期刊文献+
共找到746篇文章
< 1 2 38 >
每页显示 20 50 100
Post-fire cyclic behavior of reinforced concrete shear walls 被引量:5
1
作者 刘桂荣 宋玉普 曲福来 《Journal of Central South University》 SCIE EI CAS 2010年第5期1103-1108,共6页
The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyc... The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone. 展开更多
关键词 钢筋混凝土剪力墙 循环试验 火灾后 低周反复荷载试验 行为 轴向载荷 初始刚度 抗震性能
下载PDF
Nonlinear Finite Element Analysis of Mechanical Performance of Reinforced Concrete Short-Limb Shear Wall 被引量:1
2
作者 XUELi-min 《Wuhan University Journal of Natural Sciences》 EI CAS 2005年第3期562-565,共4页
On the basis of test, nonlinear finite element analysis of reinforcedconcrete (R. C) short-limb shear walls under monotonic horizontal load are carried out by ANSYSprogram in order to understand the evolution of crack... On the basis of test, nonlinear finite element analysis of reinforcedconcrete (R. C) short-limb shear walls under monotonic horizontal load are carried out by ANSYSprogram in order to understand the evolution of cracking, deformation and failure course of thespecimens. At the same time, the results of numerical calculation are compared with the results oftest. The results indicate that, under monotonic horizontal load the failures of the specimens withflange wall and without flange wall all occur at the intersections of lintel bottom and limb ofwall, the failures also occur at the bottom of limb; the load-displacement curve of wall withoutflange is steeper than that of wall with flange, and the ductility is worse than that of wall withflange; the results, such as cracking, deformation, yield load and so on of finite element analysisagree well with the results of test. These results provide theoretical basis of study andapplication of R. C short-limb shear wall. 展开更多
关键词 reinforced concrete short-limb shear wall mechanical performance finiteelement method NONLINEAR
下载PDF
Experimental studies on behavior of fully grouted reinforced-concrete masonry shear walls 被引量:3
3
作者 Zhao Yan Wang Fenglai 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第4期743-757,共15页
An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the... An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the influence of different reinforcements and applied axial stress values on their seismic behavior. The results show that flexural strength increases with the applied axial stress, and shear strength dominated by diagonal cracking increases with both the amount of horizontal reinforcement and applied axial stress. Yield displacement, ductility, and energy dissipation capability can be improved substantially by increasing the amount of horizontal reinforcement. The critical parameters for the walls are derived from the experiment: displacement ductility values corresponding to 15% strength degradation of the walls reach up to 2.6 and 4.5 in the shear and flexure failure modes, respectively; stiffness values of flexure- and shear-dominated walls rapidly degrade to 17%–19% and 48%–57% of initial stiffness at 0.50 D<sub>max</sub> (displacement at peak load). The experiment suggests that RMSWs could be assigned a higher damping ratio (~14%) for collapse prevention design and a lower damping value (~7%) for a fully operational limit state or serviceability limit state. 展开更多
