Rotor angle stability(RAS)prediction is critically essential for maintaining normal operation of the interconnected synchronous machines in power systems.The wide deployment of phasor measurement units(PMUs)promotes t...Rotor angle stability(RAS)prediction is critically essential for maintaining normal operation of the interconnected synchronous machines in power systems.The wide deployment of phasor measurement units(PMUs)promotes the development of data-driven methods for RAS prediction.This paper proposes a temporal and topological embedding deep neural network(TTEDNN)model to accurately and efficiently predict RAS by extracting the temporal and topological features from the PMU data.The grid-informed adjacency matrix incorporates the structural and electrical parameter information of the power grid.Both the small-signal RAS with disturbance under initial operating conditions and the transient RAS with short circuits on transmission lines are considered.Case studies of the IEEE 39-bus and IEEE 300-bus power systems are used to test the performance,scalability,and robustness against measurement uncertainties of the TTEDNN model.Results show that the TTEDNN model performs best among existing deep learning models.Furthermore,the superior transfer learning ability from small-signal RAS conditions to transient RAS conditions has been proved.展开更多
q-axis rotor flux can be chosen to form a model reference adaptive system(MRAS)updating rotor time constant online in induction motor drives.This paper presents a stability analysis of such a system with Popov’s hype...q-axis rotor flux can be chosen to form a model reference adaptive system(MRAS)updating rotor time constant online in induction motor drives.This paper presents a stability analysis of such a system with Popov’s hyperstability concept and small-signal linearization technique.At first,the stability of q-axis rotor flux based MRAS is proven with Popov’s Hyperstability theory.Then,to find out the guidelines for optimally designing the coefficients in the PI controller,acting as the adaption mechanism in the MRAS,small-signal model of the estimation system is developed.The obtained linearization model not only allows the stability to be verified further through Routh criterion,but also reveals the distribution of the characteristic roots,which leads to the clue to optimal PI gains.The theoretical analysis and the resultant design guidelines of the adaptation PI gains are verified through simulation and experiments.展开更多
Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The s...Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The supply is taken from Egi generating station located at Total Nigeria Limited Gas Plant Obite at voltage level of 33 KV to Egi communities. This work focuses on the transient nature of network stability since transient fault is the most dangerous in elec-trical systems. The swinging of the generator rotor in the event of transient three-phase short circuit fault can be monitored by the circuit breakers and the protective relays which causes mal-functioning of the circuit breakers and pro-tective relays leading to abnormal behavior of the network. Therefore, data obtained from the power station were used as a case study of Independent Power Producer (IPP) in Nigeria. For investigation of the power angle, angular velocity, rotor angle differential changes, and angular velocity differential changes, an electrical transient analyzer tool was employed (ETap version 16.00) for circuit breaker and protective relay time setting of (0.00, 0.05, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60). The work used the Trapezoidal numerical technique for data analysis. The graphs were plotted using Matlab R2015a and the results obtained showed that when a symmetrical three-phase short circuit fault occur at one or any of the feeders, the fault must be cleared as quick as possible through the coordination of the circuit breakers and protective relays. For this research work, 17 cycles corresponding to relay time setting of t = 0.34 s were recommended and at each cycle, changes in time with respect to changes in rotor angle, angular velocity, rotor differential and angular velocity differential were calculated on the power network simultaneously. The results demonstrated that the Trapezoidal method is numerically stable, accurate and has faster respond time when compared to Modified Euler and swing equation techniques in event of fault occurrence in network.展开更多
含高比例新能源交直流混联电网的稳定特性已发生深刻变化,功角稳定依然是威胁系统安全运行的关键问题,相关研究对标准算例的真实性、合理性及代表性提出更高的要求。该文根据实际电网拓扑和数据,构建适用于功角稳定特性研究的功角稳定...含高比例新能源交直流混联电网的稳定特性已发生深刻变化,功角稳定依然是威胁系统安全运行的关键问题,相关研究对标准算例的真实性、合理性及代表性提出更高的要求。该文根据实际电网拓扑和数据,构建适用于功角稳定特性研究的功角稳定机电暂态仿真算例(Chinese society for electricalengineering-rotoranglestability,CSEE-RAS),该系统以500kV为主网架,包含2个区域、1个交流通道、1个直流通道。提供2种运行方式,分别对应动态、暂态功角稳定场景,上述场景新能源出力占比均在50%以上。考虑新能源出力占比、机组接入位置和控制策略等因素,量化不同因素对稳定水平的影响。敏感性分析结果表明,该算例较为全面地反映了机电暂态尺度下的不同功角稳定特性,且具有灵活的拓展能力,可为功角稳定分析与控制的相关研究提供基础平台,有助于不同结论的横向比较和研究人员科研效率的提升。展开更多
This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(...This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.展开更多
基金supported in part by the National Natural Science Foundation of China(No.21773182)the HPC Platform,Xi’an Jiaotong University。
文摘Rotor angle stability(RAS)prediction is critically essential for maintaining normal operation of the interconnected synchronous machines in power systems.The wide deployment of phasor measurement units(PMUs)promotes the development of data-driven methods for RAS prediction.This paper proposes a temporal and topological embedding deep neural network(TTEDNN)model to accurately and efficiently predict RAS by extracting the temporal and topological features from the PMU data.The grid-informed adjacency matrix incorporates the structural and electrical parameter information of the power grid.Both the small-signal RAS with disturbance under initial operating conditions and the transient RAS with short circuits on transmission lines are considered.Case studies of the IEEE 39-bus and IEEE 300-bus power systems are used to test the performance,scalability,and robustness against measurement uncertainties of the TTEDNN model.Results show that the TTEDNN model performs best among existing deep learning models.Furthermore,the superior transfer learning ability from small-signal RAS conditions to transient RAS conditions has been proved.
