In order to study bearing characteristics of bridge pile at steep slope under complex loads in mountians, according to double pile-column bridge piers engineering at steep slope and test models in laboratory, finite e...In order to study bearing characteristics of bridge pile at steep slope under complex loads in mountians, according to double pile-column bridge piers engineering at steep slope and test models in laboratory, finite element analysis of pile-column bridge piers was carried out using software ADINA under different loadings, such as horizontal loading in the longitudinal direction along bridge, vertical loadings, slope top loadings and complex loadings. The numerical simulation results show that displacements of front pile pier top and back pile pier top are different under horizontal loadings in the longitudinal direction along bridge or vertical loadings, the displacements of front pile pier top are higher than those of back pile pier top, and its difference increases with the increase of loadings. Vertical displacements will also appear under slope top loadings, and displacements of front pier top are higher than those of back pier top too, while its difference reduces with the increase of loadings. Displacements of both front pile pier top and back pile pier top under comlex loading are larger than those under single loading.展开更多
The disorders originated from architectural design in buildings, show in different forms. One of them is the level difference originated from lot’s slope which affects structures through short column phenomenon. The ...The disorders originated from architectural design in buildings, show in different forms. One of them is the level difference originated from lot’s slope which affects structures through short column phenomenon. The great stiffness of short columns enables them to absorb large amounts of structural energy. Inattention of some manuals and regulations such as Earthquake regulations to this phenomenon necessitates paying further attention to it. On this basis, the present study employed experimental modeling and numerical modeling for a four-story reinforced concrete building that involves the analysis of simple 2-D frames of varying floor heights and varying number of bays using a very popular software tool STAAD Pro on both a sloping and a flat lot. Also Sap2000 software had been used to show that the displacement of floors is greater for a flat lot building than a sloping lot building. However, the increase in shear was found to be quite greater in short columns compared to common ones and an enormous moment should be tolerated by sloping lot structures. The greater stiffness of the structure was also revealed by non-linear static (Push-Over) analysis. According to the results, short column are required to have more resistant sections and are suggested to be reinforced with more bars. In addition, more steel should be used as stirrups than as longitudinal bars. Also for existing structures, shear capacity of short columns should be retrofitted by FRP, Steel Jacket or other materials.展开更多
基金Projects(50878083,50578060)supported by the National Natural Science Foundation of ChinaProject(200831878531)supported by the Ministry of Transportation of China
文摘In order to study bearing characteristics of bridge pile at steep slope under complex loads in mountians, according to double pile-column bridge piers engineering at steep slope and test models in laboratory, finite element analysis of pile-column bridge piers was carried out using software ADINA under different loadings, such as horizontal loading in the longitudinal direction along bridge, vertical loadings, slope top loadings and complex loadings. The numerical simulation results show that displacements of front pile pier top and back pile pier top are different under horizontal loadings in the longitudinal direction along bridge or vertical loadings, the displacements of front pile pier top are higher than those of back pile pier top, and its difference increases with the increase of loadings. Vertical displacements will also appear under slope top loadings, and displacements of front pier top are higher than those of back pier top too, while its difference reduces with the increase of loadings. Displacements of both front pile pier top and back pile pier top under comlex loading are larger than those under single loading.
文摘The disorders originated from architectural design in buildings, show in different forms. One of them is the level difference originated from lot’s slope which affects structures through short column phenomenon. The great stiffness of short columns enables them to absorb large amounts of structural energy. Inattention of some manuals and regulations such as Earthquake regulations to this phenomenon necessitates paying further attention to it. On this basis, the present study employed experimental modeling and numerical modeling for a four-story reinforced concrete building that involves the analysis of simple 2-D frames of varying floor heights and varying number of bays using a very popular software tool STAAD Pro on both a sloping and a flat lot. Also Sap2000 software had been used to show that the displacement of floors is greater for a flat lot building than a sloping lot building. However, the increase in shear was found to be quite greater in short columns compared to common ones and an enormous moment should be tolerated by sloping lot structures. The greater stiffness of the structure was also revealed by non-linear static (Push-Over) analysis. According to the results, short column are required to have more resistant sections and are suggested to be reinforced with more bars. In addition, more steel should be used as stirrups than as longitudinal bars. Also for existing structures, shear capacity of short columns should be retrofitted by FRP, Steel Jacket or other materials.