关键词 reinforced-concrete masonry shear wall shear strength DUCTILITY stiffness degradation energy dissipation equivalent viscous damping ratio
下载PDF
Performance index limits of high reinforced concrete shear wall components 被引量:1
4
作者 劳晓春 韩小雷 《Journal of Central South University》 SCIE EI CAS 2011年第4期1248-1255,共8页
The deformation performance index limits of high reinforced concrete(RC) shear wall components based on Chinese codes were discussed by the nonlinear finite element method.Two typical RC shear wall specimens in the pr... The deformation performance index limits of high reinforced concrete(RC) shear wall components based on Chinese codes were discussed by the nonlinear finite element method.Two typical RC shear wall specimens in the previous work were first used to verify the correctness of the nonlinear finite element method.Then,the nonlinear finite element method was applied to study the deformability of a set of high RC shear wall components designed according to current Chinese codes and with shear span ratio λ≥2.0.Parametric studies were made on the influence of shear span ratio,axial compression ratio,ratio of flexural capacity to shear capacity and main flexural reinforcement ratio of confined boundary members.Finally,the deformation performance index and its limits of high RC shear wall components under severe earthquakes were proposed by the finite element model results,which offers a reference in determining the performance status of RC shear wall components designed based on Chinese codes. 展开更多
关键词 钢筋混凝土剪力墙 代码组件 性能指标 非线性有限元方法 RC剪力墙 抗弯能力 有限元模型 性能指数
下载PDF
Analysis on Construction Quality Control Technology of Reinforced Concrete Shear Wall Structure
5
作者 Ting Zhou 《Frontiers Research of Architecture and Engineering》 2018年第4期117-121,共5页
In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa... In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises. 展开更多
关键词 reinforced concrete shear wall structure Construction QUALITY Control technology
下载PDF
Experimental and analytical study on seismic behavior of steel-concrete multienergy dissipation composite shear walls 被引量:4
6
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Qiao Qiyun Yu Chuanpeng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期125-139,共15页
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p... In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique. 展开更多
关键词 steel reinforced concrete steel plate deep beam multi energy dissipation composite shear wall seismic behavior
下载PDF
Effect of Eccentric Shear Stiffness of Walls on Structural Response of RC Frame Buildings
7
作者 Muhammad Umair Saleem 《Open Journal of Civil Engineering》 2017年第4期527-538,共12页