文摘q-axis rotor flux can be chosen to form a model reference adaptive system(MRAS)updating rotor time constant online in induction motor drives.This paper presents a stability analysis of such a system with Popov’s hyperstability concept and small-signal linearization technique.At first,the stability of q-axis rotor flux based MRAS is proven with Popov’s Hyperstability theory.Then,to find out the guidelines for optimally designing the coefficients in the PI controller,acting as the adaption mechanism in the MRAS,small-signal model of the estimation system is developed.The obtained linearization model not only allows the stability to be verified further through Routh criterion,but also reveals the distribution of the characteristic roots,which leads to the clue to optimal PI gains.The theoretical analysis and the resultant design guidelines of the adaptation PI gains are verified through simulation and experiments.
文摘Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The supply is taken from Egi generating station located at Total Nigeria Limited Gas Plant Obite at voltage level of 33 KV to Egi communities. This work focuses on the transient nature of network stability since transient fault is the most dangerous in elec-trical systems. The swinging of the generator rotor in the event of transient three-phase short circuit fault can be monitored by the circuit breakers and the protective relays which causes mal-functioning of the circuit breakers and pro-tective relays leading to abnormal behavior of the network. Therefore, data obtained from the power station were used as a case study of Independent Power Producer (IPP) in Nigeria. For investigation of the power angle, angular velocity, rotor angle differential changes, and angular velocity differential changes, an electrical transient analyzer tool was employed (ETap version 16.00) for circuit breaker and protective relay time setting of (0.00, 0.05, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60). The work used the Trapezoidal numerical technique for data analysis. The graphs were plotted using Matlab R2015a and the results obtained showed that when a symmetrical three-phase short circuit fault occur at one or any of the feeders, the fault must be cleared as quick as possible through the coordination of the circuit breakers and protective relays. For this research work, 17 cycles corresponding to relay time setting of t = 0.34 s were recommended and at each cycle, changes in time with respect to changes in rotor angle, angular velocity, rotor differential and angular velocity differential were calculated on the power network simultaneously. The results demonstrated that the Trapezoidal method is numerically stable, accurate and has faster respond time when compared to Modified Euler and swing equation techniques in event of fault occurrence in network.
文摘含高比例新能源交直流混联电网的稳定特性已发生深刻变化,功角稳定依然是威胁系统安全运行的关键问题,相关研究对标准算例的真实性、合理性及代表性提出更高的要求。该文根据实际电网拓扑和数据,构建适用于功角稳定特性研究的功角稳定机电暂态仿真算例(Chinese society for electricalengineering-rotoranglestability,CSEE-RAS),该系统以500kV为主网架,包含2个区域、1个交流通道、1个直流通道。提供2种运行方式,分别对应动态、暂态功角稳定场景,上述场景新能源出力占比均在50%以上。考虑新能源出力占比、机组接入位置和控制策略等因素,量化不同因素对稳定水平的影响。敏感性分析结果表明,该算例较为全面地反映了机电暂态尺度下的不同功角稳定特性,且具有灵活的拓展能力,可为功角稳定分析与控制的相关研究提供基础平台,有助于不同结论的横向比较和研究人员科研效率的提升。
文摘This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.