Direct slicing from GAD models to generate sectional contours of the part to be sintered for Selective Laser Sintering (SLS) may overcome inherent disadvantages of using a Stereo Lithography (STL) format. In this ...Direct slicing from GAD models to generate sectional contours of the part to be sintered for Selective Laser Sintering (SLS) may overcome inherent disadvantages of using a Stereo Lithography (STL) format. In this paper, a direct slicing procedure is proposed for Selective Laser Sintering based on material performance and process parameters. Slicing thickness depends on the 3 D geometric model, material performance and process parameters. The relationship among material performance, process parameters and the largest slicing thickness is established using analysis of a sintering temperature field. A dynamic linked library is developed to realize direct slicing from a CAD model.展开更多
Background Multislice helical computed tomography (MSCT) has been used to depict coronary anatomy noninvasively, and proved useful for evaluating ventricular function. The aim of our study was to assess the accuracy...Background Multislice helical computed tomography (MSCT) has been used to depict coronary anatomy noninvasively, and proved useful for evaluating ventricular function. The aim of our study was to assess the accuracy of ventricular volume as measured by MSCT.Methods Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned by MSCT. A series of LV and RV short-axis images were reconstructed later with slice thickness of 2.0 mm, 3.5 mm, 5.0 mm, 7.0 mm, and 10.0 mm. Ventricular volume was calculated by the multislice tomographic Simpson’s method. True LV and RV cast volumes were determined by water displacement. Results Both calculated LV and RV volumes correlated highly with the corresponding true volumes (all r>0.95, P<0.01). But with slice thickness from 2.0 mm to 10.0 mm, MSCT scanning overestimated the corresponding true volume by (3.21±5.95) ml to (12.58±8.56) ml for LV and (10.22±8.45) ml to (23.91±12.24) ml for RV (all P<0.01). There was a very high correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.01, respectively). However, when slice thickness was reduced to 5.0 mm, the overestimation for both LV and RV volume measurements became nonsignificant for slice thickness from 2.0 mm to 5.0 mm. Conclusions Both LV and RV volumes can be accurately estimated by MSCT. Thinner slice has more accurate calculated volume. However, 5.0 mm slice thickness is thin enough for an accurate measurement of LV or RV volume.展开更多
文摘Direct slicing from GAD models to generate sectional contours of the part to be sintered for Selective Laser Sintering (SLS) may overcome inherent disadvantages of using a Stereo Lithography (STL) format. In this paper, a direct slicing procedure is proposed for Selective Laser Sintering based on material performance and process parameters. Slicing thickness depends on the 3 D geometric model, material performance and process parameters. The relationship among material performance, process parameters and the largest slicing thickness is established using analysis of a sintering temperature field. A dynamic linked library is developed to realize direct slicing from a CAD model.
基金This study was supported in partbyagrant from the Doctor Foundation of ScienceandTechnologyBureauofHebeiProvince (No .0 0 5 42 0 0D -15 ) .
文摘Background Multislice helical computed tomography (MSCT) has been used to depict coronary anatomy noninvasively, and proved useful for evaluating ventricular function. The aim of our study was to assess the accuracy of ventricular volume as measured by MSCT.Methods Fourteen human left ventricular (LV) and 15 right ventricular (RV) casts were scanned by MSCT. A series of LV and RV short-axis images were reconstructed later with slice thickness of 2.0 mm, 3.5 mm, 5.0 mm, 7.0 mm, and 10.0 mm. Ventricular volume was calculated by the multislice tomographic Simpson’s method. True LV and RV cast volumes were determined by water displacement. Results Both calculated LV and RV volumes correlated highly with the corresponding true volumes (all r>0.95, P<0.01). But with slice thickness from 2.0 mm to 10.0 mm, MSCT scanning overestimated the corresponding true volume by (3.21±5.95) ml to (12.58±8.56) ml for LV and (10.22±8.45) ml to (23.91±12.24) ml for RV (all P<0.01). There was a very high correlation between the overestimation and the selected slice thickness for both LV and RV volume measurements (r=0.998 and 0.996, P<0.01, respectively). However, when slice thickness was reduced to 5.0 mm, the overestimation for both LV and RV volume measurements became nonsignificant for slice thickness from 2.0 mm to 5.0 mm. Conclusions Both LV and RV volumes can be accurately estimated by MSCT. Thinner slice has more accurate calculated volume. However, 5.0 mm slice thickness is thin enough for an accurate measurement of LV or RV volume.