Current research study consists of determining the optimum location of the shear wall to get the maximum structural efficiency of a reinforced concrete frame building. It consists of a detailed analysis and design rev... Current research study consists of determining the optimum location of the shear wall to get the maximum structural efficiency of a reinforced concrete frame building. It consists of a detailed analysis and design review of a seven-story reinforced concrete building to understand the effect of shear wall location on the response of reinforced concrete structures when subjected to different earthquake forces. Three trail locations of shear walls are selected and their performance is monitored in terms of structural response under different lateral loads. Required objectives are achieved by obtaining design and construction drawings of an existing reinforced concrete structure and modeling it on Finite Element Method (FEM) based computer software. The structure is redesigned and discussed with four different configurations (one without shear wall and three with shear walls). Main framing components (Beams, Columns and Shear walls) of the superstructure are designed using SAP 2000 V. 19.0 whereas substructure (foundation) of RC building was?designed using SAFE. American Concrete Institute (ACI) design specifications were used to calculate the cracked section stiffness or non-linear geometrical properties of the cracked section. Uniform Building Code (UBC-97) procedures were adopted to calculate the lateral earthquake loading on the structures. Structural response of the building was monitored at each story level for each earthquake force zone described by the UBC-97. The earthquake lateral forces were considered in both X and Y direction of the building. Each configuration of shear wall is carefully analyzed and effect of its location is calibrated by the displacement response of the structure. Eccentricity to the lateral stiffness of the building is imparted by changing the location of shear walls. Results of the study have shown that the location of shear wall significantly affects the lateral response of the structure under earthquake forces. It also motivates to carefully decide the center of lateral stiffness of building prior to deciding the location of shear walls. 展开更多
关键词 reinforced concrete Buildings COMPUTER aided Modelling shear walls Stiff-ness Deformations
下载PDF
Structural Analysis of a RC Shear Wall by Use of a Truss Model
8
作者 Panagis G. Papadopoulos Periklis E. Lamprou 《Open Journal of Civil Engineering》 CAS 2022年第3期320-352,共33页
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera... Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall. 展开更多
关键词 reinforced concrete shear wall Structural Analysis Truss Model Iterative Method Computer Program Boundary Columns and Beam Grid of Horizontal and Diagonal Reinforcing Steel Bars
下载PDF
Performance evaluation of low-rise infilled reinforced concrete frames designed by considering local effects on column shear demand
