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters.
文摘The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...
文摘The pulse width modulation (PWM) scheme is used in the staircase waveform inverters. The control strategy and system characteristics are analyzed. While the single pulse width modulation is used, the 12 stairs waveform inverter can achieve the output voltage regulated in a wide range of input voltage as well as the perfect output waveform. A 1 500 V input 80 kVA inverter has been deve loped. Experiments of the 80kVA inverter resulted in that the scheme is a perfect method for the development of high power converters with high efficiency.
文摘DC component is contained in inverter output voltage due to many reasons such as the zero-point deviation of operational amplifiers and the differences between power switching transistors′ characteristics. For the parallel inverter system without output isolation transformers, the difference of DC components of the output voltage can cause large DC loop-current among modular inverters. Aiming at this problem, this paper studies several DC loop-current detecting and restraining methods. By digital adjustment with high precision on the DC components of reference sine wave, the DC components of inverter′s output voltage can be adjusted to restrain DC loop-current. Experimental results prove that the DC loop-current detecting and restraining methods have a good performance.
文摘A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test.
文摘A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.