9
作者 Jarun SRECHAI Wongsa WARARUKSAJJA +1 位作者 Sutat LEELATAVIWAT Suchart LIMKATANYU 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2023年第5期686-703,共18页
The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength ... The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength and stiffness of the frame owing to their high strength and stiffness.However,local wall-frame interactions can also lead to increased shear demand in the columns owing to the compressive diagonal strut force from the infill wall,which can result in failure or in serious situations,collapse.In this study,the effectiveness of a design strategy to consider the complex infill wall interaction was investigated.The approach was used to design example RC frames with infill walls in locations with different seismicity levels in Thailand.The performance of these frames was assessed using nonlinear static,and dynamic analyses.The performance of the frames and the failure modes were compared with those of frames designed without considering the infill wall or the local interactions.It was found that even though the overall responses of the buildings designed with and without consideration of the local interaction of the infill walls were similar in terms the overall lateral strength,the failure modes were different.The proposed method can eliminate the column shear failure from the building.Finally,the merits and limitations of this approach are discussed and summarized. 展开更多
关键词 reinforced concrete frames infill wall seismic design method shear failure wall-frame interaction
原文传递
High-Rise Residential Reinforced Concrete Building Optimisation
10
作者 Haibei Xiong Miguel Angel Hidalgo Calvo 《Open Journal of Civil Engineering》 2015年第4期437-450,共14页
In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and ... In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and design criteria to considerate and many other factors, a general optimisation’s method is not simple to formulate. As a result, this paper focuses on how to provide a successful optimisation method for a particular building type, high-rise reinforced concrete buildings. The optimization method is based on decomposition of the main structure into substructures: floor system, vertical load resisting system, lateral load resisting system and foundation system;then each of the subsystems using the design criteria established at the building codes is improved. Due to the effect of the superstructure optimisation on the foundation system, vertical and lateral load resisting system is the last to be considered after the improvement of floor. Finally, as a case example, using the method explained in the paper, a 30-story-high high-rise residential building complex is analysed and optimised, achieving good results in terms of structural behaviour and diminishing the overall cost of the structure. 展开更多
关键词 STRUCTURE Optimisation HIGH-RISE RESIDENTIAL reinforced concrete Buildings shear-wall STRUCTURE Deep PILES Post GROUTING
下载PDF
HPC端部加强双钢板组合剪力墙的抗震性能
11
作者 袁朝庆 李国洋 +2 位作者 代晓辉 房宽光 计静 《黑龙江科技大学学报》 CAS 2024年第1期61-68,共8页
为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强... 为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强试件相比普通试件屈服荷载提高16.30%,峰值荷载提升13.40%;随着轴压比提高,HPC端部加强试件峰值荷载和屈服荷载分别提高7.22%和2.72%,随着轴压比减小,HPC端部加强试件延性提升22.26%;提高腹部腔体混凝土强度等级,HPC端部加强试件的屈服荷载和峰值荷载分别提高13.01%和11.14%,延性提升16.91%。 展开更多
关键词 HPC端部加强 双钢板组合剪力墙 抗震性能
下载PDF
Collapse Patterns and Their Discrimination of Reinforced Concrete Shear Wall Under Combined Stresses of Compression and Shear due to Strong Earthquake 被引量:1
12
作者 查支祥 刘西拉 许波 《Journal of Shanghai Jiaotong university(Science)》 EI 2020年第4期495-508,共14页
The collapse patterns of reinforced concrete(RC)shear walls under seismic load are proposed.The crack distribution and propagation of shear walls are specifically based on the failure criterions of Mohr-Coulomb with t... The collapse patterns of reinforced concrete(RC)shear walls under seismic load are proposed.The crack distribution and propagation of shear walls are specifically based on the failure criterions of Mohr-Coulomb with tension cutoff.Three zones and five different corresponding failure modes of RC shear walls are determined according to the transfer path of shear stress in shear wall.These failure modes of shear walls under seismic load are verified by many experimental results and can be utilized in collapsing analysis for frame-shear wall structure. 展开更多
关键词 reinforced concrete(RC) shear walls collapsing patterns seismic load
原文传递
地震下RC空心墩弯-剪数值模型及混合试验验证
13
作者 蒋雨润 梅竹 +2 位作者 刘洋 陈江 熊峰 《防灾减灾工程学报》 CSCD 北大核心 2024年第3期596-604,共9页
地震作用下钢筋混凝土空心截面中高桥墩多发生弯剪破坏,而其弯剪耦合反应的数值模拟方法尚不完善。针对当前弯剪串联模型中的剪切模型未考虑空心截面特征的问题,提出基于关键参数的剪切模型修正方法,并通过混合试验进行验证。分别从桥... 地震作用下钢筋混凝土空心截面中高桥墩多发生弯剪破坏,而其弯剪耦合反应的数值模拟方法尚不完善。针对当前弯剪串联模型中的剪切模型未考虑空心截面特征的问题,提出基于关键参数的剪切模型修正方法,并通过混合试验进行验证。分别从桥墩的剪跨比、混凝土开裂后剪切刚度、等效截面面积、桥墩有效高度与墩身混凝土斜裂缝倾角等参数入手,提出剪切模型关键参数的修正方法;基于修正的开裂剪切强度、开裂剪切位移、剪切极限承载力及其对应的剪切位移与剪切破坏位移,提出适用于空心桥墩剪切性能模拟的三折线型骨架曲线建立方法;通过组合剪切模型与基于纤维单元的弯曲模型,建立空心墩弯剪耦合反应的数值模型;与一座空心高墩桥混合试验结果对比,其桥墩子结构的物理试验结果验证了数值模拟方法。分析表明:通过本文所提数值模拟方法得到的空心桥墩弯剪滞回曲线与真实地震加载路径下的试验曲线匹配良好,能够模拟空心墩在真实地震作用下的弯剪滞回行为。 展开更多
关键词 钢筋混凝土空心墩 弯-剪耦合 剪切骨架模型 地震响应模拟 混合试验
下载PDF
钢板混凝土剪力墙拉弯剪性能试验研究
14
作者 蒙春丽 柯晓军 +1 位作者 苏益声 梁胤鸿 《工程力学》 EI CSCD 北大核心 2024年第5期146-154,共9页
超高层建筑“细柔”特征容易引起底部剪力墙在强震下处于拉-弯-剪复合受力状态,中国《超限高层建筑工程抗震设防专项审查技术要点》(建质[2015]67号)建议墙肢采用配置型钢/钢板的方式来改善该种抗震性能,但缺乏相关试验研究。为此,进行... 超高层建筑“细柔”特征容易引起底部剪力墙在强震下处于拉-弯-剪复合受力状态,中国《超限高层建筑工程抗震设防专项审查技术要点》(建质[2015]67号)建议墙肢采用配置型钢/钢板的方式来改善该种抗震性能,但缺乏相关试验研究。为此,进行了6片钢板混凝土剪力墙的低周往复荷载试验,研究了轴拉比、含钢率及剪跨比对墙肢拉弯剪性能的影响。研究表明:拉弯剪作用引起钢板混凝土剪力墙密集的裂缝分布和显著的钢材强化,并导致其剪切-拉弯耦合破坏。轴拉比增大,墙肢承载力、初始抗侧刚度和延性分别降低22%、41%和39%;剪跨比减小,墙肢承载力和抗侧刚度至少提升23%;同时增大含钢率和降低剪跨比,墙肢延性提高10%。相比其他国家规范,中国规范对拉弯剪作用下钢板混凝土剪力墙的抗剪承载力预测效果更好,但其未能考虑高含钢率对裂面销栓力的影响,故建议采用暗柱的初始含钢率进行修正。 展开更多
关键词 钢板混凝土剪力墙 低周往复荷载 拉弯剪性能 剪切-拉弯耦合破坏 承载力
下载PDF
集中配筋连接预制剪力墙抗震性能试验研究
15
作者 肖扬 卢谦 +3 位作者 罗小勇 陈林松 程俊峰 张璧玮 《中南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2024年第1期201-218,共18页
针对现有预制混凝土剪力墙接缝施工容错率低、混凝土现场浇筑作业量大和钢筋锚固过长等不足,提出一种使用超高性能混凝土(UHPC)的集中配筋连接预制剪力墙。通过对比1片现浇剪力墙试件、3片不同接缝形式的集中配筋连接预制剪力墙试件的... 针对现有预制混凝土剪力墙接缝施工容错率低、混凝土现场浇筑作业量大和钢筋锚固过长等不足,提出一种使用超高性能混凝土(UHPC)的集中配筋连接预制剪力墙。通过对比1片现浇剪力墙试件、3片不同接缝形式的集中配筋连接预制剪力墙试件的拟静力试验结果,揭示该类预制剪力墙的破坏规律和抗震性能、竖缝对墙体抗震性能的影响和连接钢筋的受力特点。采用ABAQUS软件对试件进行有限元模拟,分析轴压比和集中配筋率对试件抗震性能的影响。研究结果表明:预制试件与现浇试件具有相同的破坏规律,均为弯剪破坏;这2类试件的滞回曲线均较饱满,骨架曲线走势基本一致,耗能能力接近,且预制试件的最小承载力仅比现浇试件低5.6%,表明预制试件的抗震性能与现浇试件的抗震性能基本相同;竖缝对剪力墙承载力的影响较小,使剪力墙的延性和耗能能力有一定的削弱;不同竖缝形式预制墙的抗震性能相近但各有特点,竖缝形式预制墙采用UHPC出筋搭接具有更好的整体性,采用U形键槽的预制墙具有更大的刚度和更强的耗能能力;连接钢筋的应力分布具有典型受弯构件的特征;随着轴压比增加,模型的刚度和承载力不断增加,在轴压比从0.05增加到0.30时,最大的峰值荷载增幅发生在轴压比从0.05到0.10时,从承载力的提高、刚度、耗能和墙角抬高等方面考虑,试件的集中配筋率保持在90%~110%为宜。 展开更多
关键词 预制剪力墙 集中配筋 拟静力试验 UHPC(ultra-high performance concrete) 抗震性能
下载PDF
钢筋混凝土剪力墙抗震滞回性能的多元时序深度神经网络预测
16
作者 袁程 熊青松 孔庆钊 《工程力学》 EI CSCD 北大核心 2024年第6期66-76,共11页
钢筋混凝土剪力墙结构抗震性能优越且造价合理,广泛用于抗震烈度较高的地区。准确地预测剪力墙的滞回性能与骨架曲线,直接决定了结构设计与分析的准确度与可靠性。该文提出了一种基于深度学习的剪力墙结构滞回性能预测方法,可以根据结... 钢筋混凝土剪力墙结构抗震性能优越且造价合理,广泛用于抗震烈度较高的地区。准确地预测剪力墙的滞回性能与骨架曲线,直接决定了结构设计与分析的准确度与可靠性。该文提出了一种基于深度学习的剪力墙结构滞回性能预测方法,可以根据结构的基本设计参数(如材料属性、几何尺寸、荷载工况等),直接预测出其承载力。通过3组剪力墙的滞回试验预测1组结构的滞回曲线,结果表明:通过比较时域的特征,深度学习方法具有较高的预测精度。通过与有限元仿真结果对比,深度学习仅需输入不同参数就能够快速预测滞回曲线,其优势还在于具有较高的计算效率,而有限元仿真需要几何建模、本构模型选取、材料属性输入和荷载工况定义,整个过程相较于深度学习耗时耗力。 展开更多
关键词 钢筋混凝土剪力墙 多元时序深度神经网络 滞回曲线 抗震性能 骨架曲线
下载PDF
高延性混凝土局部置换加固剪力墙抗震性能试验分析
17
作者 赵艳梅 《江西建材》 2024年第3期71-72,79,共3页
为探究高延性混凝土在提升剪力墙抗震性能方面的作用,文中研究制备了改性活性粉末混凝土,其中添加了聚丙烯纤维和钢纤维。制作三组剪力墙试件,利用高延性混凝土对第三组试件进行局部置换加固,另外两组作为对照组。通过向试件施加垂直载... 为探究高延性混凝土在提升剪力墙抗震性能方面的作用,文中研究制备了改性活性粉末混凝土,其中添加了聚丙烯纤维和钢纤维。制作三组剪力墙试件,利用高延性混凝土对第三组试件进行局部置换加固,另外两组作为对照组。通过向试件施加垂直载荷与水平载荷模拟地震作用,观察其破坏形态、位移量、钢筋应变。经对比可知,加固试件的承载能力、变形消能效果均强于对照组,说明加固后的剪力墙具有更好的抗震性能。 展开更多
关键词 高延性混凝土 局部置换加固 剪力墙 抗震性能
下载PDF
某超限高层剪力墙结构抗震性能研究
18
作者 谢雯馨 詹雷颖 《江西建材》 2024年第2期119-122,共4页
文中以广西南宁市某超限工程为例,重点讨论了在结构设计中,需要解决的超限判定、计算要点、步骤、优化方法等问题。首先利用YJK和PKPM两个软件建立对比模型,从而相互验证所研究结构的刚度及承载力影响,完成了小震、中震的性能化分析;再... 文中以广西南宁市某超限工程为例,重点讨论了在结构设计中,需要解决的超限判定、计算要点、步骤、优化方法等问题。首先利用YJK和PKPM两个软件建立对比模型,从而相互验证所研究结构的刚度及承载力影响,完成了小震、中震的性能化分析;再用Midas/Building实现了模拟大震作用下的动力弹塑性损伤分析。结果表明,采取的结构加强措施能够基本满足设定的性能目标。 展开更多
关键词 钢筋混凝土剪力墙结构 超限高层 动力弹塑性分析 抗震性能设计
下载PDF
剪力墙置换加固设计分析
19
作者 程徐进 《工程技术研究》 2024年第7期183-185,共3页
某高层住宅建筑物经对该工程墙、柱混凝土抗压强度进行质量检测,发现部分墙、柱结构构件的混凝土强度推定值不满足要求。文章依据检测报告中墙、柱结构构件的混凝土抗压强度的检测结果,对原结构进行复核验算。根据复核验算结果和检测建... 某高层住宅建筑物经对该工程墙、柱混凝土抗压强度进行质量检测,发现部分墙、柱结构构件的混凝土强度推定值不满足要求。文章依据检测报告中墙、柱结构构件的混凝土抗压强度的检测结果,对原结构进行复核验算。根据复核验算结果和检测建议,对原结构不满足要求的墙、柱结构构件进行加固设计。针对轴压比大于规范限值要求的框架柱,采用增大截面法进行加固处理;针对轴压比大于规范限值要求的剪力墙,采用全截面置换混凝土法进行加固处理,可供参考。 展开更多
关键词 剪力墙 加固设计 置换混凝土加固法 增大截面加固法 混凝土抗压强度 复核验算
下载PDF
混凝土置换法在剪力墙结构加固中的应用研究进展
20
作者 时斌刚 《江苏建筑》 2024年第1期86-89,共4页
随着结构加固理论和技术的不断发展,越来越多的学者对混凝土置换加固技术展开了研究。文章总结了近年来混凝土置换加固技术工程应用以及设计理论的研究进展,分析了已有的研究成果和问题。分析表明:置换混凝土加固法可有效解决结构混凝... 随着结构加固理论和技术的不断发展,越来越多的学者对混凝土置换加固技术展开了研究。文章总结了近年来混凝土置换加固技术工程应用以及设计理论的研究进展,分析了已有的研究成果和问题。分析表明:置换混凝土加固法可有效解决结构混凝土强度不足的问题,适用于承重结构受压区混凝土强度偏低或有局部严重缺陷的加固;然而,现有研究缺乏置换过程中对结构受力变形的控制指标以及能够广泛应用于实际置换工程当中的设计理论方法;在模拟免支撑混凝土置换过程时,应考虑施工过程中置换用材料的时变效应。未来,解决这些问题是工程应用与理论研究中值得关注的重点方向。 展开更多
关键词 剪力墙结构 结构加固 混凝土置换法 研究进展
下载PDF
上一页 1 2 38 下一页 到第
使用帮助 返回顶部